MAURY USCG vessel records
← All vessels

LYKES INNOVATOR *

Built
1960
Last inspected
2 August 1996
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 30 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 2 August 1996
…with no type recorded34
Operational controls None recorded without a removal date
Years with a record 15 calendar years (1981–1996)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

5175800
Flag
UNITED STATES
Maury page id
psix-43861

Documentation record

Tonnage as PSIX records it10796 - Regulatory (Subpart C or D), Gross Ton
8163 - Regulatory (Subpart C or D), Net Ton
14515 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 61 inspections, each with its date, unit and type; 48 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 61

2 August 1996 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1089576
7 September 1994 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1387603
25 July 1994 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1176446
7 March 1994 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1166149
1 November 1993 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 362139
21 October 1993 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 848395
21 April 1993 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1142542
28 December 1992 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1141266
23 December 1992 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 828341
14 September 1992 COI Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1258491
6 April 1992 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 948494
26 December 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1255809
12 November 1991 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 937439
21 May 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1029297
20 May 1991 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 924483
12 December 1990 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 930420
12 July 1990 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 452209
17 April 1990 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 925585
25 March 1990 Examination of Repairs
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 907787
16 March 1990 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1236726
15 March 1990 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1239970
10 March 1990 Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 911243
14 February 1989 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1346787
10 February 1989 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1036830
7 October 1988 Examination of Repairs
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 893816
3 July 1988 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 895256
2 July 1988 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 476933
16 June 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 889341
25 April 1988 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1343639
21 April 1988 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1342719
12 February 1988 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1336363
17 November 1987 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 441951
18 September 1987 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1315104
11 September 1987 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1007031
21 April 1987 Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1000848
9 March 1987 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1011357
4 March 1987 COI Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1009354
10 December 1986 Damage Survey
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1330121
7 November 1986 Administrative
Administrative · Commandant (CG-CVC) · Activity 1322482
27 September 1986 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 494617
25 September 1986 MARPOL Annex I Examination
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1311936
24 September 1986 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1311364
6 May 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1294945
2 May 1986 Examination of Repairs
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 990884
14 February 1986 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1294695
9 December 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 506905
4 December 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1301206
22 August 1985 Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1295644
3 April 1985 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1287519
31 March 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1287694
28 March 1985 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1288706
11 January 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1289579
6 November 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1286897
20 August 1984 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 975149
17 May 1984 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 973623
7 September 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 969004
25 May 1983 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 967155
9 June 1982 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 970997
5 March 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272467
12 February 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272476
8 May 1981 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1271542

Deficiency record · 48

Construction/Loadline
Issued 7 March 1994 Resolved
PROVIDE ABS APPROVAL OF REPAIRS MADE IN WAY OF OLD TOWING EYE FAILURE ON STEM OF FOREPEAK BETWEEN DRAFT MARKS 30' AND 32'.
Condition: Unknown
Due 7 March 1994
Resolved 7 March 1994
Construction/Loadline
Issued 14 September 1992 Resolved
SUBMIT TO ABS DRAWINGS FOR NEW ACCESS LADDER IN HULL DETAILS AS PER ABS LETTER DATED 10JUN92.
Condition: Unknown
Due 14 September 1992
Resolved 14 September 1992
Construction/Loadline
Issued 14 September 1992 Resolved
ADDITIONAL SUPPORTING STRUCTURE (IN THE FORM OF HEADERS OR BRACKETS AS REQUIRED) SHALL BE INSTALLED AT TANK TOP LEVEL IN WAY OF (4) VERTICAL STANTIONS LOCATED PORT AND STARBOARD AT FRAMES 129 & 142 OF NO. 6 CARGO HOLD. FOR FURTHER DETAILS SEE ABS LETTER DATED 29APR92.
Condition: Unknown
Due 14 September 1992
Resolved 14 September 1992
Electrical
Issued 14 September 1992 Resolved
PROVIDE DOCUMENTATION THAT INSTALLED SOLAR POWERED BATTERY CHARGER MEETS_x001C_ UL STANDARD 1236 INCLUDING MARINE SUPPLIMENT IN ACCORDANCE WITH 46 CFR _x001C_ 111.15-30.
Condition: Unknown
Due 14 September 1992
Resolved 14 September 1992
Accommodation/Occupational Safety
Issued 12 December 1990 Resolved
MAKE DC HEATER AVAILABLE FOR INTERNAL EXAMINATION.
Condition: Unknown
Due 12 December 1990
Resolved 12 December 1990
Lifesaving
Issued 12 December 1990 Resolved
CLEAN OUT RUST AND DIRT FROM DAVIT TRACKS FOR BOTH LIFEBOATS FOR FURTHER EXAMINATION OF WASTAGE OF THE TRACKS.
Condition: Unknown
Due 12 December 1990
Resolved 12 December 1990
Engineering
Issued 10 March 1990 Resolved
EFFECT REPAIRS AND PROVE PROPER OPERATION OF STEAM DRIVEN LUBE OIL SERVICE_x001C_PUMP PRIOR TO SAILING FOREIGN OR NO LATER THAN 20 MARCH 1990._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 March 1990
Resolved 10 March 1990
Lifesaving
Issued 10 February 1989 Resolved
SUBMIT FOR REVIEW AND APPROVAL PROPOSAL FOR ALTERNATIVE LIFERAFT STOWAGE LOCATIONS AND ARRANGMENTS TO COMPLY WITH 46 CFR 94.15-10(A), 94.15-10(C)(4)AND NVIC 4-86
Condition: Unknown
Due 10 February 1989
Resolved 10 February 1989
Lifesaving
Issued 10 February 1989 Resolved
WEIGHT TEST STARBOARD LIFEBOAT IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR. 46 CFR 91.25-15(A)(2)
Condition: Unknown
Due 10 February 1989
Resolved 10 February 1989
Engineering
Issued 10 February 1989 Resolved
MAKE REPAIRS TO AND DEMONSTRATE PROPER OPERATION OF VESSEL'S OILY WATER SEPARATOR AND BILGE ALARM (15 PPM). 33 CFR 155.380
Condition: Unknown
Due 10 February 1989
Resolved 10 February 1989
Navigation
Issued 3 July 1988 Resolved
MAKE PERMANENT REPAIRS TO THE SECOND MARINE RADAR SYSTEM.
Condition: Unknown
Due 3 July 1988
Resolved 3 July 1988
Navigation
Issued 21 April 1988 Resolved
REPAIR OR REPLACE INOPERABLE RADAR PRIOR TO DEPARTING PORT OF BEAUMONT. CAPTAIN OF THE PORT HAS AUTHORIZED VOYAGE FROM LAKE CHARLES, LA TO BEAUMONT, TX WITH ONE RADAR.
Condition: Unknown
Due 21 April 1988
Resolved 21 April 1988
Unknown
Issued 18 September 1987 Resolved
REPAIR OR REPLACE THE INOPERATIVE RADAR PRIOR TO DEPARTURE FROM THE NEXT PORT OF CALL.
Condition: Unknown
Due 18 September 1987
Resolved 18 September 1987
Fire Fighting
Issued 4 March 1987 Resolved
PROVIDE MEANS TO PREVENT PERSONNEL FROM BEING TRAPPED IN C02 CYLINDER STO- RAGE ROOM UPON OVER-PRESSURIZATION OF SPACE. THIS COULD INCLUDE MAKING DOOROPEN OUTWARDS, REPLACINGDOOR WITH EXPANDED METAL DOOR, OR OTHER ARRANGEMENTACCEPTABLE TO THE COGNIZANT OCMI.
Condition: Unknown
Due 4 March 1987
Resolved 4 March 1987
Navigation
Issued 4 March 1987 Resolved
INCREASE HORIZONTAL SEPARATION BETWEEN MASTHEAD LIGHTS TO A DISTANCE EQUAL TO AT LEAST ONE-HALF THE SHIP'S LENGTH IN ACCORDANCE WITH 33CFR81-ANNEX I. THIS TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT OCMI NOT LATER THAN THE NEXT SCEDULED DRYDOCKING.
Condition: Unknown
Due 4 March 1987
Resolved 4 March 1987
Engineering
Issued 3 April 1985 Resolved
MAKE THE FOLLOWING NONMETALLIC EXPANSION JOINTS AVAILABLE FOR INSPECTION: 1. JOINT-SUCTION SIDE OF MAIN CIRCULATION PUMP. 2. JOINT-SUCTION AFT AUX. CONDENSER.
Condition: Unknown
Due 3 April 1985
Resolved 3 April 1985
Engineering
Issued 28 March 1985 Resolved
INSTALL SPRAY SHIELDS IN ALL FLANGED JOINTS ON BOILER FUEL OIL PIPING BETWEEN FUEL OIL HEATERS AND BURNERS (46CFR56.50-65(E)).
Condition: Unknown
Due 28 March 1985
Resolved 28 March 1985
Fire Fighting
Issued 28 March 1985 Resolved
PROVIDE LABELS FOR SHUTDOWN SWITCHES FOR CO2 SYSTEM TO MACHINERY SPACE.
Condition: Unknown
Due 28 March 1985
Resolved 28 March 1985
Electrical
Issued 28 March 1985 Resolved
RELABEL VENTILATION REMOTE SHUTDOWNS ON BRIDGE SO LABELS PROPERLY COR- RESPOND TO SHUTDOWN.
Condition: Unknown
Due 28 March 1985
Resolved 28 March 1985
Electrical
Issued 28 March 1985 Resolved
REMOVE HEAT LAMPS (PORTABLE TYPES) FROM AFT STEERING ROOOM AND SHAFT ALLEY.
Condition: Unknown
Due 28 March 1985
Resolved 28 March 1985
Construction/Loadline
Issued 28 March 1985 Resolved
CONDUCT OPERATIONAL AND LEAK TEST OF ALL CARGO HOLD BATCH COVERS.
Condition: Unknown
Due 28 March 1985
Resolved 28 March 1985
Electrical
Issued 28 March 1985 Resolved
REMOVE PORTABLE LIGHTS/CABLES FROM BOW THRUSTER SPACE.
Condition: Unknown
Due 28 March 1985
Resolved 28 March 1985
Lifesaving
Issued 28 March 1985 Resolved
RENEW RUDDER ON STBD LIFEBOAT. BOAT SHALL BE EQUIPED WITH A SWEEP OAR UNTILREPLACEMENT RUDDER IS PROVIDED.
Condition: Unknown
Due 28 March 1985
Resolved 28 March 1985
Lifesaving
Issued 28 March 1985 Resolved
PROVIDE SEVEN (7) ADDITIONAL EXPOSURE SUITS FOR A TOTAL OF 67, AND INSURE THAT ALL ARE EQUIPED WITH LIGHTS AND HAVE THE VESSEL NAME STENCILLED ON ALLSUITS.
Condition: Unknown
Due 28 March 1985
Resolved 28 March 1985
Construction/Loadline
Issued 28 March 1985 Resolved
CLEAN AND TEST THE FOLLOWING BILGE SUCTION LINES: NO.2 CARGO HOLD STBD SIDENO.4 CARGO HOLD PORT & STBD SIDE, NO.5 CARGO HOLD PORT SIDE.
Condition: Unknown
Due 28 March 1985
Resolved 28 March 1985
Lifesaving
Issued 28 March 1985 Resolved
CONDUCT WEIGHT TEST OF PORT LIFEBOAT.
Condition: Unknown
Due 28 March 1985
Resolved 28 March 1985
Construction/Loadline
Issued 28 March 1985 Resolved
RENEW WASTED SECTION OF BILGE SUCTION PIPING AT THE STBD ROSEBOX IN NO.5 CARGO HOLD.
Condition: Unknown
Due 28 March 1985
Resolved 28 March 1985
Construction/Loadline
Issued 28 March 1985 Resolved
REMOVE DRESSER STYLE COUPLINGS FROM SUCTION LINE FOR CHAIN LOCKER, AND REPLACE WITH EITHER WELDED FLANGED OR SCREWED JOINT. SUBMIT PROPOSAL FOR NEW JOINT TO THIS OFFICE FOR APPROVAL. (JOINTS LOCATED IN LOWER BOW THRUSTER SPACE).
Condition: Unknown
Due 28 March 1985
Resolved 28 March 1985
Electrical
Issued 28 March 1985 Resolved
INSTALL PROPER SIZE LIGHT BULBS AND REINSTALL LAMP GUARDS TO LIGHTS IN BOW THRUSTER SPACE.
Condition: Unknown
Due 28 March 1985
Resolved 28 March 1985
Engineering
Issued 28 March 1985 Resolved
REPLACE STARBOARD BOILER SUPERHEATER SAFETY VALVE WITH VALVE OF APPROVED TYPE (EXISTING VALVE HAS NO MANUFACTURER'S TAG)
Condition: Unknown
Due 28 March 1985
Resolved 28 March 1985
Unknown
Issued 28 March 1985 Resolved
SUBMITTED UPDATED OIL TRANSFER PROCEDURES FOR APPROVAL WHICH COMPLY WITH 33CFR SUBPART "C".
Condition: Unknown
Due 28 March 1985
Resolved 28 March 1985
Engineering
Issued 28 March 1985 Resolved
RENEW FLANGE GASKET ON PORT BOILER MAIN STEAM STOP VALVE.
Condition: Unknown
Due 28 March 1985
Resolved 28 March 1985
Unknown
Issued 28 March 1985 Resolved
INSTALL PERMANENT TYPE OIL DRUM HOLDERS FOR STEERING GEAR OIL IN STEERING FLAT. (ROPE IS NOT ACCEPTABLE).
Condition: Unknown
Due 28 March 1985
Resolved 28 March 1985
Unknown
Issued 28 March 1985 Resolved
INSTALL SHAFT GUARDS ON 1. MAIN CIRCULATION PUMP. 2. DISTILATE PUMP. AND 3. SANITARY PUMP.
Condition: Unknown
Due 28 March 1985
Resolved 28 March 1985
Unknown
Issued 28 March 1985 Resolved
RENEW FOLLOWING NON-METALLIC EXPANSION JOINTS: 1.JOINT-SUCTION SIDE MAIN CIRCULATION PUMP; 2. JOINT-CONDENSER OVBD; 3. FWD AUX. CONDENSER SUCTION. ENGINEER SHALL CHECK CONDITION OF JOINTS DAILY UNTIL REPLACED. RECORD THIS IN LOG NEW JOINTS MUST BE SHOWN TO COMPLY WITH 46CFR56.60-25(E).
Condition: Unknown
Due 28 March 1985
Resolved 28 March 1985
Unknown
Issued 28 March 1985 Resolved
MAKE PERMANENT REPAIRS TO REACH RODS TO FOLLOWING VALVES: 1. SHAFT ALLEY BILGE SUCTION; 2. FUEL OIL DEEP TANK NO.4 PORT AND STBD; 3. FUEL OIL DEEP TANK NO.5 STARBOARD.
Condition: Unknown
Due 28 March 1985
Resolved 28 March 1985
Engineering
Issued 28 March 1985 Resolved
REPLACE PORT BOILER FWD DRUM SAFETY VALVE WITH APPROVED TYPE (EXISTING HAS SET PRESSURE ABOVE VALVE DESIGN PRESSURE).
Condition: Unknown
Due 28 March 1985
Resolved 28 March 1985
Engineering
Issued 28 March 1985 Resolved
REPLACE DRUM SAFETY VALVES (FORE & AFT) ON STBD BOILER WITH APPROVED TYPE VALVES. (EXISTING VALVES HAVE SET PRESSURE ABOVE DESIGN PRESSURE)
Condition: Unknown
Due 28 March 1985
Resolved 28 March 1985
Engineering
Issued 28 March 1985 Resolved
REPLACE BOLTS ON STBD BOILER FWD SAFETY EXHAUST FLANGE. BOLTS MUST EXTEND 100% THRU NUTS. BOLTS MUST BE PER BOILER DWG.
Condition: Unknown
Due 28 March 1985
Resolved 28 March 1985
Engineering
Issued 28 March 1985 Resolved
RENEW EXHAUST HOSE ON PORT BOILER AFT DRUM SAFETY VALVE. PRIOR TO FABRI- CATION, PLANS MUST BE SUBMITTED TO THIS OFFICE FOR APPROVAL ALONE WITH COP-IES OF APPROVED WELD PROCEDURES AND WELDER QUALIFICATIONS. TEMPORARY REPAIRWILL BE CHECKED ON A DAILLY BASES BY [name withheld] LOGGED-IN.
Condition: Unknown
Due 28 March 1985
Resolved 28 March 1985
Engineering
Issued 28 March 1985 Resolved
RENEW EXHAUST HOSE ON STBD BOILER FWD SAFETY VALVE. PRIOR TO FABRICATION, PLANS MUST BE SUBMITTED TO THIS OFFICE FOR APPROVAL ALONG WITH COPIES OF APPROVED WELD PROCEDURES & WELDER QUALIFICATION. TEMPORARY REPAIRS WILL BE CHECKED ON A DAILLY BASIS BY [name withheld] RECORDED IN LOG.
Condition: Unknown
Due 28 March 1985
Resolved 28 March 1985
Electrical
Issued 28 March 1985 Resolved
REMOVE PORTABLE POWER CABLES TO TWO FANS IN MACHINE SHOP & REPLACE WITH FIXED TYPE WIRING.
Condition: Unknown
Due 28 March 1985
Resolved 28 March 1985
Electrical
Issued 28 March 1985 Resolved
REMOVE PORTABLE LIGHT OVER LATHE & REPLACE WITH FIXED INSTALLATION.
Condition: Unknown
Due 28 March 1985
Resolved 28 March 1985
Electrical
Issued 28 March 1985 Resolved
RENEW POWER PANEL LATCHES TO FOLLOWING PANELS: 1. PANEL NO. 3-124-2 2. PANEL NO. 1-131-3 (NEAR FIRE STA NO.23) 3. PANEL NO. 2-102-1 (PUMP ROOM)
Condition: Unknown
Due 28 March 1985
Resolved 28 March 1985
Unknown
Issued 28 March 1985 Resolved
INSTALL GENERAL ALARM BELLS SO THEY CAN BE HEARD IN UPPER CASING NEAR FORCED DRAFT FANS, GENERATOR FLAT AND AIR COMPRESSOR FLAT. IAW 46CFR113.25-9(A)&(B); AND MARKED IAW 46CFR97.37-7
Condition: Unknown
Due 28 March 1985
Resolved 28 March 1985
Electrical
Issued 28 March 1985 Resolved
REMOVE PORTABLE LIGHT INSTALLATION IN OVERHEAD OUTSIDE ENGINEER/ELECTRICAL GEAR LOCKER.
Condition: Unknown
Due 28 March 1985
Resolved 28 March 1985
Unknown
Issued 28 March 1985 Resolved
PROPERLY MARK GENERAL ALARM BELLS IN BOW THRUSTER SPACE (2). 46CFR97.37.7
Condition: Unknown
Due 28 March 1985
Resolved 28 March 1985
Fire Fighting
Issued 28 March 1985 Resolved
PROVIDE SHUTDOWN OF FORCED DRAFT FANS WHEN ENGINEROOM CO2 SYSTEM ENERGIZED.
Condition: Unknown
Due 28 March 1985
Resolved 28 March 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.