MAURY USCG vessel records Sign in
← All vessels

OLYMPIC LEGACY

OLYMPIC LEGACY is a 1995 tank ship. The Coast Guard has recorded 14 inspections since 1996, most recently in July 2009, along with 1 deficiency.

Records from 1996 to 2009. Most recent: inspection, 30 July 2009.

Built
1995
Last inspected
30 July 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9088689 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
439271
Flag
GREECE
—
Maury page id
psix-439271

Inspections, by type

…with no type recorded7
Years with a record 13 calendar years (1996–2009)
The 14 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it160129 - Regulatory (Subpart C or D), Gross Ton
95283 - Regulatory (Subpart C or D), Net Ton
302287 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CAPTAIN FAYRA Passenger (Inspected) · MISLE 46718 · 26 August 1998 · activity 105407

Inspection history · 14

30 July 2009 ISPS II Exam · COC-TVE Renew · PII Safety Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3550337
1 April 2008 ISPS II Exam · COC-TVE Annual
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3172435
22 March 2007 ISPS II Exam · COC-TVE Renew · Ballast Water Examination · Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2893126
14 April 2005 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2333121
13 December 2004 COC-TVE Renew · ISPS II Exam
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2258465
30 July 2003 Annual Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1880766
11 June 2002 Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1629053
5 July 2001 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 291543
17 August 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 281511
5 June 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 429397
26 August 1998 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 105407
12 October 1997 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 408926
12 October 1997 Tank Vessel Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 776989
28 April 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 390289

Deficiency record · 1

Deck/Cargo › Inert Gas System › IGS Scrubber
Issued 22 March 2007 Resolved
During IG shut down tests sew water pump was energized with inlet valve to scrubber closed. Valve hosing was fractured from the water pressure and IG system no longer useable. Vessel can not conduct cargo operations until deficiency has been rectified.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 March 2007
Resolved 22 March 2007
Resolution: Vessel made repairs to the satisfaction of class.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.