Records from 2014 to 2026. Most recent: inspection, 12 January 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 22
12 January 2026
Vessel Attendance · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8295739
10 December 2025
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8276198
6 January 2025
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8059887
22 May 2024
Administrative Inspection · Construction Oversight
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7917271
8 January 2024
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7847888
28 November 2023
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7830726
1 December 2022
COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7598369
23 August 2022
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7542295
18 August 2022
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7549028
22 February 2022
Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 7400343
25 January 2022
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7385835
16 February 2021
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7142922
25 August 2020
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7042536
20 February 2020
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6912739
29 April 2019
DAPI Audit · Examination of Repairs · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6673240
23 October 2018
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6570715
21 October 2018
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6574495
14 August 2018
Deficiency Check · Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6511417
5 December 2017
COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6314941
27 January 2017
Deficiency Check · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6078621
9 August 2016
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5963341
8 February 2016
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5810451
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 8 January 2024
Resolved
An interconnected fire detector must be installed in all areas where passengers and crew have access. No spaces are equipped with detectors. The vessel operations are restricted to not more than 20NM from shore.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2024
Resolved 25 January 2024
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 August 2022
Resolved
Inspect fire safety equipment in accordance with 46 CFR 176.810. Pre-engineered fire suppression systems were inoperative.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 September 2022
Resolution: Received video of satisfactory operation of systems.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 20 February 2020
Resolved
The life floats in series did not have the appropriate length line between them to launch from the 2nd deck. Provide the appropriate length line to ensure the 03 life floats could be safely launched.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 27 February 2020
Resolved 20 February 2020
Resolution: Vessel provided photographs that new line of the appropriate length had been installed to ensure each life float could be launched individually.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 20 February 2020
Resolved
The floating waterlights on each of the 03 lifefloats is required to be a minimum of 18 feet n length. Length the line and ensure it is attached around the body of the buoy.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 27 February 2020
Resolved 20 February 2020
Resolution: Vessel sent satisfactory photographic evidence that the floating waterlight lines were the appropriate length.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 February 2020
Resolved
The port side engine room 40-B extinguisher was not properly charge and teh gauge was in the red. Replace, refill, or repair the extinguisher
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 27 February 2020
Resolved 20 February 2020
Resolution: Fire servicing technician arrived during the inspection and serviced extinguisher to ensure satisfactory condition.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 20 February 2020
Resolved
Program MMSI number into primary VHF radio.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2020
Resolved 20 February 2020
Resolution: Vessel provided photograph indicating that the MMSI number had been programed into the primary VHF radio installation
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 20 February 2020
Resolved
Vessel's charts were outdated and did not cover the entire operating area. Provide updated charts.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2020
Resolved 26 February 2020
Resolution: Owner provided photograph that new Oceangraffix chart, updated to this year 2020, had been received and was onboard for use.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 20 February 2020
Resolved
Vessel did not have current tables for operating area. Provided appropriate current tables.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2020
Resolved 21 February 2020
Resolution: Upon review of NOAA's website, there is no current station applicable to the vessel's operating area and thus the vesssel does not need current tables.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 20 February 2020
Resolved
Post COI in conspicuous place where passengers.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2020
Resolved 20 February 2020
Resolution: Vessel provided photograph that the COI had been posted in the main accomodation area of the vessel for review by the passengers
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 February 2020
Resolved
Lights indicating the operation of bilge pumps must be visible at the opearting station. Replace inoperable LED lights
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2020
Resolved 26 February 2020
Resolution: Owner provided photograph showing that all of the inoperable lights indicating bilge pump operation had been replaced and were properly illuminating.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 29 April 2019
Resolved
Replace fire extinguisher in accommodation space, due to low charge.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2019
Resolved 2 May 2019
Resolution: Replaced with new extinguisher.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 29 April 2019
Resolved
Secure life floats in tandem or provide individual painter lines for each life float.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2019
Resolved 2 May 2019
Resolution: Life floats properly secured.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 29 April 2019
Resolved
Repair damage to lifefloat corner. Vessel is limited to carrying 30 persons on board until deficiency is rectified.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2019
Resolved 2 May 2019
Resolution: Lifefloat repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 29 April 2019
Resolved
Repair wasted grab lines on life floats. Vessel is limited to carrying 30 persons on board until deficiency is rectified.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2019
Resolved 2 May 2019
Resolution: Grab lines replaced.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 29 April 2019
Resolved
Replace EPIRB battery. Vessel is limited to operating no more than 3 NM from shore.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2019
Resolved 3 May 2019
Resolution: New battery provided.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 29 April 2019
Resolved
Provide DOT alcohol testing devices. Vessel is limited to operating no more than 2 hours from homeport.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2019
Resolved 2 May 2019
Resolution: Alcohol test strips provided.
05 - Radio Communications › N/A - No Subsystem › Performance standards for radio equipment
Issued 29 April 2019
Resolved
Provide updated Safety Radio Telephony Certificate.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2019
Resolved 2 May 2019
Resolution: FCC safety radiotelephony certificate provided.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 29 April 2019
Resolved
Provide cap for sink drain overboard in starboard engine room .
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2019
Resolved 2 May 2019
Resolution: Cap provided.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 29 April 2019
Resolved
Provide proper gaskets for aft hatches.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2019
Resolved 2 May 2019
Resolution: Gaskets provided.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 29 April 2019
Resolved
Secure life float painter casing to the deck with appropriate sized screws.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2019
Resolved 2 May 2019
Resolution: Painter secured.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 29 April 2019
Resolved
Repair autopilot steering system leak under the bridge control panel.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2019
Resolved 2 May 2019
Resolution: Leak repaired.
Engineering › Engine Controls (Electric/Electronic) › Circuit Board
Issued 31 January 2017
Resolved
Replace gage panel housing enclosure on port main engine
Action required: 705 - Other - as specified
Due 15 February 2017
Resolved 15 February 2017
Resolution: Vessel renewed gage panel
Stability › Watertight Integrity › Weathertight Enclosure
Issued 31 January 2017
Resolved
Repair fiberglass surface under port aft scuttle.
Action required: 705 - Other - as specified
Due 15 February 2017
Resolved 15 February 2017
Resolution: Vessel repaired scuttle
Construction/Loadline › Penetrations › Gasket
Issued 9 August 2016
Resolved
no gasket material
Action required: 705 - Other - as specified
Due 9 August 2016
Resolved 9 August 2016
Resolution: Gasket material was added
Lifesaving › Lifefloat › Serviceable
Issued 8 February 2016
Resolved
Provide Serviceable Life Floats for Vessel, 45 persons.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 February 2016
Resolved 25 February 2016
Stability › Watertight Integrity › General
Issued 8 February 2016
Resolved
New gaskets on all water tight hatches.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 February 2016
Resolved 25 February 2016
Resolution: Installed.