Records from 2004 to 2025. Most recent: inspection, 25 August 2025.
Inspection history · 25
25 August 2025
Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8217574
11 June 2025
Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8166475
9 September 2024
Drydock Extension
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7999657
29 July 2024
DAPI Audit · Deficiency Check · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7959923
29 February 2024
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7873607
31 July 2023
Deficiency Check · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7746449
31 July 2023
Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7768729
16 March 2023
Re-Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7655172
20 July 2022
Internal Structural Exam · COI Inspection · MTSA Verification · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7512096
24 May 2022
DAPI Audit
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7459484
13 January 2022
Re-Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7379967
4 August 2021
MTSA Verification · Internal Structural Exam · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7265472
9 March 2021
Periodic Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7153690
16 December 2020
Periodic Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7116986
14 September 2020
Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7057935
15 July 2020
COI Inspection · MTSA Verification · DAPI Audit
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7007173
19 September 2019
Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6815520
22 July 2019
MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6758427
28 March 2019
Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6653349
23 July 2018
COI Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6487981
6 July 2018
Re-Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6469096
3 April 2018
Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6385610
31 July 2017
Deficiency Check · MTSA Verification · Hull Examination · DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6226510
28 July 2017
Administrative Inspection · Internal Structural Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6223466
9 August 2016
MTSA Verification · COI Inspection · Administrative Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5947932
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 July 2024
Resolved
Provide annual service report for pocket boiler, last inspection was Feb 2023.
Action required: 705 - Other - as specified
Due 29 August 2024
Resolved 10 September 2024
Resolution: Annual service completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 29 July 2024
Resolved
Repair / replace exhaust leak elbow 90 deg over 20 KW generator.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2024
Resolved 6 August 2024
Resolution: Repairs completed to exhaust system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 29 July 2024
Resolved
Repair air shut down stop gasket.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2024
Resolved 6 August 2024
Resolution: New air stop gasket installed, test sat.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 29 July 2024
Resolved
Provide copy of COD on vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2024
Resolved 29 August 2024
Resolution: Original document on vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 29 July 2024
Resolved
Provide 03 Orange smoke signals.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2024
Resolved 6 August 2024
Resolution: 03 Orange smoke signals provided on vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 29 July 2024
Resolved
Repair / replace IBA aft port side cradle.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2024
Resolved 12 September 2024
Resolution: Primary life saving requirement are reduced and meets pax carriage.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 July 2024
Resolved
Provide hydro report of CO2 bottles.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2024
Resolved 10 September 2024
Resolution: Annual service report completed.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 29 July 2024
Resolved
Provide drills to include Fire, MOB, and abandon ship.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2024
Resolved 10 September 2024
Resolution: New ownership to complete at NTZ inspection.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 29 July 2024
Resolved
Replace expired components in First Aid Kits.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2024
Resolved 10 September 2024
Resolution: First Aid kit meets published content requirements.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 29 July 2024
Resolved
Provide servicing of all IBA's on vessel, vessel is restricted to 150 total persons, provided 1 50 man IBA on port side 75 persons, 1 50 man IBA on stbd side of vessel 75 persons with a total of 150 persons.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2024
Resolved 10 September 2024
Resolution: All IBA's (02) 50 man are in service dates.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 31 July 2023
Resolved
Replace expired HRU. Vessel restricted to operating NMT 3 miles from land until corrected.
Action required: 705 - Other - as specified
Due 31 August 2023
Resolved 2 August 2023
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 31 July 2023
Resolved
Provide proof of annual servicing of Fire Extinguishing equipment.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 August 2023
Resolved 8 August 2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 August 2022
Resolved
Repair/Replace Fire Axe bracket, starboard forward.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2022
Resolved 14 September 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 4 August 2021
Resolved
Engine room door found not to be weather tight.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 September 2021
Resolution: Door repaird to wx tight condition.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 4 August 2021
Resolved
Scheduled annual inspection of both fixed and portable fire fighting equipment.
Action required: 10 - Deficiency Rectified
Due 4 August 2021
Resolved 4 August 2021
Resolution: Technicians attended vessel to complete service, report available, test sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 August 2021
Resolved
Install life jackets at all watch stations.
Action required: 10 - Deficiency Rectified
Due 4 August 2021
Resolved 4 August 2021
Resolution: 2 addition life jackets installed at watch stations.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 6 August 2020
Resolved
Modify CO2 cage as discussed to provide ready access and clear instruction.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2020
Resolved 14 August 2020
14 - Pollution Prevention › 142 - MARPOL Annex II › Vent. Procedures/equipment
Issued 6 August 2020
Resolved
Provide/Prove operation of containment plugs at stbd fill & vent.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2020
Resolved 14 August 2020
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 August 2020
Resolved
Label Fire Extinguishing station in stbd aft pax cabin (new bulkhead panel) as well as Extinguisher #3.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2020
Resolved 14 August 2020
10 - Safety of Navigation › N/A - No Subsystem › Bridge operation
Issued 6 August 2020
Resolved
Prove operation of SPP call bell with engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2020
Resolved 17 August 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 6 August 2020
Resolved
Replace port MDE high temp sensoe alarm and 20kw generator high temp sensor.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2020
Resolved 17 August 2020
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 6 August 2020
Resolved
Provide fire servicing report.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2020
Resolved 18 August 2020
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 30 August 2019
Resolved
Vessel to install a USCG approved rescue boat as per OCMI letter issued by SNNE. Vsl currently has a row boat and manual falls that have been deemed insufficent by the local OCMI.
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 September 2020
Resolution: Exemption Request approved.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 August 2019
Resolved
Provide new ring buoy (fwd stbd side).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2019
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 August 2019
Resolved
Stencil corrected instructions for fixed CO2 system. (Pull indicators for cylinder head and stop valves are incorrectly identified/switched).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 28 March 2019
Resolved
E-Generator will not stay running, genset shutdowns due to low oil pressure.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2019
Resolution: Corrected
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 March 2019
Resolved
Repair the Temperature gauage for the 20KW Genset
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2019
Resolved 1 April 2019
Resolution: Corrected
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 28 March 2019
Resolved
Replace the glass in the valve control pull station on the main deck.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2019
Resolved 1 April 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 March 2019
Resolved
Provide a valid FCC Station License and a Bridge to Bridge cert.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2019
Resolved 17 May 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 28 March 2019
Resolved
Move the embarkation lights to illuminate the IBAs and life raft stations.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2019
Resolved 1 May 2019
Resolution: corrected
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 March 2019
Resolved
Repair the electric bilge pump; pump would not move water.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2019
Resolved 1 May 2019
Resolution: corrected
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 8 August 2018
Resolved
Repair the high water temperature sensor on the 20KW Genset.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2018
Resolved 28 March 2019
Resolution: Corrected
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 August 2018
Resolved
Replace the flexible service loops (hoses) from the CO2 bottles to the CO2 mainifold.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2018
Resolved 27 September 2018
Resolution: Replaced
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 8 August 2018
Resolved
Repair the audible alarm for the main engine alarm panel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2018
Resolved 27 September 2018
Resolution: Cleared
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 August 2018
Resolved
Repair or replace the watt meter on the 20KW swithboard, meter is not working.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2018
Resolved 28 March 2019
Resolution: Meter is working
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 August 2018
Resolved
Locate and repair the ground on the 20KW genset, that is visible on the switchboard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2018
Resolved 27 September 2018
Resolution: Cleared
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 August 2018
Resolved
Provide a donning placard for the various types of PFDs onboard the vessel.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2018
Resolved 28 March 2019
Resolution: Corrected
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 8 August 2018
Resolved
Provide IMO symbols at the Ring Buoy and Liferaft locations
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2018
Resolved 28 March 2019
Resolution: Corrected
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 8 August 2018
Resolved
Conduct MOB & Fire drills to the satisfaction of USCG.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2018
Resolved 27 September 2018
Resolution: Cleared
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 July 2018
Resolved
Replace the expired portable fire extinguisher in the port pax seating area.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2018
Resolved 17 July 2018
Resolution: Corrected
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 17 July 2018
Resolved
Install the IBAs & L/R with an hydrostatic release and not using lifefloat weak links.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 August 2018
Resolution: Def issued in error, vls permitted to have weak links for L/F & BA iaw NVIC 4-86.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 17 July 2018
Resolved
Repair the GA in both pax seating areas.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 August 2018
Resolution: Repaired
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 July 2018
Resolved
Provide a Lifejacket donning placard in the 01 stbd jacket container box
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 August 2018
Resolution: Corrected
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 22 August 2017
Resolved
No homeport was listed on the ring buoys, ROCKPORT
Action required: 705 - Other - as specified
Due 17 September 2017
Resolved 5 September 2017
Resolution: Corrected
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 8 August 2017
Resolved
Provide testing of main engine's high temp alarm
Action required: 705 - Other - as specified
Due 8 September 2017
Resolved 15 August 2017
Resolution: Corrected.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 August 2017
Resolved
Replace the expired medicene in first aid kit
Action required: 705 - Other - as specified
Due 8 September 2017
Resolved 17 August 2017
Resolution: corrected
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 8 August 2017
Resolved
Provide a new donning placard in the stbd pax seating area.
Action required: 705 - Other - as specified
Due 8 September 2017
Resolved 17 August 2017
Resolution: corrected
Lifesaving › Lifebuoys › Serviceable
Issued 8 August 2017
Resolved
Replace the aft ring buoy on fantail.
Action required: 705 - Other - as specified
Due 8 September 2017
Resolved 5 September 2017
Resolution: New buoy on fantail
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 8 August 2017
Resolved
Replace the line for the waterlight and the throwable line.
Action required: 705 - Other - as specified
Due 8 September 2017
Resolved 28 September 2017
Resolution: Line renewed.
Lifesaving › Rescue Boat › Hull (rigid)
Issued 8 August 2017
Resolved
Repair damage to aft keel of rescue boat
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 October 2017
Resolved 28 September 2017
Resolution: Examined repaired keel.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 8 August 2017
Resolved
Install a flame screen on the fuel vents located on the main deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 September 2017
Resolved 9 September 2017
Resolution: Corrected
Lifesaving › Rescue Boat › Markings
Issued 8 August 2017
Resolved
Provide the markings on the rescue boat iaw 46/199.176(a)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 September 2017
Resolved 3 January 2018
Resolution: Attended vessel. Markings in place.
Lifesaving › Launching Appliances › Davit
Issued 8 August 2017
Resolved
Weigh the rescue boat and then load test the davit to 110% of the rescue boat's weight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2017
Resolved 3 January 2018
Resolution: Attended vessel. Conducted weight test.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 9 August 2016
Resolved
Prove proper operation of E/R fire suppression system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 August 2016
Resolved 8 September 2016
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 9 August 2016
Resolved
Repair hole in keel cooler port void #5 wing tank.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 August 2016
Resolved 29 August 2016
Engineering › Steam Boiler (auxiliary/waste heat) › Automation Equipment
Issued 9 August 2016
Resolved
Prove proper operation of boiler low water cutout.
Action required: 705 - Other - as specified
Due 9 September 2016
Resolved 8 September 2016
Communications › Alarms/Indicators › High Water Alarm
Issued 9 August 2016
Resolved
Prove proper operation of high water temp sensor both MDE's.
Action required: 705 - Other - as specified
Due 9 September 2016
Resolved 8 September 2016
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 9 August 2016
Resolved
Prove proper operation of generator L/O alarm.
Action required: 705 - Other - as specified
Due 9 September 2016
Resolved 8 September 2016
Construction/Loadline › Structures › Transverse Bulkhead
Issued 9 August 2016
Resolved
Repair hole in bulkhead between stbd void #5 and void #6 wing tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 September 2016
Resolved 29 August 2016