Records from 2007 to 2025. Most recent: inspection, 10 November 2025.
Inspection history · 23
10 November 2025
Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8266374
9 August 2024
Internal Structural Exam · Annual Inspection · Drydock Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7977589
3 November 2023
Annual Inspection · Re-Inspection · Examination of Repairs
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7819629
3 August 2022
COI Inspection · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7524299
13 July 2022
In-Service Inspection · Drydock Exam · Internal Structural Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7506138
14 June 2022
Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 7477883
4 April 2022
Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7427933
5 January 2022
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7375782
14 December 2021
Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7420457
30 December 2020
Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7119066
3 December 2020
Deficiency Check · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7105956
20 August 2020
Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7038742
21 July 2020
Examination of Repairs · In-Service Inspection · Internal Structural Exam · Drydock Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7012619
23 June 2020
Administrative Inspection · In-Service Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6984287
12 September 2019
Administrative Inspection · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6809843
27 September 2018
Administrative Inspection · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6552005
27 August 2018
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6524812
16 August 2018
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6514421
2 August 2018
In-Service Inspection · Deficiency Check · Drydock Exam · Administrative Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6498527
25 September 2017
COI Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6274115
3 July 2017
Deficiency Check · Damage Survey
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6206190
4 August 2016
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5962750
26 July 2016
Drydock Exam · In-Service Inspection · Internal Structural Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5955176
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 November 2023
Resolved
A vessel must be operated in accordance with the applicable laws and regulations and in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. Approx. 40 gallons of fuel oil mixture found in voids 2 center, 3 center and 4 port and starboard of the segmented bilge voids. Vessel is restricted from operations pending identification and resolution to source of fuel oil mixture.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 November 2023
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 November 2023
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the navigation rules. The all around white light was inoperable at the time of the inspection. Vessel is restricted to day time operations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2023
Resolved 6 December 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 August 2022
Resolved
Ring buoy's grab line is dry rotted and disintegrated.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 10 August 2022
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 December 2021
Resolved
Replace plastic receptacle with a non-combustible trash bin.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 April 2022
Resolution: Photo received of non-combustible trashcan on main deck.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 December 2021
Resolved
Adult/children life jackets must be separated and stowage location marked.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 April 2022
Resolution: Photo received.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 24 December 2021
Resolved
Replace missing window glass cover in washroom with new to as original to prevent ingress of water from rain or seas.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 April 2022
Resolution: Photo of new window installed in washroom.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 24 December 2021
Resolved
Re-stencil faded warning sign near pull handle for pre-engineered fire suppression system to prevent persons or passengers from accidentally activating system into engine room compartment.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 April 2022
Resolution: Photo of pull station remarked.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 December 2021
Resolved
Replace crazed port side window with new at dry dock due in August 2022.
Action required: 705 - Other - as specified
Resolved 3 November 2023
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 24 December 2021
Resolved
Faded/unreadable vessel's name on life jackets. Remark adult and children life jackets with vessel’s name in block letters/2" minimum.
Action required: 10 - Deficiency Rectified
Resolved 24 December 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 December 2021
Resolved
Missing double clamp on overboard submersible discharge hoses in engine room compartment.
Action required: 10 - Deficiency Rectified
Resolved 24 December 2021
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 24 December 2021
Resolved
Renew faded SOLAS tape on ring buoy.
Action required: 10 - Deficiency Rectified
Resolved 24 December 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 December 2021
Resolved
Prior to carrying passengers for hire, replace inoperable float switch for submersible overboard pump with new and prove operation.
Action required: 10 - Deficiency Rectified
Resolved 24 December 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 December 2020
Resolved
Wiring to the toilet pump was improperly installed in the passenger accommodation area. Rectify deficiency within 7 days.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 December 2020
Resolved 10 December 2020
Resolution: Wiring repaired with heat shrink.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 December 2020
Resolved
The passenger accommodation space and the toilet space are missing light covers. Rectify deficiency within 7 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 December 2020
Resolved 31 December 2020
Resolution: Light covers replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 4 December 2020
Resolved
Water light battery for life ring buoy is expired and in need of replacement. Rectify deficiency within 7 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 December 2020
Resolved 10 December 2020
Resolution: New water light ordered.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 December 2020
Resolved
The port side grab rail on the stern of the vessel to assist divers entering the water has a cracked weld at the base.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 December 2020
Resolved 30 December 2020
Resolution: Grab rail welded and repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 September 2019
Resolved
A portable hand bilge pump must be capable of pumping water from all watertight compartments and provided with suitable suction hose capable of reaching the bilge of each watertight compartment and discharging overboard. The emergency hand bilge pump is not functioning as designed and missing a discharge hose.
Action required: 705 - Other - as specified
Due 20 September 2019
Resolved 14 September 2019
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 27 September 2018
Resolved
Replace expired battery in the water float light IAW 46 CFR 185.726(d), battery was installed in August 2015.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2018
Resolved 30 September 2018
Resolution: New battery purchased and installed. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 27 September 2018
Resolved
Replace life ring buoy due to wasted condition IAW 46 CFR 180.70(b)(1).
Action required: 10 - Deficiency Rectified
Due 27 September 2018
Resolved 27 September 2018
Resolution: New life ring was procured, marked and installed before departing from the inspection, corrected on the spot.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 28 September 2017
Resolved
Origional Certificate of Documentaion not provided.
Action required: 705 - Other - as specified
Due 28 September 2017
Resolved 12 October 2017
Documentation › Certificates/Documents › FCC SSL
Issued 28 September 2017
Resolved
Valid FCC Station for licensee not available.
Action required: 705 - Other - as specified
Due 28 September 2017
Resolved 12 October 2017
Electrical › Electric Supply System (service) › Cable
Issued 28 September 2017
Resolved
Remove dead-end wiring in way of operator station console.
Action required: 705 - Other - as specified
Due 20 October 2017
Resolved 20 October 2017
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 28 September 2017
Resolved
Air vents for machinery space wasted.
Action required: 705 - Other - as specified
Due 6 October 2017
Resolved 12 October 2017
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 28 September 2017
Resolved
Some items observed expired. Other items due to expire in Oct17.
Action required: 705 - Other - as specified
Due 20 October 2017
Resolved 20 October 2017
Engineering › Bilge Water Management System › Pump
Issued 28 September 2017
Resolved
Automatic activiation switch not secured to vessel.
Action required: 705 - Other - as specified
Due 6 October 2017
Resolved 12 October 2017
Engineering › Bilge Water Management System › Hose
Issued 28 September 2017
Resolved
Double clamp all bilge hoses.
Action required: 705 - Other - as specified
Due 6 October 2017
Resolved 12 October 2017
Electrical › Lighting (service) › Lighting Fixture
Issued 28 September 2017
Resolved
Unauthorized/unapproved lighting installed on overhead of mainpassenger deck.
Action required: 705 - Other - as specified
Due 20 October 2017
Resolved 2 August 2018
Resolution: Lighting fixture has been removed, all sat.
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 28 September 2017
Resolved
Provide evidence of CG approval of flexible hose from turbocharger to crankcase on starboard engine.
Action required: 705 - Other - as specified
Due 6 October 2017
Resolved 12 October 2017
Fire Fighting › Fire Bucket › Capacity
Issued 28 September 2017
Resolved
Fire buckets onboard were observed to be of a 2 gallon capacity instead of required 2 1/2 gallon capacity.
Action required: 705 - Other - as specified
Due 6 October 2017
Resolved 12 October 2017
Communications › Alarms/Indicators › Bilge Alarm
Issued 28 September 2017
Resolved
Identify high bilge alarm at operators station.
Action required: 705 - Other - as specified
Due 6 October 2017
Resolved 12 October 2017
Documentation › Markings/Placards › Garbage Placard
Issued 28 September 2017
Resolved
MARPOL V placard missing.
Action required: 705 - Other - as specified
Due 6 October 2017
Resolved 12 October 2017
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 28 September 2017
Resolved
Storage / number markings wasted.
Action required: 705 - Other - as specified
Due 28 September 2017
Resolved 28 September 2017
Engineering › Shafting/Propeller Arrangements › Thrust Shaft
Issued 3 July 2017
Resolved
Starboard leg failed.
Action required: 705 - Other - as specified
Resolved 3 July 2017