MAURY USCG vessel records Sign in
← All vessels

VICTORY

VICTORY is a 1960 passenger vessel (inspected). The Coast Guard has recorded 54 inspections since 1984, most recently in February 2025, along with 60 deficiencies and 4 casualty investigations between 2006 and 2009.

Records from 1984 to 2025. Most recent: inspection, 12 February 2025.

Built
1960
Last inspected
12 February 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDB7755
Flag
UNITED STATES
366947540 (licence lapsed)
Maury page id
psix-43870

Inspections, by type

…with no type recorded10
Years with a record 30 calendar years (1984–2025)
The 54 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)63.7 ft × 15.3 ft × 4.8 ft
Registered tonnagegross 14 / net 9
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJ W NOLAN & SONS, INC · ERIE, PA, UNITED STATES · built 1960
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portERIE, PA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 20 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Regulatory (Subpart C or D), Gross Ton
9 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDB7755MMSI 366947540 · expired · compulsorily equipped · granted 14 May 2004, cancelled 19 July 2014
WCW5397MMSI not assigned · expired · compulsorily equipped · granted 6 May 1996, cancelled 8 July 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 54

12 February 2025 Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8078848
11 August 2022 Drydock Exam
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7536470
27 November 2018 COI Inspection · Construction Oversight
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6586670
20 April 2017 Drydock Exam · Welding Related Inspections Qualification Testing
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6129203
20 July 2009 Internal Structural Exam · Drydock Exam
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3660141
15 February 2009 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3419609
19 May 2008 Re-Inspection · Plan Review "T" Boat · DAPI Audit
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3261783
17 May 2007 Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2933203
14 May 2007 Re-Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2930946
28 August 2006 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2763807
22 August 2006 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2763953
18 August 2006 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2758228
20 April 2006 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2749718
19 April 2006 Deficiency Check · COI Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2628410
16 May 2005 Periodic Inspection · Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2381633
21 April 2005 Hull Examination
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2337220
4 June 2004 Annual Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2088623
31 July 2003 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1862393
11 July 2002 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1645046
21 August 2001 Administrative
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1072454
15 May 2001 Administrative
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1064969
10 May 2001 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1433830
18 April 2000 Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1446913
24 May 1999 Plan Review "T" Boat · Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 800029
22 May 1998 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 791899
2 May 1997 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1107126
6 June 1996 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1183233
3 May 1996 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1083730
21 June 1995 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 879905
31 May 1995 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1394331
3 May 1995 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 847261
17 March 1995 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1138605
15 February 1995 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1153141
6 May 1994 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1168332
3 May 1994 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1168534
17 May 1993 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 962803
3 May 1993 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1150129
30 June 1992 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1134384
10 May 1991 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1249971
9 May 1991 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1233929
27 April 1991 Re-Inspection · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1235122
3 May 1990 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 912318
16 May 1989 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 891993
25 April 1989 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1198152
2 May 1988 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1037380
28 April 1987 Hull Examination · COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1003494
11 July 1986 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1306640
30 May 1986 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 985509
21 May 1986 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 997364
5 May 1986 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1292851
29 April 1986 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1000880
28 April 1986 Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1000879
21 June 1985 Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1292314
15 May 1984 COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1297329

Deficiency record · 60

Electrical › Electrical Distribution System (service) › Wiring
Issued 20 July 2009 Resolved
Submit replacement plan for the entire electrical system prior to further installation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2025
Construction/Loadline › Hull › Hull Plating
Issued 20 July 2009 Resolved
Complete credit drydock exam and make repairs required on worklist from Act #3660141.
Action required: 705 - Other - as specified
Resolved 12 February 2025
Resolution: Vessel will be required to complete a credit drydock if it enters back into service.
Engineering › Bilge Water Management System › Piping
Issued 19 May 2008 Resolved
Install pipe with pickup and strainer within the void number 2.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 May 2008
Resolved 30 May 2008
Resolution: Adequate arrangement installed with satisfactory test of system witnessed.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 19 May 2008 Resolved
Vessel is limited to within 1 mile from shore until plans are submitted to this office of a means to decrease volume of voids 3 and 4 by 2 foot gross volume of each space. Approved modifications must be completed and verified by this office.
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 12 February 2025
Resolution: Vessel will be required to submit plans to MSC if it enters back into service.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 19 May 2008 Resolved
Replace retro tape on 4 adult and 3 child jackets prior to commercial operations.
Due 19 May 2008
Resolved 23 May 2008
Resolution: Visited vessel at ship yard and witnessed replacement retro reflective tape affixed.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 19 May 2008 Resolved
Secure Pepsi cooler to prevent movement and personnel injury.
Due 19 May 2008
Resolved 23 May 2008
Resolution: Witnessed cooler secured to bulkhead.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 May 2007 Resolved
Replenish supplies in first aid kit
Due 14 June 2007
Resolved 19 May 2008
Resolution: During annual inspection inventory of first aid kit provided all required items present with valid expiration dates.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 14 May 2007 Resolved
Repair leak in inlet pipe to MSD holding tank
Due 14 June 2007
Resolved 19 May 2008
Resolution: Inspection of system provided repairs completed satisfactory with new piping installed.
Communications › Alarms/Indicators › High Water Alarm
Issued 14 May 2007 Resolved
Repair float switch for engine room high water alarm
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 May 2007
Resolved 17 May 2007
Resolution: visited vessel and tested alarm
Communications › Radio Communications › EPIRB
Issued 20 April 2006 Resolved
replace hydrostatic release on EPIRB and affix current registration decal. Operation restricted to 3 mile form shore
Due 20 May 2006
Resolved 31 May 2006
Fire Fighting › Fire Main › Pressure
Issued 16 May 2005 Resolved
prior to commercial operation prove proper operation of installed bilge/fire pump to the satisfaction of the attending CG marine inspector
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 June 2005
Resolved 14 June 2005
Resolution: Witnessed satisfactory operation of installed fire/bilge pump dewatering lazarette as well as spraying water from installed hose during emergency drills.
Engineering › Bilge Water Management System › Manifold
Issued 16 May 2005 Resolved
Properly label bilge manifold as to space alignment, and demonstrate knowledge of system.
Due 16 June 2005
Resolved 14 June 2005
Resolution: Witnessed satisfactory marking of systems with operational check completed.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 16 May 2005 Resolved
place cap on toip fitting of msd holding tank
Due 21 May 2005
Resolved 3 June 2005
Resolution: cap installed
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 May 2005 Resolved
replace wiring in way of engine where protective coating is worn. ensure all wires have metal supports in way of engine space
Due 16 June 2005
Resolved 3 June 2005
Resolution: wires replaced, wiring protection installed
Engineering › Steering Gear System › Hydraulic Hose
Issued 16 May 2005 Resolved
replace hydraulic line on aft engine. worn coating.
Due 16 June 2005
Resolved 3 June 2005
Resolution: line is replaced
Electrical › Electric Generation Source (service) › Generator
Issued 16 May 2005 Resolved
Prior to commercial operations prove proper operation of electrical charging system. (Note: check on 3 JUN05 shows that a new engine driven alternator was improperly installed, the alternator pulley does not line up with the engine crankshaft pulley.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 June 2005
Resolved 14 June 2005
Resolution: Witnessed satisfactory operation of installed system with the replacement of alternator and belt. Charging system properly functions as designed and installed.
Fire Fighting › Fire Pumps › Power Source
Issued 16 May 2005 Resolved
replace broken engine drive wheel for fire pump
Due 16 June 2005
Resolved 3 June 2005
Resolution: drive wheel replaced
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 May 2005 Resolved
Properly install battery cable to starter with adequate protection.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 May 2005
Resolved 14 June 2005
Resolution: Witnessed replacement of several cables IWO engine space to include battery cable to starter, run has adequate protection from chaffing from deck plating and other surfaces.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 May 2005 Resolved
Properly install protection for wires which run between batteries and engine, replace as necessary.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2005
Resolved 14 June 2005
Resolution: Witnessed replacement of several cables IWO engine space to include battery cables, run have adequate protection from chaffing from deck plating and other surfaces.
Engineering › Sea-water System (primary cooling) › Valve
Issued 16 May 2005 Resolved
Install valve for electric pump in enginer room IAW 46cfr182.520(e)(7)
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 June 2005
Resolved 14 June 2005
Resolution: Witnessed proper installation of sea valve IAW above regulation.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 May 2005 Resolved
remove all deadended wires in engine space
Due 16 August 2005
Resolved 3 June 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 16 May 2005 Resolved
prove proper operation of fire extinguisher bracket in pilot house
Due 21 May 2005
Resolved 6 June 2005
Resolution: proper bracket installed
Communications › Alarms/Indicators › High Water Alarm
Issued 16 May 2005 Resolved
properly secure wires in lazarette for bilge high water alarm.
Due 21 May 2005
Resolved 6 June 2005
Resolution: wiring is secured
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 16 May 2005 Resolved
Provide segregate child and adult life jackets stowed in forward locker.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 June 2005
Resolved 14 June 2005
Resolution: Witnessed proper segregation with wooden divider provided, with appropriate markings affixed.
Operations/Management › Drills/Instruction › Not Conducted
Issued 16 May 2005 Resolved
Prior to commercial operation demonstrate underway operations and emergency drills ( Note: attempted to conduct underway drills on 03 JUN 05, drills suspended by CG inspector, crew unable to activate fire pump and had generally no knowledge of installed systems or procedures).
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 June 2005
Resolved 14 June 2005
Resolution: Complete satisfactory underway emergency drills with all hands training with the operation of installed equipment and procedures for operation.
Lifesaving › Lifefloat › Serviceable
Issued 4 June 2004 Resolved
repair or replace defective life floats vessel limited to 1 nautical mile from shore with passengers for hire until corrected
Due 3 August 2004
Resolved 3 August 2004
Resolution: replaced 2 lifefloats, and repaired 2 lifefloats
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 31 July 2003 Resolved
Reflective tape on some of the PFD's need to be replaced during 03-04 winter lay-up. LEGACY COMPONENT DESC: Retroreflective Material
Due 1 May 2004
Resolved 3 August 2004
Electrical
Issued 31 July 2003 Resolved
Indicator light needs to be added to control panel in pilot house for automatic bilge pump.
Condition: Unknown
Due 31 August 2003
Resolved 4 September 2003
Resolution: 04SEP03: Spoke with Bob Stousmeyer by phone and he assured me that the indicator light for the automatic bilge pump was installed on the control panel and is operating properly. T. Spears
Lifesaving › Buoyant Apparatus › Serviceable
Issued 31 July 2003 Resolved
Life floats are deterioated from sunlight and have cracks and holes. They need to be replaced or repaired with manufacture approved material during 03-04 winter lay-up.
Due 1 May 2004
Resolved 3 August 2004
Construction/Loadline
Issued 3 May 1996 Resolved
MSD VENT LINE(STBD SIDE) 06 INCHES DOWN FROM THE MAIN DECK WAS REMOVED BY THE CREW AND NOT REPLACED. THRU HULL FITTING IS TO BE REPAIRED OR REPLACED AND LINE IS TO BE RE FASTENED TO CONNECTION.
Condition: Unknown
Due 3 May 1996
Resolved 3 May 1996
Construction/Loadline
Issued 31 May 1995 Resolved
REPAIR THE DEFECTIVE WELD ON THE AFTER ENGINEROOM BULKHEAD WHICH ALLOWS PASSAGE OF LIQUID. WELD IS AT THE PENETRATION FOR BILGE PIPING. DEMONSTRATE PROPER INTEGRITY OF THE BULKHEAD AND OPERATION OF THE BILGE SYSTEM TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 31 May 1995
Resolved 31 May 1995
Electrical
Issued 3 May 1995 Resolved
REPLACE ALL BURNED OUT "E" LIGHTS AND DEMONSTRATE OPERATION.
Condition: Unknown
Due 3 May 1995
Resolved 3 May 1995
Lifesaving
Issued 3 May 1995 Resolved
PROVIDE (4) ADDITIONAL CG APPROVED TYPE I ADULT LIFEJACKETS PRIOR TO CARRYING MORE THAN 107 ADULTS TOTAL.
Condition: Unknown
Due 3 May 1995
Resolved 3 May 1995
Construction/Loadline
Issued 3 May 1995 Resolved
PROVIDE BILGE PIPING TO AFTER STEERING COMPARTMENT IN ACCORDANCE WITH 46 CFR 182.25-5 AND 182.40-5.
Condition: Unknown
Due 3 May 1995
Resolved 3 May 1995
Construction/Loadline
Issued 17 March 1995 Resolved
PUMP EXCESSIVE WATER FROM ALL BILGES PRIOR TO COMPLETION OF DRYDOCK EXAM.
Condition: Unknown
Due 25 March 1995
Resolved 25 March 1995
Construction/Loadline
Issued 17 March 1995 Resolved
VEE OUT AND REWELD CRACKED WELD IN AREA OF AFT SHAFT BEARING AND KEEL. LENGTH OF WELD IS 1.5 INCHES.
Condition: Unknown
Due 25 March 1995
Resolved 25 March 1995
Fire Fighting
Issued 3 May 1994 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVIDE PROPER SERVICING OF ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Lifesaving
Issued 3 May 1994 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVIDE SIX ORANGE SMOKE FLARES.
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Fire Fighting
Issued 3 May 1993 Resolved
REPLACE OR HYDRO TEST/SERVICE ONE (1) B-II FIRE EXTINGUISHER PRIOR TO CARRYING PASSENGERS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 May 1993
Resolved 5 May 1993
Lifesaving
Issued 3 May 1993 Resolved
NUMBER OF PASSENGERS RESTRICTED TO ONE-HUNDRED & FOUR (104) ADULTS, UNTIL FOUR (4) ADDITIONAL ADULT USCG APPROVED TYPE I LIFE PRESERVERS ARE PROVIDED.
Condition: Unknown
Due 3 May 1993
Resolved 3 May 1993
Construction/Loadline
Issued 30 June 1992 Resolved
STENCIL NAME OF VESSEL ON PORT AND STBD SIDE HULL IN BLOCK LETTERS AS _x001C_ FAR FOREWORD AS POSSIBLE.
Condition: Unknown
Due 8 July 1992
Resolved 8 July 1992
Navigation
Issued 30 June 1992 Resolved
PROVIDE CURRENT EDITION OF NAVIGATION CHARTS NO.12312 AND 12313FO CERTIFICATED OPERATING AREA.
Condition: Unknown
Due 8 July 1992
Resolved 8 July 1992
Engineering
Issued 27 April 1991 Resolved
REMOVE UNION JOINT IN FUEL LINE VENT WHERE FLAME SCREEN IS LOCATED AND MAKEAVAILABLE FOR CG INSPECTION.
Condition: Unknown
Due 18 September 1991
Resolved 18 September 1991
Documentation
Issued 27 April 1991 Resolved
PROVIDE AND ATTACH 1991 RENEWAL STICKER TO VESSELS DOCUMENTATION PAPERS.
Condition: Unknown
Due 18 September 1991
Resolved 18 September 1991
Navigation
Issued 27 April 1991 Resolved
INSTALL A 135 DEGREE STERN LIGHT FACING AFT LOCATED ON THE CENTER AXIS OF THE VESSEL.
Condition: Unknown
Due 18 September 1991
Resolved 18 September 1991
Construction/Loadline
Issued 27 April 1991 Resolved
ALL DECK HATCHES MUST HAVE A TENDING LINE ATTACHED
Condition: Unknown
Due 18 September 1991
Resolved 18 September 1991
Electrical
Issued 27 April 1991 Resolved
PROVIDE IN WRITING ALL TECNICAL DATA ON NEWLY INSTALLED ONAN 8.0 KW_x001C_ EMERG. GENERATOR MSO PHIADELPHIA INSPECTIONS DEPT.
Condition: Unknown
Due 18 September 1991
Resolved 18 September 1991
Lifesaving
Issued 3 May 1990 Resolved
PROVIDE 16 REPLACEMENT LIFE PRESERVERS.
Condition: Unknown
Due 3 May 1990
Resolved 3 May 1990
Electrical
Issued 3 May 1990 Resolved
REMOVE WIRE NUTS FROM ELECTRICAL BOX ON FORWARD BULKHEAD OF WOMENS HEAD AND PROPERLY SECURE COVER PLATE.
Condition: Unknown
Due 3 May 1990
Resolved 3 May 1990
Engineering
Issued 25 April 1989 Resolved
REMOVE OR CAP OFF SLUICE VALVE IN COLLISION SPACE BULKHEAD, AND AFTER STEERING SPACE BULKHEAD.
Condition: Unknown
Due 25 April 1989
Resolved 25 April 1989
Engineering
Issued 25 April 1989 Resolved
PROVIDE STRAINERS FOR ALL BILGE SYSTEM PICK UP'S WHERE MISSING.
Condition: Unknown
Due 25 April 1989
Resolved 25 April 1989
Accommodation/Occupational Safety
Issued 25 April 1989 Resolved
SECURE THE FLEXIBLE ENT FROM MSD TANK THROUGH HULL FITTING.
Condition: Unknown
Due 25 April 1989
Resolved 25 April 1989
Engineering
Issued 25 April 1989 Resolved
MARK OR STENCIL NAME OF COMPARTMENT ON MAIN BILGE VALVES, WHERE MISSING.
Condition: Unknown
Due 25 April 1989
Resolved 25 April 1989
Engineering
Issued 25 April 1989 Resolved
PROVIDE PROOF OR REPLACE ALL NON CG APPROVED FLEXIBLE FUEL LINE ON SERVICE GENERATOR, WITH CG APPROVED.
Condition: Unknown
Due 25 April 1989
Resolved 25 April 1989
Engineering
Issued 25 April 1989 Resolved
PROVIDE ONE (1) HEAT DEFLECTOR SHIELD FOR DAHL FUEL FILTER ON MDE WHERE MISSING.
Condition: Unknown
Due 25 April 1989
Resolved 25 April 1989
Lifesaving
Issued 25 April 1989 Resolved
PROVIDE ONE (1) ADULT PFD, WHERE TORN BEYOND REPAIR.
Condition: Unknown
Due 25 April 1989
Resolved 25 April 1989
Deck/Cargo
Issued 2 May 1988 Resolved
REMOVE ALL OIL AND OILY RESIDUE FROM ENGINE COMPARTMENT BILGES.
Condition: Unknown
Due 2 May 1988
Resolved 2 May 1988
Fire Fighting
Issued 2 May 1988 Resolved
PROVIDE SERVICING REPORT FOR ALL FIRE EXTINGUISHERS ON BOARD.
Condition: Unknown
Due 2 May 1988
Resolved 2 May 1988
Navigation
Issued 29 April 1986 Resolved
PROVIDE VALID RADIO TELEPHONE CERTIFICATE ON BOARD. VESSEL'S ROUTE IS RESTRICTED TO 1000 FEET FROM SHORE UNTIL THE CERTIFICATE IS ON BOARD THE VESSEL.
Condition: Unknown
Due 29 April 1986
Resolved 29 April 1986
Accommodation/Occupational Safety
Issued 21 June 1985 Resolved
RAISE SAFETY RAILS TO 42" AS REQUIRED BY 46 CFR 177.35-1(C).
Condition: Unknown
Due 21 June 1985
Resolved 21 June 1985

Casualty record · 4

18 August 2006Routine · role: Involved in a Marine Casualty · activity 2758228
22 August 2006Routine · role: Involved in a Marine Casualty · activity 2763953
28 August 2006Routine · role: Involved in a Marine Casualty · activity 2763807
15 February 2009Routine · role: Involved in a Marine Casualty · activity 3419609
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record