MAURY USCG vessel records Sign in
← All vessels

CAPTAIN BILL

CAPTAIN BILL is a 1960 passenger vessel (inspected). The Coast Guard has recorded 27 inspections since 1984, most recently in May 1996, along with 13 deficiencies.

Records from 1984 to 1996. Most recent: inspection, 28 May 1996.

Built
1960
Last inspected
28 May 1996
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WP7533
Flag
UNITED STATES
—
Maury page id
psix-43932

Inspections, by type

…with no type recorded4
Years with a record 13 calendar years (1984–1996)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 30 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it26 - Regulatory (Subpart C or D), Net Ton
39 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 27

28 May 1996 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1085335
14 September 1995 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 872070
9 November 1994 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1173218
28 October 1994 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1178016
13 September 1994 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1172778
14 September 1993 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 838078
30 October 1992 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1264126
15 September 1992 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 949766
28 February 1992 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 956834
7 October 1991 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1251545
20 September 1991 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1245176
15 October 1990 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 906744
17 September 1990 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 911384
18 November 1989 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 896107
11 October 1989 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 918508
19 September 1989 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1039349
18 November 1988 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1207328
20 September 1988 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1042741
12 November 1987 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1329548
22 September 1987 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1005003
24 November 1986 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1330805
23 September 1986 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1006415
25 April 1986 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1306472
25 April 1986 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1306486
15 October 1985 Credit Drydock
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 991693
24 September 1985 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1299252
23 October 1984 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 976346

Deficiency record · 13

Construction/Loadline
Issued 28 October 1994 Resolved
PROVE ALL EXTERIOR DECK HATCHES ARE WATERTIGHT.
Condition: Unknown
Due 28 October 1994
Resolved 28 October 1994
Engineering
Issued 28 October 1994 Resolved
REPAIR EMERGENCY FUEL SHUTOFF VALVE REACH ROD.
Condition: Unknown
Due 28 October 1994
Resolved 28 October 1994
Documentation
Issued 28 October 1994 Resolved
PROVE VESSEL HAS A VALID FCC STATION LICENSE.
Condition: Unknown
Due 28 October 1994
Resolved 28 October 1994
Construction/Loadline
Issued 13 September 1994 Resolved
REPLACE THE GASKETS ON ALL WATERTIGHT HATCHES ON THE MAIN DECK.
Condition: Unknown
Due 13 September 1994
Resolved 13 September 1994
Construction/Loadline
Issued 13 September 1994 Resolved
REPLACE THE FORWARD 2 WATERTIGHT HATCHES ON THE MAIN DECK.
Condition: Unknown
Due 13 September 1994
Resolved 13 September 1994
Fire Fighting
Issued 13 September 1994 Resolved
REPAIR OR REPLACE THE REACH ROD FOR THE FIRE/BILGE PUMP DISCHARGE VALVE.
Condition: Unknown
Due 13 September 1994
Resolved 13 September 1994
Lifesaving
Issued 17 September 1990 Resolved
REPLACE 9 ADULT PFD'S TOTAL PERSON ALLOWED REDUCED TO 64 UNTIL THIS ITEM IS CORRECTED
Condition: Unknown
Due 17 September 1990
Resolved 17 September 1990
Construction/Loadline
Issued 18 November 1988 Resolved
MAKE PERMANENT REPAIRS TO MAIN DECK ABOVE #2 &#3 COMPARTMENTS
Condition: Unknown
Due 18 November 1988
Resolved 18 November 1988
Lifesaving
Issued 20 September 1988 Resolved
PROVIDE WEAK LINK OF PROPER SIZE FOR FORWARD BUOYANT APPARATUS.
Condition: Unknown
Due 20 September 1988
Resolved 20 September 1988
Lifesaving
Issued 20 September 1988 Resolved
PROVIDE 4 ADDITIONAL LIFEJACKETS.
Condition: Unknown
Due 20 September 1988
Resolved 20 September 1988
Navigation
Issued 20 September 1988 Resolved
PROVIDE UP-TO-DATE CHARTS AND PUBLICATIONS IN ACCORDANCE WITH 46 CFR 185.20-35.
Condition: Unknown
Due 20 September 1988
Resolved 20 September 1988
Construction/Loadline
Issued 20 September 1988 Resolved
CROP AND RE-NEW LOWER 6 INCHES OF ANGLE STIFFENERS ON INSIDE FORWARD BULKHEAD OF LAZARETTE.
Condition: Unknown
Due 20 September 1988
Resolved 20 September 1988
Construction/Loadline
Issued 23 September 1986 Resolved
RENEW THE 2ND TRANSVERSE WEB FRAME IN THE NUMBER 2 VOID AT THE VESSEL'S NEXT DRYDOCK, BUT ANY CASE NO LATER THAN 30 APRIL 1987.
Condition: Unknown
Due 23 September 1986
Resolved 23 September 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.