MAURY USCG vessel records
← All vessels

WINFIELD FERRY NO. 2

Built
1996
Last inspected
25 March 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 25 March 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 31 calendar years (1996–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

439241
Flag
UNITED STATES
Tonnage
85 - Regulatory (Subpart C or D), Gross Ton 85 - Regulatory (Subpart C or D), Net Ton
Maury page id
psix-439241
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 48

25 March 2026 Vessel Attendance · Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8319267
2 October 2025 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8243497
16 September 2024 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8024733
2 July 2024 Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7944468
5 October 2023 Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7784992
24 August 2022 COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7524644
14 September 2021 Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7291579
31 March 2021 Internal Structural Exam · Drydock Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7150742
19 November 2020 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7098517
9 September 2020 Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7049247
10 July 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6741963
6 November 2018 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6565811
11 June 2018 Spot Check
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6442272
3 August 2017 COI Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6229434
23 August 2016 Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5963447
7 April 2016 Administrative Inspection · Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5824762
22 September 2015 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5725327
29 July 2014 Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4930314
2 May 2014 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4848784
21 November 2013 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4756908
7 November 2013 Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4744087
31 July 2012 COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4396650
8 November 2011 Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4166447
19 July 2011 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4087390
21 October 2010 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3874735
16 July 2009 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3536503
16 July 2008 Administrative Inspection · DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3262820
6 September 2007 Administrative Inspection · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3049647
5 December 2006 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2834251
6 October 2006 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2794985
7 August 2006 Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2739459
1 December 2005 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2536659
16 November 2005 Annual Inspection · Administrative Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2527123
16 November 2004 Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2241978
15 September 2004 Annual Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2196620
23 September 2003 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1901503
3 October 2002 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1684015
17 September 2002 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1674348
15 January 2002 Hull Examination · Internal Structural Exam
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1478602
20 November 2001 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1076726
13 November 2001 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1376800
31 July 2001 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1075205
12 October 2000 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1424997
23 September 1999 COI Inspection · Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1402965
7 October 1998 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1378478
11 September 1998 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 800013
7 October 1997 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1409762
26 September 1996 Hull Examination · Deadweight Survey · Initial Certification · Plan Review "T" Boat
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1435748

Deficiency record · 23

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 November 2018 Resolved
46 CFR 180.71(e) requires PFDs required to marked IAW 46 CFR 185.604 (with vessel's name). Five PFDs not properly marked with vessel name.
Action required: 10 - Deficiency Rectified
Resolved 6 November 2018
Resolution: PFDs properly marked with vessel's name by the end of the inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 November 2018 Resolved
One of the three required life rings found with water intrusion into body of life ring compromising flotation.
Action required: 10 - Deficiency Rectified
Resolved 6 November 2018
Resolution: New ring life buoy properly stenciled and placed on board vessel.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 6 November 2018 Resolved
Spanner wrench required to be located with each fire hose. The vessel had two fire hoses and no spanner wrenches on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 December 2018
Resolved 11 December 2018
Resolution: New wrenches placed on board vessel.
Lifesaving › Lifebuoys › Serviceable
Issued 23 August 2016 Resolved
1 of the 3 ring life buoys required to be on board the vessel by 46 CFR 180.70 deemed to be "heavy" due to water logged interior material. Buoy removed from service due to the apparent loss of buoyancy and required to be replaced.
Action required: 705 - Other - as specified
Due 23 August 2016
Resolved 23 August 2016
Resolution: Ring life buoy replaced with approved and properly marked equipment.
Engineering › Bilge Water Management System › Strainer
Issued 7 April 2016 Resolved
Bilge suction strainers as required by 46 CFR 182.510 in the #2 and #9 voids require repair/replacement due to wastage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 27 April 2016
Resolution: Two new strainers properly installed.
Fire Fighting › Fire Main › Valves
Issued 28 August 2012 Resolved
The overboard discharge valve on the fire pump in the vicinity of void #9 leaked, water was bypassing valve gate.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 September 2012
Resolved 25 September 2012
Resolution: Witnessed installed new valve and proper operation.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 16 July 2008 Resolved
Casing for strobe light cracked.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2008
Resolution: New waterlight installed
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 16 July 2008 Resolved
Draft Marks not contrasting color to hull.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2008
Resolution: Draft marks painted
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 7 August 2006 Resolved
strongbacks on hatches for #1, 2, 3 and 4 voids are wasted and need replaced.
Condition: Unknown
Due 8 September 2006
Resolved 18 October 2006
Resolution: Witnessed new gaskets.
Lifesaving › Lifebuoys › Serviceable
Issued 16 November 2005 Resolved
Renew two (x2) life ring buoys. Two life ring buoys are cracking along the center seem.
Action required: 705 - Other - as specified
Due 1 December 2005
Resolved 1 December 2005
Accommodation/Occupational Safety › Occupational Safety
Issued 17 September 2002 Resolved
Properly install machinery guards for exposed pulleys and belts of engine aboard UTV CALHOUN LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Unknown
Due 17 October 2002
Resolved 3 October 2002
Navigation
Issued 13 November 2001 Resolved
PROPERLY INSTALL ALL WIRE ROPE CLIPS ON STEERING CABLE AND HOOK RELEASE.
Condition: Unknown
Due 13 November 2001
Resolved 13 November 2001
Construction/Loadline
Issued 13 November 2001 Resolved
PROVE PROPER OPERATION OF #1 THROUGH #9 BILGE PUMPS, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 13 November 2001
Resolved 13 November 2001
Lifesaving
Issued 13 November 2001 Resolved
REPLACE PORT AND STARBOARD LIFE RING
Condition: Unknown
Due 13 November 2001
Resolved 13 November 2001
Lifesaving
Issued 13 November 2001 Resolved
POST NO SMOKING SIGNS
Condition: Unknown
Due 13 November 2001
Resolved 13 November 2001
Lifesaving
Issued 13 November 2001 Resolved
REPAIR OR REPLACE FLOAT LIGHT
Condition: Unknown
Due 13 November 2001
Resolved 13 November 2001
Fire Fighting
Issued 13 November 2001 Resolved
REPLACE LENS ON FIRE PUMP GAUGE
Condition: Unknown
Due 13 November 2001
Resolved 13 November 2001
Navigation
Issued 13 November 2001 Resolved
REPAIR OR REPLACE STARBOARD RUNNING LIGHT.
Condition: Unknown
Due 13 November 2001
Resolved 13 November 2001
Construction/Loadline
Issued 13 November 2001 Resolved
REPAINT DRAFT MARKINGS ON HULL
Condition: Unknown
Due 13 November 2001
Resolved 13 November 2001
Navigation
Issued 13 November 2001 Resolved
PLACE GUARD OVER STEERING GEAR CABLES
Condition: Unknown
Due 13 November 2001
Resolved 13 November 2001
Construction/Loadline
Issued 23 September 1999 Resolved
Bilge system was not operational due to a faulty valve. Owners stated they only work valves during CG inspections once a year. Recommended that all bilge system valves be operated monthly to ensure proper operation.
Condition: Unknown
Due 7 October 1999
Resolved 7 October 1999
Engineering
Issued 23 September 1999 Resolved
Stop main diesel engine oil leaks on M/V Calhoun.
Condition: Unknown
Due 7 October 1999
Resolved 7 October 1999
Lifesaving
Issued 11 September 1998 Resolved
Provide addtional lifering in order to comply with 46 CFR 180.70. Vessel must have a total of three, of which one must be fitted with a waterlight and one must be fitted with line, as provided for in 46 CFR. Current arrangement of two, even with additional ring(s) on tug, is insufficient.
Condition: Unknown
Due 11 September 1998
Resolved 11 September 1998

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.