Records from 1996 to 2024. Most recent: inspection, 14 February 2024.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 13
14 February 2024
Type not recorded
No type recorded · USCGC IBIS (WPB 87338) · USCG Southeast District (CGD-SE) · Activity 7870865
18 April 2023
Type not recorded
No type recorded · Station Mayport · USCG Southeast District (CGD-SE) · Activity 7671359
10 February 2022
Type not recorded
No type recorded · USCGC POMPANO (WPB 87339) · USCG East District (CGD-E) · Activity 7397909
8 November 1999
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 802854
11 June 1999
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 808048
5 June 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 204827
5 June 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 767448
28 July 1998
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1430581
6 January 1998
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1120582
9 June 1997
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1110941
9 May 1997
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1101708
28 August 1996
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1431669
24 May 1996
Initial Construction-Excluding Oversight · Hull Examination · Initial Certification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1463257
Lifesaving
Issued 28 August 1996
Resolved
REMARK LIFE FLOAT WITH VESSEL'S NAME SO IT IS LEAGABLE
Condition: Unknown
Due 28 August 1996
Resolved 28 August 1996
Navigation
Issued 28 August 1996
Resolved
RELOCATE THE ALL AROUND ANCHOR LIGHT SO AS NOT TO BE VISUALLY OBSTRUCTED INA 360 DEGREE ARC.
Condition: Unknown
Due 28 August 1996
Resolved 28 August 1996
Lifesaving
Issued 28 August 1996
Resolved
PROVE PROPER OPERATION OF WATER LIGHT ATTACHED TO LIFE FLOAT.
Condition: Unknown
Due 28 August 1996
Resolved 28 August 1996
Engineering
Issued 28 August 1996
Resolved
DOUBLE LOCK ALL THROTTLE AND REDUCTION GEAR CABLE CONNECTIONS ON BOTH MAIN DESIEL ENGINES
Condition: Unknown
Due 28 August 1996
Resolved 28 August 1996
Engineering
Issued 28 August 1996
Resolved
PROPERLY GROUND ALL FUEL TANK FILL FITTINGS
Condition: Unknown
Due 28 August 1996
Resolved 28 August 1996
Fire Fighting
Issued 28 August 1996
Resolved
INSTALL PROPER MARINE BRACKETS FOR PORTABLE FIRE EXTINGUISHERS
Condition: Unknown
Due 17 September 1996
Resolved 17 September 1996
Construction/Loadline
Issued 28 August 1996
Resolved
PROVIDE WATER TIGHT HATCH COVER OVER ENGINE COMPARTMENT AS PER 46 CFR 171.124(a) & (b)
Condition: Unknown
Due 17 September 1996
Resolved 17 September 1996
Construction/Loadline
Issued 28 August 1996
Resolved
PROVIDE PROPER COWLING ON ENGINE COMPARTMENT VENTS SO TO INSURE THE LOWEST PART OF THE OPENING IS NOT LESS THAN 18 INCHES ABOVE THE MAIN DECK
Condition: Unknown
Due 17 September 1996
Resolved 17 September 1996
Navigation
Issued 28 August 1996
Resolved
DOUBLE LOCK ALL STEERING RODS AND HYDRAULIC RAM CONNECTIONS
Condition: Unknown
Due 28 August 1996
Resolved 28 August 1996
Construction/Loadline
Issued 28 August 1996
Resolved
PERMANENTLY INSTALL A MINIMUM 6 INCH COAMING AT THE ENTRANCE OF THE WEATHERTIGHT DOOR AT ENTRANCE OF THE MAIN CABIN AS PER 46 CFR 171.124(d)
Condition: Unknown
Due 5 September 1996
Resolved 28 August 1996
Construction/Loadline
Issued 28 August 1996
Resolved
PROVIDE ADEQUATE FREEING PORTS IN VESSEL'S WELLDECK AREA AS PER 46 CFR_x001C_ PART 171.150
Condition: Unknown
Due 17 September 1996
Resolved 17 September 1996
Unknown
Issued 24 May 1996
Resolved
PRIOR TO CARRYING PASSENGERS, NOTIFY THE COGNIZANT CG MARINE INSPECTION OFFICE.
Condition: Unknown
Due 24 May 1996
Resolved 24 May 1996
Navigation
Issued 24 May 1996
Resolved
PROVIDE CURRENT EDITIONS OF COAST PILOT, LIGHT LIST AND TIDE TABLES.
Condition: Unknown
Due 24 May 1996
Resolved 24 May 1996
Unknown
Issued 24 May 1996
Resolved
PROVIDE PROOF OF DRUG TESTING IN ACCORDANCE WITH 46 CFR PART 16.
Condition: Unknown
Due 24 May 1996
Resolved 24 May 1996