MAURY USCG vessel records
← All vessels

CAPT. MIKE

CAPT. MIKE is a 1960 passenger vessel (inspected). The Coast Guard has recorded 10 inspections since 2016, most recently in May 2019, along with 36 deficiencies — 2 with no resolution recorded — and 1 casualty investigation in 2009.

Records from 2009 to 2019. Most recent: inspection, 22 May 2019.

Built
1960
Last inspected
22 May 2019
Documentation
Expired · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDF8391
Flag
UNITED STATES
Maury page id
psix-43854

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 4 calendar years (2016–2019)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)61.6 ft × 17.5 ft × 3.7 ft
Registered tonnagegross 41 / net 28
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSTOWMAN SHIPBUILDING CORP · DORCHESTER, NJ, UNITED STATES · built 1960
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHOWARD BEACH, NY
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it41 - Regulatory (Subpart C or D), Gross Ton
28 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 10

22 May 2019 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6689955
29 April 2019 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6672813
25 June 2018 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6454999
6 April 2018 Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6386550
24 January 2018 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6353767
15 August 2017 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6241600
27 April 2017 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6169329
28 March 2017 Drydock Extension
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6113055
16 May 2016 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5878361
31 March 2016 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5844225

Deficiency record · 36

Fire Fighting › Fixed Gas Fire Extinguishing System › Control Valve
Issued 25 June 2018 Resolved
Upon conducting a test of the vessels pre-engineered fire extinguishing system, the engines did not shut down as per 46 CFR 181.420(a)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2018
Resolution: Vessel proved proper operation of fixed fire extinguishing system.
Engineering › Bilge Water Management System › Not Operational
Issued 25 June 2018 Resolved
During an opertional test of vessels bilge pump, a fitting in the piping system burst, rendering the bilge pump inoperable. 46 CFR 182.500(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2018
Resolution: vessel proved proper operation of fixed bilge system.
Communications › Public Address System › Amplifier
Issued 25 June 2018 Resolved
PA system was inoperable. 46 CFR 184.610
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2018
Resolution: vessel proved proper operation of PA system.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 25 June 2018 Resolved
Vessel was unable to provide EAP display requirements along with any kind of required training. 46 CFR 16
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2018
Resolution: vessel provided all required documentation.
Lifesaving › Lifefloat › Serviceable
Issued 25 June 2018 Resolved
15 person lifefloat needs to be repaired with a manufacturer approved repair kit. 46 CFR 180.730
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2018
Resolved 7 September 2018
Resolution: Vessel submitted pictures of repaired life float.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 25 June 2018 Resolved
15 person lifefloat waterlight was inoperable. 46 CFR 180.175(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2018
Resolved 9 July 2018
Lifesaving › Lifefloat › Painter
Issued 25 June 2018 Resolved
Painter needs to be replaced due to deterioation and also needs to be stowed in a way to release freely. 46 CFR 180.175(f)(3)(iii,iv)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2018
Resolved 9 July 2018
Navigation › Piloting/Steering › Marine Charts
Issued 25 June 2018 Resolved
vessel must maintain up-to-date charts and publications. Vessel did not have updated charts, coast pilot, or light list. 46 CFR 184.420
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2018
Resolution: vessel provided updated chart and publications
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 25 June 2018 Resolved
All moving parts exposed to crew that pose a safety hazard must be protected with a guard. The fly wheels on port and starboard engines need guards. 46 CFR 182.177.960
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2018
Resolved 9 July 2018
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 June 2018 No resolution recorded
All solid core wires nust be replaced with stranded core wire. 46 CFR 183.05-45(b). Prior to credit Drydock.
Action required: 705 - Other - as specified
Electrical › Lighting (service) › Lighting Fixture
Issued 25 June 2018 Resolved
Outlets exposed to weather must be watertight. Several outlets throughtout the decks are not watertight. Also lighting fixture on stern needs to be repaired. 46 CFR 183.01-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2018
Resolved 9 July 2018
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 June 2018 Resolved
Stern light needs to be repaired. Stern light enclosure is not secured to the vessel. 46 CFR 183.01-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2018
Resolved 9 July 2018
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 25 June 2018 Resolved
All flammable items located in 2nd deck locker and locker located in the accommadation space (i.e. paint cans, mineral spirits, and propane tank) must be removed from vessel unless protected by a suppression system. 46 CFR 181.400
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2018
Resolution: Vessel removed all flammable materials.
Construction/Loadline › Hull › Bottom Plating
Issued 6 April 2018 No resolution recorded
Provide written repair proposal for completion of all items listed above during 2018 dry dock period.
Action required: 705 - Other - as specified
Navigation › Piloting/Steering › Marine Charts
Issued 15 August 2017 Resolved
Provide up to date charts.
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 August 2017
Resolved 29 August 2017
Resolution: Updated charts are onboard the vessel.
Navigation › Piloting/Steering › US Coast Pilot
Issued 15 August 2017 Resolved
Provide up to date Coast Pilot.
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 August 2017
Resolved 29 August 2017
Resolution: Updated Coast Pilot is onboard.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 15 August 2017 Resolved
Provide up to date Navigation Rules and Regulations.
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 August 2017
Resolved 29 August 2017
Resolution: Updated publication is onboard.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 August 2017 Resolved
Provide first-aid kit approved under 46 CFR 160.041
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 August 2017
Resolved 29 August 2017
Resolution: Approved first aid kit is onboard.
Electrical › Electric Supply System (service) › Battery Installation
Issued 15 August 2017 Resolved
Secure battery box for generator starting.
Action required: 705 - Other - as specified
Due 29 August 2017
Resolved 29 August 2017
Resolution: Complete
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 15 August 2017 Resolved
Double clamp non-metallic hose on main engine exhaust line in starboard side of generator space.
Action required: 705 - Other - as specified
Due 29 August 2017
Resolved 29 August 2017
Resolution: Complete
Engineering › Sea-water System (primary cooling) › Piping
Issued 15 August 2017 Resolved
Provide hose for generator raw water suction approved under SAE J-1942.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 August 2017
Resolved 29 August 2017
Resolution: Complete.
Construction/Loadline › Hull › Transverse Frame
Issued 27 April 2017 Resolved
Replace deck beam 2nd from fwd bulkhead in generator space
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2018
Resolved 6 April 2018
Resolution: Deck beam replaced.
Construction/Loadline › Hull › Transverse Frame
Issued 27 April 2017 Resolved
Replace 2,3,4 & 5 deck beam in tank room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2018
Resolved 6 April 2018
Resolution: Deck beams replaced.
Construction/Loadline › Hull › Transverse Frame
Issued 27 April 2017 Resolved
Replace 1st deck beam from aft bulkhead stbd side in tank room
Action required: 705 - Other - as specified
Due 31 March 2018
Resolved 6 April 2018
Resolution: Deck Beams replaced.
Construction/Loadline › Hull › Side Shell
Issued 20 May 2016 Resolved
The epoxy and 5200 needs to be removed and area taken to good wood IWO all interior seams and made ready for inspection. To be completed at Dry Dock Scheduled for 31MAR2017.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 27 April 2017
Resolution: The owner/operator request specific areas be called out for further inspection. Specific areas were called out this dry dock.
Construction/Loadline › Hull › Transverse Frame
Issued 20 May 2016 Resolved
Remove all paint, epoxy and 5200 from all deck beams, side frames, bottom frames, knees, gussets and floors within 12" of all fastening points. To be completed at Dry Dock scheduled for 31MAR2017.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 27 April 2017
Resolution: The owner/operator request specific areas be called out for further inspection. Specific areas were called out this dry dock.
Construction/Loadline › Hull › Side Shell
Issued 20 May 2016 Resolved
Remove epoxy and 5200 from the exterior chine seams. To be completed at Dry Dock scheduled for 31MAR2017.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 27 April 2017
Resolution: The owner/operator request specific areas be called out for further inspection. Specific areas were called out this dry dock.
Construction/Loadline › Hull › Side Shell
Issued 20 May 2016 Resolved
Vessel required to schedule a mid season underway operational test and internal Structural examination to be conducted between 15AUG2016 and 31AUG2016.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2016
Resolved 31 August 2016
Resolution: Complete
Operations/Management › Vessel Activity › Underway
Issued 20 May 2016 Resolved
Vessels route is restricted to Lakes, Bays and Sounds NOT MORE THAN 1000 FEET FROM SHORE until vessel completes Dry Dock Scheduled for 31MAR2017.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 27 April 2017
Resolution: Complete
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 May 2016 Resolved
Starboard running light is not functioning. Starboard running light required as per NAV Rules.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2016
Resolved 20 May 2016
Communications › Radio Communications › VHF Radiotelephone
Issued 18 May 2016 Resolved
VHF radio required to be DSC capable. Current radio setup does not have MMSI programmed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 June 2016
Resolved 20 May 2016
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 18 May 2016 Resolved
STBD engine has exhaust/salt water leak at exhaust cooler. Exhaust is to be free of leaks.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2016
Resolved 27 April 2017
Resolution: The exhaust was repaired.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 18 May 2016 Resolved
Exhaust piping needs to be double clamped when non metallic hose is utilized.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 June 2016
Resolved 27 April 2017
Resolution: Repairs were made.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 18 May 2016 Resolved
Pre engineered fixed gas fire fighting system is required to shutdown engines. Currently does not shutdown engines.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2016
Resolved 20 May 2016
Communications › Alarms/Indicators › High Water Alarm
Issued 18 May 2016 Resolved
Bilge level alarms are currently mounted too high. Vessel needs to relocate bilge level alarms lower in the bilge area.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2016
Resolved 20 May 2016
Construction/Loadline › Hull › Hull Plating
Issued 16 May 2016 Resolved
Vessel has planks pulling away from frames. Broken fasteners, missing fasteners (butt blocks, floor to frame) Deck Beam in #2 Compartment has wasted area approximately 10" X 2". Signs of several butt blocks leaking, temp repairs made with what appears to be 5200. Several seams are weaping. Make repair proposal.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2016
Resolution: Deficiency was rescended.

Casualty record · 1

31 May 2009Routine · role: Involved in a Marine Casualty · activity 3493490
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.