Records from 2017 to 2026. Most recent: inspection, 26 June 2026.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 28 April 2023
Resolved
A vessel must carry a first aid kit approved under 160.041. Found expired aspirin. Replace.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2023
Resolved 22 August 2023
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 28 April 2023
Resolved
VHF radio displays "Low Battery". Determine the backup power to repair/replace to meet requirements.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2023
Resolved 22 August 2023
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 28 April 2023
Resolved
At each inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil. Found exscess oil accumulation within the bilges. Clean all oil from bilges.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2023
Resolved 13 September 2023
Resolution: Provided proof of clean bilges
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 28 April 2023
Resolved
The name of the vessel must be marked and number of persons capacity must be markedon each lifefloat. Vessel name and persons capacity are faded on both lifefloats.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2023
Resolved 13 September 2023
Resolution: Pax counts stenciled on raft
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 April 2023
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protectedby a cover, guard, or rail. Pulleys on the generator and main engine are exposed. Cover.
Operator to procure custom fabrication of guard.
To be cleared at next annual.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 May 2023
Resolved 20 June 2024
Resolution: corrected
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 22 April 2022
Resolved
The power fire pump shall be self-priming and of such size as to discharge an effective stream from a hose connected to the highest outlet. Fire pump had a cracked housing and was actively leaking. Fire pump to be replaced. Code: 60c
**Update**
Accepted as temporary repair. Vessel required to have 3 fire buckets on board in addition. Upon receipt of purchase order, will determine due date. Changed code to 705c
CITE
46 CFR 181.10-1(b)
Action required: 705 - Other - as specified
Resolved 15 February 2024
Resolution: New fire pump installed.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 22 April 2022
Resolved
The painter must: Be of at least 100 ft in length, but not less than 3 times the distance between the deck where buoyant apparatus is stowed and the lowest load waterline; Have a breaking strength of at least 1,500lbs; Be of a dark color if synthetic, or of a type certified to be resistant to deterioration from UV light; Be stowed in such a way that it runs out freely when the buoyant apparatus floats away from a sinking vessel. Painter for buoyant apparatus was sun damaged and frayed. Replace painter.
CITE
46 CFR 180.175(f)(3)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 May 2022
Resolution: Painter replaced.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 22 April 2022
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Alcohol testing devices are set to expire 30APR2022 with no replacements. Replace alcohol testing swabs.
CITE
46 CFR 185.212
46 CFR 4.06-15(a)(1)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 May 2022
Resolution: Obatined new alcohol testing swabs.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 22 April 2022
Resolved
At each inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil. Found excessive oil accumulation within bilges. Clean all oil from bilges.
CITE
46 CFR 176.830(b)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 May 2022
Resolution: Bilges cleaned.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 April 2022
Resolved
At each inspection, the owner or managing operator shall be prepared to conduct test and have vessel ready for inspection of machinery, fuel, and piping systems including: operational test of the means provided for pumping bilges. During test of bilge system, operator was unsure of which valves to open/close, which resulted in a discharge of oily bilge-water mix. Retest bilge system.
CITE
46 CFR 176.804(h)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 May 2022
Resolution: Tested bilge system.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 April 2022
Resolved
Each ring life buoy on a vessel must: be approved in accordance with 160.050 of this chapter. Grab line on ring buoy was frayed and sun damaged. Replace grab line.
CITE
46 CFR 180.70(b)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2022
Resolved 6 May 2022
Resolution: Replaced grab line.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 April 2022
Resolved
Each life jacket must be marked in clearly legible block capital letters with the vessel's name. The vessel's name on multiple adult life jackets was faded. Remark life jackets.
CITE
46 CFR 185.604(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2022
Resolved 6 May 2022
Resolution: Marked life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 April 2022
Resolved
Each life jacket must be marked with Type I retro-reflective material. The arrangement of the retro-reflective material applied must be as specified by IMO Resolution A.658(16). Retro-reflective tape on both child and adult life jackets were worn, missing and/or not reflective. Replace retro-reflective tape.
CITE
46 CFR 185.604(h)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2022
Resolved 6 May 2022
Resolution: Replaced retro-reflective tape.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 April 2022
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel missing (01) adult life jacket. Vessel restricted to 74 persons on board until new life jacket is obtained.
CITE
46 CFR 180.71(a)
Action required: 705 - Other - as specified
Resolved 15 February 2024
Resolution: 01 lifejacket provided.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 April 2022
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents. Several items (iodine) within first-aid kit were expired. Replace items.
CITE
46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2022
Resolved 6 May 2022
Resolution: Replaced first-aid kit items.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 April 2022
Resolved
Bilge pipe piercing the collision bulkhead shall be fitted with a screw-down valve located on the forward side of the collision bulkhead and operable from above the weather deck. In lieu thereof, a crew-down valve without a reach rod may be fitted to the bilge line on the after side of the collision bulkhead if it is readily accessible under service conditions. Vessel was found with no screw-down valve for the bilge pipe that pierces the collision bulkhead. Install screw-down valve that can either be operable from the weather deck or on the aft side of the bulkhead.
CITE
46 CFR 182.25-5(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2022
Resolved 6 May 2022
Resolution: Installed screw-down valve on aft side of collision bulkhead
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 April 2022
Resolved
At each inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Hazardous and flammable items were stowed out in the open of the engine room. Hazardous/flammable stores to be removed from the engine room and stowed properly.
CITE
46 CFR 176.830(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2022
Resolved 6 May 2022
Resolution: Removed items from engine room.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 April 2022
Resolved
Batteries shall be effectively screened by a cage or similar structure to minimize the danger of accidental park through dropping a metal object across the terminals. Batteries in engine room did not have a cover to protect terminals. Install cover.
CITE
46 CFR 183.05-20(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2022
Resolved 6 May 2022
Resolution: Installed battery covers
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 April 2022
Resolved
Battery terminals shall be of the soldered type and all connections shall be made to the battery terminals with permanent type connectors. Battery in engine room had wing nuts on post. Remove wing nuts and replace with proper connector.
CITE
46 CFR 183.05-20(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2022
Resolved 6 May 2022
Resolution: Removed wing nuts and installed proper connectors.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 22 April 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible. Vessel's charts were had not been updated. Update charts.
CITE
46 CFR 184.420(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2022
Resolved 6 May 2022
Resolution: Updated charts.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 22 April 2022
Resolved
Vessel must be fitted with a suitable magnetic compass designed for marine use. Vessel's magnetic compass did not have a deviation card. Obtain deviation card.
CITE
46 CFR 184.402(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2022
Resolved 15 February 2024
Resolution: Deviation card provided.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 22 April 2022
Resolved
Drills and training shall be logged. Entry shall include the following information: Date of drill and training. Missing year on dates within logbooks. Ensure logging of year on dates.
CITE
46 CFR 185.524(d)(1)
46 CFR 185.520(f)(1)
Action required: 10 - Deficiency Rectified
Resolved 22 April 2022
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 22 April 2022
Resolved
No marine employer shall engage or employ any individual to serve as a crew member unless the individual passes a chemical test for dangerous drugs for that employer. Vessel operated during the 2021 season with multiple different people that served as a deckhand and were not chemical tested. Vessel to operate only with crew members that have completed a chemical test.
CITE
46 CFR 16.210(a)
Action required: 10 - Deficiency Rectified
Resolved 22 April 2022
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 22 April 2022
Resolved
Employers must maintain records of chemical tests as provided in 49 CFR 40.333 and must make these records available to Coast Guard officials upon request. Requested records for deckhands used during 2021 season that were not a part of the third party consortium that the marine employer used for crew. Marine employer did not have records for deckhands as they were not tested nor enrolled in another third party consortium. Marine employer to maintain records of chemical tests for all employees.
CITE
46 CFR 16.260
Action required: 10 - Deficiency Rectified
Resolved 22 April 2022
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 22 April 2022
Resolved
Inspection and maintenance of the survival craft shall be logged or otherwise documented for review by the Coast Guard upon request. EPIRB test required shall be logged or otherwise documented. Monthly safety checks were not logged. Log monthly safety checks.
CITE
46 CFR 185.702(d)
46 CFR 185.728(c)
Action required: 10 - Deficiency Rectified
Resolved 22 April 2022
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 22 April 2022
Resolved
Each survival craft on a vessel must be inspected monthly, using the manufacturer's instructions to make sure it is complete and in good order. Each EPIRB must be tested monthly. Monthly checks were not completed. Complete monthly checks.
CITE
46 CFR 185.722
46 CFR 185.728(a)
Action required: 10 - Deficiency Rectified
Resolved 22 April 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 22 April 2022
Resolved
A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection (COI). Vessel's COI expired on 10 APR 2022. Completed COI Renewal on 22 APR 2022.
CITE
46 CFR 176.100(a)
Action required: 10 - Deficiency Rectified
Resolved 22 April 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 April 2022
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. Vessel completed unauthorized repairs to the fire pump. Vessel to complete repairs only with approval from cognizant [name withheld]
46 CFR 176.700(a)
Action required: 10 - Deficiency Rectified
Resolved 22 April 2022
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Procedure for inspection, reporting and correcting unsafe conditions and for investigating a
Issued 22 April 2022
Resolved
Immediately after the addressing of resultant safety concerns, the owner, agent, master, or person in charge of a vessel involved in a marine casualty shall notify the nearest Sector Office, Marine Inspection Office whenever a vessel is involved in a marine casualty consisting of: An occurrence materially and adversely affecting the vessel's seaworthiness or fitness for service or route. Vessel did not report issue with fire pump to Coast Guard. Vessel to report all marine casualties to Coast Guard.
CITE
46 CFR 185.202(a)(4)
Action required: 10 - Deficiency Rectified
Resolved 22 April 2022
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 28 April 2021
Resolved
Provide proof of enrollment in random drug testing program.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 1 June 2021
Resolution: Email verification received from vessel owner/captain.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 28 April 2021
Resolved
Update coast pilot, light list and electronic charts.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 1 June 2021
Resolution: Email verification received from vessel owner/captain.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 28 April 2021
Resolved
Develop a waste management plan.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 1 June 2021
Resolution: Email verification received from vessel owner/captain.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 28 April 2021
Resolved
Repair mast headlight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 23 July 2021
Resolution: Verified installation and operation
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 28 April 2021
Resolved
Provide first adi kit in a watertight container with instructions and required content.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 1 June 2021
Resolution: Email verification received from vessel owner/captain.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 28 April 2021
Resolved
Renew batteries in engine room flashlight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2021
Resolved 30 July 2021
Resolution: Batteries renewed.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 28 April 2021
Resolved
Renew hydrostatic release for EPIRB. Vessel is limited to 3NM from shore until renewed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 July 2021
Resolution: Verified proper installation and marking of hydrostatic release.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 28 April 2021
Resolved
Replace light for lifefloat.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 June 2021
Resolution: Email verification received from vessel owner/captain.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 April 2021
Resolved
Provide lights for PFD's. Route is limited to less than 20NM from harbor of safe refuge until provided.
Update: owner does not want to purchase lights, but wants to keep route for greater than 20nm from harbor of safe refuge even though he is not operating as such now. Will revisit at next annual to restrict the route, amend the COI, or include a statement to say if the vessel operates greater than 20nm from HSR, then lights are needed IAW 46 CFR 180.75
Action required: 705 - Other - as specified
Resolved 16 May 2022
Resolution: Amended COI
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 April 2021
Resolved
Replace battery in floating waterlight on ring lifebuoy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 July 2021
Resolution: Verified new batteries were placed into service on the waterlights for the lifering and life floats.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 April 2021
Resolved
Provide new labels for fuel shut off and life jacket stowage.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 June 2021
Resolution: Email verification received from vessel owner/captain.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 28 April 2021
Resolved
Replace flame screen on port fuel vent.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 23 July 2021
Resolution: New flame screens have been installed on the fuel vent by glue. Vent arrangement is such that the gooseneck cap can be unscrewed for easy removal and cleanout.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 April 2021
Resolved
Replace fire nozzle to corrosion resistant and capable of changing between a solid stream and a spray pattern.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 June 2021
Resolution: Email verification received from vessel owner/captain.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 28 April 2021
Resolved
Replace emergency tiller.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 22 April 2022
Resolution: Replaced tiller and satisfactory operation test
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 April 2021
Resolved
Make keel cooler shut off valve in a ready to operate condition.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 1 June 2021
Resolution: Email verification received from vessel owner/captain.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 April 2021
Resolved
Fuel return line on main engine found with surface cracks. To be replaces using SAE J1942 rated hose or replacement in kind with hose meeting the standard in 182.20-40 (a)(2)(ii). Extended requirement to next annual.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 May 2022
Resolution: Installed new hose.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 April 2021
Resolved
Items located ontop of batteries to be removed. Do not store items on top of batteries.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 1 June 2021
Resolution: Email verification received from vessel owner/captain.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 28 April 2021
Resolved
Replace hatch for lazzarette.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 1 June 2021
Resolution: Email verification received from vessel owner/captain.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 April 2021
Resolved
30 adult lifejackets and 7 children are onboard in servicable condition. Passenger count is limited to 30 adult and 7 children until additional lifejackets are provided.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 June 2021
Resolution: Email verification received from vessel owner/captain.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 April 2021
Resolved
20 adult life jackets require renewal of reflective tape and must be taken out of service until tape is renewed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 July 2021
Resolution: Verified reflective tape was placed on lifejackets.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 28 April 2021
Resolved
At each initial and subsequent inspection for certification, the Marine Inspector may require that an abandon ship or man overboard drill be held under simulated emergency conditions specified by the inspector.
Vessel was not prepared for drills as requested. Given the change of owner and new crew, one is required to be carried out. After multiple failed attempts to follow through with scheduled attendances to carry out out drills, it is now required to be carried out in the presence of a USCG Marine Inspector PRIOR to the vessel carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 July 2021
Resolution: Conducted drills.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 April 2021
Resolved
THE OCMI MAY REQUIRE AN INSPECTION PRIOR TO THE ISSUANCE OF AN AMENDED COI. VESSEL'S COI IS NOT VALID DUE TO CHANGE IN OWNER. OWNER MUST OBTAIN VALID COD AND MAKE VESSEL READY FOR INSPECTION PRIOR TO OPERATION AS A SMALL PASSENGER VESSEL
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 April 2021
Resolution: Verified that NVDC has recieved the new owner's documentation and the update of COD is in process.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 20 May 2020
Resolved
Provision shall be made by means of plugs, covers, etc. to prevent the admission of air into the space protected. Vessel does not have means to close off engine room ventilation.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2020
Resolved 1 June 2021
Resolution: Vessel is not fitted with CO2 and therefore not required to have means to block off ventilation.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 20 May 2020
Resolved
A vessel must carry either a first aid kit approved under 160.041 or a kit with equivalent contents and instructions. First aid kit missing various required items. Ensure contents include everything in list provided.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2020
Resolved 1 June 2021
Resolution: Email from Captain/Owner to rectify deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 April 2019
Resolved
Replace 01 defective lifejackets, 15 need new retro tape, 2 child jackets also need new retro tape.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 April 2019
Resolved 23 April 2019
Resolution: Lifejacket(s) were replaced, repaired, and retro renewed.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 17 April 2019
Resolved
Starboard side, aft end, in Lazaret thier is a hole in the side of the vessel IWO a deck scupper. Make permenant repair to satisfaction of attending MI.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 April 2019
Resolved 23 April 2019
Resolution: Hole was repaired, conducted hose test, all sat
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 April 2019
Resolved
Label E-fuel shut offs.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2019
Resolved 23 April 2019
Resolution: Fuel shut offs were labeled with stickers
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 April 2019
Resolved
Clean genarator windings.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2019
Resolved 23 April 2019
Resolution: Entire gen was cleaned.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 April 2019
Resolved
Fix exhaust leak, STBD side main engine
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2019
Resolved 23 April 2019
Resolution: Exahst leak was fixed with by tightening the manifold bolts.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 April 2019
Resolved
Install draft marks at next DD
Action required: 705 - Other - as specified
Due 17 April 2019
Resolved 23 April 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 April 2019
Resolved
Renew radio Station License.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2019
Resolved 23 April 2019
Resolution: Raido station license was renewed.