Records from 1985 to 2008. Most recent: inspection, 14 January 2008.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Electrical
Issued 21 August 1991
Resolved
MAKE NEC REPAIRS TO EMERGENCY DIESEL GEN. VOLTAGE REGULATOR AND PROVE PROPER OPERATION. STATEMENT FROM [name withheld] HAVE BEEN MADE, IS REQUIRED BEFORE VSL DEPARTS GIBRALTAR. REPAIRS TO BE INSP BY USCG UPON SHIPS ARRIVAL IN FIRST U.S. PORT
Condition: Unknown
Due 30 September 1991
Resolved 30 September 1991
Deck/Cargo
Issued 6 August 1991
Resolved
PROVIDE TO THE [name withheld] OF ALL ABS REPORTS ON TESTS/REPAIRS TO THE #4 STBD FWD CARGO BOOM. REFERENCE CASREP 021830Z AUG 91.
Condition: Unknown
Due 6 August 1991
Resolved 6 August 1991
Electrical
Issued 2 January 1991
Resolved
PROVIDE RECEPTACLE COVER TO ELECT RECEPTACLE APPROX CL OF FWD BHD OF HOUSE_x001C_AT MAIN DECK.
Condition: Unknown
Due 2 January 1991
Resolved 2 January 1991
Construction/Loadline
Issued 2 January 1991
Resolved
REMOVE SCALE AND TREAT STEAM LINES TO HEATING COILS AT ENTRY TO TANK TOPS _x001C_AFT OF WATERTIGHT DOOR GOING TO SHAFT ALLEY._x001C_
Condition: Unknown
Due 2 January 1991
Resolved 2 January 1991
Construction/Loadline
Issued 2 January 1991
Resolved
MAKE PERMANENT REPAIRS TO THE FOLLOWING PIPES TEMPORARILY REPAIRED:_x001C_ A]FATHOMETER WELL SUCTION PIPE AT ENTRY TO TANK TOP ER LWR LVL STBD._x001C_ B]ST LINE TO HTG COIL ENTRY TO TK TOP ER LWR LVL STBD AFT OF ER FWD BHD. C]ST LINE TO HTG COIL ENTRY TO TK TOP SHAFT ALLEY FOR #7S FO TK.
Condition: Unknown
Due 28 December 1991
Resolved 9 January 2002
Resolution: Administratively closed due to age of deficiencies.
Construction/Loadline
Issued 28 December 1990
Resolved
COMPLETE TWO PAGE, 18 ITEM WORKLIST TO THE SATISFACTION OF THE ATTENDING USCG MARINE INSPECTOR, PRIOR TO DEPARTING THE US ON INTERNATIONAL VOYAGES.
Condition: Unknown
Due 28 December 1990
Resolved 28 December 1990
Construction/Loadline
Issued 31 August 1988
Resolved
RENEWED FK6 KEEL PLATE. ORIGINAL THICKNESS .820 OR 33.4# PITTING AND CORROSION THROUGHOUT, BELOW ALLOWABLE TOLERANCES.
Condition: Unknown
Due 31 August 1988
Resolved 31 August 1988
Deck/Cargo
Issued 16 September 1987
Resolved
RENEW SCREENING AND REPAIR VENTILATION COVER FOR THE VENT RISER THAT IS LOCATED INBOARD OF THE NUMBER 14 CARGO WINCH.
Condition: Unknown
Due 16 September 1987
Resolved 16 September 1987
Construction/Loadline
Issued 16 September 1987
Resolved
THE STARBOARD AFTERMOST ROLLER CHOCK SUPPORT PADS ARE TO BE RENEWED WHERE WASTED.
Condition: Unknown
Due 16 September 1987
Resolved 16 September 1987
Fire Fighting
Issued 16 September 1987
Resolved
RENEW THE FASTENERS FOR ALL OF THE MAIN DECK FIRE MAIN FLANGE JOINTS.
Condition: Unknown
Due 16 September 1987
Resolved 16 September 1987
Deck/Cargo
Issued 16 September 1987
Resolved
REPAIR CABLE GUARDS WHERE WASTED ON ALL CARGO WINCH DRUM ASSEMBLIES.
Condition: Unknown
Due 16 September 1987
Resolved 16 September 1987
Construction/Loadline
Issued 16 September 1987
Resolved
RENEW SUPPORTS AND REPAIR THE HINGE ASSEMBLY AS NECESSARY TO THE FANTAIL ACCESS DOOR TO THE STEERING FLAT.
Condition: Unknown
Due 16 September 1987
Resolved 16 September 1987
Deck/Cargo
Issued 16 September 1987
Resolved
RENEW THE LINE BRACKETS FOR THE HYDRAULIC LINE CONFIGURATION THAT IS LOCATED UNDER THE #17/18 OPERATING PLATFORM.
Condition: Unknown
Due 16 September 1987
Resolved 16 September 1987
Deck/Cargo
Issued 16 September 1987
Resolved
RENEW THE MORSE CONTROL CONDUIT BRACKETS FOR THE VERTICAL RISER FOR WINCHES#17 & 18 AND ALSO RENEW OR REPLACE ASSOCIATED PROTECTION COVERS.
Condition: Unknown
Due 16 September 1987
Resolved 16 September 1987
Construction/Loadline
Issued 16 September 1987
Resolved
PROVIDE DOGGING IRONS FOR ALL MANUAL WEATHER AND WATERTIGHT DOOR ACCESSES WHERE MISSING.
Condition: Unknown
Due 16 September 1987
Resolved 16 September 1987
Lifesaving
Issued 16 September 1987
Resolved
UPDATE THE LIFEJACKET INSTRUCTION PLACARDS.
Condition: Unknown
Due 16 September 1987
Resolved 16 September 1987
Lifesaving
Issued 16 September 1987
Resolved
REBUILD ALL EXPOSED DECK LIFERING STATION BRACKETS WHERE BROKEN.
Condition: Unknown
Due 16 September 1987
Resolved 16 September 1987
Accommodation/Occupational Safety
Issued 16 September 1987
Resolved
RENEW WHERE WASTED THE FANTAIL CANOPY STANCHIONS OR REMOVE.
Condition: Unknown
Due 16 September 1987
Resolved 16 September 1987
Deck/Cargo
Issued 16 September 1987
Resolved
RENEW THE AFT SPARE ANCHOR SECURING BRACKETS AND FASTENERS.
Condition: Unknown
Due 16 September 1987
Resolved 16 September 1987
Construction/Loadline
Issued 16 September 1987
Resolved
REPAIR OR RENEW STRUCTURAL FRAMING MEMBERS IN WAY OF LADDER TO THE AFT PILOT STATION WHERE WASTED.
Condition: Unknown
Due 16 September 1987
Resolved 16 September 1987
Deck/Cargo
Issued 16 September 1987
Resolved
REBUILD WHERE WASTED THE CHOCK THAT IS LOCATED OUTBOARD OF THE #5 CARGO WINCH.
Condition: Unknown
Due 16 September 1987
Resolved 16 September 1987
Construction/Loadline
Issued 16 September 1987
Resolved
REBUILD THE GUARD RAILS ON THE CARGO OPERATORS CONTROL PLATFORM AT THE #7/8STATION.
Condition: Unknown
Due 16 September 1987
Resolved 16 September 1987
Deck/Cargo
Issued 16 September 1987
Resolved
REBUILD WHERE WASTED THE CHOCK THAT IS LOCATED OUTBOARD OF THE #13 CARGO WINCH.
Condition: Unknown
Due 16 September 1987
Resolved 16 September 1987
Deck/Cargo
Issued 16 September 1987
Resolved
REPAIR SUPPORT BRACKET FOR THE EXPANDED METAL SAFETY GUARD FOR THE #16 CARGO WINCH. SUPPORT BRACKET IS CRACKED IN THE AREA OF THE MAST JOINT.
Condition: Unknown
Due 16 September 1987
Resolved 16 September 1987
Construction/Loadline
Issued 16 September 1987
Resolved
RENEW WHERE WASTED THE SUPPORT STANCHION LOCATED ON THE MAIN DECK UNDER THE #11 CARGO WINCH.
Condition: Unknown
Due 16 September 1987
Resolved 16 September 1987
Construction/Loadline
Issued 16 September 1987
Resolved
REPAIR WHERE DAMAGED THE GUARD RAIL IN THE AREA OF THE #11 CARGO WINCH.
Condition: Unknown
Due 16 September 1987
Resolved 16 September 1987
Construction/Loadline
Issued 16 September 1987
Resolved
REBUILD THE CARGO WINCH OPERATING CONTROL PLATFORMS FOR THE TOP WINCH STATIONS #1/3 AND 2/4.
Condition: Unknown
Due 16 September 1987
Resolved 16 September 1987
Unknown
Issued 29 October 1986
Resolved
TEST THE FORWARD MOST AND AFTER MOST FIREMAIN RELIEF VALVES ON THE OPEN DECKS.
Condition: Unknown
Due 29 October 1986
Resolved 29 October 1986
Construction/Loadline
Issued 29 October 1986
Resolved
PROVIDE REPAIRS TO THE WASTED CONNECTION WELDMENT AT THE STBD SIDE FORWARDMOST BULWARK STAY WHERE IT JOINS TO THE BOW FASHION PLATE (OUTBOARD OF THE #1 CARGO HATCH).
Condition: Unknown
Due 29 October 1986
Resolved 29 October 1986
Accommodation/Occupational Safety
Issued 29 October 1986
Resolved
REPAIR OR RENEW WHERE WASTED THE EXPOSED CARGO DECK AND SUPERSTRUCTURE DECK(S) LADDERS.
Condition: Unknown
Due 29 October 1986
Resolved 29 October 1986
Lifesaving
Issued 29 October 1986
Resolved
RENEW THE WASTED TIE-IN BRACKET ON THE STBD AFT BOAT DAVITS WHERE THE DAVITTRACK MEETS THE EMBARKATION DECK.
Condition: Unknown
Due 29 October 1986
Resolved 29 October 1986
Lifesaving
Issued 29 October 1986
Resolved
RENEW THE STBD SIDE AFTERMOST LIFEBOAT EMBARKATION DECK LIGHTS SUPPORTING MEMBER.
Condition: Unknown
Due 29 October 1986
Resolved 29 October 1986
Construction/Loadline
Issued 3 October 1986
Resolved
SERVICE CARGO HATCH COVER DOGS AND RENEW ALL WASTED COMPRESSION SPACERS. ITEM MUST BE COMPLETED PRIOR TO RECERTIFICATION.
Condition: Unknown
Due 3 October 1986
Resolved 3 October 1986
Engineering
Issued 3 October 1986
Resolved
PROVE OPERATION OF OIL WATER SEPARATOR PRIOR TO REACTIVATION OF VESSEL AND REISSUANCE OF THE IOPP CERTIFICATE.
Condition: Unknown
Due 3 October 1986
Resolved 3 October 1986
Accommodation/Occupational Safety
Issued 21 August 1985
Resolved
INSURE ESCAPE IN SHAFT ALLEY IS MARKED FOR EASY LOCATION AND IS FREE OF ALLOBSTRUCTIONS.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Engineering
Issued 21 August 1985
Resolved
CONDUCT HYDROSTATIC TEST OF ALL BOILERS.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Electrical
Issued 21 August 1985
Resolved
RELAMP, REPAIR OR REPLACE AS REQUIRED ALL ELECTRICAL FIXTURES, ALL FIXTURESSHALL BE REPAIRED OR REPLACED, INCLUDING OVERHEAD LIGHTING, NAVIGATION LIGHTS AND ALARMS, MOTOR CONTROLLERS AND ALL OTHER ALARMS.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Lifesaving
Issued 21 August 1985
Resolved
REPLACE BROKEN WHEEL ON AFT DAVIT LIMIT SWITCH FOR STBD LIFEBOAT.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Engineering
Issued 21 August 1985
Resolved
CONDUCT HYDROSTATIC TEST OF THE WHISTLE AIR RECEIVER.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Deck/Cargo
Issued 21 August 1985
Resolved
PROVIDE PROPER FLAME SCREENS ON ALL FUEL OIL VENTS.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Engineering
Issued 21 August 1985
Resolved
REMOVE ALL DRYING MATERIAL FROM BOTTOM OF BOILER FURNANCES AND INSPECT FLOOR OF ALL CHAMBERS.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Electrical
Issued 21 August 1985
Resolved
RELAMP AND PROVIDE GLOBES AND GUARDS FOR ALL DECK LIGHTS AS NECESSARY.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Accommodation/Occupational Safety
Issued 21 August 1985
Resolved
TEST PORTABLE WATER TANK PUMPS AND OBSERVE PIPING.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Electrical
Issued 21 August 1985
Resolved
REPAIR INOPERATIVE GENERAL ALARM BELLS LOCATED - (1) SHAFT ALLEY FWD BELL; (2) HOUSE MAIN DECK, PORTSIDE PASSAGEWAY, AFT BELL.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Engineering
Issued 21 August 1985
Resolved
REWIRE ALL STEAM DRUM LEVEL GAUGE LIGHTS.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Accommodation/Occupational Safety
Issued 21 August 1985
Resolved
TEST SANITARY WATER PUMPS AND OBSERVE PIPING.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Engineering
Issued 21 August 1985
Resolved
REPLACE ALL MOTOR GUARDS UPON RE-COUPLING ALL MOTORS TO THEIR RESPECTIVE LOADS.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Electrical
Issued 21 August 1985
Resolved
TEST GROUND DETECTORS ON MAIN AND EMERGENCY GENERATOR SWITCHBOARDS.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Engineering
Issued 21 August 1985
Resolved
TEST OPERATION OF LUBE OIL PUMPS AND OBSERVE PIPING.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Navigation
Issued 21 August 1985
Resolved
PROVIDE AND POST MANEUVERING CHARACTERISTICS ON THE BRIDGE.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Electrical
Issued 21 August 1985
Resolved
REPLACE CABLE CLAMPS ON CABLE THAT IS FEEDER TO WELDER OUTSIDE CO2 ROOM.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Electrical
Issued 21 August 1985
Resolved
MARK ALL EMERGENCY LIGHTING WITH "E".
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Engineering
Issued 21 August 1985
Resolved
MAKE PERMANENT REPAIRS TO STARBOARD SEA CHEST STEAMING OUT LINE.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Fire Fighting
Issued 21 August 1985
Resolved
LABEL SAND BOX AND REPLACE MISSING SAND AND SCOOP.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Electrical
Issued 21 August 1985
Resolved
REPAIR OR REPLACE STARBOARD DECK SEARCHLIGHT.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Engineering
Issued 21 August 1985
Resolved
PROVE OPERATION OF EVEPORATORS.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Engineering
Issued 21 August 1985
Resolved
DEMONSTRATE OPERATION OF COMPRESSED AIR SYSTEM.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Engineering
Issued 21 August 1985
Resolved
RENEW STBD SUPER HEATER SAFETY NOZZLE PIECE. EXISTING NOZZLE HAS AN UNACCEPTABLE WELD.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Engineering
Issued 21 August 1985
Resolved
CONDUCT HYDROSTATIC TEST OF CONTAMINATED EVAPARATOR TUBE SIDE, SHIP SERVICEAIR RECEIVER AND BOILER COMPOUND TANK.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Accommodation/Occupational Safety
Issued 21 August 1985
Resolved
RENEW WASTED HANDRAIL STANCHION ON 02 DECK ADJACENT TO STBD LIFEBOAT.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Accommodation/Occupational Safety
Issued 21 August 1985
Resolved
RENEW WASTED STANCHION ON STBD LIFEBOAT MAINTENANCE CATWALK.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Lifesaving
Issued 21 August 1985
Resolved
PROVIDE, MARK AND STOW ALL REQUIRED LIFESAVING EQUIPMENT INCLUDING LIFEBOATPROVISIONS, LIFERAFTS, LIFE PRESERVERS, RING BOUYS, LINE THROWING APPLIANCE, EPIRB, LIFEBOAT RADIO, AND EXPOSURE SUITS.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Fire Fighting
Issued 21 August 1985
Resolved
PROVIDE, MARK, SERVICE AND TEST REQUIRED FIREFIGHTING EQUIPMENT INCLUDING FIXED, SEMI-PORTABLE, AND PORTABLE EXTINGUISHING SYSTEMS; SMOKE DETECTION SYSTEMS; FIRE MAIN; FIRE HOSES, NOZZLES, AND APPLICATORS.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Navigation
Issued 21 August 1985
Resolved
PROVIDE INTERNATIONAL SIGNAL FLAGS.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Lifesaving
Issued 21 August 1985
Resolved
PROVIDE AN APPROVED PILOT LADDER.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Construction/Loadline
Issued 21 August 1985
Resolved
REPAIR GUARD RAILS AND STANCHIONS WHERE DETERIORATED.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Construction/Loadline
Issued 21 August 1985
Resolved
DEMONSTRATE SATISFACTORY OPERATION OF ANCHOR WINDLASSES, WARPING CAPSTANS AND WINCHES.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Engineering
Issued 21 August 1985
Resolved
TEST OPERATION OF MAIN PROPULSION DEVICES AND CONTROLS.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Engineering
Issued 21 August 1985
Resolved
SET AND SEAL PORT AND STARBOARD BOILER STEAM DRUM AND SUPERHEATER SAFETY VALVES.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Documentation
Issued 21 August 1985
Resolved
PROVIDE ALL REQUIRED CERTIFICATES INCLUDING FCC CERTIFICATE FOR RADIO INSTALLATIONS, RADARS, AND EPIRB; CARGO GEAR CERTIFICATE; CERTIFICATE OF FINANCIAL RESPONSIBILITY; INTERNATIONAL CERTIFICATES.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Deck/Cargo
Issued 21 August 1985
Resolved
PROVIDE ADEQUATE PORTABLE CONTAINMENT FOR ALL FUEL OIL VENTS.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Construction/Loadline
Issued 21 August 1985
Resolved
TEST OPERATION OF ALL WATERTIGHT DOORS.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Fire Fighting
Issued 21 August 1985
Resolved
TEST ALL FIRE PUMPS AND THE RELIEF VALVES.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Construction/Loadline
Issued 21 August 1985
Resolved
TEST REMOTE SHUT DOWNS FOR ENGINE ROOM, CARGO SPACE AND ACCOMMODATION SPACE VENTILATION.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Navigation
Issued 21 August 1985
Resolved
TEST ENGINE ORDER TELEGRAPH AND ITS FAILURE ALARM.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Lifesaving
Issued 21 August 1985
Resolved
LOWER AND RAISE ALL LIFEBOATS, CHECK MASTER AND LIMIT SWITCHES.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Electrical
Issued 21 August 1985
Resolved
TEST OPERATION OF EMERGENCY LIGHTS, EMERGENCY POWER AND BATTERIES.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Electrical
Issued 21 August 1985
Resolved
TEST OPERATIONALLY SHIPS SERVICE AND EMERGENCY GENERATORS AND ALL GENERATOR SAFETY DEVICES. (TO INCLUDE OVERSPEED TRIPS, LOW LUBE OIL PRESSURE ALARM AND LOW LUBE OIL PRESSURE TRIPS AND REVERSE CURRENT RELAYS).
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Electrical
Issued 21 August 1985
Resolved
REPLACE CARGO REEFER BOX #4 AND #5 GAUGES.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Engineering
Issued 21 August 1985
Resolved
RENEW LENS PORT ON CONTAMINATED HOLDING TANK.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Electrical
Issued 21 August 1985
Resolved
REWIRE LAMPS FOR SMOKE INDICATORS.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Lifesaving
Issued 21 August 1985
Resolved
PROVIDE ALL HOSPITAL AND FIRST AID EQUIPMENT.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Engineering
Issued 21 August 1985
Resolved
CALIBRATE, REPAIR OR REPLACE AS REQUIRED ALL PRESSURE GAUGES AND TEMPERATURE INDICATORS.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Navigation
Issued 21 August 1985
Resolved
RELAMP AND TEST ALL NAVAGATIONAL LIGHTS. ENSURE LIGHTS ARE IN ACCORDANCE WITH STANDARDS PRESCRIBED BY CURRENT INTERNATIONAL RULES OF THE ROAD.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Lifesaving
Issued 21 August 1985
Resolved
CONDUCT WEIGHT TEST OF LIFEBOATS AND LIFEBOAT DAVITS. CONDUCT OPERATIONAL TEST OF ALL LIFEBOATS.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Lifesaving
Issued 21 August 1985
Resolved
CONDUCT FIRE AND LIFEBOAT DRILLS IN THE PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Navigation
Issued 21 August 1985
Resolved
PROVIDE INTERNATIONAL DAYSHAPES AS REQUIRED BY THE INTERNATIONAL RULES OF THE ROAD.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Documentation
Issued 21 August 1985
Resolved
PROVIDE UP TO DATE OIL TRANSFER PROCEDURES AND DESIGNATION OF PERSON IN CHARGE.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Fire Fighting
Issued 21 August 1985
Resolved
MAKE ALL REQUIRED FIRE HOSES AVAILABLE FOR HYDROSTATIC TEST.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Lifesaving
Issued 21 August 1985
Resolved
DEMONSTRATE THE OPERATION OF THE #2 LIFEBOAT BILGE PUMP.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Lifesaving
Issued 21 August 1985
Resolved
REPLACE WASTED DAVIT ARM STOP ALINGMENT PIN ON FWD DAVIT FOR STBD LIFEBOAT.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Electrical
Issued 21 August 1985
Resolved
REPAIR INOPERATIVE SOUND POWERED TELEPHONE LOCATED ON THE FOSCLE.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Construction/Loadline
Issued 21 August 1985
Resolved
INSPECT AND TEST THE HULL AND DECK FITTINGS INCLUDING VALVES AND CONTROLS, BILGE WELLS AND SUCTIONS, DECK OPENINGS AND CLOSURES, WATERTIGHT DOORS, AND CARGO GEAR.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Accommodation/Occupational Safety
Issued 21 August 1985
Resolved
INSPECT AND TEST ALL REMOTE CONTROLS TO POWER VENTILATION AND MECHANICAL VENT CLOSURES.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Navigation
Issued 21 August 1985
Resolved
PROVIDE UP TO DATE CHARTS AND NAVAGATIONAL PUBLICATIONS.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Lifesaving
Issued 21 August 1985
Resolved
INSTALL DAVIT SPAN WIRES WITH MAN ROPES BETWEEN LIFEBOAT DAVITS.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Lifesaving
Issued 21 August 1985
Resolved
INSTALL TRICING LINE WITH PELICAN HOOK ON ALL LIFEBOAT DAVITS.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Accommodation/Occupational Safety
Issued 21 August 1985
Resolved
OPERATE GALLEY DUMB WAITERS AND CHECK SAFETY SWITCHES.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Navigation
Issued 21 August 1985
Resolved
TEST STEERING SYSTEM FOR OPERATION, RELIEF VALVE AND STEERING FAILURE ALARM.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Accommodation/Occupational Safety
Issued 21 August 1985
Resolved
PROVE OPERATION OF MARINE SANITATION DEVICE.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Deck/Cargo
Issued 21 August 1985
Resolved
MAKE OPERABLE ALL CARGO REEFER BOX INSIDE SAFETY LATCHES AND EMERGENCY ESCAPE HATCHES.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Electrical
Issued 21 August 1985
Resolved
REMOVE OR DEADEND SEVERED ELECTRICAL CABLES IN ALL CARGO WINCH CONTROL STATIONS.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Documentation
Issued 21 August 1985
Resolved
PROVIDE AND POST ALL REQUIRED FORMS, NOTICES, AND PUBLICATIONS.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Navigation
Issued 21 August 1985
Resolved
PROVIDE AND TEST ALL NAVIGATIONAL EQUIPMENT REQUIRED BY 33 CFR 164.35.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Lifesaving
Issued 21 August 1985
Resolved
PROVIDE THE REQUIRED PYROTECNIQUE DISTRESS SIGNALS.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Deck/Cargo
Issued 21 August 1985
Resolved
TEST REEFER BOX ALARMS.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Accommodation/Occupational Safety
Issued 21 August 1985
Resolved
OPERATE AIR CONDITIONING AND REFRIGERATION SYSTEM.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Engineering
Issued 21 August 1985
Resolved
RE-CONNECT SPOOL PIECES TO OVERBOARD DISCHARGE LINES ON FORE AND AFT EDUCTORS AND DEMONSTRATE THEIR USE.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Engineering
Issued 21 August 1985
Resolved
TEST AND OPERATE ALL LOCAL AND REMOTE SWITCHES FOR BILGE PUMPS AND THE OPERATION OF ALL BILGE PUMPS ALONG WITH ITS ASSOCIATED PIPING AND EQUIPMENT.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Engineering
Issued 21 August 1985
Resolved
TEST ALL PRESSURE VESSEL SAFETY RELIEF VALVES.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Engineering
Issued 21 August 1985
Resolved
OPERATE FEED WATER PUMPS, OBSERVE ALL PIPING, AND RELATED EQUIPMENT.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Engineering
Issued 21 August 1985
Resolved
TEST FUEL OIL TRANSFER AND SERVICE PUMPS UNDER NORMAL OPERATING PRESSURE, REMOTE SHUTDOWNS, AND OBSERVE ALL RELATED PIPING AND ASSOCIATED EQUIPMENT.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Engineering
Issued 21 August 1985
Resolved
CONDUCT HYDROSTATIC TEST ON ALL PIPING SUBJECT TO BOILER PRESSURE.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Engineering
Issued 21 August 1985
Resolved
TEST FORCE DRAFT BLOWERS.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Engineering
Issued 21 August 1985
Resolved
TEST ALL SOOT BLOWERS.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Electrical
Issued 21 August 1985
Resolved
TEST THE GENERAL ALARM SYSTEM.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Fire Fighting
Issued 21 August 1985
Resolved
PROVIDE, MARK, AND STOW TWO FIREMAN'S OUTFITS AND AN INTERNATIONAL SHORE CONNECTION.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Engineering
Issued 21 August 1985
Resolved
EXAMINE ALL HYDRAULIC SYSTEMS AND REPAIR ALL LEAKS INCLUDING SYSTEMS FOR STEERING, WATERTIGHT DOORS, AND CARGO HATCH SYSTEMS.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985
Navigation
Issued 21 August 1985
Resolved
REPAIR MOUTH PIECES AND/OR WHISTLES IN BRIDGE.
Condition: Unknown
Due 21 August 1985
Resolved 21 August 1985