Inspection history · 48
25 March 2026
Vessel Attendance · Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8319267
2 October 2025
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8243497
16 September 2024
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8024733
2 July 2024
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7944468
5 October 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7784992
24 August 2022
COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7524644
14 September 2021
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7291579
31 March 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7150742
19 November 2020
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7098517
9 September 2020
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7049247
10 July 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6741963
6 November 2018
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6565811
11 June 2018
Spot Check
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6442272
3 August 2017
COI Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6229434
23 August 2016
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5963447
7 April 2016
Administrative Inspection · Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5824762
22 September 2015
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5725327
29 July 2014
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4930314
2 May 2014
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4848784
21 November 2013
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4756908
7 November 2013
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4744087
31 July 2012
COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4396650
8 November 2011
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4166447
19 July 2011
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4087390
21 October 2010
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3874735
16 July 2009
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3536503
16 July 2008
Administrative Inspection · DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3262820
6 September 2007
Administrative Inspection · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3049647
5 December 2006
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2834251
6 October 2006
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2794985
7 August 2006
Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2739459
1 December 2005
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2536659
16 November 2005
Annual Inspection · Administrative Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2527123
16 November 2004
Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2241978
15 September 2004
Annual Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2196620
23 September 2003
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1901503
3 October 2002
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1684015
17 September 2002
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1674348
15 January 2002
Hull Examination · Internal Structural Exam
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1478602
20 November 2001
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1076726
13 November 2001
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1376800
31 July 2001
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1075205
12 October 2000
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1424997
23 September 1999
COI Inspection · Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1402965
7 October 1998
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1378478
11 September 1998
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 800013
7 October 1997
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1409762
26 September 1996
Hull Examination · Deadweight Survey · Initial Certification · Plan Review "T" Boat
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1435748
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 November 2018
Resolved
46 CFR 180.71(e) requires PFDs required to marked IAW 46 CFR 185.604 (with vessel's name). Five PFDs not properly marked with vessel name.
Action required: 10 - Deficiency Rectified
Resolved 6 November 2018
Resolution: PFDs properly marked with vessel's name by the end of the inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 November 2018
Resolved
One of the three required life rings found with water intrusion into body of life ring compromising flotation.
Action required: 10 - Deficiency Rectified
Resolved 6 November 2018
Resolution: New ring life buoy properly stenciled and placed on board vessel.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 6 November 2018
Resolved
Spanner wrench required to be located with each fire hose. The vessel had two fire hoses and no spanner wrenches on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 December 2018
Resolved 11 December 2018
Resolution: New wrenches placed on board vessel.
Lifesaving › Lifebuoys › Serviceable
Issued 23 August 2016
Resolved
1 of the 3 ring life buoys required to be on board the vessel by 46 CFR 180.70 deemed to be "heavy" due to water logged interior material. Buoy removed from service due to the apparent loss of buoyancy and required to be replaced.
Action required: 705 - Other - as specified
Due 23 August 2016
Resolved 23 August 2016
Resolution: Ring life buoy replaced with approved and properly marked equipment.
Engineering › Bilge Water Management System › Strainer
Issued 7 April 2016
Resolved
Bilge suction strainers as required by 46 CFR 182.510 in the #2 and #9 voids require repair/replacement due to wastage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 27 April 2016
Resolution: Two new strainers properly installed.
Fire Fighting › Fire Main › Valves
Issued 28 August 2012
Resolved
The overboard discharge valve on the fire pump in the vicinity of void #9 leaked, water was bypassing valve gate.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 September 2012
Resolved 25 September 2012
Resolution: Witnessed installed new valve and proper operation.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 16 July 2008
Resolved
Casing for strobe light cracked.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2008
Resolution: New waterlight installed
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 16 July 2008
Resolved
Draft Marks not contrasting color to hull.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2008
Resolution: Draft marks painted
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 7 August 2006
Resolved
strongbacks on hatches for #1, 2, 3 and 4 voids are wasted and need replaced.
Condition: Unknown
Due 8 September 2006
Resolved 18 October 2006
Resolution: Witnessed new gaskets.
Lifesaving › Lifebuoys › Serviceable
Issued 16 November 2005
Resolved
Renew two (x2) life ring buoys. Two life ring buoys are cracking along the center seem.
Action required: 705 - Other - as specified
Due 1 December 2005
Resolved 1 December 2005
Accommodation/Occupational Safety › Occupational Safety
Issued 17 September 2002
Resolved
Properly install machinery guards for exposed pulleys and belts of engine aboard UTV CALHOUN LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Unknown
Due 17 October 2002
Resolved 3 October 2002
Navigation
Issued 13 November 2001
Resolved
PROPERLY INSTALL ALL WIRE ROPE CLIPS ON STEERING CABLE AND HOOK RELEASE.
Condition: Unknown
Due 13 November 2001
Resolved 13 November 2001
Construction/Loadline
Issued 13 November 2001
Resolved
PROVE PROPER OPERATION OF #1 THROUGH #9 BILGE PUMPS, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 13 November 2001
Resolved 13 November 2001
Lifesaving
Issued 13 November 2001
Resolved
REPLACE PORT AND STARBOARD LIFE RING
Condition: Unknown
Due 13 November 2001
Resolved 13 November 2001
Lifesaving
Issued 13 November 2001
Resolved
POST NO SMOKING SIGNS
Condition: Unknown
Due 13 November 2001
Resolved 13 November 2001
Lifesaving
Issued 13 November 2001
Resolved
REPAIR OR REPLACE FLOAT LIGHT
Condition: Unknown
Due 13 November 2001
Resolved 13 November 2001
Fire Fighting
Issued 13 November 2001
Resolved
REPLACE LENS ON FIRE PUMP GAUGE
Condition: Unknown
Due 13 November 2001
Resolved 13 November 2001
Navigation
Issued 13 November 2001
Resolved
REPAIR OR REPLACE STARBOARD RUNNING LIGHT.
Condition: Unknown
Due 13 November 2001
Resolved 13 November 2001
Construction/Loadline
Issued 13 November 2001
Resolved
REPAINT DRAFT MARKINGS ON HULL
Condition: Unknown
Due 13 November 2001
Resolved 13 November 2001
Navigation
Issued 13 November 2001
Resolved
PLACE GUARD OVER STEERING GEAR CABLES
Condition: Unknown
Due 13 November 2001
Resolved 13 November 2001
Construction/Loadline
Issued 23 September 1999
Resolved
Bilge system was not operational due to a faulty valve. Owners stated they only work valves during CG inspections once a year. Recommended that all bilge system valves be operated monthly to ensure proper operation.
Condition: Unknown
Due 7 October 1999
Resolved 7 October 1999
Engineering
Issued 23 September 1999
Resolved
Stop main diesel engine oil leaks on M/V Calhoun.
Condition: Unknown
Due 7 October 1999
Resolved 7 October 1999
Lifesaving
Issued 11 September 1998
Resolved
Provide addtional lifering in order to comply with 46 CFR 180.70. Vessel must have a total of three, of which one must be fitted with a waterlight and one must be fitted with line, as provided for in 46 CFR. Current arrangement of two, even with additional ring(s) on tug, is insufficient.
Condition: Unknown
Due 11 September 1998
Resolved 11 September 1998