MAURY USCG vessel records Sign in
← All vessels

UGLY ANNE II

UGLY ANNE II is a 1960 passenger vessel (inspected). The Coast Guard has recorded 60 inspections since 1985, most recently in June 2026, along with 111 deficiencies and 1 casualty investigation in 2025.

Records from 1985 to 2026. Most recent: inspection, 26 June 2026.

Built
1960
Last inspected
26 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDP5646
Flag
UNITED STATES
367303330
Maury page id
psix-43908

Inspections, by type

…with no type recorded5
Years with a record 36 calendar years (1985–2026)
The 60 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)63.7 ft × 15.3 ft × 4.8 ft
Registered tonnagegross 14 / net 9
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJ.W. NOLAN & SONS INC · ERIE, PA, UNITED STATES · built 1960
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMACKINAW CITY, MI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 25 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Regulatory (Subpart C or D), Gross Ton
9 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP5646MMSI 367303330 · active · compulsorily equipped · granted 1 May 2024, expires 1 May 2034
WDD8832MMSI 367303330 · cancelled · compulsorily equipped · granted 16 May 2017, cancelled 8 April 2024 · licensed under a name not among this hull’s recorded names (not shown)
WTE8327MMSI not assigned · expired · compulsorily equipped · granted 24 April 1998, cancelled 28 June 2008 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 60

26 June 2026 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8430777
6 August 2025 Administrative Inspection · In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8203914
5 August 2025 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8203996
13 June 2025 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8163005
2 April 2024 Administrative Inspection · Annual Inspection · In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7906057
15 February 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7867398
28 April 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7668621
28 April 2022 Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7440218
22 April 2022 COI Inspection · Administrative Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7434177
28 April 2021 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7185017
6 April 2021 Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7169728
20 May 2020 Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6956371
15 October 2019 Internal Structural Exam · Drydock Exam
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6834407
17 April 2019 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6663370
18 April 2018 Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6393133
10 April 2017 COI Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6116885
9 October 2015 Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5739361
25 September 2015 Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5727343
3 October 2014 Drydock Exam
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 4998097
22 October 2010 DAPI Audit
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 3879167
21 September 2010 Re-Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 3853280
17 July 2008 Re-Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 3190454
28 February 2007 COI Inspection · Plan Review "T" Boat · Hull Examination · Internal Structural Exam
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2879951
16 June 2006 Annual Inspection
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2681323
22 April 2005 COI Inspection
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2333570
24 August 2004 Deficiency Check
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2174852
14 July 2004 Annual Inspection
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2133156
9 June 2003 Hull Examination
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 1847085
20 May 2003 Drydock Extension · Re-Inspection
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 1797699
22 May 2001 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1426620
27 April 2000 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1473487
15 July 1999 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1120185
17 May 1999 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1381581
16 September 1998 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 798789
3 June 1998 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1400821
8 May 1998 Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1392930
22 May 1997 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1457460
5 May 1997 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1454445
25 October 1996 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1163289
27 August 1996 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1084524
11 July 1996 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1086859
29 May 1996 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1421137
1 November 1995 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 880450
20 September 1995 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1184754
28 June 1995 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1409308
4 May 1994 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1423944
9 June 1993 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 845087
12 May 1993 Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 839694
19 May 1992 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1261654
7 September 1991 Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 942415
10 May 1991 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 942416
26 June 1990 Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1211723
2 May 1990 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 929603
8 May 1989 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1343016
12 August 1988 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1346941
15 July 1988 Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 899016
26 May 1988 Hull Examination · COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 887633
8 May 1987 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1014382
21 June 1986 Re-Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1301158
13 May 1985 Type not recorded
No type recorded · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 979476

Deficiency record · 111

09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 28 April 2023 Resolved
A vessel must carry a first aid kit approved under 160.041. Found expired aspirin. Replace.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2023
Resolved 22 August 2023
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 28 April 2023 Resolved
VHF radio displays "Low Battery". Determine the backup power to repair/replace to meet requirements.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2023
Resolved 22 August 2023
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 28 April 2023 Resolved
At each inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil. Found exscess oil accumulation within the bilges. Clean all oil from bilges.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2023
Resolved 13 September 2023
Resolution: Provided proof of clean bilges
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 28 April 2023 Resolved
The name of the vessel must be marked and number of persons capacity must be markedon each lifefloat. Vessel name and persons capacity are faded on both lifefloats.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2023
Resolved 13 September 2023
Resolution: Pax counts stenciled on raft
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 April 2023 Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protectedby a cover, guard, or rail. Pulleys on the generator and main engine are exposed. Cover. Operator to procure custom fabrication of guard. To be cleared at next annual.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 May 2023
Resolved 20 June 2024
Resolution: corrected
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 22 April 2022 Resolved
The power fire pump shall be self-priming and of such size as to discharge an effective stream from a hose connected to the highest outlet. Fire pump had a cracked housing and was actively leaking. Fire pump to be replaced. Code: 60c **Update** Accepted as temporary repair. Vessel required to have 3 fire buckets on board in addition. Upon receipt of purchase order, will determine due date. Changed code to 705c CITE 46 CFR 181.10-1(b)
Action required: 705 - Other - as specified
Resolved 15 February 2024
Resolution: New fire pump installed.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 22 April 2022 Resolved
The painter must: Be of at least 100 ft in length, but not less than 3 times the distance between the deck where buoyant apparatus is stowed and the lowest load waterline; Have a breaking strength of at least 1,500lbs; Be of a dark color if synthetic, or of a type certified to be resistant to deterioration from UV light; Be stowed in such a way that it runs out freely when the buoyant apparatus floats away from a sinking vessel. Painter for buoyant apparatus was sun damaged and frayed. Replace painter. CITE 46 CFR 180.175(f)(3)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 May 2022
Resolution: Painter replaced.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 22 April 2022 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Alcohol testing devices are set to expire 30APR2022 with no replacements. Replace alcohol testing swabs. CITE 46 CFR 185.212 46 CFR 4.06-15(a)(1)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 May 2022
Resolution: Obatined new alcohol testing swabs.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 22 April 2022 Resolved
At each inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil. Found excessive oil accumulation within bilges. Clean all oil from bilges. CITE 46 CFR 176.830(b)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 May 2022
Resolution: Bilges cleaned.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 April 2022 Resolved
At each inspection, the owner or managing operator shall be prepared to conduct test and have vessel ready for inspection of machinery, fuel, and piping systems including: operational test of the means provided for pumping bilges. During test of bilge system, operator was unsure of which valves to open/close, which resulted in a discharge of oily bilge-water mix. Retest bilge system. CITE 46 CFR 176.804(h)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 May 2022
Resolution: Tested bilge system.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 April 2022 Resolved
Each ring life buoy on a vessel must: be approved in accordance with 160.050 of this chapter. Grab line on ring buoy was frayed and sun damaged. Replace grab line. CITE 46 CFR 180.70(b)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2022
Resolved 6 May 2022
Resolution: Replaced grab line.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 April 2022 Resolved
Each life jacket must be marked in clearly legible block capital letters with the vessel's name. The vessel's name on multiple adult life jackets was faded. Remark life jackets. CITE 46 CFR 185.604(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2022
Resolved 6 May 2022
Resolution: Marked life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 April 2022 Resolved
Each life jacket must be marked with Type I retro-reflective material. The arrangement of the retro-reflective material applied must be as specified by IMO Resolution A.658(16). Retro-reflective tape on both child and adult life jackets were worn, missing and/or not reflective. Replace retro-reflective tape. CITE 46 CFR 185.604(h)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2022
Resolved 6 May 2022
Resolution: Replaced retro-reflective tape.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 April 2022 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel missing (01) adult life jacket. Vessel restricted to 74 persons on board until new life jacket is obtained. CITE 46 CFR 180.71(a)
Action required: 705 - Other - as specified
Resolved 15 February 2024
Resolution: 01 lifejacket provided.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 April 2022 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents. Several items (iodine) within first-aid kit were expired. Replace items. CITE 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2022
Resolved 6 May 2022
Resolution: Replaced first-aid kit items.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 April 2022 Resolved
Bilge pipe piercing the collision bulkhead shall be fitted with a screw-down valve located on the forward side of the collision bulkhead and operable from above the weather deck. In lieu thereof, a crew-down valve without a reach rod may be fitted to the bilge line on the after side of the collision bulkhead if it is readily accessible under service conditions. Vessel was found with no screw-down valve for the bilge pipe that pierces the collision bulkhead. Install screw-down valve that can either be operable from the weather deck or on the aft side of the bulkhead. CITE 46 CFR 182.25-5(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2022
Resolved 6 May 2022
Resolution: Installed screw-down valve on aft side of collision bulkhead
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 April 2022 Resolved
At each inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Hazardous and flammable items were stowed out in the open of the engine room. Hazardous/flammable stores to be removed from the engine room and stowed properly. CITE 46 CFR 176.830(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2022
Resolved 6 May 2022
Resolution: Removed items from engine room.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 April 2022 Resolved
Batteries shall be effectively screened by a cage or similar structure to minimize the danger of accidental park through dropping a metal object across the terminals. Batteries in engine room did not have a cover to protect terminals. Install cover. CITE 46 CFR 183.05-20(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2022
Resolved 6 May 2022
Resolution: Installed battery covers
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 April 2022 Resolved
Battery terminals shall be of the soldered type and all connections shall be made to the battery terminals with permanent type connectors. Battery in engine room had wing nuts on post. Remove wing nuts and replace with proper connector. CITE 46 CFR 183.05-20(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2022
Resolved 6 May 2022
Resolution: Removed wing nuts and installed proper connectors.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 22 April 2022 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible. Vessel's charts were had not been updated. Update charts. CITE 46 CFR 184.420(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2022
Resolved 6 May 2022
Resolution: Updated charts.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 22 April 2022 Resolved
Vessel must be fitted with a suitable magnetic compass designed for marine use. Vessel's magnetic compass did not have a deviation card. Obtain deviation card. CITE 46 CFR 184.402(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2022
Resolved 15 February 2024
Resolution: Deviation card provided.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 22 April 2022 Resolved
Drills and training shall be logged. Entry shall include the following information: Date of drill and training. Missing year on dates within logbooks. Ensure logging of year on dates. CITE 46 CFR 185.524(d)(1) 46 CFR 185.520(f)(1)
Action required: 10 - Deficiency Rectified
Resolved 22 April 2022
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 22 April 2022 Resolved
No marine employer shall engage or employ any individual to serve as a crew member unless the individual passes a chemical test for dangerous drugs for that employer. Vessel operated during the 2021 season with multiple different people that served as a deckhand and were not chemical tested. Vessel to operate only with crew members that have completed a chemical test. CITE 46 CFR 16.210(a)
Action required: 10 - Deficiency Rectified
Resolved 22 April 2022
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 22 April 2022 Resolved
Employers must maintain records of chemical tests as provided in 49 CFR 40.333 and must make these records available to Coast Guard officials upon request. Requested records for deckhands used during 2021 season that were not a part of the third party consortium that the marine employer used for crew. Marine employer did not have records for deckhands as they were not tested nor enrolled in another third party consortium. Marine employer to maintain records of chemical tests for all employees. CITE 46 CFR 16.260
Action required: 10 - Deficiency Rectified
Resolved 22 April 2022
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 22 April 2022 Resolved
Inspection and maintenance of the survival craft shall be logged or otherwise documented for review by the Coast Guard upon request. EPIRB test required shall be logged or otherwise documented. Monthly safety checks were not logged. Log monthly safety checks. CITE 46 CFR 185.702(d) 46 CFR 185.728(c)
Action required: 10 - Deficiency Rectified
Resolved 22 April 2022
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 22 April 2022 Resolved
Each survival craft on a vessel must be inspected monthly, using the manufacturer's instructions to make sure it is complete and in good order. Each EPIRB must be tested monthly. Monthly checks were not completed. Complete monthly checks. CITE 46 CFR 185.722 46 CFR 185.728(a)
Action required: 10 - Deficiency Rectified
Resolved 22 April 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 22 April 2022 Resolved
A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection (COI). Vessel's COI expired on 10 APR 2022. Completed COI Renewal on 22 APR 2022. CITE 46 CFR 176.100(a)
Action required: 10 - Deficiency Rectified
Resolved 22 April 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 April 2022 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. Vessel completed unauthorized repairs to the fire pump. Vessel to complete repairs only with approval from cognizant [name withheld] 46 CFR 176.700(a)
Action required: 10 - Deficiency Rectified
Resolved 22 April 2022
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Procedure for inspection, reporting and correcting unsafe conditions and for investigating a
Issued 22 April 2022 Resolved
Immediately after the addressing of resultant safety concerns, the owner, agent, master, or person in charge of a vessel involved in a marine casualty shall notify the nearest Sector Office, Marine Inspection Office whenever a vessel is involved in a marine casualty consisting of: An occurrence materially and adversely affecting the vessel's seaworthiness or fitness for service or route. Vessel did not report issue with fire pump to Coast Guard. Vessel to report all marine casualties to Coast Guard. CITE 46 CFR 185.202(a)(4)
Action required: 10 - Deficiency Rectified
Resolved 22 April 2022
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 28 April 2021 Resolved
Provide proof of enrollment in random drug testing program.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 1 June 2021
Resolution: Email verification received from vessel owner/captain.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 28 April 2021 Resolved
Update coast pilot, light list and electronic charts.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 1 June 2021
Resolution: Email verification received from vessel owner/captain.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 28 April 2021 Resolved
Develop a waste management plan.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 1 June 2021
Resolution: Email verification received from vessel owner/captain.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 28 April 2021 Resolved
Repair mast headlight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 23 July 2021
Resolution: Verified installation and operation
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 28 April 2021 Resolved
Provide first adi kit in a watertight container with instructions and required content.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 1 June 2021
Resolution: Email verification received from vessel owner/captain.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 28 April 2021 Resolved
Renew batteries in engine room flashlight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2021
Resolved 30 July 2021
Resolution: Batteries renewed.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 28 April 2021 Resolved
Renew hydrostatic release for EPIRB. Vessel is limited to 3NM from shore until renewed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 July 2021
Resolution: Verified proper installation and marking of hydrostatic release.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 28 April 2021 Resolved
Replace light for lifefloat.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 June 2021
Resolution: Email verification received from vessel owner/captain.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 April 2021 Resolved
Provide lights for PFD's. Route is limited to less than 20NM from harbor of safe refuge until provided. Update: owner does not want to purchase lights, but wants to keep route for greater than 20nm from harbor of safe refuge even though he is not operating as such now. Will revisit at next annual to restrict the route, amend the COI, or include a statement to say if the vessel operates greater than 20nm from HSR, then lights are needed IAW 46 CFR 180.75
Action required: 705 - Other - as specified
Resolved 16 May 2022
Resolution: Amended COI
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 April 2021 Resolved
Replace battery in floating waterlight on ring lifebuoy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 July 2021
Resolution: Verified new batteries were placed into service on the waterlights for the lifering and life floats.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 April 2021 Resolved
Provide new labels for fuel shut off and life jacket stowage.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 June 2021
Resolution: Email verification received from vessel owner/captain.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 28 April 2021 Resolved
Replace flame screen on port fuel vent.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 23 July 2021
Resolution: New flame screens have been installed on the fuel vent by glue. Vent arrangement is such that the gooseneck cap can be unscrewed for easy removal and cleanout.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 April 2021 Resolved
Replace fire nozzle to corrosion resistant and capable of changing between a solid stream and a spray pattern.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 June 2021
Resolution: Email verification received from vessel owner/captain.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 28 April 2021 Resolved
Replace emergency tiller.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 22 April 2022
Resolution: Replaced tiller and satisfactory operation test
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 April 2021 Resolved
Make keel cooler shut off valve in a ready to operate condition.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 1 June 2021
Resolution: Email verification received from vessel owner/captain.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 April 2021 Resolved
Fuel return line on main engine found with surface cracks. To be replaces using SAE J1942 rated hose or replacement in kind with hose meeting the standard in 182.20-40 (a)(2)(ii). Extended requirement to next annual.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 May 2022
Resolution: Installed new hose.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 April 2021 Resolved
Items located ontop of batteries to be removed. Do not store items on top of batteries.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 1 June 2021
Resolution: Email verification received from vessel owner/captain.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 28 April 2021 Resolved
Replace hatch for lazzarette.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 1 June 2021
Resolution: Email verification received from vessel owner/captain.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 April 2021 Resolved
30 adult lifejackets and 7 children are onboard in servicable condition. Passenger count is limited to 30 adult and 7 children until additional lifejackets are provided.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 June 2021
Resolution: Email verification received from vessel owner/captain.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 April 2021 Resolved
20 adult life jackets require renewal of reflective tape and must be taken out of service until tape is renewed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 July 2021
Resolution: Verified reflective tape was placed on lifejackets.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 28 April 2021 Resolved
At each initial and subsequent inspection for certification, the Marine Inspector may require that an abandon ship or man overboard drill be held under simulated emergency conditions specified by the inspector. Vessel was not prepared for drills as requested. Given the change of owner and new crew, one is required to be carried out. After multiple failed attempts to follow through with scheduled attendances to carry out out drills, it is now required to be carried out in the presence of a USCG Marine Inspector PRIOR to the vessel carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 July 2021
Resolution: Conducted drills.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 April 2021 Resolved
THE OCMI MAY REQUIRE AN INSPECTION PRIOR TO THE ISSUANCE OF AN AMENDED COI. VESSEL'S COI IS NOT VALID DUE TO CHANGE IN OWNER. OWNER MUST OBTAIN VALID COD AND MAKE VESSEL READY FOR INSPECTION PRIOR TO OPERATION AS A SMALL PASSENGER VESSEL
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 April 2021
Resolution: Verified that NVDC has recieved the new owner's documentation and the update of COD is in process.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 20 May 2020 Resolved
Provision shall be made by means of plugs, covers, etc. to prevent the admission of air into the space protected. Vessel does not have means to close off engine room ventilation.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2020
Resolved 1 June 2021
Resolution: Vessel is not fitted with CO2 and therefore not required to have means to block off ventilation.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 20 May 2020 Resolved
A vessel must carry either a first aid kit approved under 160.041 or a kit with equivalent contents and instructions. First aid kit missing various required items. Ensure contents include everything in list provided.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2020
Resolved 1 June 2021
Resolution: Email from Captain/Owner to rectify deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 April 2019 Resolved
Replace 01 defective lifejackets, 15 need new retro tape, 2 child jackets also need new retro tape.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 April 2019
Resolved 23 April 2019
Resolution: Lifejacket(s) were replaced, repaired, and retro renewed.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 17 April 2019 Resolved
Starboard side, aft end, in Lazaret thier is a hole in the side of the vessel IWO a deck scupper. Make permenant repair to satisfaction of attending MI.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 April 2019
Resolved 23 April 2019
Resolution: Hole was repaired, conducted hose test, all sat
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 April 2019 Resolved
Label E-fuel shut offs.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2019
Resolved 23 April 2019
Resolution: Fuel shut offs were labeled with stickers
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 April 2019 Resolved
Clean genarator windings.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2019
Resolved 23 April 2019
Resolution: Entire gen was cleaned.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 April 2019 Resolved
Fix exhaust leak, STBD side main engine
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2019
Resolved 23 April 2019
Resolution: Exahst leak was fixed with by tightening the manifold bolts.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 April 2019 Resolved
Install draft marks at next DD
Action required: 705 - Other - as specified
Due 17 April 2019
Resolved 23 April 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 April 2019 Resolved
Renew radio Station License.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2019
Resolved 23 April 2019
Resolution: Raido station license was renewed.
Lifesaving › Buoyant Apparatus › Pendant
Issued 25 September 2015 Resolved
Pendants were in unserviceable condition. Renew with 12 ft sections double over using at minimum 1/4" diameter line of the appropriate marine type.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 October 2015
Resolved 9 October 2015
Resolution: Renewed pendants with line of the appropriate type.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 25 September 2015 Resolved
Dual BA arrangement is not equipped with an approved waterlight.
Due 14 October 2015
Resolved 9 October 2015
Resolution: Waterlight is installed with the proper 18 ft 3/8" lanyard.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 25 September 2015 Resolved
Life bouy currently has 24 ft of life line. Renew lifeline with buoyant lifeline of 60 ft which is at least 5/16" in diameter.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 October 2015
Resolved 9 October 2015
Resolution: 60 ft floating line properly installed around the body of the buoy.
Communications › Radio Communications › EPIRB
Issued 21 September 2010 Resolved
Hydrostatic release expired. Issued 835 requirement: Prior to carrying passengers, renew hydrostatic release prior to carrying passengers > 3 nm from shore.
Action required: 705 - Other - as specified
Resolved 4 October 2010
Resolution: Owner provided photo via e mail of new hydrostatic release with date of 09/10.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 16 June 2006 Resolved
None of the portable fire extinguishers on the vessel have been serviced properly, they are all expired.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2015
Resolved 24 September 2015
Resolution: MAPPED OVER FROM PREVIOUS SYSTEM. NOT CURRENT.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 14 July 2004 Resolved
Small hole in weld on the top of the buoyant apparatus.
Condition: Improper/Lack of Maintenance
Due 13 August 2004
Resolved 23 September 2004
Lifesaving › Buoyant Apparatus › Lifeline
Issued 14 July 2004 Resolved
Lifeline on both buoyant apparatus' are worn and breaking apart.
Condition: Improper/Lack of Maintenance
Due 13 August 2004
Resolved 23 August 2004
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 14 July 2004 Resolved
Retroreflective material on lifebuoy is worn and needs to be replaced.
Condition: Improper/Lack of Maintenance
Due 13 August 2004
Resolved 23 August 2004
Electrical › Lighting (service) › Lighting Fixture
Issued 14 July 2004 Resolved
Deck light missing from post on cabin top port side.
Condition: Improper/Lack of Maintenance
Due 13 August 2004
Resolved 23 August 2004
Engineering
Issued 17 May 1999 Resolved
REPAIR ENGINE TACHOMETER AT THE OPERATING STATION.
Condition: Unknown
Due 24 September 2015
Resolved 24 September 2015
Resolution: MAPPED OVER FROM PREVIOUS SYSTEM. NOT CURRENT.
Construction/Loadline
Issued 17 May 1999 Resolved
INSTALL BILGE HIGH LEVEL ALARMS IN THE ENGINE ROOM AND STEERING GEAR ROOM.
Condition: Unknown
Due 24 September 2015
Resolved 24 September 2015
Resolution: MAPPED OVER FROM PREVIOUS SYSTEM. NOT CURRENT.
Lifesaving
Issued 17 May 1999 Resolved
INSTALL AN FCC CAT 1 406MHZ EPIRB. VESSEL LIMITED TO NO MORE THAN 3 MILES FROM THE NEAREST LAND.
Condition: Unknown
Due 17 June 1999
Resolved 26 May 1999
Fire Fighting
Issued 17 May 1999 Resolved
AS PROPOSED, MAKE ENGINE ROOM HATCH COVERS STEEL, IN LIEU OF INSTALLING A FIXED FIRE FIGHTING SYSTEM.
Condition: Unknown
Due 24 September 2015
Resolved 24 September 2015
Resolution: MAPPED OVER FROM PREVIOUS SYSTEM. NOT CURRENT.
Engineering
Issued 8 May 1998 Resolved
RENEW BOTH SHAFT CUTLASS BEARINGS. VESSEL IS NOT TO OPERATE WITH PASSENGERS AFTER 08SEP98, UNLESS BEARINGS HAVE BEEN RENEWED AND INSPECTED BY A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 24 September 2015
Resolved 24 September 2015
Resolution: MAPPED OVER FROM PREVIOUS SYSTEM. NOT CURRENT.
Electrical
Issued 5 May 1997 Resolved
Use proper installation methods on wiring for bilge pump.
Condition: Unknown
Due 24 September 2015
Resolved 24 September 2015
Resolution: MAPPED OVER FROM PREVIOUS SYSTEM. NOT CURRENT.
Navigation
Issued 5 May 1997 Resolved
Provide emergency broadcast placard at operating station.
Condition: Unknown
Due 24 September 2015
Resolved 24 September 2015
Resolution: MAPPED OVER FROM PREVIOUS SYSTEM. NOT CURRENT.
Electrical
Issued 5 May 1997 Resolved
Properly label bilge pump switch and fuse in engine room.
Condition: Unknown
Due 24 September 2015
Resolved 24 September 2015
Resolution: MAPPED OVER FROM PREVIOUS SYSTEM. NOT CURRENT.
Navigation
Issued 5 May 1997 Resolved
Provide proper illumination for magnetic compass.
Condition: Unknown
Due 24 September 2015
Resolved 24 September 2015
Resolution: MAPPED OVER FROM PREVIOUS SYSTEM. NOT CURRENT.
Lifesaving
Issued 5 May 1997 Resolved
Properly mark distress signal container and color it with a bright color.
Condition: Unknown
Due 24 September 2015
Resolved 24 September 2015
Resolution: MAPPED OVER FROM PREVIOUS SYSTEM. NOT CURRENT.
Lifesaving
Issued 5 May 1997 Resolved
Provide 3 adult lifejackets prior to the carriage of passengers.
Condition: Unknown
Due 24 September 2015
Resolved 24 September 2015
Resolution: MAPPED OVER FROM PREVIOUS SYSTEM. NOT CURRENT.
Electrical
Issued 5 May 1997 Resolved
Provide cover plate on junction box in engine room overhead on the port side.
Condition: Unknown
Due 24 September 2015
Resolved 24 September 2015
Resolution: MAPPED OVER FROM PREVIOUS SYSTEM. NOT CURRENT.
Construction/Loadline
Issued 27 August 1996 Resolved
Permanently install air receiver in accordance with Subchapter F requirements.
Condition: Unknown
Due 24 September 2015
Resolved 24 September 2015
Resolution: MAPPED OVER FROM PREVIOUS SYSTEM. NOT CURRENT.
Navigation
Issued 27 August 1996 Resolved
Provide proper magnetic compass with current deviation table.
Condition: Unknown
Due 24 September 2015
Resolved 24 September 2015
Resolution: MAPPED OVER FROM PREVIOUS SYSTEM. NOT CURRENT.
Construction/Loadline
Issued 29 May 1996 Resolved
Install new gasket for lazzerette hatch and prove water tightness._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 September 2015
Resolved 24 September 2015
Resolution: MAPPED OVER FROM PREVIOUS SYSTEM. NOT CURRENT.
Engineering
Issued 29 May 1996 Resolved
Properly install new fuel fill hoses with properly attached grounding wires.
Condition: Unknown
Due 24 September 2015
Resolved 24 September 2015
Resolution: MAPPED OVER FROM PREVIOUS SYSTEM. NOT CURRENT.
Accommodation/Occupational Safety
Issued 29 May 1996 Resolved
Provide 30x30 mesh falme screen for sewage vent._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 September 2015
Resolved 24 September 2015
Resolution: MAPPED OVER FROM PREVIOUS SYSTEM. NOT CURRENT.
Construction/Loadline
Issued 29 May 1996 Resolved
Permanently install air reciever in accordance with subchapter F requirements._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 September 2015
Resolved 24 September 2015
Resolution: MAPPED OVER FROM PREVIOUS SYSTEM. NOT CURRENT.
Navigation
Issued 29 May 1996 Resolved
Provide proper magnetic compass with current deviation table.
Condition: Unknown
Due 24 September 2015
Resolved 24 September 2015
Resolution: MAPPED OVER FROM PREVIOUS SYSTEM. NOT CURRENT.
Engineering
Issued 29 May 1996 Resolved
Provide proper lagging for main engine exhaust elbows.
Condition: Unknown
Due 24 September 2015
Resolved 24 September 2015
Resolution: MAPPED OVER FROM PREVIOUS SYSTEM. NOT CURRENT.
Lifesaving
Issued 29 May 1996 Resolved
Provide 6 foot lanyard for ring buoy._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 September 2015
Resolved 24 September 2015
Resolution: MAPPED OVER FROM PREVIOUS SYSTEM. NOT CURRENT.
Documentation
Issued 20 September 1995 Resolved
PROVIDE PROPER DOCUMENTATION OR CONDUCT SIMPLIFIED STABILITY TEST. TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR PRIOR TO CARRIAGE OF PASSENGERS FOR THE SPRING 1996 SEASON.
Condition: Unknown
Due 24 September 2015
Resolved 24 September 2015
Resolution: MAPPED OVER FROM MSIS. NOT CURRENT.
Lifesaving
Issued 28 June 1995 Resolved
CONDUCT SAFETY DRILLS WHILE UNDERWAY.
Condition: Unknown
Due 24 September 2015
Resolved 24 September 2015
Resolution: MAPPED OVER FROM PREVIOUS SYSTEM. NOT CURRENT.
Documentation
Issued 28 June 1995 Resolved
PROVE PROPER STABILITY FOR ROUTE AND NUMBER OF PERSONS CARRIED.
Condition: Unknown
Due 24 September 2015
Resolved 24 September 2015
Resolution: MAPPED OVER FROM PREVIOUS SYSTEM. NOT CURRENT.
Construction/Loadline
Issued 28 June 1995 Resolved
LABEL BILGE SYSTEM WITH PROPER LABELS.
Condition: Unknown
Due 24 September 2015
Resolved 24 September 2015
Resolution: MAPPED OVER FROM PREVIOUS SYSTEM. NOT CURRENT.
Electrical
Issued 28 June 1995 Resolved
PROVIDE PROPER LEGEND FOR 12VOLT SYSTEM LOCATED IN PILOTHOUSE.
Condition: Unknown
Due 24 September 2015
Resolved 24 September 2015
Resolution: MAPPED OVER FROM PREVIOUS SYSTEM. NOT CURRENT.
Lifesaving
Issued 4 May 1994 Resolved
PROPERLY STENCIL 26 MAN BUOANCY APPARATUS AND EQUIPMENT.
Condition: Unknown
Due 24 September 2015
Resolved 24 September 2015
Resolution: MAPPED OVER FROM PREVIOUS SYSTEM. NOT CURRENT.
Lifesaving
Issued 4 May 1994 Resolved
PROVIDE TWO TYPE ONE ADULT LIFE JACKETS.
Condition: Unknown
Due 24 September 2015
Resolved 24 September 2015
Resolution: MAPPED OVER FROM PREVIOUS SYSTEM. NOT CURRENT.
Lifesaving
Issued 4 May 1994 Resolved
REPAIR TEARS IN LIFE RING.
Condition: Unknown
Due 24 September 2015
Resolved 24 September 2015
Resolution: MAPPED OVER FROM PREVIOUS SYSTEM. NOT CURRENT.
Navigation
Issued 4 May 1994 Resolved
PROVIDE CURRENT CHARTS AND PUBS.
Condition: Unknown
Due 24 September 2015
Resolved 24 September 2015
Resolution: MAPPED OVER FROM PREVIOUS SYSTEM. NOT CURRENT.
Electrical
Issued 4 May 1994 Resolved
INSTALL FUSE FOR BILGE PUMP IN ACCORDANCE WITH 46 CFR PART 183.
Condition: Unknown
Due 24 September 2015
Resolved 24 September 2015
Resolution: MAPPED OVER FROM PREVIOUS SYSTEM. NOT CURRENT.
Electrical
Issued 4 May 1994 Resolved
PROVE PROPER OPERATION OF ENGINE ROOM BATTERY CHARGER.
Condition: Unknown
Due 24 September 2015
Resolved 24 September 2015
Resolution: MAPPED OVER FROM PREVIOUS SYSTEM. NOT CURRENT.
Electrical
Issued 4 May 1994 Resolved
PROVIDE METAL CLIPS AS NEEDED FOR OVERHEAD CABLE RUNS IN ENGINE ROOM.
Condition: Unknown
Due 24 September 2015
Resolved 24 September 2015
Resolution: MAPPED OVER FROM PREVIOUS SYSTEM. NOT CURRENT.
Engineering
Issued 4 May 1994 Resolved
PROVIDE ENCLOSURES FOR REMOTE EMERGENCY FUEL SHUTOFFS.
Condition: Unknown
Due 24 September 2015
Resolved 24 September 2015
Resolution: MAPPED OVER FROM PREVIOUS SYSTEM. NOT CURRENT.
Fire Fighting
Issued 4 May 1994 Resolved
REPAIR OR REPLACE DAMAGED FIRE EXTINGUISHER BRACKETS IN ENGINE ROOM.
Condition: Unknown
Due 24 September 2015
Resolved 24 September 2015
Resolution: MAPPED OVER FROM PREVIOUS SYSTEM. NOT CURRENT.
Lifesaving
Issued 2 May 1990 Resolved
PROVIDE THREE ADDITIONAL ADULT PFD'S AND ONE ADDITIONAL CHILD PFD NOT LATERTHAN 20 MAY 1990. VESSEL MAY NOT CARRY MORE THAN SEVENTY-ONE (71) TOTAL PERSONS UNTIL THIS REQUIREMENT IS COMPLETED.
Condition: Unknown
Due 24 September 2015
Resolved 24 September 2015
Resolution: MAPPED OVER FROM PREVIOUS SYSTEM. NOT CURRENT.
Lifesaving
Issued 2 May 1990 Resolved
PROVIDE ONE RINGBUOY AND 60' HEAVING LINE PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 24 September 2015
Resolved 24 September 2015
Resolution: MAPPED OVER FROM PREVIOUS SYSTEM. NOT CURRENT.
Deck/Cargo
Issued 2 May 1990 Resolved
PROVIDE GUARD ON THE BELT DRIVE FOR THE ANCHOR WINDLASS.
Condition: Unknown
Due 24 September 2015
Resolved 24 September 2015
Resolution: MAPPED OVER FROM PREVIOUS SYSTEM. NOT CURRENT.
Engineering
Issued 2 May 1990 Resolved
INSULATE DRY PORTION OF ENGINE EXHAUST LINES.
Condition: Unknown
Due 24 September 2015
Resolved 24 September 2015
Resolution: MAPPED OVER FROM PREVIOUS SYSTEM. NOT CURRENT.
Electrical
Issued 2 May 1990 Resolved
PROVIDE PROVISIONS FOR MEASURING AMPS, VOLTS AND FREQUENCY ON AC GENERATOR.
Condition: Unknown
Due 24 September 2015
Resolved 24 September 2015
Resolution: MAPPED OVER FROM PREVIOUS SYSTEM. NOT CURRENT.
Lifesaving
Issued 26 May 1988 Resolved
VESSEL IS LIMITED TO 45 POB UNTIL ADDITIONAL PFD'S ARE PROVIDED AND INSPECTED NOT LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 24 September 2015
Resolved 24 September 2015
Resolution: MAPPED OVER FROM PREVIOUS SYSTEM. NOT CURRENT.
Navigation
Issued 26 May 1988 Resolved
VESSEL IS RESTRICTED TO SUNRISE TO SUNSET OPERATION UNTIL THE BOW RANGE LIGHT IS REPAIRED NOT LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 24 September 2015
Resolved 24 September 2015
Resolution: MAPPED OVER FROM PREVIOUS SYSTEM. NOT CURRENT.

Casualty record · 1

5 August 2025Routine · role: Involved in a Marine Casualty · activity 8203996
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record