MAURY USCG vessel records
← All vessels

DENAK VOYAGER

DENAK VOYAGER is a 1996 freight ship. The Coast Guard has recorded 30 inspections since 2016, most recently in August 2023, along with 11 deficiencies and 8 operational controls.

Records from 2016 to 2023. Most recent: inspection, 17 August 2023.

Built
1996
Last inspected
17 August 2023
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 17 August 2023
…with no type recorded15
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9108257
438999
Flag
TURKEY
Maury page id
psix-438999

Documentation record

Tonnage as PSIX records it24167 - Simplified, Net Ton
37663 - Convention (Subpart B), Gross Ton
72171 - Dead Weight, Metric Ton
81690 - Displacement, Metric Ton
24167 - Convention (Subpart B), Net Ton
37663 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 30

17 August 2023 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7770320
11 January 2023 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7619066
31 May 2022 Ballast Water Examination · MARPOL Annex VI Survey · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7463812
18 October 2021 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7334604
5 May 2021 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7189733
9 October 2020 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7074444
27 April 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6944394
2 March 2020 PSC B · Ballast Water Examination · MARPOL Annex VI Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6918638
5 November 2019 PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6849330
13 July 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6749044
12 July 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6747436
22 May 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6690588
3 May 2019 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6675930
1 May 2019 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6675122
12 July 2018 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6476457
17 May 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6417136
15 May 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6415229
11 May 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6411979
4 November 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6300638
31 October 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6298258
26 October 2017 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6295687
14 September 2017 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6265931
11 September 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6264239
8 September 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6262430
24 May 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6154594
19 May 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6150098
1 February 2017 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6080791
28 November 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6048201
22 November 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6046061
2 August 2016 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5960595

Deficiency record · 11

11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 5 November 2019 Resolved
The liferaft container shall be marked with: .1 Makers name or trademark .2 Serial number .3 Name of apporving authority and number of persons it is permitted to carry .5 type of emergency pack enclosed The starboard side liferaft is missing required information on the placard. 74 SOLAS (1997) III/39.7.3 40AC
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 December 2019
Resolution: Recieved email with Class Survey
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 5 November 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship will remain fit to proceed to sea without danger to the ship or persons on board. Crew ran new cables in all electrical/pipe ducts penetrating A class bulkhead and did not insulate the cable runs to maintain the A class boundary. 74SOLAS (2014) I/11 (a) 40AC
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 December 2019
Resolution: recieved email with Class Survey
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 4 May 2019 Resolved
74 SOLAS (14) V/19.2.7.1 17ac ammended to 40ac ON ALL SHIPS 3,000 GROSS TONNAGE AND UPWARDS SHALL, IN ADDITION TO MEETING THE REQUIREMENTS OF PARAGRAPH 2.5, HAVE: A 3 GHz RADAR OR, WHERE CONSIDERED APPROPRITE BY THE ADMINISTRATION, A SECOND 9 GHz RADAR, OR OTHER MEANS, TO DETERMINE AND DISPLAY THE RANGE AND BEARING OF OTHER SURFACE CRAFT, OBSTRUCTIONS, BUOYS, SHORELINES AND NAVIGATIONAL MARKS TO ASSIST IN NAVIGATION AND IN COLLISION AVOIDANCE, WHICH ARE FUNCTIONALLY INDEPENDENT OF THOSE REFERRED TO IN PARAGRAPH 2.3.2. PSCO OBSERVED AN INOPERABLE 3 GHz (S-BAND) RADAR.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 May 2019
Resolution: Vessel sent in class report.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 3 May 2019 Resolved
EFFICIENT GUARD RAILS OR BULWARK SHALL BE FITTED TO ALL EXPOSED PARTS OF THE FREEBOARD AND SUPERSTRUCTURE DECKS. APPROXIMATELY 12 FEET OF GUARD RAILS WERE SEVERELY DAMAGED WHEN CHOCK WAS FRACTURED FROM A LOCATION ON FWD STBD FREEBOARD DECK DURING MANEUVERING OPERATIONS. ILLC I/25.2
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2019
Resolution: Received DNV GL classification society survey report stating with picture guard rails were replaced and renewed.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 3 May 2019 Resolved
AFTER ANY SURVEY OF THE SHIP HAS BEEN COMPLETED, NO CHANGE SHALL BE MADE IN THE STRUCTURAL ARRANGEMENTS, MACHINERY, EQUIPMENT, AND OTHER ITEMS COVERED BY THE SURVEY, WITHOUT THE SANCTION OF THE ADMINISTRATION. THERE WAS A MODIFIED CABLE PENETRATION THROUGH THE A-60 BULKHEAD BETWEEN THE ENGINE ROOM & STEERING GEAR ROOM, THAT DOES NOT MEET THE A-60 REQUIREMENTS. 74 SOLAS (14) I/11(b)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2019
Resolved 5 May 2019
Resolution: Received DNV GL classification society survey report stating with picture unused cable has been removed and cable penetration sealed with insert and found satisfacotry.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 3 May 2019 Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ABOARD. THE CHOCK WAS FRACTURED FROM ITS LOCATION ON FWD STBD FREEBOARD DECK DURING MANEUVERING OPERATIONS. 74 SOLAS (14) I/11(a)
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 May 2019
Resolution: Vessel sent in class report.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 May 2019 Resolved
ANY REQUIRED FIXED DETECTION AND FIRE ALARM SYSTEM SHALL BE CAPABLE OF IMMEDIATE OPERATION AT ALL TIMES. TWO HEAT DETECTORS IN ENGINEER WORKSHOP WERE INOPERABLE. 74 SOLAS (97) II-2/13.1.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 May 2019
Resolution: SHIP'S CREW REPLACED BOTH HEAT DETECTORS, AND WERE OP TESTED TO THE SATISFACTION OF THE ATTENDING USCG INSPECTORS.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 July 2018 Resolved
Fire extinguishing appliances shall be kept in good order and be available for immediate use at all times. 03 flexible CO2 hoses are severely damaged from chaffing, several other hoses showing signs of chaffing. 74 SOLAS (97 cons.) II-2/21
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 18 July 2018
Resolved 18 July 2018
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 12 July 2018 Resolved
All ships shall carry at least two fireman outfits complying with the requirements of paragraph 1. Vessel has only 01 operational fireman outfit. Large holes found in lower portions of 02 outfits. 74 SOLAS (97 cons.) II-2/17.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 July 2018
Resolved 18 July 2018
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 14 September 2017 Resolved
THE TESTING OF THE HEAT DETECTORS IS NOT CARRIED OUT IN ACCORDANCE WITH MANUFACTURERS RECOMMENDED PROCEDURES.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 15 September 2017
Resolved 26 October 2017
Resolution: Received class report with photos of detection testing equipment
Lifesaving › Lifeboat Equipment › Food Ration
Issued 14 September 2017 Resolved
11 FOOD RATIONS NOT CONTAINED IN AIRTIGHT PACKAGING.
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Due 15 September 2017
Resolved 18 September 2017
Resolution: Received invoice for 11 food rations

Ownership record