Records from 1982 to 1995. Most recent: inspection, 21 March 1995.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 21
21 March 1995
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 960676
8 November 1993
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1452998
2 October 1992
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1451814
1 October 1992
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 956427
5 January 1992
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 945958
9 July 1991
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 935588
1 July 1991
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1245020
24 July 1990
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1228702
23 July 1990
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1220520
11 July 1990
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 988828
6 September 1989
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1194657
25 August 1989
Hull Examination · COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1036408
12 July 1988
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1208383
15 June 1988
Hull Examination · COI Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 893655
13 April 1987
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1323595
15 July 1986
Damage Survey · Examination of Repairs
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 985106
4 June 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 986932
10 May 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1292151
9 August 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1286797
18 June 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 964202
9 June 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273430
Electrical
Issued 2 October 1992
Resolved
SEVERAL ELECTRICAL JUNTION BOXES THROUGHOUT OPEN DECK AREAS HAD LOOSE WIRING PENETRATIONS AND WERE NOT WEATHER TIGHT. SOME JUNTION BOXES WERE NOTED WITHOUT THIER COVERS.
Condition: Unknown
Due 4 January 1993
Resolved 4 January 1993
Documentation
Issued 1 July 1991
Resolved
CONDUCT FIRE/BOAT DRILL
Condition: Unknown
Due 1 July 1991
Resolved 1 July 1991
Fire Fighting
Issued 11 July 1990
Resolved
PROVIDE ONBOARD A CG APPROVED FIRE AND SAFETY PLAN.
Condition: Unknown
Due 11 July 1990
Resolved 11 July 1990
Documentation
Issued 25 August 1989
Resolved
PROVIDE COPY OF G-MSC APPROVED PLANS FOR MOON POOL INSTALLATION.
Condition: Unknown
Due 25 August 1989
Resolved 25 August 1989
Unknown
Issued 25 August 1989
Resolved
CONDUCT FIRE DRILL ON BOARD VESSEL IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 25 August 1989
Resolved 25 August 1989
Unknown
Issued 25 August 1989
Resolved
CONDUCT ABANDON SHIP DRILL IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 25 August 1989
Resolved 25 August 1989
Fire Fighting
Issued 25 August 1989
Resolved
INSTALL AND PROVIDE PROOF OF INSTALLATION OF GLASS RETAINING CLIPS ON ALUMINUM FRAME WINDOWS.
Condition: Unknown
Due 25 August 1989
Resolved 25 August 1989
Unknown
Issued 15 June 1988
Resolved
MAKE OVERSPEED TRIPS ON BOTH GENERATORS OPERATIONAL. TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT OCMI PRIOR TO THE BELOW COMPLIANCE DATE.
Condition: Unknown
Due 15 June 1988
Resolved 15 June 1988
Deck/Cargo
Issued 9 August 1984
Resolved
PROVIDE DOCUMENTATION OF [name withheld] AFT AIR RECIEVER ON MAIN DECK
Condition: Unknown
Due 9 August 1984
Resolved 9 August 1984
Engineering
Issued 9 August 1984
Resolved
RELAG AS NECESSARY STEAM PIPING IN CRANCE
Condition: Unknown
Due 9 August 1984
Resolved 9 August 1984
Documentation
Issued 9 August 1984
Resolved
PROVIDE UPDATED OR NEW FIRE AND SAFETY PLAN TO SATISFACTION OF COGNIZANT OCMI
Condition: Unknown
Due 9 August 1984
Resolved 9 August 1984
Construction/Loadline
Issued 9 August 1984
Resolved
REPAIR OR REPLACE ALL HELO PAD LANDING LIGHTS OF OPERABLE CONDITION
Condition: Unknown
Due 9 August 1984
Resolved 9 August 1984
Construction/Loadline
Issued 9 August 1984
Resolved
MAKE PERMANENT REPAIRS TO HELO PAD EMERGENCY NET TO PREVENT DAMAGE TO LANDING LIGHTS WHEN NETS IN RAISED POSITION
Condition: Unknown
Due 9 August 1984
Resolved 9 August 1984
Construction/Loadline
Issued 9 August 1984
Resolved
REPLACE WATERTIGHT DOOR AND FRAME SECOND DECK IN QUARTERS FORWARD END PASS-AGEWAY.
Condition: Unknown
Due 9 August 1984
Resolved 9 August 1984
Documentation
Issued 9 August 1984
Resolved
PROVIDE PROPER STATION BILL FOR VESSEL OR UPDATE PRESENT BILL
Condition: Unknown
Due 9 August 1984
Resolved 9 August 1984
Deck/Cargo
Issued 9 August 1984
Resolved
PROVIDE DOCUMENTATION AS REQUIRED BY 46CFR 91-37 FOR TESTING OF CRANE
Condition: Unknown
Due 9 August 1984
Resolved 9 August 1984
Unknown
Issued 9 August 1984
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL W-701 DN281030
Condition: Unknown
Due 9 August 1984
Resolved 9 August 1984
Lifesaving
Issued 9 August 1984
Resolved
INSTALL EMERGENCY LIGHTS IN WAY OF BOTH LIFE RAFT EMBARKATION STATIONS
Condition: Unknown
Due 9 August 1984
Resolved 9 August 1984
Lifesaving
Issued 9 August 1984
Resolved
INSTALL SUITABLE LAUNCHING SLIDE FOR STBD AFT LIFE RAFT
Condition: Unknown
Due 9 August 1984
Resolved 9 August 1984
Electrical
Issued 9 June 1982
Resolved
PROVIDE REMOTE FUEL SHUT-OFF FOR #1 & #2 SHIP SERVICE GENERATORS AND PROVIDE METAL OR APPROVED FLEXIBLE FUEL LINES.
Condition: Unknown
Due 9 June 1982
Resolved 9 June 1982
Unknown
Issued 9 June 1982
Resolved
ATTACH A FIREHOSE WITH APPROVED COMBINATION NOZZLE AT ALL FIRE STATIONS.
Condition: Unknown
Due 9 June 1982
Resolved 9 June 1982
Engineering
Issued 9 June 1982
Resolved
OPERATIONALLY TEST AND SEAL THE AFT BOILER SAFETY VALVE.
Condition: Unknown
Due 9 June 1982
Resolved 9 June 1982
Engineering
Issued 9 June 1982
Resolved
REMOVE WATERSIDE SCALE DEPOSITS FROM THE BOILER.
Condition: Unknown
Due 9 June 1982
Resolved 9 June 1982