MAURY USCG vessel records Sign in
← All vessels

ANTON TOPIC

ANTON TOPIC is a 1996 freight ship. The Coast Guard has recorded 30 inspections since 1996, most recently in September 2018, along with 18 deficiencies and 6 operational controls.

Records from 1996 to 2018. Most recent: inspection, 20 September 2018.

Built
1996
Last inspected
20 September 2018
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9107679 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
438403
Flag
LIBERIA
—
Maury page id
psix-438403

Inspections, by type

…with no type recorded12
Years with a record 14 calendar years (1996–2018)
The 30 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it26250 - Convention (Subpart B), Gross Ton
53181 - Displacement, Metric Ton
45496 - Dead Weight, Metric Ton
14198 - Convention (Subpart B), Net Ton
26250 - Regulatory (Subpart C or D), Gross Ton
14198 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 30

20 September 2018 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6544590
6 September 2018 ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination · Administrative Inspection · Deficiency Check · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6533613
8 May 2018 Deficiency Check · COE-Dockside
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6408988
18 January 2018 Ballast Water Examination · ISPS II Exam · PII Safety Exam · COE-Dockside
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6337415
17 May 2017 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6144678
24 May 2016 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5882717
17 May 2016 COE-Administrative
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5879857
13 May 2016 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5876355
16 August 2011 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4116999
23 July 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3538276
20 April 2009 Ballast Water Examination · ISPS I Exam · MARPOL Annex I Examination · PII Safety Exam · MARPOL Annex V Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3449346
12 March 2008 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3163102
15 March 2007 Random ISPS/MTSA/PSC
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2888238
17 January 2007 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2857326
6 November 2005 ISPS II Exam · ILO-147 Exam · MARPOL Annex V Examination · MARPOL Annex I Examination · PII Safety Exam · STCW 95 Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2529521
3 November 2005 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2528093
28 April 2005 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2344899
28 April 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2345306
24 April 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2341565
13 September 2004 NPV Safety Exam · ISPS II Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2194385
17 February 2004 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2007712
21 November 2003 MARPOL Annex I Examination · Annual Inspection · MARPOL Annex V Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1952127
15 May 2003 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1788170
19 March 2003 Security Inspection · Periodic Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1759545
13 March 2003 Type not recorded
No type recorded · Station Point Allerton · USCG Northeast District (CGD-NE) · Activity 1756978
9 October 2002 Annual Inspection · Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1685820
19 January 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 273904
18 January 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 273668
21 February 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 413050
19 July 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 393290

Deficiency record · 18

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Documentation-ISM
Issued 6 September 2018 Resolved
15110 - Documentation-ISM - The company should establish procedures to ensure that the ship is maintained in accordance with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. Due to a lack of proper procedures for the operation of the OWS, and no procedural requirement to document equipment nonconformity, the PSCO questions the adequacy and/or implementation of the vessel's SMS under the ISM code. An external audit is recommended to be conducted by the flag state or RO to determine whether the ship is operating in accordance with the ISM code. Provide decision to USCG within 30 days. - 74 SOLAS (14) IX/3.1 and ISM Code Part A/10.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2018
Resolved 9 September 2018
Resolution: ISM audit was conducted by flag on 06 Sep 2018.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 6 September 2018 Resolved
14107 - Oil discharge monitoring and control system - Oil filtering equipment... shall also be provided with arrangements to ensure that any discharge of oily mixtures is automatically stopped when the oil content of the effluent exceeds 15 ppm. In considering the design of such equipment and approvals, the administration shall have regard to the specification recommended by the organization. The automatic stopping device should consist of a valve arrangement installed in the effluent outlet line of the 15 ppm bilge separator which automatically diverts the effluent mixture from being discharged overboard back to the ship's bilges or bilge tank when the oil content of the effluent exceeds 15 ppm. Port state control officers found that the oily water separator's three way valve is not connected to the system because the valve stem is snapped and the air control system does not actuate the valve. The valve is rusted into the overboard position. - MARPOL Annex I/14.7
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 6 September 2018
Resolved 9 September 2018
Resolution: 3-way valve repaired to the satisfaction of class and attending PSCOs.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 September 2018 Resolved
02108 - Electrical installations in general - All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in a normal manner. Washing machine in crew laundry is not properly wired and poses safety hazard. Dead end wiring to light at work station in engine room poses safety hazard. - 74 SOLAS (04) II-1/45.1.3
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2018
Resolved 9 September 2018
Resolution: Washing machine wiring re-routed and properly connected. Dead end wiring to light at E/R work station secured.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 6 September 2018 Resolved
07103 - Division - decks, bulkheads and penetrations - In addition to complying with the specific provisions for fire integrity of bulkheads and decks mentioned elsewhere in this part; the minimum fire integrity of bulkheads and decks shall be as prescribed in tables 44.1 and 44.2. PSCO found approximately 18" (inch) penetration of the steel bulkhead into electrical store room. - 74 SOLAS (97) II-2/44.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 September 2018
Resolution: Attending PSCOs verified 18" penetration closed off with welded plate.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 September 2018 Resolved
02108 - Electrical installations in general - Fire doors in main vertical zones, bulkheads, and stairway enclosures shall... be self-closing. Upon inspection, three fire doors were observed to be not self-closing. - 74 SOLAS (97) II-2/30.4.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2018
Resolved 9 September 2018
Resolution: Fire doors adjusted and verified to be self-closing.
09 - Working and Living Conditions › 091 - Living Conditions › Drainage
Issued 6 September 2018 Resolved
09107 - Drainage - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship... will remain fit to proceed to sea. PSCO found deck drain piping in dry stores space has a temporary repair made of plastic. - 74 SOLAS (14) I/11a
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 September 2018
Resolution: Drainage piping in dry stores permanently repaired with metalic piping.
Engineering › Diesel Engine (propulsion-direct drive) › Pump, High Pressure (fuel injection)
Issued 18 January 2018 Resolved
1410-PROPULSION MAIN ENGINE-In a ship in which oil fuel is used, the arrangements for the storage, distribution, and utilization of the oil fuel shall be such as to ensure the safety of the ship and the persons on board. PSCO observed leaking from the from fuel pump on all cylinders of the main engine. SOLAS (74) 1997 CONS. II-2/15.1. ACTION TAKEN 60.a
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 18 January 2018
Resolved 22 January 2018
Resolution: PSC NOLA recieved a class report from LR statisfying the requirement.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 18 January 2018 Resolved
9900-OTHER (NOT CLEARLY HAZARDOUS)-After any survey of the ship has been completed, no change shall be made to the structural arrangements, machinery, equipment and other items covered by the survey. PSCO observed the presence of a broken fuel treatment/additive connected to the fuel pipe leading to the main engine. SOLAS(74)2014 CONS. I/11 ACTION TAKEN 16a
Action required: 705 - Other - as specified
Due 1 February 2018
Resolved 19 January 2018
Resolution: Recieved class report from LR attesting to the removal of the broken fuel treatment system.
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 17 May 2017 Resolved
Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of electrical power required by regualtion II-1/42 OR II-1/43 as appropriate. 74SOLAS (14) III/11.4 (40AC)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 17 May 2017
Resolved 8 May 2018
Operations/Management › Drills/Instruction › Abandon Ship
Issued 24 May 2016 Resolved
2025 - Abondon Ship Drills - The drills of the crew shall take place within 24 hours of the ship leaving port if more than 25% of the crew have not participated in abandon ship drills on board that particular ship in the previous month. Lowering of a lifeboat was not conducted as part of the abandon ship drill as required.
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 24 May 2016
Resolution: An additional abandon ship drill was conducted to the satisfaction of the Coast Guard.
Lifesaving › Lifeboat
Issued 21 November 2003 Resolved
Due to lifeboats not being self-righting, affix retro-reflective tape to the undersides of lifeboats as per IMO instructions to the satisfaction of class society. LEGACY COMPONENT DESC: Markings
Condition: Unknown
Due 21 December 2003
Resolved 17 February 2004
Resolution: Determined that the life boats are self righting and boats already have mininum stardard of reflective tape. Provided the master with recommended reflected tape applications. (Res. A.658(16))
Electrical › Lighting (service)
Issued 21 November 2003 Resolved
Replace missing cages on light fixtures throughout ship and repair broken fixtures in bosun stores up foward to the satisfaction of attending US Coast Guard inspector. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Due 21 December 2003
Resolved 17 February 2004
Resolution: All light fixtures and cages throughout the ship were in proper condition.
Electrical › Electrical Distribution System (emergency)
Issued 21 November 2003 Resolved
Properly repair ground shown on emergency generator switchboard to the satisfaction of US Coast Guard. LEGACY COMPONENT DESC: Switchboard
Due 21 December 2003
Resolved 17 February 2004
Resolution: Reviewed interim certificate dated 16FEB2004 issued by Class (Lloyd''s Register) pertaining to the repair of ground on the Emergency Switchboard. Tested the ground indicator and determined it to be properly operating.
Lifesaving › Lifeboat Equipment
Issued 9 October 2002 Resolved
STBD LIFEBOAT MISSING (16) FOOD RATIONS, TO MEET THE TOTAL CAPACITY. LEGACY COMPONENT DESC: Food Ration
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 9 November 2002
Resolved 14 October 2002
Resolution: Rcvd faxed copy of receipt of purchase, also verified by MSO Philadelphia personnel during follow-up exam on 14Oct02.
Navigation › Piloting/Steering
Issued 9 October 2002 Resolved
VESSEL MISSING REQUIRED NTM'S TO MAKE CORRECTIONS TO THEIR CHARTS, LIGHT LIST, & COATS PILOT; FROM WEEK 34 TO THE PRESENT. LEGACY COMPONENT DESC: Local Notices to Mariners
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 October 2002
Resolution: Rcvd faxed copy of reciept of purchase , also verified by MSO Philadelphia personnel during follow-up exam on 14Oct02.
Fire Fighting › Nozzles
Issued 9 October 2002 Resolved
NOZZLE MISSING FROM FIRE HOSE BOX LOCATED ON THE MAIN DECK, STBD-SIDE, BETWEEN CARGO HOLDS #2 & #3. LEGACY COMPONENT DESC: Number
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 9 November 2002
Resolved 14 October 2002
Resolution: Rcvd faxed copy of reciept of purchase, also verified by MSO Philadelphia personnel during follow-up exam on 14Oct02.
Fire Fighting › Fire Hydrants
Issued 9 October 2002 Resolved
ALL HYDRANTS ON THE OPEN DECKS ARE MISSING PROTECTIVE CAPS. LEGACY COMPONENT DESC: Condition
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 9 November 2002
Resolved 14 October 2002
Resolution: Rcvd faxed copy of reciept of purchase, also verified by MSO Philadelphia personnel during follow-up exam on 14Oct02.
Fire Fighting
Issued 18 January 2000 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 21 January 2000
Resolved 21 January 2000

Ownership record