SIGHTSEER

SIGHTSEER is a 1960 passenger vessel (inspected). The Coast Guard has recorded 66 inspections since 1985, most recently in May 2025, along with 40 deficiencies and 2 casualty investigations between 2005 and 2008.

Records from 1985 to 2025. Most recent: inspection, 21 May 2025.

Built
1960
Last inspected
21 May 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDN 9993
Flag
UNITED STATES
367190770, 368332190
Maury page id
psix-43911

Inspections, by type

…with no type recorded4
Years with a record 37 calendar years (1985–2025)
The 66 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)62.0 ft × 22.0 ft × 7.0 ft
Registered tonnagegross 64 / net 44
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSHERMAN BOAT WORKS CO. · LONG BEACH, CA, UNITED STATES · built 1960
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSEATTLE, WA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 19 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it64 - Regulatory (Subpart C or D), Gross Ton
44 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDN9993MMSI 368332190 · active · compulsorily equipped · granted 7 September 2023, expires 7 September 2033
WP3995MMSI 367190770 · active · compulsorily equipped · granted 17 August 2017, expires 22 October 2027
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 66

21 May 2025 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8141883
1 May 2024 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8038878
20 June 2023 COI Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7719550
8 November 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7592344
20 September 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7562898
3 November 2021 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7344950
10 February 2021 Internal Structural Exam · Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7134173
17 November 2020 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7095879
13 November 2019 Annual Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6851757
13 November 2018 DAPI Audit · Internal Structural Exam · In-Service Inspection · Drydock Exam · Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6578073
10 October 2017 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6284552
20 January 2017 Drydock Exam · Internal Structural Exam · In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6070522
15 November 2016 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6035662
10 November 2015 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5761491
8 December 2011 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4204514
12 November 2010 MTSA Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3888140
8 December 2009 DAPI Audit
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3647998
2 February 2009 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3402640
28 October 2008 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3352813
28 August 2008 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3316920
15 November 2007 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3095933
18 April 2007 Hull Examination · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2910481
11 October 2005 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2517151
23 August 2005 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2472579
19 August 2005 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2472270
21 April 2005 Internal Structural Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2339736
15 November 2004 Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2241346
22 April 2004 Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2050041
23 March 2004 Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2029905
20 January 2004 Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1988401
25 June 2003 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1825028
26 November 2002 Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1710502
20 November 2001 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1433915
27 April 2001 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1066556
19 June 2000 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 819570
17 November 1999 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1386635
19 November 1998 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1423103
29 April 1998 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 790310
18 March 1998 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1419906
19 November 1997 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1462605
19 November 1996 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1383380
1 December 1995 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1186454
21 November 1995 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1387892
20 March 1995 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1394284
23 November 1994 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1355019
22 December 1993 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 849142
23 November 1993 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 846119
26 January 1993 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 829177
31 December 1992 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 961371
25 November 1992 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1376896
4 March 1992 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1310095
26 November 1991 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 940349
30 July 1991 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1244115
30 July 1991 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1244879
27 November 1990 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1225947
12 September 1990 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 912770
28 November 1989 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1234540
6 March 1989 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1200546
16 December 1988 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 902186
30 November 1988 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1207519
22 January 1988 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1322460
24 November 1987 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1333351
23 February 1987 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1002999
25 November 1986 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1019483
27 February 1986 Credit Drydock
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1298182
26 November 1985 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 995559

Deficiency record · 40

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 May 2025 Resolved
Each lifeline on a ring buoy must be buoyant, at least 60 feet in length, non-kinking, & diameter = 5/16". Lifeline is < 60 feet.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2025
Resolved 29 May 2025
Resolution: Received confirmation of lifeline replacement with compliant line.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 May 2025 Resolved
Each ring life buoy must be marked with Type II retroreflective material approved IAW 46CFR164.018 or other approved standard. White ring buoys are missing retroreflective tape.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2025
Resolved 29 May 2025
Resolution: Received confirmation of retro adequately applied to the white ring buoys. Alternate arrangement of retro accepted on vessel name side of ring buoy, allowing 5 strips around face without modification of vessel name stencilling or covering.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 June 2023 Resolved
46 CFR 183.340 Cable and wiring requirements. Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Exposed connections/dead-end cables within engine room; add junction boxes/rewire as necessary to meet requirements.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2023
Resolved 15 July 2023
Resolution: Provided photographic evidence of corrected condtion.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 20 June 2023 Resolved
46 CFR 177.405 (a) Fire Protection; General arrangement and outfitting. Fire hazards to be minimized: The general construction of the vessel must be such as to minimize fire hazards insofar as it is reasonable and practicable. Installing new vinyl floor-covering- replacement not in kind. Provide MSDS from manufacturer; verify safe for passengers in case of fire/does not produce toxic fumes harmful to people on board.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 June 2023
Resolved 15 July 2023
Resolution: Provided requested documentation for flooring material.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 8 November 2022 Resolved
Materials used in the piping systems must meet the requirements of this subpart and be otherwise acceptable to the cognizant [name withheld] discovered soft patch on overboard deck drain pipe in starboard void midship.
Action required: 10 - Deficiency Rectified
Due 8 November 2022
Resolved 23 January 2023
Resolution: Recieved photo of proper repair.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 February 2021 Resolved
Child size life preservers not stored in seperate location IAW 46 CFR 117.78 (a)(5)
Action required: 10 - Deficiency Rectified
Due 24 February 2021
Resolved 10 February 2021
Resolution: Divider added to PFD storage.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 November 2019 Resolved
Jacket on coolant hose for main engine was cracked and not adequate for intended service.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2019
Resolved 14 November 2019
Resolution: Replaced hose jacket.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 13 November 2019 Resolved
Ring life buoy is not of service ability.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2019
Resolved 14 November 2019
Resolution: Replaced ring life buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 13 November 2019 Resolved
Hydrostatic releases were past servicing dates.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2019
Resolved 14 November 2019
Resolution: Replaced hydrostatic releases.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 13 November 2019 Resolved
Monthly inspection of fire extinguishers was not conducted/documented.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2019
Resolved 14 November 2019
Resolution: Inspected all fire extinguishers.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 13 November 2019 Resolved
Scupper flaps for wells did not properly operate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2019
Resolved 14 November 2019
Resolution: Conducted maintenance on scupper flaps.
Construction/Loadline › Hull › Bottom Plating
Issued 2 February 2009 Resolved
Owner directed to conduct NDT tests of the hull plate on the bottom side of the keel cooler, sound back to good metal. Initial soundings indicated excess of 40% wastage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 4 February 2009
Resolution: UT shots were taken, wasted metal located and isolated to an area 18" X 10'''' from frame # to #. Note vessel is numbered from the stern.
Construction/Loadline › Hull › Hull Plating
Issued 2 February 2009 Resolved
Crop out and renew wasted hull plating, frame 13 to frame 20 P&S sides of the keel, out 18" or to good metal.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 February 2009
Resolved 13 February 2009
Resolution: Hull plate renewed, NDT''ed, all sat.
Engineering › Sea-water System (primary cooling) › Piping
Issued 15 November 2007 Resolved
- double clamp hoses in machinery space servicing vital fluid systems
Due 30 November 2007
Resolved 29 November 2007
Resolution: Provided digital photos of double clamps
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 15 November 2007 Resolved
- separate child life jackets from adult
Due 30 November 2007
Resolved 29 November 2007
Resolution: provided digital photos of satisfactory storage; placed wood panel as divider in life jacket lockers to separate child PFD from adult
Stability › Severe Wind/Roll › General
Issued 15 November 2007 Resolved
- at ladder leading to upper deck label max capacity for same
Due 30 November 2007
Resolved 29 November 2007
Resolution: received satisfactory invoice of labeling for upper deck capacity
Engineering › Electric Propulsion System › Circuit Board
Issued 23 August 2005 Resolved
Micro commander for control of main propulsion engines is not operating properly.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 August 2005
Resolved 23 August 2005
Resolution: Replaced Micro commander and tested operation, all sat.
Navigation
Issued 21 November 1995 Resolved
INSTALL RELIEF VALVE FOR AIR RECEIVER SERVICING VESSEL'S WHISTLE PRIOR TO OPERATING VESSEL'S AIR COMPRESSOR, TO THE SATISFACTION OF THE ATTENDING C.G. MARINE INSPECTOR._x001C_ (VALVE REQUIRED TO LIFT PRIOR TO ATTAINING 125PSI)
Condition: Unknown
Due 5 December 1995
Resolved 6 December 1995
Lifesaving
Issued 21 November 1995 Resolved
PROPERLY MARK PERSONAL FLOATATION DEVICE STOWAGE LOCKER ON UPPER DECK TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 5 December 1995
Resolved 6 December 1995
Fire Fighting
Issued 21 November 1995 Resolved
PROVIDE A TOTAL OF FIVE SERVICEABLE B-II PORTABLE FIRE FIGHTING EXTINGUISHERS PRIOR TO SAILING. TO BE COMPLETED TO THE SATISFACTION OF THEATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 5 December 1995
Resolved 27 November 1995
Accommodation/Occupational Safety
Issued 21 November 1995 Resolved
REPLACE CRACKED WINDOW LOCATED ON HEAD DOOR STBD MAIN DECK, TO THE SATISFACTION OF THE ATTENDING C.G. MARINE INSPECTOR.
Condition: Unknown
Due 5 December 1995
Resolved 6 December 1995
Lifesaving
Issued 21 November 1995 Resolved
REMOVE ALL TYPE III PFDs FROM VESSEL, TO THE SATISFACTION OF THE ATTENDING C.G. MARINE INSPECTOR.
Condition: Unknown
Due 5 December 1995
Resolved 6 December 1995
Electrical
Issued 21 November 1995 Resolved
REPLACE THE GLASS BULB FOR MOST FORWARD PASSAGEWAY LIGHT LOCATED ON PORT MAIN DECK, TO THE SATISFACTION OF THE ATTENDING C.G. MARINE INSPECTOR.
Condition: Unknown
Due 5 December 1995
Resolved 6 December 1995
Lifesaving
Issued 21 November 1995 Resolved
VESSEL'S PASSENGER CAPACITY IS REDUCED TO 250 PERSONS UNTIL AN ADDITIONAL 90 ADULT TYPE I PFD'S ARE PROVIDED, TO THE SATISFACTION OF THE ATTENDING C.G. MARINE INSPECTOR.
Condition: Unknown
Due 5 December 1995
Resolved 6 December 1995
Electrical
Issued 21 November 1995 Resolved
PROPERLY HARD WIRE FREEZER LOCATED IN AFT STOWAGE ROOM TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 5 December 1995
Resolved 6 December 1995
Engineering
Issued 23 November 1993 Resolved
INSTALL AND PROVE PROPER OPERATION OF THE RELEASE DEVICE FOR THE AIR COMPRESSOR WHICH WILL RELIEVE AT LESS THAN 125PSI.
Condition: Unknown
Due 23 November 1993
Resolved 23 November 1993
Electrical
Issued 25 November 1992 Resolved
ELECTRICAL CORD TO OVERHEAD LIGHT IN FWD SEWAGE COMPARTMENT IS LOOSE WITH WIRES HANGING IN OPEN.
Condition: Unknown
Due 3 January 1993
Resolved 12 January 1993
Accommodation/Occupational Safety
Issued 25 November 1992 Resolved
VSL DOES NOT HAVE WASTE MANAGEMENT PLAN FOR MARPOL 5.
Condition: Unknown
Due 3 January 1993
Resolved 12 January 1993
Engineering
Issued 25 November 1992 Resolved
OIL PRESSURE GAUGE ON BRIDGE DOES NOT WORK._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 January 1993
Resolved 12 January 1993
Construction/Loadline
Issued 25 November 1992 Resolved
FREEING PORTS ON MAIN DECK MUST HAVE COVERS REMOVED.
Condition: Unknown
Due 3 January 1993
Resolved 12 January 1993
Engineering
Issued 25 November 1992 Resolved
PROVIDE MANUFACTERS INFORMATION ON PREVIOUS AND CURRENT MAIN DIESEL ENGINE.
Condition: Unknown
Due 3 January 1993
Resolved 12 January 1993
Navigation
Issued 25 November 1992 Resolved
ANCHOR LIGHT INOPERABLE.
Condition: Unknown
Due 3 January 1993
Resolved 12 January 1993
Navigation
Issued 25 November 1992 Resolved
2.672 CU FT PRESSURE VESSEL NOT PROPERLY INSTALLED. NO PRESSURE GAUGE PRESENT.
Condition: Unknown
Due 25 November 1992
Resolved 25 November 1992
Fire Fighting
Issued 26 November 1991 Resolved
PROVIDE DOCUMENTATION THAT PROPER ANNUAL SERVICING OF ALL PORTABLE FIRE EXTINGUISHERS HAS BEEN CONDUCTED.
Condition: Unknown
Due 15 December 1991
Resolved 6 December 1991
Lifesaving
Issued 26 November 1991 Resolved
PROPERLY STENCIL VSL NAME AND CAPACITY ON EACH BUOYANT APPARATUS.
Condition: Unknown
Due 15 December 1991
Resolved 6 December 1991
Unknown
Issued 30 November 1988 Resolved
PROVIDE PRESSURE RELIEVING DEVICE ON AIR RECEIVER TO OPERATE AT A PRESSURE LESS THAN 100PSI OR MAKE AIR RECEIVER AVAILABLE FOR INSPECTION AS DISCRIBEDIN 46 CFR PART 54. THIS SHALL BE DONE TO THE SATISFACTION OF THE ATTENDING C. G. MARINE INSPECTOR AND NO LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 30 November 1988
Resolved 30 November 1988
Electrical
Issued 30 November 1988 Resolved
PROVIDE METAL HANGERS FOR HEATERS ELECTRICAL CABLE IN PASSENGER AREAS. THIS SHALL BE COMPLETED TO THE SATISFACTION OF THE ATTENDING C.G. MARINE INSPECTOR AND NO LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 30 November 1988
Resolved 30 November 1988
Lifesaving
Issued 24 November 1987 Resolved
PROVIDE PAINTER AND WEAK LINK INSTALLATION FOR ALL BUOYANT APPARATUS AS REQUIRED BY 46 CFR 180.20.1. THE ABOVE TO BE COMPLETED TO THE SATISFACTIONOF THE ATTENDING USCG MARINE INSPECTOR NOT LATER THAN 24 DEC 1987.
Condition: Unknown
Due 24 November 1987
Resolved 24 November 1987
Construction/Loadline
Issued 25 November 1986 Resolved
CROP AND RENEW MAIN DECK PLATE IN WAY OF EMERGENCY TELLER ACCESS, LAZERETTEACCESS AND UNDERDECK STIFFENERS AS REQUIRED APPROXIMATE 5 X 7 FOOT PLATE.
Condition: Unknown
Due 25 November 1986
Resolved 25 November 1986
Deck/Cargo
Issued 26 November 1985 Resolved
PERMANENTLY REPAIR CAPSTAN STUFFING TUBE AT NEXT REGULAR DRYDOCK, BUT IN NOCASE LATER THAN 1 MARCH 86.
Condition: Unknown
Due 26 November 1985
Resolved 26 November 1985

Casualty record · 2

19 August 2005Routine · role: Involved in a Marine Casualty · activity 2472270
28 August 2008Routine · role: Involved in a Marine Casualty · activity 3316920
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.