Inspection history · 59
1 June 2026
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8387218
18 June 2025
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8158491
11 June 2025
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8153490
6 June 2024
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7928797
7 June 2023
Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7706654
10 May 2023
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7684599
14 October 2022
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7577341
20 April 2022
DAPI Audit · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7425079
24 June 2021
Administrative Inspection · Drydock Exam · In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7234364
26 May 2021
Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7206408
19 May 2020
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6955391
5 June 2019
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6703589
22 May 2019
Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6689411
15 May 2018
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6414226
9 August 2017
Administrative Inspection · Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6227350
26 April 2017
COI Inspection · Deficiency Check · DAPI Audit · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6121923
16 September 2016
Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6002154
27 July 2016
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5940196
11 August 2015
Internal Structural Exam · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5184168
16 July 2015
DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5128799
13 August 2014
DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4944992
20 August 2013
Internal Structural Exam · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4686653
13 August 2013
DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4676790
16 May 2012
COI Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4312334
7 December 2011
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4203795
17 August 2011
Hull Examination · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4112456
28 June 2011
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4035864
23 June 2010
Annual Inspection · DAPI Audit · Administrative Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3763189
18 August 2009
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3543654
22 July 2009
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3507696
6 August 2008
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3260183
14 August 2007
Deficiency Check · Administrative Inspection · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3023546
18 May 2007
Administrative Inspection · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2933232
26 July 2006
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2724755
4 October 2005
Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2514602
8 September 2005
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2486897
20 July 2005
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2432318
11 August 2004
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2162763
8 April 2004
Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2040015
26 March 2004
Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2031666
11 September 2003
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1900196
4 June 2003
Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1809614
22 May 2003
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1798751
20 May 2002
COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1618670
17 October 2001
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1376772
4 June 2001
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1382265
6 June 2000
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1437751
21 October 1999
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1424845
27 May 1999
Deficiency Check · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1411916
29 September 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 717842
15 July 1998
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1447886
27 March 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 213040
27 March 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 213814
27 March 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 215212
17 September 1997
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1371999
18 August 1997
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1372000
18 June 1996
Initial Certification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1419692
15 March 1996
Deadweight Survey · Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1081582
15 March 1996
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1085673
Construction/Loadline › Hull › Hull Plating
Issued 9 August 2017
Resolved
Provide hull thickness readings of deck and bottom plate in 6'X10' grids, width and length of barge.
Action required: 705 - Other - as specified
Resolved 11 August 2017
Resolution: Received emailed copy of thickness measurements (uploaded to this activity).
Construction/Loadline › Structures › Deck Plating
Issued 9 August 2017
Resolved
Crop/renew cracked angle on vehicle ramp.
Action required: 705 - Other - as specified
Resolved 6 October 2017
Resolution: Conducted repair check. Examined welds on, 1 - 3', 4x4x4" angle, underside of vehicle ramp, centerline to starboard side.
Construction/Loadline › Hull › Bottom Plating
Issued 9 August 2017
Resolved
Provide addtional hull thickness readings of bottom plate in way of all hatch openings.
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 10 August 2017
Resolution: Received emailed copy of thickness measurements (uploaded to this activity).
Construction/Loadline › Hull › Hull Plating
Issued 9 August 2017
Resolved
Provide hull thickness readings of forward rake across all frames.
Action required: 705 - Other - as specified
Resolved 11 August 2017
Resolution: Received emailed copy of thickness measurements (uploaded to this activity).
Construction/Loadline › Hull › Weld
Issued 9 August 2017
Resolved
Repair cracked welds on underdeck longitudinal in #2 void.
Action required: 705 - Other - as specified
Resolved 6 October 2017
Resolution: Conducted repair check. Examined pick up welds in #2 void.
Construction/Loadline › Hull › Weld
Issued 9 August 2017
Resolved
Repair cracked welds on underdeck longitudinal in #3 void.
Action required: 705 - Other - as specified
Resolved 6 October 2017
Resolution: Conducted repair check. Examined pick up welds in #3 void.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 9 August 2017
Resolved
Repair/replace two fence corner posts in way of vehicle ramp.
Action required: 705 - Other - as specified
Resolved 6 October 2017
Resolution: Conducted repair check. Examined welds on, 2- galvanized metal fence posts at bow.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 26 April 2017
Resolved
Re label vessel name on all three life rings. (46CFR185.604)
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 1 May 2017
Resolution: Re labeled vessel name in legible letters.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 26 April 2017
Resolved
separate adult/child life jacket stowage (46CFR180.78(a)(5)
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 1 May 2017
Resolution: Purchased bags to separate stowage of lifejackets.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 11 August 2015
Resolved
Repair stitch welds in areas identified on overhead deck frame longs in voids 1, 2, 3, and 4. 46 CFR 176.610
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 13 October 2015
Resolution: Repaired all identified stitch welds on overhead deck frame longitudinal'sin voids 1,2,3, & 4.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 11 August 2015
Resolved
Replace two identified overhead deck frame longs in void 1 and lift deck. 46 CFR 176.610
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 October 2015
Resolved 13 October 2015
Resolution: Replaced the two identified longitudinal frames identified. Deck was lifted at identified areas that were sagging due to vehicle traffic.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 11 August 2015
Resolved
Replace two identified overhead deck frame longs in void 2 and lift deck. 46 CFR 176.610
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 October 2015
Resolved 13 October 2015
Resolution: Both longitudinal frames identified in void #2 were replaced with new and additional angle brackets were added for stiffening. Deck was lifted identified in places that were sagging.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 11 August 2015
Resolved
Replace three identified overhead deck frame longs in void 3 and lift deck. 46 CFR 176.610
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 October 2015
Resolved 13 October 2015
Resolution: Replaced 3 longitudinal's in the overhead that were identified during inspection. Longitudinal's had additional brackets added for stiffening. Deck was lifted at areas were sagging had occured due to vehicle traffic.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 11 August 2015
Resolved
Replace two identified overhead deck frame longs in void 4 and lift deck. 46 CFR 176.610
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 October 2015
Resolved 13 October 2015
Resolution: Replaced two overhead longitudinal's in void #4 and additional angle brackets were added for stiffening and deck areas raised were sagging had occured due to vehicle traffic.
Construction/Loadline › Structures › Superstructure
Issued 11 August 2015
Resolved
Take apart and make available for inspection ramp rigging. 46 CFR 176.610
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 October 2015
Resolved 17 August 2015
Resolution: All rigging including pulleys, pins, and brackets were taken apart and made available for inspection. Indentified one pulley bushing that had some wear. All SAT.
Construction/Loadline › Structures › Superstructure
Issued 11 August 2015
Resolved
Stbd ramp ram is leaking. Repair or replace ramp ram. 46 CFR 176.610
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 October 2015
Resolved 13 October 2015
Resolution: Starboard ram was taken and rebuilt. Also, port ram was rebuilt.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 10 June 2015
Resolved
Vessels main deck non-skid has worn awary due to high traffic of vehicles creating slipping hazard. Install some type of non-skid protection on main deck of vesssel. 46 CFR 179.830
Action required: 705 - Other - as specified
Due 31 August 2015
Resolved 27 July 2016
Resolution: Non slip surface was renewed.
Electrical › Electric Supply System (service) › Battery Installation
Issued 10 June 2015
Resolved
Vessels battery is not secured properly in place. Provide securing measures for battey. 46 CFR 183.350(b)
Action required: 705 - Other - as specified
Due 16 August 2015
Resolved 27 July 2016
Resolution: Batteries secured, covered.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 10 June 2015
Resolved
Vessel does not have name labeled on both port/stbd bow and hailing port located on stern. Properly label vessel. 46 CFR 185.602(a) / 46 CFR 67.123
Action required: 705 - Other - as specified
Due 16 August 2015
Resolved 27 July 2016
Resolution: Markings in place.
Construction/Loadline › Structures › Deck Plating
Issued 23 June 2010
Resolved
Replace cotter key on inboard pin for ramp support.
Due 7 July 2010
Resolved 12 July 2010
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 23 June 2010
Resolved
Restencile lifebuoy with the vsls name.
Due 7 July 2010
Resolved 12 July 2010
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 23 June 2010
Resolved
Vsls passenger count is reduced to 27 and 2 crew until additional lifejackets are provided.
Action required: 705 - Other - as specified
Resolved 12 July 2010
Documentation › Logs/Records › Logbook (official)
Issued 6 August 2008
Resolved
Log drills in training log book
Due 12 August 2008
Resolved 8 August 2008
Stability › Water on Deck › General
Issued 6 August 2008
Resolved
Repair/replace gasket hatches
Due 12 August 2008
Resolved 8 August 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 August 2008
Resolved
Replace eye wash in first aid kit
Due 12 August 2008
Resolved 8 August 2008
Documentation › Certificates/Documents › Certificate of Inspection
Issued 18 May 2007
Resolved
POST ALL REQUIRED CERTIFICATES IN PLAIN PASSENGER VIEW.
Action required: 705 - Other - as specified
Resolved 24 May 2007
Resolution: CLEARED
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 18 May 2007
Resolved
REPLACE AFT WINDOW ON TUG RAGS I.
Action required: 705 - Other - as specified
Resolved 24 May 2007
Resolution: CLEARED
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 18 May 2007
Resolved
REPLACE COVER ON JUNCTION BOX STBD SIDE OF LE BARGE
Action required: 705 - Other - as specified
Resolved 24 May 2007
Resolution: CLEARED
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 26 July 2006
Resolved
Pump dry number 3 port compartment.
Due 27 July 2006
Resolved 27 July 2006
Construction/Loadline › Hull › Weld
Issued 8 September 2005
Resolved
GOUGE AND RE-WELD BROKEN WELD ON PORT SIDE INSERT.
Due 30 September 2005
Resolved 16 September 2005
Construction/Loadline › Structures › Deck Plating
Issued 8 September 2005
Resolved
RENEW RAMP FRAMING WHERE WASTED AND GOUGE AND WELD FRACTURES.
Due 30 September 2005
Resolved 16 September 2005
Documentation › Logs/Records › Drug Test Records
Issued 20 July 2005
Resolved
Provide testing procedures for post serious marine incident.
Due 1 August 2005
Resolved 22 July 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 July 2005
Resolved
Repair inoperative running lights prior to operating at night or in periods of reduced visibility.
Due 1 August 2005
Resolved 22 July 2005
Construction/Loadline › Structures › Deck Plating
Issued 20 July 2005
Resolved
Make permanent repairs to the crack in main deck centerline. Drill stop-grind out, and weld.
Due 1 August 2005
Resolved 4 October 2005
Operations/Management › Navigation Safety › Requirements for Vessels at Anchor
Issued 20 July 2005
Resolved
Rig anchor with all line and associated tackle and make ready for deployment.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2005
Resolved 22 July 2005
Lifesaving › Lifebuoys › Quantity
Issued 20 July 2005
Resolved
Replace two wasted ring buoys to make full complement of three.
Due 1 August 2005
Resolved 4 October 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 July 2005
Resolved
Provide first aid kit with all required items.
Due 1 August 2005
Resolved 4 October 2005
Fire Fighting › Fire Pumps › Power Source
Issued 20 July 2005
Resolved
Make operable one fire pump to make full complement of three I.A.W. COI.
Due 1 August 2005
Resolved 22 July 2005
Resolution: Pump re-fueled and test ran.
Construction/Loadline › Structures
Issued 9 September 2003
Resolved
Renew bow ramp hinge pins.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 October 2003
Resolved 11 September 2003
Construction/Loadline › Structures
Issued 9 September 2003
Resolved
Renew lower port bow ramp chain to ramp connection bolt.
Due 9 October 2003
Resolved 11 September 2003
Communications › Audible Communications
Issued 22 May 2003
Resolved
Provide a public address system onboard tug.
Due 22 June 2003
Resolved 4 June 2003
Deck/Cargo › Towing
Issued 20 May 2002
Resolved
RENEW WORN PORT TUG/BARGE CONNECTING STRAP. LEGACY COMPONENT DESC: Towline
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 June 2002
Resolved 21 June 2002
Resolution: PURCHASED NEW STRAP.
Operations/Management › Drug and Alcohol Testing
Issued 20 May 2002
Resolved
SUBMIT TO MSD FT. MYERS A LIST OF EMPLOYEES ENROLLED IN THE DRUG TESTING PROGRAM AND PROVIDE EAP TRAINING FOR SAME EMPLOYEES. LEGACY COMPONENT DESC: Proof of Enrollment
Condition: Unknown
Due 20 June 2002
Resolved 21 June 2002
Resolution: DRUG TESTING REQUIREMENT CORRECTED.
Communications
Issued 20 May 2002
Resolved
PROVE PROPER OPERATION OF LOUDHAILER SYSTEM. LEGACY COMPONENT DESC: LOUDHAILER
Action required: 705 - Other - as specified
Due 20 June 2002
Resolved 21 June 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 20 May 2002
Resolved
PROVIDE PROOF OF FIRST AID/CPR TRAINING.
Due 20 June 2002
Resolved 21 June 2002
Lifesaving
Issued 27 May 1999
Resolved
INSTALL RETRO TAPE ON ALL RING BUOYS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 June 1999
Resolved 1 July 1999
Lifesaving
Issued 27 May 1999
Resolved
STORE FLARES IN BRIGHT COLORED WATERTIGHT CONTAINER, LABEL DISTRESS SIGNALS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 June 1999
Resolved 1 July 1999
Fire Fighting
Issued 27 May 1999
Resolved
PROVIDE 2 NFPA APPROVED 1 1/2" FIRE HOSES PRIOR TO CARRYING PASSENGERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 June 1999
Resolved 1 July 1999
Electrical
Issued 27 May 1999
Resolved
REMOVE ABANDON WIRING PORT AFT SIDE OF VESSEL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 June 1999
Resolved 1 July 1999
Navigation
Issued 27 May 1999
Resolved
INSTALL 30" NAVIGATION LIGHT SHIELDS ON NAVIGATION LIGHTS, P/S._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 June 1999
Resolved 1 July 1999
Construction/Loadline
Issued 27 May 1999
Resolved
REATTACH/REWELD DECK ALONG CENTERLINE TO UNDER DECK FRAMING._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 June 1999
Resolved 1 July 1999