ROSIE

ROSIE is a 1960 passenger vessel (inspected). The Coast Guard has recorded 73 inspections since 1985, most recently in April 2026, along with 167 deficiencies.

Records from 1985 to 2026. Most recent: inspection, 16 April 2026.

Built
1960
Last inspected
16 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD5838
Flag
UNITED STATES
367164460
Maury page id
psix-43853

Inspections, by type

…with no type recorded3
Years with a record 38 calendar years (1985–2026)
The 73 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)61.6 ft × 17.5 ft × 3.7 ft
Registered tonnagegross 41 / net 28
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSTOWMAN SHIPBLDG CORP · DORCHESTER, NJ, UNITED STATES · built 1960
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMORICHES, NY
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 12 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it41 - Regulatory (Subpart C or D), Gross Ton
28 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP5845MMSI 367164460 · active · compulsorily equipped · granted 10 May 2024, expires 10 May 2034
WDJ9971MMSI 367164460 · cancelled · compulsorily equipped · granted 5 April 2018, cancelled 8 May 2024
WDD5838MMSI 367164460 · expired · voluntarily equipped · granted 2 February 2007, cancelled 8 April 2017
WCX2881MMSI not assigned · expired · compulsorily equipped · granted 28 February 1997, cancelled 5 May 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 73

16 April 2026 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8350956
21 April 2025 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8116489
28 October 2024 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8024767
29 April 2024 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7903114
27 April 2023 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7677262
13 October 2022 In-Service Inspection · Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7570458
27 April 2022 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7438291
3 August 2021 Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7288417
28 April 2021 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7153672
23 September 2020 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7063081
25 June 2020 Re-Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6974723
5 September 2019 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6719895
9 October 2018 Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6555706
23 July 2018 Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6488286
18 June 2018 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6386355
11 September 2017 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6229191
4 October 2016 Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6015392
20 September 2016 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6004857
20 January 2016 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5800204
3 October 2014 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4998115
28 September 2011 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4154603
21 April 2009 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3457209
10 February 2009 In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3416571
28 April 2008 Simplified Stability Test · Administrative Inspection · Plan Review "T" Boat
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3192326
5 March 2008 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3158610
26 September 2007 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3066390
22 March 2007 Annual Inspection · MARPOL Annex V Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2892287
18 April 2006 Re-Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2627042
15 November 2005 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2532586
17 March 2005 COI Inspection · Deficiency Check
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2312385
18 March 2004 MARPOL Annex V Examination · Annual Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2024752
30 October 2003 Internal Structural Exam · Hull Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1935433
12 March 2003 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1755754
9 April 2002 Examination of Repairs
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1604794
14 March 2002 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1493208
15 February 2002 Examination of Repairs
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1604788
10 November 2001 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1366650
14 March 2001 Re-Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1413934
15 March 2000 MARPOL Annex V Examination · COI Inspection · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1427796
9 November 1999 Deficiency Check · Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1401123
10 May 1999 Plan Review "T" Boat
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1129333
8 March 1999 Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1410048
28 April 1998 MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1411675
12 November 1997 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1472897
4 March 1997 MARPOL Annex V Examination · COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1101584
9 April 1996 MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1085789
11 March 1996 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1085788
7 April 1995 MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1239892
24 February 1995 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1234872
26 September 1994 Deficiency Check · Drydock Extension
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1179725
24 March 1994 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 859402
16 July 1993 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 832733
7 April 1993 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1140596
8 April 1992 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1255667
13 August 1991 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 943765
14 February 1991 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 910181
23 May 1990 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 928051
14 March 1990 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 903318
22 February 1990 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 902944
20 June 1989 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1200762
25 April 1989 Deficiency Check · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1041354
24 February 1989 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1031942
16 March 1988 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1336594
11 February 1988 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1329576
10 December 1987 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1336593
31 July 1986 Deficiency Check · Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1294445
19 June 1986 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 988495
24 April 1986 Credit Drydock
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1306302
11 October 1985 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1295904
10 October 1985 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1296021
18 June 1985 Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 990385
21 March 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1287798
24 January 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 976311

Deficiency record · 167

11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 16 April 2026 Resolved
Replace 6 expired hand red flares.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2026
Resolved 17 April 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 April 2025 Resolved
Replace 5 k-pok lifejackets as they are no longer serviceable.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 April 2025
Resolved 22 April 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 April 2025 Resolved
Replace 5 PFD water lights.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 April 2025
Resolved 22 April 2025
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 April 2025 Resolved
Remove twist wire nuts used in wiring of steering space bilge alarm and replace with approved connections.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2025
Resolved 22 April 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 April 2024 Resolved
Provide retro reflective tape to life ring and life floats.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2024
Resolved 30 April 2024
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 29 April 2024 Resolved
Provide 2 additional night flares.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2024
Resolved 30 April 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 April 2024 Resolved
Double clamp port MDE seawater intake.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 April 2024
Resolved 30 April 2024
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 27 April 2023 Resolved
Vessel must conduct drills to the satisfaction of attending MI. Vessel only had a rope ladder for recovering a MOB which was deemed insufficient.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2023
Resolved 25 May 2023
Resolution: Vsl has fabricated an aluminum ladder and performed drills.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 April 2023 Resolved
Vessel's lifering was beyond its serviceable life. Issued requirement to install new lifering.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2023
Resolved 1 May 2023
Resolution: New life ring installed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 27 April 2023 Resolved
Issued requirement to add retro to the 03 on board liferafts.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2023
Resolved 27 April 2023
Resolution: Completed while on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 April 2023 Resolved
Issued requirement to label child PFD location.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2023
Resolved 1 May 2023
Resolution: Labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 April 2023 Resolved
Issued requirement to label child PFDs with vessel name.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2023
Resolved 1 May 2023
Resolution: Marked.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 April 2023 Resolved
Issued requirement to install interconnected smoke alarms in spaces IAW with new regulations for Oceans route. Must be UL 217 compliant.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2023
Resolved 1 May 2023
Resolution: Installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 April 2023 Resolved
Issued requirement to provide a current consortium letter with enrolled crew.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2023
Resolved 1 May 2023
Resolution: Proved.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 April 2023 Resolved
Issued requirement to provide alcohol testing strips.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2023
Resolved 25 May 2023
Resolution: Alcohol strips on board.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 13 October 2022 Resolved
Excavate wood rot on planking inboard side of starboard exhaust where it penetrates the hull and make approved repair.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 October 2022
Resolved 27 October 2022
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 27 April 2022 Resolved
Vessel did not have current charts or pubs.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 10 June 2022
Resolution: Bought.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 27 April 2022 Resolved
First aid kit missing some items.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 10 June 2022
Resolution: Bought.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 5 September 2019 Resolved
No FCC Communications license or Communications Commision Safety Radio Telephony Certificate on board. 47 CFR 80.13 47 CFR 80.59(a)(2) 47 CFR80.901
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2019
Resolved 9 September 2019
Resolution: O/O provided copies of radio inspections completed last year by FCC qualified examiner
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 5 September 2019 Resolved
Light List and Coast Pilot not on board.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2019
Resolved 9 September 2019
Resolution: O/O sent proof of copies of the documents printed from NAVCEN and NOAA for the operating area
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 5 September 2019 Resolved
EPIRB was satisfactory (battery, hydro, & registration), however monthly test were not being logged.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2019
Resolved 9 September 2019
Resolution: O/O added a section to his log book for monthly tests and inspections where the first entry was with us on inspection.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 5 September 2019 Resolved
Drills were conducted satisfactorily; however drills were not logged IAW: 46CFR 185.420(c)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2019
Resolved 9 September 2019
Resolution: O/O created section in the vessel's log book to capture required drills, exercises, and training. First entry was our evaluation completed and a note to add tether to vessel as per emergency instructions posted.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 5 September 2019 Resolved
Drills were conducted satisfactorily; however drills were not logged IAW: 46CFR 185.420(c)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2019
Resolved 9 September 2019
Resolution: O/O added section to vessel's log book to capture required drills, exercises, and training. first entry was our evaluation of teh crew during a vessel fire drill.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 5 September 2019 Resolved
Emergency instructions state teh deckhand will have a tether on to go over the side on their MOB recovery plan. Vessel did not have a tether to adhere to emergency instructions posted.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2019
Resolved 25 June 2020
Resolution: Provide tether for MOB IAW emergency instructions posted.
Engineering › Bilge Water Management System › Pump
Issued 18 June 2018 Resolved
Replace bilge pump impellor
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 June 2018
Resolved 18 June 2018
Resolution: O/O replaced impellor
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 June 2018 Resolved
Clean up elctrical under bridge nav. station
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 June 2018
Resolved 23 July 2018
Resolution: O/O removed dead end wiring and updated, resecured loose wiring
Lifesaving › Lifefloat › Retroreflective Material
Issued 18 June 2018 Resolved
Reinstall retro on life float
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 June 2018
Resolved 23 July 2018
Resolution: O/O reinstalled retroreflective material
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 18 June 2018 Resolved
Replace failed batteries for PML's
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 June 2018
Resolved 23 July 2018
Resolution: O/O surveyed all PML's an installed working batteries as required
Documentation › Certificates/Documents › FCC SSL
Issued 11 September 2017 Resolved
Provide a current (Valid) FCC Station License. Vessel is not operating, granted extra time to meet requirement. GL
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 October 2017
Resolved 11 April 2018
Resolution: License provided
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 4 October 2016 Resolved
Repair/Replace thru hull for MSD, will not fully close.
Action required: 705 - Other - as specified
Due 4 October 2016
Resolved 7 October 2016
Resolution: Purchased and installed new thru hull valve. Operation tested satisfactory.
Engineering › Steering Gear System › Rudder Stock
Issued 4 October 2016 Resolved
Repair/tighten stbd rudder post and perform underway drills prior to credit hull. Very loose
Action required: 705 - Other - as specified
Due 4 October 2016
Resolved 12 October 2016
Resolution: Attended vessel in water and conducted underway drills. Cleared def.
Lifesaving › Hand Flares › Quantity
Issued 20 September 2016 Resolved
Provide one(01) flare to equal twelve(12)at operation station.
Action required: 705 - Other - as specified
Due 4 October 2016
Resolved 3 October 2016
Resolution: New set of (04) red hand flares added to existing (11) totalling (15).
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 20 September 2016 Resolved
Provide tide tables.
Action required: 705 - Other - as specified
Due 4 October 2016
Resolved 3 October 2016
Resolution: 2016 eldridge book bought and place on board vessel.
Navigation › Piloting/Steering › US Coast Pilot
Issued 20 September 2016 Resolved
Provide Coast Pilot for area of operation.
Action required: 705 - Other - as specified
Due 4 October 2016
Resolved 3 October 2016
Resolution: 2016 eldridge book bought and placed on board vessel.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 20 September 2016 Resolved
Provide light list for area of operation.
Action required: 705 - Other - as specified
Due 4 October 2016
Resolved 3 October 2016
Resolution: 2016 eldridge book bought and placed on board the vessel.
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 September 2016 Resolved
Replace wire nuts with permanent connectors on macerator pump.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 4 October 2016
Resolved 3 October 2016
Resolution: Wire leads going to macerator have been spliced with permanent type compression connectors.
Construction/Loadline › Hull › Strut/Cross Tie
Issued 3 October 2014 Resolved
Replace wasted Stbd Strut Block PTCHE
Action required: 705 - Other - as specified
Resolved 9 October 2014
Resolution: Stbd strut butt block replaced.
Construction/Loadline › Hull › Strut/Cross Tie
Issued 3 October 2014 Resolved
Replace Port strut block PTCHE
Action required: 705 - Other - as specified
Resolved 9 October 2014
Resolution: Strut block replaced.
Engineering › Bilge Water Management System › Valve
Issued 3 October 2014 Resolved
Repair or replace collision compartment bilge suction valve. Show proper operation of valve after repair/replacement.
Due 10 October 2014
Resolved 9 October 2014
Resolution: Valve replaced and operational test sat.
Engineering › Bilge Water Management System › Hose
Issued 3 October 2014 Resolved
Repair or replace Laz Bilge overboard thru hull spoil piece PTCHE.
Action required: 705 - Other - as specified
Resolved 9 October 2014
Resolution: Thru hull spoil piece secured.
Construction/Loadline › Structures › Superstructure
Issued 3 October 2014 Resolved
Replace cabin to deck (O2 amidships) fasteners IVA tank sewage hold tanks.
Due 9 October 2014
Resolved 9 October 2014
Resolution: Replaced
Lifesaving › Lifebuoys › Serviceable
Issued 28 September 2011 Resolved
An extra R/B aboard has a worn grab line.
Action required: 705 - Other - as specified
Due 28 September 2011
Resolved 28 September 2011
Resolution: Line renewed date of exam.
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 28 April 2008 Resolved
Complete new radio SSB installation. Obtain FCC certificate for SSB radio station.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 September 2008
Resolved 4 September 2008
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 28 April 2008 Resolved
Provide PFD lights. Demonstrate to the satisfaction of the attending inspector that the PFDs with lights will not be mistaken for those wo/ lights should they be needed during a voyage on exposed waters.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 September 2008
Resolved 4 September 2008
Stability › Incline Test › General
Issued 5 March 2008 Resolved
Vessel had been operating with passengers on the upper deck without authorization from stability test conducted in 1984. In order for vessel to carry passengers on the upper deck then a new SST must be conducted. If the owner operator choses not to do the stability test at this time, they must properly label the upper deck to specify that NO PASSENGERS ARE ALLOWED ON UPPER DECK.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 September 2008
Resolution: SST CONDUCTED
Engineering › Bilge Water Management System › Valve
Issued 26 September 2007 Resolved
Repair or replace sea valves at penetration of side shell for overboard discharges of submersible electric bilge pumps.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2007
Resolved 2 October 2007
Resolution: Two replaced and all others cleaned & freed.
Construction/Loadline › Hull › Keel
Issued 26 September 2007 Resolved
Remove worm shoe at aft end of keel (approximately between 2' & 7' from aft end) to examine possible borer damage. If damage found then propose a repair for review by CG inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 5 October 2007
Resolved 2 October 2007
Resolution: No active borers found. Minimal penetration noted. Sealed and worm shoe replaced.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 26 September 2007 Resolved
Clean debris from foward compartment IWO stem & keel. Note: trash appears to have been shoved into compartment vents as an means of disposal by passengers and this may cause dificulties in dewatering space. Additionally the dampness retained may lead to a rotting condition.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 October 2007
Resolved 2 October 2007
Resolution: Bilge spaces vacuumed clean. Plywood panel fitted as kick plate in back of step to make it more difficult to push debris into the compartment vents. It appears that the plywood was there in the past and was left off for a while.
Construction/Loadline › Hull › Bracket
Issued 26 September 2007 Resolved
Clean & chip rust from steel bresthook IWO stem at main deck level. Seal metal with rust inhibitor / paint.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2007
Resolved 2 October 2007
Resolution: Metal brest hook chipped, cleaned, and painted.
Construction/Loadline › Structures › Deck Plating
Issued 26 September 2007 Resolved
In fuel tank compt.: repair loose support block for covering board on stbd side IWO aft end of main deck freeing port.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 October 2007
Resolved 2 October 2007
Resolution: Existing loose block refastened.
Construction/Loadline › Structures › Deck Plating
Issued 26 September 2007 Resolved
In engine room; repair loose support block for covering board on stbd side IWO aft side frame.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 October 2007
Resolved 2 October 2007
Resolution: Replaced as original.
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 26 September 2007 Resolved
Repack both shaft glands.
Condition: Improper/Lack of Maintenance
Due 5 October 2007
Resolved 2 October 2007
Resolution: Completed satisfactorily.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 26 September 2007 Resolved
Repair aft bhd and associated bottom frame where water damaged / rotted wood exists from prolonged deck hatch leakage.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 October 2007
Resolved 2 October 2007
Resolution: Soft wood removed for a depth of 1/2" TO 1" Rx w/ ethylene glycol to kill any fungi dried w/ acetone and packed with epoxy filler.
Construction/Loadline › Structures › Scuttle
Issued 26 September 2007 Resolved
Free dogs on aft hatch or replace as necssary to permit proper securing of the lazarette access hatch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2007
Resolved 2 October 2007
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 26 September 2007 Resolved
Both props reconditioned during yard period.
Due 28 September 2007
Resolved 27 September 2007
Resolution: Completed. observed fit-up of props. New keys fabricated & sized to allow proper fit. Lock nuts & cotter pin installed.
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 26 September 2007 Resolved
Port & Stbd aft shaft bearings in strut R & R.
Due 28 September 2007
Resolved 27 September 2007
Resolution: New bearings pressed in.
Engineering › Sea-water System (primary cooling) › Valve
Issued 26 September 2007 Resolved
P & S MDE main raw water sea suction 2" ball valves R & R. Master stated that they were operating with too much resistance to movement and the Port MDE sea valve stem fractured when he tried to force the valve closed.
Due 28 September 2007
Resolved 27 September 2007
Resolution: New ball valves installed to replace existing valves.
Engineering › Bilge Water Management System › Manifold
Issued 22 March 2007 Resolved
Mark bilge manifold valves.
Condition: Improper/Lack of Maintenance
Due 1 April 2007
Resolved 31 March 2007
Resolution: Completed.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 22 March 2007 Resolved
Provide original of COD. (Note: COD mailed to O/O by NVDC this week.)
Condition: Damaged By Earlier Event
Due 1 April 2007
Resolved 31 March 2007
Resolution: Completed.
Lifesaving › Buoyant Apparatus › Marking
Issued 22 March 2007 Resolved
Finish marking of B/A. (Note: Two of three B/As aboard were marked after all were repainted. Wx stopped work.)
Due 1 April 2007
Resolved 31 March 2007
Resolution: Completed.
Communications › Radio Communications › EPIRB
Issued 22 March 2007 Resolved
Mark expiration date of hydrostatic release on EPIRB.
Condition: Improper/Lack of Maintenance
Due 22 March 2007
Resolved 22 March 2007
Lifesaving › Lifefloat › Painter
Issued 22 March 2007 Resolved
Replace wasted shackle to float free link and replace three pendants securing L/Fs to sea painter.
Condition: Improper Installation
Due 22 March 2007
Resolved 22 March 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 22 March 2007 Resolved
Complete replacement of decl light fwd stbd.
Condition: Improper/Lack of Maintenance
Due 1 April 2007
Resolved 31 March 2007
Resolution: Completed.
Documentation › Certificates/Documents › Stability Letter
Issued 22 March 2007 Resolved
Post stability ltr in pilothouse and provide a copy to the CG inspector.
Condition: Improper Installation
Due 1 April 2007
Resolved 31 March 2007
Resolution: Completed.
Communications › Radio Communications › EPIRB
Issued 18 April 2006 Resolved
Hydro release expired, replace prior to operation outside of 3 miles from shore.
Condition: Improper Installation
Due 28 April 2006
Resolved 6 May 2006
Resolution: Received a fax statement from master attesting to the clearance of requirements.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 18 April 2006 Resolved
Service fire extinguishers
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2006
Resolved 6 May 2006
Resolution: Received a fax statement from master attesting to the clearance of requirements.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 18 April 2006 Resolved
Provide an additional 13 L/J, maximum PAX count reduced to 69.
Condition: Placed in Improper Service
Due 28 April 2006
Resolved 6 May 2006
Resolution: Received a fax statement from master attesting to the clearance of requirements.
Lifesaving › Visual Distress Signals (General) › Expired
Issued 18 April 2006 Resolved
Provide an additional 3 smoke signalling devices
Condition: Placed in Improper Service
Due 28 April 2006
Resolved 6 May 2006
Resolution: Received a fax statement from master attesting to the clearance of requirements.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 18 April 2006 Resolved
Post COI
Condition: Improper Installation
Due 28 April 2006
Resolved 6 May 2006
Resolution: Received a fax statement from master attesting to the clearance of requirements.
Operations/Management › Passenger Operations › Safety Orientation
Issued 17 March 2005 Resolved
Conduct passenger safety orientations prior to each trip.
Due 31 March 2005
Resolved 31 March 2005
Resolution: Per conversation w/ O/O.
Communications › Radio Communications › EPIRB
Issued 17 March 2005 Resolved
Test EPIRB monthly, log results.
Due 31 March 2005
Resolved 31 March 2005
Resolution: Per conversation w/ O/O.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 17 March 2005 Resolved
Label distribution panels in pilothouse.
Due 31 March 2005
Resolved 7 April 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Lifesaving › Lifefloat › Float Free
Issued 17 March 2005 Resolved
Modify flag rigging to reduce interference with lifefloats.
Due 31 March 2005
Resolved 31 March 2005
Resolution: Per conversation w/ O/O.
Lifesaving › Lifefloat › Retroreflective Material
Issued 17 March 2005 Resolved
Paint and re-tape lifefloats.
Due 10 September 2005
Resolved 27 September 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 17 March 2005 Resolved
Label ring buoy with vessel name and hailing port.
Due 31 March 2005
Resolved 7 April 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 17 March 2005 Resolved
Re-tape 3 adult lifejackets.
Due 31 March 2005
Resolved 31 March 2005
Resolution: O/O replaced w/new jackets.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 17 March 2005 Resolved
Provide one adult lifejacket, vessel restricted to 78 passengers until completed.
Due 31 March 2005
Resolved 7 April 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Engineering › Steering Gear System › Rudder
Issued 17 March 2005 Resolved
Tighten port rudder shaft packing.
Due 31 March 2005
Resolved 7 April 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 17 March 2005 Resolved
Install capture chain on lazarette hatch cover.
Due 31 March 2005
Resolved 7 April 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Documentation › Certificates/Documents
Issued 18 March 2004 Resolved
Post satbility letter, COI, and FCC licenseand permits.
Due 1 April 2004
Resolved 9 April 2004
Operations/Management › Drills/Instruction
Issued 18 March 2004 Resolved
Conduct and log quarterly drills for man overboard, abandon shio, and fire fighting drills. LEGACY COMPONENT DESC: Man Overboard Recovery
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 March 2004
Navigation › Collision/Grounding Avoidance
Issued 18 March 2004 Resolved
Fix/replace Nav lights in accordance with COLREGS, stern, port, and stbd lights. LEGACY COMPONENT DESC: Navigation Lights
Due 1 April 2004
Resolved 9 April 2004
Lifesaving › Lifebuoys
Issued 18 March 2004 Resolved
Replace line on ring buoy. LEGACY COMPONENT DESC: Buoyant Lifeline
Due 1 April 2004
Resolved 9 April 2004
Accommodation/Occupational Safety › Medical/First Aid
Issued 18 March 2004 Resolved
Provide first aid kit with ammonia inhalents. LEGACY COMPONENT DESC: Medicine Chest
Due 1 April 2004
Resolved 9 April 2004
Engineering › Bilge Water Management System
Issued 18 March 2004 Resolved
Repair/replace main bilge system. LEGACY COMPONENT DESC: Pump
Due 1 April 2004
Resolved 9 April 2004
Resolution: Also has rule pumps that are accepted becuase of vsl size that are opperable.
Engineering › Bilge Water Management System
Issued 18 March 2004 Resolved
Replace fuel tank compartment Rule Pump discharge hose. LEGACY COMPONENT DESC: Hose
Due 1 April 2004
Resolved 9 April 2004
Communications › Radio Communications
Issued 12 March 2003 Resolved
Provide radio operator's permit. LEGACY COMPONENT DESC: VFH Radiotelephone
Due 31 March 2003
Resolved 9 April 2003
Resolution: Master took course iin 02. Has letter from FCC stating that he passed and has been issued a new permit, however, he never received permit. He is working with FCC to getcopy of permit.
Documentation › Certificates/Documents
Issued 12 March 2003 Resolved
Post COI. LEGACY COMPONENT DESC: Certificate of Inspection
Condition: Improper Installation
Due 31 March 2003
Resolved 9 April 2003
Resolution: Posted.
Documentation › Markings/Placards
Issued 12 March 2003 Resolved
Provide and post emergency broadcast placard IAW 46 CFR 184.506.
Due 31 March 2003
Resolved 9 April 2003
Resolution: Posted.
Engineering › Bilge Water Management System
Issued 12 March 2003 Resolved
Label crash compartment on alarm panel.
Due 31 March 2003
Resolved 9 April 2003
Resolution: Labeled.
Lifesaving › Lifebuoys
Issued 12 March 2003 Resolved
Renew battery in waterlight. LEGACY COMPONENT DESC: Self-igniting Lights
Due 31 March 2003
Resolved 9 April 2003
Resolution: New battery purchased and installed.
Lifesaving › Lifejacket/PFD (Type I)
Issued 12 March 2003 Resolved
Renew 5 adult and 1 child PFD. Vessel restricted to carrying no more than 73 adults and 6 children (w/in 3 miles) until corrected. LEGACY COMPONENT DESC: Condition
Due 31 March 2003
Resolved 9 April 2003
Resolution: New jackets purchased and placed on board.
Lifesaving › Lifejacket/PFD (Type I)
Issued 12 March 2003 Resolved
renew retroreflective tape on 2 child and one adult PFD. LEGACY COMPONENT DESC: Retroreflective Material
Due 31 March 2003
Resolved 9 April 2003
Resolution: New jackets purchased and placed on board.
Accommodation/Occupational Safety › Medical/First Aid
Issued 12 March 2003 Resolved
Provide aspirin and eyewash for first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Due 31 March 2003
Resolved 9 April 2003
Resolution: Purchased and placed on vessel.
Operations/Management › Drills/Instruction
Issued 12 March 2003 Resolved
Conduct and log man overboard/fire drills and training IAW 46 CFR 185.520 & 185.524. LEGACY COMPONENT DESC: Man Overboard Recovery
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2003
Resolved 9 April 2003
Resolution: Training and underway drills held and logged.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 12 March 2003 Resolved
Mount fixed fire fighting instruction placard at operating station.
Due 31 March 2003
Resolved 9 April 2003
Resolution: Mounted.
Communications › Radio Communications
Issued 12 March 2003 Resolved
Renew radio safety telephony certificate by expiration date 31 Mar 03. LEGACY COMPONENT DESC: VFH Radiotelephone
Due 31 March 2003
Resolved 9 April 2003
Resolution: Had inspection on 19 Mar. 03.
Documentation
Issued 14 March 2001 Resolved
PROVIDE WASTE MANAGEMENT PLAN, GARBAGE PLACARD.
Condition: Unknown
Due 15 May 2001
Resolved 15 May 2001
Navigation
Issued 14 March 2001 Resolved
HYDRAULIC LINES LEAKING. REPAIR/RENEW HYDRAULIC LINE TO STEERING RAM.
Condition: Unknown
Due 15 May 2001
Resolved 15 May 2001
Documentation
Issued 14 March 2001 Resolved
PROVIDE MEANS FOR VERIFICATION OF VESSEL PASSENGER ON BOARD WHILE UNDERWAY.
Condition: Unknown
Due 15 May 2001
Resolved 15 May 2001
Documentation
Issued 14 March 2001 Resolved
POST STABILITY LETTER.
Condition: Unknown
Due 15 May 2001
Resolved 15 May 2001
Lifesaving
Issued 15 March 2000 Resolved
REPLACE HYDROSTATIC RELEASE FOR EPIRB. MUST BE CORRECTED PRIOR TO SAILING OUTSIDE THE MORICHES BAY AREA.
Condition: Unknown
Due 10 April 2000
Resolved 10 April 2000
Construction/Loadline
Issued 15 March 2000 Resolved
REBOLT THE SECURING CHAIN TO THE HATCH ON DECK IWO THE COMPT. AFT OF THE ENGINE SPACE.
Condition: Unknown
Due 10 April 2000
Resolved 10 April 2000
Lifesaving
Issued 15 March 2000 Resolved
PROVIDE ADDITIONAL LIFE FLOATS SO TO HAVE PRIMARY LIFESAVING FOR 82 PERSONS.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Engineering
Issued 15 March 2000 Resolved
PORT ENGINE IS MOVING FWD & AFT SLIGHTLY ON THE BED. RESECURE.
Condition: Unknown
Due 10 April 2000
Resolved 10 April 2000
Electrical
Issued 15 March 2000 Resolved
LABLE ALL ELECTRIC SWITHCHES.
Condition: Unknown
Due 10 April 2000
Resolved 10 April 2000
Electrical
Issued 15 March 2000 Resolved
INSTALL COVER PLATES OVER ALL RECEPTICLES & SWITCHES.
Condition: Unknown
Due 10 April 2000
Resolved 10 April 2000
Lifesaving
Issued 15 March 2000 Resolved
PROVIDE A 100' SEAPAINTER W/ FLOATFREE LINK FOR LIFE FLOATS.
Condition: Unknown
Due 16 March 2000
Resolved 16 March 2000
Lifesaving
Issued 15 March 2000 Resolved
PROVIDE ONE ADULT PFD TYPE I W/ REFLECTIVE TAPE.
Condition: Unknown
Due 16 March 2000
Resolved 16 March 2000
Construction/Loadline
Issued 15 March 2000 Resolved
REPAIR BILGE ALARM.
Condition: Unknown
Due 16 March 2000
Resolved 16 March 2000
Engineering
Issued 15 March 2000 Resolved
RENEW EMERGENCY FUEL SHUT-OFF SIGN.
Condition: Unknown
Due 10 April 2000
Resolved 10 April 2000
Fire Fighting
Issued 15 March 2000 Resolved
MOUNT INSTRUCTION & WARNING SIGNS FOR FIXED FIRE EXTINGUISHER.
Condition: Unknown
Due 10 April 2000
Resolved 10 April 2000
Lifesaving
Issued 15 March 2000 Resolved
PROVIDE A CREW TRAINING INSTRUCTION FOR THE FIXED FIRE EXT. SYSTEM.
Condition: Unknown
Due 10 April 2000
Resolved 10 April 2000
Electrical
Issued 9 November 1999 Resolved
REMOVE ALL DEAD ENDED WIRING IN E/R.
Condition: Unknown
Due 30 November 1999
Resolved 7 December 1999
Engineering
Issued 9 November 1999 Resolved
FREE UP COVERS OVER FUEL SHUT OFFS IN #4 COMPT.
Condition: Unknown
Due 30 November 1999
Resolved 9 November 1999
Construction/Loadline
Issued 9 November 1999 Resolved
SCRAPE OUT ALL ANGEL HAIR IN E/R.
Condition: Unknown
Due 30 November 1999
Resolved 9 November 1999
Construction/Loadline
Issued 9 November 1999 Resolved
SECURE REACH ROD TO HANDLE ON VALVE SERVING BILGE SUCTION IN CRASH COMPT.
Condition: Unknown
Due 30 November 1999
Resolved 9 November 1999
Construction/Loadline
Issued 9 November 1999 Resolved
MAKE STEM AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 30 November 1999
Resolved 9 November 1999
Construction/Loadline
Issued 9 November 1999 Resolved
CROP AND RENEW ROTTED SECTION OF FWD BHD IN MSD SPACE WHERE BILGE PIPING PENETRATES BHD.
Condition: Unknown
Due 30 November 1999
Resolved 9 November 1999
Construction/Loadline
Issued 9 November 1999 Resolved
SCRAPE OUT DEBRIS IN MSD SPACE IWO ALL KNEES TO FACILITATE INSPECTION.
Condition: Unknown
Due 30 November 1999
Resolved 9 November 1999
Construction/Loadline
Issued 9 November 1999 Resolved
CROP AND RENEW OR SISTER ROTTED FLOOR BEAMS IN E/R.
Condition: Unknown
Due 30 November 1999
Resolved 7 December 1999
Construction/Loadline
Issued 9 November 1999 Resolved
SCRAPE OUT ALL ANGEL HAIR IN #4 COMPT TO FACILITATE INSPECTION.
Condition: Unknown
Due 30 November 1999
Resolved 9 November 1999
Fire Fighting
Issued 10 May 1999 Resolved
CONDUCT INSTALLATION TESTS AND INSPECTION OF FIXED CO2 SYSTEM/PIPING
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Lifesaving
Issued 4 March 1997 Resolved
RESOLVE TEST / RECORDS REQUIREMENTS FOR DRUG AWARENESS & SCREENING PROGRAM W/ REGARDS TO NEW OPERATOR.
Condition: Unknown
Due 5 May 1997
Resolved 5 May 1997
Engineering
Issued 4 March 1997 Resolved
AT NEXT DRYDOCK RENEW PORT ENGINE EXHAUST PIPE IN # 5 COMPT. (CURRENT PIPEIS ASBESTOS CEMENT.)
Condition: Unknown
Due 4 March 1997
Resolved 4 March 1997
Lifesaving
Issued 4 March 1997 Resolved
PROVIDE A CATAGORY 1 406 MHz EPIRB. VESSEL'S ROUTE RESTRICTED TO NOT MORE THAN 3 MILES FROM SHORE ON LAKES BAYS AND SOUNDS.
Condition: Unknown
Due 5 May 1997
Resolved 5 May 1997
Fire Fighting
Issued 4 March 1997 Resolved
PROVIDE A SECOND FIRE PUMP OR 3 FIRE BUCKETS. SEE 46CFR181.300(a)(ii) OR 46CFR181.610 TO REPLACE THE HAND DRIVEN PUMP GRANDFATHERED IN OLD REGULATIONS.
Condition: Unknown
Due 5 May 1997
Resolved 5 May 1997
Construction/Loadline
Issued 4 March 1997 Resolved
AT NEXT DRYDOCK EXAM REMOVE EPOXY COVERING FROM REPAIR TO PORT SHAFT TUBE TO PERMIT FURTHER EXAM.
Condition: Unknown
Due 5 May 1997
Resolved 5 May 1997
Construction/Loadline
Issued 4 March 1997 Resolved
REPAIR REACH ROD & VALVE IN FOREPEAK.
Condition: Unknown
Due 5 May 1997
Resolved 5 May 1997
Accommodation/Occupational Safety
Issued 4 March 1997 Resolved
DEMONSTRATE OPERATION OF MSD BY NEW OWNER.
Condition: Unknown
Due 5 May 1997
Resolved 5 May 1997
Construction/Loadline
Issued 4 March 1997 Resolved
DEMONSTRATE OPERATION OF BILGE ALARMS.
Condition: Unknown
Due 5 May 1997
Resolved 5 May 1997
Documentation
Issued 4 March 1997 Resolved
REMARK NAME ON VESSEL'S STERN.
Condition: Unknown
Due 5 May 1997
Resolved 5 May 1997
Lifesaving
Issued 4 March 1997 Resolved
MARK "DISTRESS SIGNALS" ON BOX FOR FLARES W/ 1/2" BLOCK LETTERS. SEE 46CFR185.614.
Condition: Unknown
Due 5 May 1997
Resolved 5 May 1997
Construction/Loadline
Issued 24 March 1994 Resolved
COMPLETED AN UNDERWAY EXAM IN THE ATLANTIC OCEAN. THE VESSEL IS NOT TO OPERATE OUTSIDE OF MORICHES BAY, NY UNTIL THIS REQ'T IS SATISFIED.
Condition: Unknown
Due 24 March 1994
Resolved 24 March 1994
Engineering
Issued 22 February 1990 Resolved
MAKE STARBOARD FUEL OIL CUTOFF VALVE ACCESSIBLE FROM HAND HOLE.
Condition: Unknown
Due 22 February 1990
Resolved 22 February 1990
Navigation
Issued 22 February 1990 Resolved
REPAIR ANCHOR LIGHT PRIOR TO SAILING AT NIGHT.
Condition: Unknown
Due 22 February 1990
Resolved 22 February 1990
Engineering
Issued 22 February 1990 Resolved
REPAIR BILGE SYSTEM OVERBOARD VALVE IN ENGINE ROOM.
Condition: Unknown
Due 22 February 1990
Resolved 22 February 1990
Construction/Loadline
Issued 22 February 1990 Resolved
CAULK SEAMS IN #2 COMPARTMENT AS FOLLOWS PRIOR TO CARRYING PASSENGERS: PORTSIDE AT CHINE FRAME SPACE 4 FROM AFT AND STARBOARD SIDE FRAME SPACES 1, 5 & 6 FROM AFT.
Condition: Unknown
Due 22 February 1990
Resolved 22 February 1990
Lifesaving
Issued 22 February 1990 Resolved
LABEL LIFEFLOAT PADDLES, RING BUOY AND TOP LIFEFLOAT WITH VESSEL'S NAME.
Condition: Unknown
Due 22 February 1990
Resolved 22 February 1990
Lifesaving
Issued 22 February 1990 Resolved
PROIVDE ONE ADDITIONAL LIFEFLOAT PADDLE.
Condition: Unknown
Due 22 February 1990
Resolved 22 February 1990
Engineering
Issued 22 February 1990 Resolved
INSTALL 30X30 MESH FLAME SCREENS IN FUEL OIL TANK VENTS.
Condition: Unknown
Due 22 February 1990
Resolved 22 February 1990
Construction/Loadline
Issued 25 April 1989 Resolved
REPLACE DETERIORATED KNEES AT CHINE, IN #2 COMPARTMENT, STARBOARD SIDE, AS NEEDED.
Condition: Unknown
Due 25 April 1989
Resolved 25 April 1989
Construction/Loadline
Issued 25 April 1989 Resolved
REPLACE WORM SHOE ENTIRELY FROM MIDSHIPS FORWARD.
Condition: Unknown
Due 25 April 1989
Resolved 25 April 1989
Construction/Loadline
Issued 25 April 1989 Resolved
SEAL WOOD AROUND UNUSED METAL TRANSDUCER, WHERE WASTED.
Condition: Unknown
Due 25 April 1989
Resolved 25 April 1989
Construction/Loadline
Issued 25 April 1989 Resolved
CROP TO GOOD WOOD AND REPAIR PORT BOW AT STEM, WHERE WORM DAMAGED.
Condition: Unknown
Due 25 April 1989
Resolved 25 April 1989
Navigation
Issued 25 April 1989 Resolved
REPLACE RUDDER POSTS.
Condition: Unknown
Due 25 April 1989
Resolved 25 April 1989
Construction/Loadline
Issued 25 April 1989 Resolved
REPLACE CAVITATION PLATE ABOVE PORT PROPELLER.
Condition: Unknown
Due 25 April 1989
Resolved 25 April 1989
Construction/Loadline
Issued 25 April 1989 Resolved
RECAULK AS NECESSARY.
Condition: Unknown
Due 25 April 1989
Resolved 25 April 1989
Lifesaving
Issued 11 February 1988 Resolved
MARK THE VESSEL'S LIFERING WITH THE VESSEL'S NAME.
Condition: Unknown
Due 11 February 1988
Resolved 11 February 1988
Construction/Loadline
Issued 11 February 1988 Resolved
PROVIDE A RAIL FOR THE AFTER RAIL OPENING.
Condition: Unknown
Due 11 February 1988
Resolved 11 February 1988
Accommodation/Occupational Safety
Issued 11 February 1988 Resolved
PROVIDE RUNNING WATER TO MALE/FEMALE HEAD(S).
Condition: Unknown
Due 11 February 1988
Resolved 11 February 1988
Electrical
Issued 11 February 1988 Resolved
LABEL THE ELECTRIC PANEL BOARD ON THE FOREWARD BULKHEAD OF THE PILOT HOUSE.
Condition: Unknown
Due 11 February 1988
Resolved 11 February 1988
Navigation
Issued 11 February 1988 Resolved
PROVIDE STERN LIGHT WITH 2 MILE VISIBILITY AS PER NAVIGATION RULES/COLREGS.
Condition: Unknown
Due 11 February 1988
Resolved 11 February 1988
Documentation
Issued 11 February 1988 Resolved
PROVIDE FOR REVIEW A VALID F.C.C. STATION LICENSE.
Condition: Unknown
Due 11 February 1988
Resolved 11 February 1988
Deck/Cargo
Issued 11 February 1988 Resolved
PROVIDE FOR INSPECTION AN OPERATIONAL TEST OF BILGE SUCTION IN FOREPEAK.
Condition: Unknown
Due 11 February 1988
Resolved 11 February 1988
Navigation
Issued 31 July 1986 Resolved
PROVIDE ON BOARD THE CURRENT EDITION OF CHARTS FROM LITTLE EGG, NJ TO CAPE MAY, NJ. ORIGINAL DUE DATE WAS 11JUL86.
Condition: Unknown
Due 31 July 1986
Resolved 31 July 1986
Construction/Loadline
Issued 31 July 1986 Resolved
RECAP OLD THROUGH HULL FITTING ON STBD SIDE OUTBOARD OF ENGINE. ORIGINAL DUE DATE WAS 26AUG86.
Condition: Unknown
Due 31 July 1986
Resolved 31 July 1986
Engineering
Issued 31 July 1986 Resolved
MAKE PROPER GROUND TO FUEL TANKS. ORIGINAL DUE DATE WAS 26AUG86.
Condition: Unknown
Due 31 July 1986
Resolved 31 July 1986
Engineering
Issued 31 July 1986 Resolved
INSULATE HOT SECTION OF EXHAUST PIPING ON THE PORT AND STBD ENGINE BETWEEN THE POINT OF WATER INJECTION AND THE EXHAUST MANIFOLD. ORIGINAL DUE DATE WAS 30APR86.
Condition: Unknown
Due 31 July 1986
Resolved 31 July 1986
Navigation
Issued 31 July 1986 Resolved
PROVIDE ON BOARD THE CURRENT EDITION OF COAST PILOT AND RULES OF THE ROAD. ORIGINAL DUE DATE WAS 11JUL86.
Condition: Unknown
Due 31 July 1986
Resolved 31 July 1986
Accommodation/Occupational Safety
Issued 11 October 1985 Resolved
PROVIDE WATER TO BOTH SINKS.
Condition: Unknown
Due 11 October 1985
Resolved 11 October 1985
Lifesaving
Issued 11 October 1985 Resolved
PROVIDE SPACERS BETWEEN LIFE FLOATS.
Condition: Unknown
Due 11 October 1985
Resolved 11 October 1985
Lifesaving
Issued 11 October 1985 Resolved
ATTACH PADDLES TO LIFE FLOATS.
Condition: Unknown
Due 11 October 1985
Resolved 11 October 1985
Accommodation/Occupational Safety
Issued 10 October 1985 Resolved
REPAIR LEAKS IN SEWAGE SYSTEM.
Condition: Unknown
Due 10 October 1985
Resolved 10 October 1985
Construction/Loadline
Issued 10 October 1985 Resolved
MAKE REPAIRS TO LEAKS IN CHINE IN FUEL AND ENGINE COMPARTMENTS.
Condition: Unknown
Due 10 October 1985
Resolved 10 October 1985
Lifesaving
Issued 18 June 1985 Resolved
PROVIDE LIFEJACKETS FOR 103 PERSONS. UNTIL THIS REQUIREMENT IS MET, THE VESSEL IS LIMITED TO THE CARRIAGE OF 60 PERSONS TOTAL.
Condition: Unknown
Due 18 June 1985
Resolved 18 June 1985
Lifesaving
Issued 18 June 1985 Resolved
CONNECT WATER LIGHTS TO LIFEFLOATS WITH 18 FOOT LINE IAW 46 CFR 180.15(D)(II), PRIOR TO NIGHTTIME CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 18 June 1985
Resolved 18 June 1985

Ownership record