DESTIN PRINCESS

DESTIN PRINCESS is a 1996 passenger vessel (inspected). The Coast Guard has recorded 53 inspections since 1996, most recently in January 2026, along with 71 deficiencies and 3 casualty investigations between 2014 and 2022.

Records from 1996 to 2026. Most recent: inspection, 12 January 2026.

Built
1996
Last inspected
12 January 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCW9379
438428
Flag
UNITED STATES
367141910
Maury page id
psix-438428

Inspections, by type

…with no type recorded11
Years with a record 28 calendar years (1996–2026)
The 53 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)64.2 ft × 22.5 ft × 8.2 ft
Registered tonnagegross 63 / net 50
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderK T BOATWORKS INC · FREEPORT, FL, UNITED STATES · built 1996
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationTwin Hull
Hailing portDESTIN, FL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 24 April 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it63 - Simplified, Gross Ton
50 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCW9379MMSI 367141910 · active · compulsorily equipped · granted 13 October 2016, expires 7 November 2026
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 53

12 January 2026 Vessel Attendance · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8295739
10 December 2025 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8276198
6 January 2025 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8059887
22 May 2024 Administrative Inspection · Construction Oversight
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7917271
8 January 2024 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7847888
28 November 2023 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7830726
1 December 2022 COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7598369
23 August 2022 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7542295
18 August 2022 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7549028
22 February 2022 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 7400343
25 January 2022 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7385835
16 February 2021 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7142922
25 August 2020 Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7042536
20 February 2020 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6912739
29 April 2019 DAPI Audit · Examination of Repairs · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6673240
23 October 2018 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6570715
21 October 2018 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6574495
14 August 2018 Deficiency Check · Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6511417
5 December 2017 COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6314941
27 January 2017 Deficiency Check · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6078621
9 August 2016 Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5963341
8 February 2016 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5810451
4 October 2014 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5002073
12 August 2014 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4952793
5 January 2012 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4218562
17 August 2011 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 4119257
1 February 2011 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3971618
16 February 2010 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3679439
7 January 2009 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3387557
25 August 2008 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3305594
19 November 2007 COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3104455
8 January 2007 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2863376
8 August 2006 Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2739758
16 November 2004 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2241570
10 August 2004 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2162430
29 January 2004 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1992849
24 October 2003 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 1935656
24 October 2003 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1948221
24 March 2003 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 1762707
3 December 2002 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1701195
18 November 2002 COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1706837
27 November 2001 Re-Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1405297
1 March 2001 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1074562
23 February 2001 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1076635
22 February 2001 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1422023
21 September 2000 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 1516359
2 December 1999 COI Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1469616
15 September 1999 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1401135
14 September 1999 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 1510054
2 December 1998 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1397032
11 December 1997 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1442645
4 December 1996 Initial Certification · Initial Construction-Excluding Oversight · Plan Review "T" Boat · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1460049
15 November 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1178056

Deficiency record · 71

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 8 January 2024 Resolved
An interconnected fire detector must be installed in all areas where passengers and crew have access. No spaces are equipped with detectors. The vessel operations are restricted to not more than 20NM from shore.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2024
Resolved 25 January 2024
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 August 2022 Resolved
Inspect fire safety equipment in accordance with 46 CFR 176.810. Pre-engineered fire suppression systems were inoperative.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 September 2022
Resolution: Received video of satisfactory operation of systems.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 20 February 2020 Resolved
The life floats in series did not have the appropriate length line between them to launch from the 2nd deck. Provide the appropriate length line to ensure the 03 life floats could be safely launched.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 27 February 2020
Resolved 20 February 2020
Resolution: Vessel provided photographs that new line of the appropriate length had been installed to ensure each life float could be launched individually.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 20 February 2020 Resolved
The floating waterlights on each of the 03 lifefloats is required to be a minimum of 18 feet n length. Length the line and ensure it is attached around the body of the buoy.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 27 February 2020
Resolved 20 February 2020
Resolution: Vessel sent satisfactory photographic evidence that the floating waterlight lines were the appropriate length.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 February 2020 Resolved
The port side engine room 40-B extinguisher was not properly charge and teh gauge was in the red. Replace, refill, or repair the extinguisher
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 27 February 2020
Resolved 20 February 2020
Resolution: Fire servicing technician arrived during the inspection and serviced extinguisher to ensure satisfactory condition.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 20 February 2020 Resolved
Program MMSI number into primary VHF radio.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2020
Resolved 20 February 2020
Resolution: Vessel provided photograph indicating that the MMSI number had been programed into the primary VHF radio installation
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 20 February 2020 Resolved
Vessel's charts were outdated and did not cover the entire operating area. Provide updated charts.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2020
Resolved 26 February 2020
Resolution: Owner provided photograph that new Oceangraffix chart, updated to this year 2020, had been received and was onboard for use.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 20 February 2020 Resolved
Vessel did not have current tables for operating area. Provided appropriate current tables.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2020
Resolved 21 February 2020
Resolution: Upon review of NOAA's website, there is no current station applicable to the vessel's operating area and thus the vesssel does not need current tables.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 20 February 2020 Resolved
Post COI in conspicuous place where passengers.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2020
Resolved 20 February 2020
Resolution: Vessel provided photograph that the COI had been posted in the main accomodation area of the vessel for review by the passengers
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 February 2020 Resolved
Lights indicating the operation of bilge pumps must be visible at the opearting station. Replace inoperable LED lights
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2020
Resolved 26 February 2020
Resolution: Owner provided photograph showing that all of the inoperable lights indicating bilge pump operation had been replaced and were properly illuminating.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 29 April 2019 Resolved
Replace fire extinguisher in accommodation space, due to low charge.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2019
Resolved 2 May 2019
Resolution: Replaced with new extinguisher.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 29 April 2019 Resolved
Secure life floats in tandem or provide individual painter lines for each life float.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2019
Resolved 2 May 2019
Resolution: Life floats properly secured.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 29 April 2019 Resolved
Repair damage to lifefloat corner. Vessel is limited to carrying 30 persons on board until deficiency is rectified.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2019
Resolved 2 May 2019
Resolution: Lifefloat repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 29 April 2019 Resolved
Repair wasted grab lines on life floats. Vessel is limited to carrying 30 persons on board until deficiency is rectified.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2019
Resolved 2 May 2019
Resolution: Grab lines replaced.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 29 April 2019 Resolved
Replace EPIRB battery. Vessel is limited to operating no more than 3 NM from shore.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2019
Resolved 3 May 2019
Resolution: New battery provided.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 29 April 2019 Resolved
Provide DOT alcohol testing devices. Vessel is limited to operating no more than 2 hours from homeport.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2019
Resolved 2 May 2019
Resolution: Alcohol test strips provided.
05 - Radio Communications › N/A - No Subsystem › Performance standards for radio equipment
Issued 29 April 2019 Resolved
Provide updated Safety Radio Telephony Certificate.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2019
Resolved 2 May 2019
Resolution: FCC safety radiotelephony certificate provided.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 29 April 2019 Resolved
Provide cap for sink drain overboard in starboard engine room .
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2019
Resolved 2 May 2019
Resolution: Cap provided.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 29 April 2019 Resolved
Provide proper gaskets for aft hatches.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2019
Resolved 2 May 2019
Resolution: Gaskets provided.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 29 April 2019 Resolved
Secure life float painter casing to the deck with appropriate sized screws.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2019
Resolved 2 May 2019
Resolution: Painter secured.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 29 April 2019 Resolved
Repair autopilot steering system leak under the bridge control panel.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2019
Resolved 2 May 2019
Resolution: Leak repaired.
Engineering › Engine Controls (Electric/Electronic) › Circuit Board
Issued 31 January 2017 Resolved
Replace gage panel housing enclosure on port main engine
Action required: 705 - Other - as specified
Due 15 February 2017
Resolved 15 February 2017
Resolution: Vessel renewed gage panel
Stability › Watertight Integrity › Weathertight Enclosure
Issued 31 January 2017 Resolved
Repair fiberglass surface under port aft scuttle.
Action required: 705 - Other - as specified
Due 15 February 2017
Resolved 15 February 2017
Resolution: Vessel repaired scuttle
Construction/Loadline › Penetrations › Gasket
Issued 9 August 2016 Resolved
no gasket material
Action required: 705 - Other - as specified
Due 9 August 2016
Resolved 9 August 2016
Resolution: Gasket material was added
Lifesaving › Lifefloat › Serviceable
Issued 8 February 2016 Resolved
Provide Serviceable Life Floats for Vessel, 45 persons.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 February 2016
Resolved 25 February 2016
Stability › Watertight Integrity › General
Issued 8 February 2016 Resolved
New gaskets on all water tight hatches.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 February 2016
Resolved 25 February 2016
Resolution: Installed.
Communications › Radio Communications › VHF Radiotelephone
Issued 1 February 2011 Resolved
Provide a radio operator permit for the Captain of the vessel.
Due 22 February 2011
Resolved 7 March 2011
Fire Fighting › Fixed Gas Fire Extinguishing System › Control Valve
Issued 1 February 2011 Resolved
Demonstrate proper operation to secure the generator with the fixed fire fighting system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 March 2011
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 1 February 2011 Resolved
Replace/repair stbd visual high water alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 March 2011
Communications › Radio Communications › EPIRB
Issued 16 February 2010 Resolved
Vessel EPIRB registration was out of date.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 February 2010
Communications › Radio Communications › EPIRB
Issued 16 February 2010 Resolved
Hydrostatic release on EPIRB was out of date.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 February 2010
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 16 February 2010 Resolved
B-II portable extinguisher was discharged.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 February 2010
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 16 February 2010 Resolved
Provide/ Demonstrate proper operation of fixed fire fighting system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 February 2010
Navigation › Piloting/Steering › Coast Guard Light List
Issued 7 January 2009 Resolved
Provide current publications (Coast Pilot [name withheld], Tide Tables).
Due 7 February 2009
Resolved 8 January 2009
Construction/Loadline › Structures › Deck Plating
Issued 25 August 2008 Resolved
Replace anchor locker floor starboard side of engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 August 2008
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 25 August 2008 Resolved
Remove debris in forward bilges.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 August 2008
Engineering › Steering Gear System › Ram
Issued 25 August 2008 Resolved
Provide pin or double nut for port and starboard steering rams.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 August 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 August 2008 Resolved
Replace straps for wiring in port lazerette.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 August 2008
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 8 January 2007 Resolved
Provide bonding cables for port/starboard fuel oil storage tanks. 46CFR183
Action required: 705 - Other - as specified
Due 8 February 2007
Resolved 25 January 2007
Operations/Management › Pollution › Control of Discharge of Oil
Issued 8 January 2007 Resolved
Remove oily waste from under generator. 46CFR183/185
Action required: 705 - Other - as specified
Due 8 February 2007
Resolved 25 January 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Bedplate
Issued 8 January 2007 Resolved
Aft engine mounts for Aux. generator found wasted and loose. Replace in kind. 46CFR182
Action required: 705 - Other - as specified
Due 8 February 2007
Resolved 25 January 2007
Lifesaving › Hand Flares › Storage
Issued 8 January 2007 Resolved
Provide distress signals box of suitable size and color, marked DISTRESS SIGNALS. 46CFR185.614
Action required: 705 - Other - as specified
Due 8 February 2007
Resolved 25 January 2007
Electrical › Electrical Distribution System (service) › Junction Box
Issued 8 January 2007 Resolved
Install suitable junction boxes for electric bilge pumps & high level alarms at point of electrical splices. 46CFR183
Action required: 705 - Other - as specified
Due 8 February 2007
Resolved 25 January 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Crankshaft
Issued 8 January 2007 Resolved
Install machinery guards & propulsion shaft guards. 46CFR177
Action required: 705 - Other - as specified
Due 8 February 2007
Resolved 25 January 2007
Communications › Radio Communications › EPIRB
Issued 8 January 2007 Resolved
Service EPIRB (replace broken activation tab). 46CFR180.64
Action required: 705 - Other - as specified
Due 8 February 2007
Resolved 25 January 2007
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 8 August 2006 Resolved
Replace the port and starboard aft cutlass bearings in accordance with 46 CFR 176.630.
Action required: 705 - Other - as specified
Due 8 September 2006
Resolved 30 August 2006
Resolution: Replaced the port and starboard aft cutlass bearings.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 8 August 2006 Resolved
Provide and install gaskets for all hatches in accordance with 46 CFR 176.800
Action required: 705 - Other - as specified
Due 8 September 2006
Resolved 30 August 2006
Resolution: Provided and installed gaskets for all hatches.
Fire Fighting › Means of Escape › Blocked
Issued 8 August 2006 Resolved
Make the emergency escape hatches operational from both sides in accordance with 46 CFR 177.500.
Action required: 705 - Other - as specified
Due 8 September 2006
Resolved 30 August 2006
Resolution: Made the emergency escape hatches operational from both sides.
Construction/Loadline › Penetrations › Valve Flange
Issued 8 August 2006 Resolved
Make through hull fitting for the MSD (gate valve) ready and visible for inspection in accordance with 46 CFR 176.610.
Action required: 705 - Other - as specified
Due 8 September 2006
Resolved 30 August 2006
Resolution: Made through hull fitting for the MSD (gate valve) ready and visible for inspection.
Construction/Loadline › Structures › Deck Plating
Issued 8 August 2006 Resolved
Make repairs to areas in the hull/deck where saltwater is entering both the port and starboard engine room in accordance with NVIC 8-87.
Action required: 705 - Other - as specified
Due 8 September 2006
Resolved 30 August 2006
Resolution: Made repairs to areas in the hull/deck where saltwater is entering both the port and starboard engine room.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 August 2006 Resolved
Provide and install guards over rotating machinery on both port and starboard main engines in accordance with 46 CFR 177.960.
Action required: 705 - Other - as specified
Due 8 September 2006
Resolved 30 August 2006
Resolution: Provided and installed guards over rotating machinery on both port and starboard main engines.
Fire Fighting › Remote Fuel Shutoff › General
Issued 8 August 2006 Resolved
Prove proper operation of emergency fuel shutoff on port and starboard fuel tanks in accordance with 46 CFR 182.455.
Action required: 705 - Other - as specified
Due 8 September 2006
Resolved 30 August 2006
Resolution: Proved proper operation of emergency fuel shutoff on port and starboard fuel tanks.
Engineering › Fuel Oil Service System › Flange
Issued 8 August 2006 Resolved
Make repairs to fuel oil leak on the port main engine in accordance with 46 CFR 176.804.
Action required: 705 - Other - as specified
Due 8 September 2006
Resolved 30 August 2006
Resolution: Made repairs to fuel oil leak on the port main engine.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 8 August 2006 Resolved
Properly mount the control box for the port main engine in accordance wtih 46 CFR 176.806.
Action required: 705 - Other - as specified
Due 8 September 2006
Resolved 30 August 2006
Resolution: Properly mounted the control box for the port main engine.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 8 August 2006 Resolved
Make permanent repairs to fixed seating on the bow where it's pulling away from the bulkhead in accordance with 46 CFR 177.820.
Action required: 705 - Other - as specified
Due 8 September 2006
Resolved 30 August 2006
Resolution: Made permanent repairs to fixed seating on the bow where it''''s pulling away from the bulkhead.
Construction/Loadline › Structures › Manhole
Issued 8 August 2006 Resolved
Properly attach the starboard forward peak hatch in accordance with 46 CFR 179.360.
Action required: 705 - Other - as specified
Due 8 September 2006
Resolved 30 August 2006
Resolution: Properly attached the starboard forward peak hatch.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 8 August 2006 Resolved
Remove all paint from the berthing compartments in accordance with 46 CFR 177.405.
Action required: 705 - Other - as specified
Due 8 September 2006
Resolved 30 August 2006
Resolution: Removed all paint from the berthing compartments.
Construction/Loadline › Structures › Superstructure
Issued 8 August 2006 Resolved
Make repairs to the gunwhale in accordance with 46 CFR 177.900.
Action required: 705 - Other - as specified
Due 8 September 2006
Resolved 30 August 2006
Resolution: Made repairs to the gunwhale.
Construction/Loadline › Hull › Hull Plating
Issued 8 August 2006 Resolved
Properly prep marked areas on the hull by grinding out old/deteriorated glass and make ready for inspection prior to application of new glass in accordance with NVIC 8-87.
Action required: 705 - Other - as specified
Due 8 September 2006
Resolved 30 August 2006
Resolution: Properly prepared marked areas on the hull by grinding out old/deteriorated glass and make ready for inspection prior to application of new glass.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 16 November 2004 Resolved
Provide logbook to document training and lifesaving equipment maintenance. 46 CFR 185.420.
Action required: 705 - Other - as specified
Due 16 December 2004
Resolved 14 December 2004
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 16 November 2004 Resolved
Repair navigation lights. 46 CFR 183.420.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 December 2004
Resolved 14 December 2004
Communications › Radio Communications › EPIRB
Issued 16 November 2004 Resolved
Install EPIRB in float free arrangement. 46 CFR 180.15g.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 December 2004
Resolved 14 December 2004
Construction/Loadline
Issued 22 February 2001 Resolved
Install bilge high level alarms in lazarettes.
Condition: Unknown
Due 22 February 2001
Resolved 22 February 2001
Lifesaving
Issued 15 September 1999 Resolved
46 CFR 180.64 - Renew EPIRB Hydrostatic release.
Condition: Unknown
Due 28 September 1999
Resolved 6 December 1999
Lifesaving
Issued 15 September 1999 Resolved
46 CFR 160.041 and 46 CFR 184.710 - Provide onboard and maintain a USCG approved First Aid Kit.
Condition: Unknown
Due 28 September 1999
Resolved 6 December 1999
Lifesaving
Issued 15 September 1999 Resolved
46 CFR 185.730 - Vsl's Inflatable Buoyant Apparatus needs to be inspected on a 12 month basis.
Condition: Unknown
Due 28 September 1999
Resolved 6 December 1999
Construction/Loadline
Issued 15 September 1999 Resolved
46 CFR 182.520 - Renew bilge pumps automatic floats to original condition.
Condition: Unknown
Due 28 September 1999
Resolved 6 December 1999
Fire Fighting
Issued 15 September 1999 Resolved
46 CFR 181.400 - Make vapor tight the boundaries leading down into the engine room.
Condition: Unknown
Due 28 September 1999
Resolved 6 December 1999
Lifesaving
Issued 15 September 1999 Resolved
46 CFR 180.71(a) - Provide onboard the required amount of PFDs per COI.
Condition: Unknown
Due 28 September 1999
Resolved 6 December 1999
Navigation
Issued 4 December 1996 Resolved
PROVIDE FOR NEW MAGNETIC COMPASS INSTALLATION, A COMPASS DEVIATION TABLE.
Condition: Unknown
Due 4 December 1996
Resolved 4 December 1996
Accommodation/Occupational Safety
Issued 4 December 1996 Resolved
PRIOR TO CARRYING PASSENGERS ON AN OVERNIGHT VOYAGE, COMPLETE OUTFITTING OFBOTH PASSENGER ACCOMODATION AREAS & SCHEDULE INSPECTION OF THOSE AREAS. ALSO INSURE THAT ALL MATTRESSES MEET 46 CFR 177.405(g)(1)or(2). ENSURE ALL EMERGENCY ESCAPES ARE PROPERLY RELABLED AFTER AREA IS PAINTED.
Condition: Unknown
Due 4 December 1996
Resolved 4 December 1996

Casualty record · 3

4 October 2014Routine · role: Involved in a Marine Casualty · 1 injured · activity 5002073
21 October 2018Routine · role: Involved in a Marine Casualty · activity 6574495
18 August 2022Routine · role: Involved in a Marine Casualty · activity 7549028
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.