Records from 1996 to 2026. Most recent: inspection, 13 August 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 52
13 August 2026
Deficiency Check
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 8463235
29 July 2026
Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 8448760
15 May 2025
COI Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 8136622
17 October 2024
Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8018995
22 May 2024
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7917395
24 May 2023
Periodic Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7696316
15 February 2023
Examination of Repairs
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7637243
5 April 2022
Cargo Tank Internal · Annual Inspection · Hull Examination
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7425313
19 August 2021
Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7291282
18 May 2020
COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6955508
28 October 2019
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6844142
1 July 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6732493
11 June 2018
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6441050
22 June 2017
Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6183497
20 April 2017
Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6132077
10 April 2017
Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6121299
13 July 2016
Administrative Inspection · Examination of Repairs · Internal Structural Exam · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5976177
11 May 2015
Administrative Inspection · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5123173
23 July 2014
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4939003
12 July 2013
Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4685002
7 February 2012
Cargo Tank Internal · Periodic Inspection · Drydock Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4239305
18 October 2011
Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4170946
16 August 2011
Annual Inspection · MTSA Verification · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4117522
29 October 2010
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3880611
25 August 2010
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3833496
10 May 2010
Administrative Inspection · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3734992
12 August 2009
MTSA Verification · Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3563206
27 August 2008
Periodic Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3310983
11 July 2007
Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2990668
24 August 2006
Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2758116
6 March 2006
Administrative Inspection
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2596875
31 May 2005
COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 2374136
27 December 2004
Administrative Inspection
Administrative · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2264976
1 November 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2232448
6 July 2004
Annual Inspection · MTSA Verification
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 2126973
11 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1962715
25 July 2003
Annual Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1856737
8 July 2002
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1644580
21 May 2002
Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1619112
15 May 2002
Annual Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1616990
7 February 2002
Hull Examination · Cargo Tank Internal
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1484900
5 July 2001
Re-Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1399663
17 October 2000
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1055297
23 June 2000
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1050942
9 September 1999
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1418590
4 February 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 191457
4 February 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 771380
29 October 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 803577
24 July 1998
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 798070
22 August 1997
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1120591
25 October 1996
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1454372
12 August 1996
Initial Certification · Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1088662
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Loading instrument
Issued 22 May 2024
Resolved
Each cargo tank of a tankship must be equipped with an intrinsically safe high level alarm and a tank overfill alarm. Tank #2 Overfill alarm is inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2024
Resolved 28 May 2024
Resolution: Tank 32 overfill repaired.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Loading instrument
Issued 24 May 2023
Resolved
Each cargo tank of a tankship must be equipped with an intrinsically safe high level alarm and a tank overfill alarm. Tanks 1 & 3 High Level and Overfill alarms were disbled and inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2023
Resolved 22 June 2023
Resolution: Installed High Level Alarms on tanks 1 & 3. All SAT
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 April 2022
Resolved
Each tank vessel must undergo drydock, internal structural, and cargo tank internal examinations. Vessel has a fresh water service examination interval in accordance with 46 CFR Table 31.10-21(b). Vessel is overdue for its drydock and cargo tank internal examination. Vessel is prohibited from cargo operations until it has received a credit drydock and cargo tank internal examination.
Movement of the vessel from Ingram Fleet #1 requires pre-approval. Provide a voyage plan prior to vessel movement.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 April 2022
Resolved 20 April 2022
Resolution: Cleared to the satisfaction of the attending Coast Guard marine inspector.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 October 2019
Resolved
Vessel must have approved Vessel Security Plan. Vessel must provide approved Vessel Security Plan prior to cargo operations.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 October 2019
Resolution: 29OCT2019: Vessel representative provided MSC approval letter for VSP. MISLE activity closed.
Deck/Cargo › Vapor Control Systems › Vessel Vapor Overpressure/Vacuum Protection
Issued 14 June 2018
Resolved
The barge is authorized to carry Grade “A” and lower cargoes but the vent riser was not installed. Vessel has only been carrying Caustic Soda, but the way the COI and CAA are written, the vent riser is required. Prior to cargo operations with Grades A,B, or C cargoes, reinstall the vent riser or amend the COI to reflect that the barge is only authorized to carry Grade D and below cargoes and specified cargoes in accordance with the CAA.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2018
Resolved 15 June 2018
Resolution: Received request to restrict cargo carriage requirements on COI. Amended COI.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 11 May 2015
Resolved
Prove proper operation of overfill protection devices.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2015
Resolution: Received tech report from ERL technician showing that one device was replaced and system tested satisfactorily.
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 11 May 2015
Resolved
Prove proper operation of cargo pump engine emergency shutdown.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2015
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 11 May 2015
Resolved
Empty cargo manifold containment boxes.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2015
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 27 August 2008
Resolved
Clean port and starboard spill containment to maintain required capacity.
Due 27 September 2008
Resolved 12 August 2009
Resolution: Spill containment clean.
Deck/Cargo › Holds/Tanks › Hatch
Issued 27 August 2008
Resolved
Properly mark cargo tank hatches.
Due 27 September 2008
Resolved 12 August 2009
Resolution: CT hatches properly marked.
Deck/Cargo › Holds/Tanks › Hatch
Issued 27 August 2008
Resolved
Replace broken dog on port stern void hatch.
Due 27 September 2008
Resolved 12 August 2009
Resolution: Replaced dog.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 11 July 2007
Resolved
Prove proper operation of the cargo tank high level alrm system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 August 2007
Resolved 13 July 2007
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 11 July 2007
Resolved
Renew #2 and #3 cargo tank high level indicating dipsticks.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 August 2007
Resolved 13 July 2007
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 11 July 2007
Resolved
Repaint required vapor stripe on vapor recovery piping manifold.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 August 2007
Resolved 13 July 2007
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 24 August 2006
Resolved
REMOVE ALL HIGH CARGO LEVEL STICKS OR REPAIR #2 AND #3 CARGO HOLD HIGH LEVEL STICKS PRIOR TO LOADING ANY LIQUID CARGO.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2006
Resolved 25 August 2006
Construction/Loadline › Hull › Stringer
Issued 24 August 2006
Resolved
GRIND AND RE-WELD FRACTURED WELD AT TOP OF THE FORWARD BUCK FRAME AT THE SIDESHELL CONNECTION IN WAY OF #3 PORT SIDE VOID.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2006
Resolved 24 August 2006
Deck/Cargo › Vapor Control Systems
Issued 25 July 2003
Resolved
Demonstrate proper operation of liquid overfill protection, prior to onload of cargo, to the satisfaction of an attending Coast Guard Marine Inspector. LEGACY COMPONENT DESC: Liquid Overfill Protection
Action required: 705 - Other - as specified
Resolved 30 July 2003
Resolution: Tested alarm system. Sat. 835 removed.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 15 May 2002
Resolved
Prove proper operation of #2 cargo tank valve closure indicator.
Condition: Improper/Lack of Maintenance
Due 14 June 2002
Resolved 15 May 2002
Resolution: Set screws securing threaded collar of valve closure indicator to reachrod had worked loose and were retightened.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 15 May 2002
Resolved
Replace torn flame screen in #1 cargo tank ullage opening.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2002
Resolved 15 May 2002
Resolution: Flame screen replaced.