MAURY USCG vessel records
← All vessels

SINCLAIR MIDSTREAM FUELER NO. 1

Built
1960
Last inspected
3 February 2012
Documentation
Invalid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 3 February 2012
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 23 calendar years (1985–2012)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-43863

Documentation record

Registered dimensions (L × B × D)115.0 ft
Registered tonnagegross 192 / net 192
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilt 1960
Hull materialSteel
PropulsionUnknown
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNot recorded
Endorsements, as the file codes themNot recorded
DocumentationInvalid
Service, as the file records itTank Barge
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it192 - Regulatory (Subpart C or D), Gross Ton
192 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 38 inspections, each with its date, unit and type; 6 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 38

3 February 2012 Administrative Inspection
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4237890
17 January 2012 Damage Survey · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4226322
10 November 2010 Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3888940
10 February 2010 Administrative Inspection
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3678053
18 February 2009 Annual Inspection · MTSA Verification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3415603
5 February 2008 Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3142219
21 November 2006 MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2826293
17 May 2006 Construction Oversight
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2651774
15 March 2006 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2603228
15 February 2006 MTSA Verification · Annual Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2581630
6 September 2005 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2485356
24 May 2005 Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2366611
19 April 2005 MTSA Verification
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 2338034
16 December 2004 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2260441
22 November 2004 COI Inspection · Examination of Repairs · Internal Structural Exam · Hull Examination · Cargo Tank Internal
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2246695
15 June 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2099341
11 February 2004 Periodic Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 2006014
22 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1968404
17 January 2003 Periodic Inspection · Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1731875
11 December 2002 Periodic Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1717447
21 November 2001 COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1435302
26 January 2001 Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1444451
9 February 2000 Administrative
Administrative · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1046331
2 December 1999 COI Inspection · Hull Examination
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1399235
18 November 1998 COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1453534
31 August 1998 Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 796816
25 November 1996 COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1406004
22 December 1995 Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 885507
28 November 1994 Hull Examination · COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 869394
18 October 1993 COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1155759
25 November 1991 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 455508
8 November 1991 COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 827343
7 December 1990 Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1237875
18 December 1989 COI Inspection · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 913042
20 January 1989 COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 889989
24 February 1988 Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1334443
22 January 1987 COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1011809
3 May 1985 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 981033

Deficiency record · 6

Construction/Loadline › Hull › Bottom Plating
Issued 17 January 2012 Resolved
Barge has a 1" fracture in the bottom of the stbd bildge knuckle of the #2 stbd cargo tank.
Action required: 705 - Other - as specified
Resolved 17 January 2012
Electrical › Electric Supply System (service) › Battery Installation
Issued 21 November 2006 Resolved
Battery box was not sealed (intrinsically safe) or properly vented.
Action required: 705 - Other - as specified
Resolved 21 December 2006
Resolution: Battery box was replaced with intrinsically safe box and appropriate venting.l
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 15 February 2006 Resolved
Barge documentation did not contain current transfer hose records for hoses 1604 1-6
Condition: Placed in Improper Service
Due 28 February 2006
Resolved 16 February 2006
Resolution: Transfer hose test records provided to inspector and added to barge documents.
Electrical › Electric Generation Source (service) › Generator Cable
Issued 15 February 2006 Resolved
Battery wiring lacking protective covering to make it intrinsically safe.
Condition: Improper/Lack of Maintenance
Due 30 May 2006
Resolved 5 May 2006
Resolution: rubber boots placed on battery
Pollution Prevention/Response › Response Equipment
Issued 11 December 2002 Resolved
Provide Discharge Removal Equipment in accordance with Title 33 CFR Part 155.215 LEGACY COMPONENT DESC: Sorbents
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 January 2003
Resolution: Discharge removal equipment was provided onboard.
Electrical
Issued 3 May 1985 Resolved
PROVIDE AN APPROVED ELECTRICAL WIRING DIAGRAM AND TO POST IT ON THE INSIDE OF THE MAIN PANEL.
Condition: Unknown
Due 3 May 1985
Resolved 3 May 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.