PHYLLIS ANN is a 1967 passenger vessel (inspected). The Coast Guard has recorded 25 inspections since 2016, most recently in August 2025, along with 59 deficiencies and 5 casualty investigations between 2004 and 2018.

Records from 2004 to 2025. Most recent: inspection, 25 August 2025.

Built
1967
Last inspected
25 August 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 25 August 2025
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8991566
WM5322
Flag
UNITED STATES
Maury page id
psix-43822

Documentation record

Registered dimensions (L × B × D)104.8 ft × 28.0 ft × 9.3 ft
Registered tonnagegross 198 / net 134
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWILEY MANUFACTURING COMPANY · PORT DEPOSIT, MD, UNITED STATES · built 1967
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 21 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it198 - Regulatory (Subpart C or D), Gross Ton
134 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 25

25 August 2025 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8217574
11 June 2025 Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8166475
9 September 2024 Drydock Extension
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7999657
29 July 2024 DAPI Audit · Deficiency Check · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7959923
29 February 2024 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7873607
31 July 2023 Deficiency Check · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7746449
31 July 2023 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7768729
16 March 2023 Re-Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7655172
20 July 2022 Internal Structural Exam · COI Inspection · MTSA Verification · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7512096
24 May 2022 DAPI Audit
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7459484
13 January 2022 Re-Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7379967
4 August 2021 MTSA Verification · Internal Structural Exam · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7265472
9 March 2021 Periodic Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7153690
16 December 2020 Periodic Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7116986
14 September 2020 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7057935
15 July 2020 COI Inspection · MTSA Verification · DAPI Audit
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7007173
19 September 2019 Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6815520
22 July 2019 MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6758427
28 March 2019 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6653349
23 July 2018 COI Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6487981
6 July 2018 Re-Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6469096
3 April 2018 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6385610
31 July 2017 Deficiency Check · MTSA Verification · Hull Examination · DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6226510
28 July 2017 Administrative Inspection · Internal Structural Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6223466
9 August 2016 MTSA Verification · COI Inspection · Administrative Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5947932

Deficiency record · 59

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 July 2024 Resolved
Provide annual service report for pocket boiler, last inspection was Feb 2023.
Action required: 705 - Other - as specified
Due 29 August 2024
Resolved 10 September 2024
Resolution: Annual service completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 29 July 2024 Resolved
Repair / replace exhaust leak elbow 90 deg over 20 KW generator.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2024
Resolved 6 August 2024
Resolution: Repairs completed to exhaust system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 29 July 2024 Resolved
Repair air shut down stop gasket.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2024
Resolved 6 August 2024
Resolution: New air stop gasket installed, test sat.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 29 July 2024 Resolved
Provide copy of COD on vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2024
Resolved 29 August 2024
Resolution: Original document on vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 29 July 2024 Resolved
Provide 03 Orange smoke signals.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2024
Resolved 6 August 2024
Resolution: 03 Orange smoke signals provided on vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 29 July 2024 Resolved
Repair / replace IBA aft port side cradle.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2024
Resolved 12 September 2024
Resolution: Primary life saving requirement are reduced and meets pax carriage.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 July 2024 Resolved
Provide hydro report of CO2 bottles.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2024
Resolved 10 September 2024
Resolution: Annual service report completed.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 29 July 2024 Resolved
Provide drills to include Fire, MOB, and abandon ship.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2024
Resolved 10 September 2024
Resolution: New ownership to complete at NTZ inspection.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 29 July 2024 Resolved
Replace expired components in First Aid Kits.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2024
Resolved 10 September 2024
Resolution: First Aid kit meets published content requirements.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 29 July 2024 Resolved
Provide servicing of all IBA's on vessel, vessel is restricted to 150 total persons, provided 1 50 man IBA on port side 75 persons, 1 50 man IBA on stbd side of vessel 75 persons with a total of 150 persons.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2024
Resolved 10 September 2024
Resolution: All IBA's (02) 50 man are in service dates.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 31 July 2023 Resolved
Replace expired HRU. Vessel restricted to operating NMT 3 miles from land until corrected.
Action required: 705 - Other - as specified
Due 31 August 2023
Resolved 2 August 2023
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 31 July 2023 Resolved
Provide proof of annual servicing of Fire Extinguishing equipment.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 August 2023
Resolved 8 August 2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 August 2022 Resolved
Repair/Replace Fire Axe bracket, starboard forward.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2022
Resolved 14 September 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 4 August 2021 Resolved
Engine room door found not to be weather tight.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 September 2021
Resolution: Door repaird to wx tight condition.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 4 August 2021 Resolved
Scheduled annual inspection of both fixed and portable fire fighting equipment.
Action required: 10 - Deficiency Rectified
Due 4 August 2021
Resolved 4 August 2021
Resolution: Technicians attended vessel to complete service, report available, test sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 August 2021 Resolved
Install life jackets at all watch stations.
Action required: 10 - Deficiency Rectified
Due 4 August 2021
Resolved 4 August 2021
Resolution: 2 addition life jackets installed at watch stations.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 6 August 2020 Resolved
Modify CO2 cage as discussed to provide ready access and clear instruction.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2020
Resolved 14 August 2020
14 - Pollution Prevention › 142 - MARPOL Annex II › Vent. Procedures/equipment
Issued 6 August 2020 Resolved
Provide/Prove operation of containment plugs at stbd fill & vent.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2020
Resolved 14 August 2020
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 August 2020 Resolved
Label Fire Extinguishing station in stbd aft pax cabin (new bulkhead panel) as well as Extinguisher #3.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2020
Resolved 14 August 2020
10 - Safety of Navigation › N/A - No Subsystem › Bridge operation
Issued 6 August 2020 Resolved
Prove operation of SPP call bell with engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2020
Resolved 17 August 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 6 August 2020 Resolved
Replace port MDE high temp sensoe alarm and 20kw generator high temp sensor.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2020
Resolved 17 August 2020
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 6 August 2020 Resolved
Provide fire servicing report.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2020
Resolved 18 August 2020
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 30 August 2019 Resolved
Vessel to install a USCG approved rescue boat as per OCMI letter issued by SNNE. Vsl currently has a row boat and manual falls that have been deemed insufficent by the local OCMI.
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 September 2020
Resolution: Exemption Request approved.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 August 2019 Resolved
Provide new ring buoy (fwd stbd side).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2019
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 August 2019 Resolved
Stencil corrected instructions for fixed CO2 system. (Pull indicators for cylinder head and stop valves are incorrectly identified/switched).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 28 March 2019 Resolved
E-Generator will not stay running, genset shutdowns due to low oil pressure.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2019
Resolution: Corrected
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 March 2019 Resolved
Repair the Temperature gauage for the 20KW Genset
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2019
Resolved 1 April 2019
Resolution: Corrected
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 28 March 2019 Resolved
Replace the glass in the valve control pull station on the main deck.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2019
Resolved 1 April 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 March 2019 Resolved
Provide a valid FCC Station License and a Bridge to Bridge cert.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2019
Resolved 17 May 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 28 March 2019 Resolved
Move the embarkation lights to illuminate the IBAs and life raft stations.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2019
Resolved 1 May 2019
Resolution: corrected
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 March 2019 Resolved
Repair the electric bilge pump; pump would not move water.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2019
Resolved 1 May 2019
Resolution: corrected
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 8 August 2018 Resolved
Repair the high water temperature sensor on the 20KW Genset.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2018
Resolved 28 March 2019
Resolution: Corrected
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 August 2018 Resolved
Replace the flexible service loops (hoses) from the CO2 bottles to the CO2 mainifold.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2018
Resolved 27 September 2018
Resolution: Replaced
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 8 August 2018 Resolved
Repair the audible alarm for the main engine alarm panel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2018
Resolved 27 September 2018
Resolution: Cleared
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 August 2018 Resolved
Repair or replace the watt meter on the 20KW swithboard, meter is not working.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2018
Resolved 28 March 2019
Resolution: Meter is working
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 August 2018 Resolved
Locate and repair the ground on the 20KW genset, that is visible on the switchboard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2018
Resolved 27 September 2018
Resolution: Cleared
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 August 2018 Resolved
Provide a donning placard for the various types of PFDs onboard the vessel.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2018
Resolved 28 March 2019
Resolution: Corrected
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 8 August 2018 Resolved
Provide IMO symbols at the Ring Buoy and Liferaft locations
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2018
Resolved 28 March 2019
Resolution: Corrected
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 8 August 2018 Resolved
Conduct MOB & Fire drills to the satisfaction of USCG.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2018
Resolved 27 September 2018
Resolution: Cleared
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 July 2018 Resolved
Replace the expired portable fire extinguisher in the port pax seating area.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2018
Resolved 17 July 2018
Resolution: Corrected
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 17 July 2018 Resolved
Install the IBAs & L/R with an hydrostatic release and not using lifefloat weak links.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 August 2018
Resolution: Def issued in error, vls permitted to have weak links for L/F & BA iaw NVIC 4-86.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 17 July 2018 Resolved
Repair the GA in both pax seating areas.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 August 2018
Resolution: Repaired
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 July 2018 Resolved
Provide a Lifejacket donning placard in the 01 stbd jacket container box
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 August 2018
Resolution: Corrected
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 22 August 2017 Resolved
No homeport was listed on the ring buoys, ROCKPORT
Action required: 705 - Other - as specified
Due 17 September 2017
Resolved 5 September 2017
Resolution: Corrected
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 8 August 2017 Resolved
Provide testing of main engine's high temp alarm
Action required: 705 - Other - as specified
Due 8 September 2017
Resolved 15 August 2017
Resolution: Corrected.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 August 2017 Resolved
Replace the expired medicene in first aid kit
Action required: 705 - Other - as specified
Due 8 September 2017
Resolved 17 August 2017
Resolution: corrected
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 8 August 2017 Resolved
Provide a new donning placard in the stbd pax seating area.
Action required: 705 - Other - as specified
Due 8 September 2017
Resolved 17 August 2017
Resolution: corrected
Lifesaving › Lifebuoys › Serviceable
Issued 8 August 2017 Resolved
Replace the aft ring buoy on fantail.
Action required: 705 - Other - as specified
Due 8 September 2017
Resolved 5 September 2017
Resolution: New buoy on fantail
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 8 August 2017 Resolved
Replace the line for the waterlight and the throwable line.
Action required: 705 - Other - as specified
Due 8 September 2017
Resolved 28 September 2017
Resolution: Line renewed.
Lifesaving › Rescue Boat › Hull (rigid)
Issued 8 August 2017 Resolved
Repair damage to aft keel of rescue boat
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 October 2017
Resolved 28 September 2017
Resolution: Examined repaired keel.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 8 August 2017 Resolved
Install a flame screen on the fuel vents located on the main deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 September 2017
Resolved 9 September 2017
Resolution: Corrected
Lifesaving › Rescue Boat › Markings
Issued 8 August 2017 Resolved
Provide the markings on the rescue boat iaw 46/199.176(a)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 September 2017
Resolved 3 January 2018
Resolution: Attended vessel. Markings in place.
Lifesaving › Launching Appliances › Davit
Issued 8 August 2017 Resolved
Weigh the rescue boat and then load test the davit to 110% of the rescue boat's weight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2017
Resolved 3 January 2018
Resolution: Attended vessel. Conducted weight test.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 9 August 2016 Resolved
Prove proper operation of E/R fire suppression system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 August 2016
Resolved 8 September 2016
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 9 August 2016 Resolved
Repair hole in keel cooler port void #5 wing tank.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 August 2016
Resolved 29 August 2016
Engineering › Steam Boiler (auxiliary/waste heat) › Automation Equipment
Issued 9 August 2016 Resolved
Prove proper operation of boiler low water cutout.
Action required: 705 - Other - as specified
Due 9 September 2016
Resolved 8 September 2016
Communications › Alarms/Indicators › High Water Alarm
Issued 9 August 2016 Resolved
Prove proper operation of high water temp sensor both MDE's.
Action required: 705 - Other - as specified
Due 9 September 2016
Resolved 8 September 2016
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 9 August 2016 Resolved
Prove proper operation of generator L/O alarm.
Action required: 705 - Other - as specified
Due 9 September 2016
Resolved 8 September 2016
Construction/Loadline › Structures › Transverse Bulkhead
Issued 9 August 2016 Resolved
Repair hole in bulkhead between stbd void #5 and void #6 wing tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 September 2016
Resolved 29 August 2016

Casualty record · 5

16 October 2004Routine · role: Involved in a Marine Casualty · activity 2241890
3 June 2010Routine · role: Involved in a Marine Casualty · activity 3759782
10 May 2012Routine · role: Involved in a Marine Casualty · activity 4313782
2 October 2015Routine · role: Moored/Anchored in Vicinity of Primary Subject · 1 dead · activity 5769814
3 April 2018Routine · role: Alleged Pollution Source · activity 6385610
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

EVERETT LIBBY (2004–2018). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.