MAURY USCG vessel records Sign in
← All vessels

MISSION BELLE

MISSION BELLE is a 1960 passenger vessel (inspected). The Coast Guard has recorded 72 inspections since 1984, most recently in February 2026, along with 204 deficiencies and 3 casualty investigations between 2010 and 2023.

Records from 1984 to 2026. Most recent: inspection, 23 February 2026.

Built
1960
Last inspected
23 February 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD7009
Flag
UNITED STATES
—
Maury page id
psix-43933

Inspections, by type

…with no type recorded5
Years with a record 40 calendar years (1984–2026)
The 72 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)57.4 ft × 20.0 ft × 5.2 ft
Registered tonnagegross 39 / net 26
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGEORGE W SUTTON · HUNTINGTON BEACH, CA, UNITED STATES · built 1960
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 27 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it39 - Regulatory (Subpart C or D), Gross Ton
26 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCX2453MMSI not assigned · expired · compulsorily equipped · granted 30 January 1997, cancelled 7 April 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 72

23 February 2026 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8314409
3 April 2025 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8104485
9 December 2024 Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8045292
11 April 2024 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7893534
10 June 2023 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7791870
9 June 2023 Damage Survey · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7712994
8 March 2023 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7642936
27 December 2022 Internal Structural Exam · In-Service Inspection · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7627704
5 May 2022 Administrative Inspection · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7444793
20 April 2021 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7178954
17 December 2020 Hull Examination · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7113207
13 April 2020 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6934337
21 October 2019 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6839010
13 March 2019 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6641769
8 January 2019 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6607218
6 March 2018 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6364162
23 June 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6184762
12 April 2017 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6122825
20 January 2017 Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6073979
20 June 2016 Annual Inspection · Construction Oversight · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5913254
15 February 2012 Plan Review "T" Boat
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4245306
19 January 2011 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3928964
24 March 2010 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3696670
16 April 2009 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3443529
19 November 2008 Deficiency Check · Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3364624
31 January 2008 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3137903
17 April 2007 Deficiency Check · Annual Inspection · Simplified Stability Test
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2905374
4 April 2006 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2601782
10 March 2005 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2297088
19 November 2004 Deficiency Check · Examination of Repairs · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2244600
5 February 2004 Annual Inspection · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1964488
9 January 2003 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1727124
11 December 2002 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1717671
5 February 2002 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1484180
29 January 2002 Administrative Inspection
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1482485
2 January 2002 Deficiency Check · Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1474748
1 February 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1459663
8 January 2001 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1399516
3 March 2000 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 143788
16 December 1999 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1372877
29 June 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1424974
2 March 1999 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1458605
22 December 1998 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1368992
23 January 1998 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1110323
18 December 1997 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 783504
14 March 1997 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1371721
17 December 1996 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1368022
29 January 1996 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1467915
22 December 1995 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1357430
6 December 1994 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1400110
10 December 1993 Hull Examination · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1366931
30 November 1992 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1140005
18 August 1992 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 940619
25 February 1992 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 952025
3 December 1991 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 940267
3 December 1990 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1216903
2 November 1990 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1234863
4 May 1990 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1226770
28 November 1989 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1237974
27 November 1989 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1236104
12 May 1989 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 888723
23 November 1988 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 893570
16 November 1988 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 893455
7 December 1987 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1308687
15 September 1987 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1317613
30 December 1986 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1000308
25 June 1986 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 996641
15 April 1986 Credit Drydock
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 999033
4 March 1986 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 985782
26 December 1985 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 993508
18 December 1985 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 994718
14 December 1984 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 977159

Deficiency record · 204

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 June 2023 Resolved
On 10JUN2023 Vessel reported a loss of steering / maneuverability. Vessel must be provided with a main steering gear that is of adequate strength and capable of steering the vessel at all service speeds and be capable of moving the rudder from 35 degrees on one side to 30 degrees on the other side in not more than 28 seconds with the vessel moving ahead at maximum service speed. Vessel must troubleshoot and identify the cause of the loss of steering, submit a report attesting to the cause as well as satisfactory operation of the propulsion and steering system and make the vessel available for inspection to the local OCMI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2023
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 8 March 2023 Resolved
All drills and EPIRB tests must be conducted and logged as required by regulations. Last drill and EPIRB test were logged in August 2022. Must conduct EPIRB tests on monthly basis and required drills on quarterly basis and logged.
Action required: 10 - Deficiency Rectified
Resolved 8 March 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 March 2023 Resolved
Child size life jackets equal to at least 10% of the number of persons permitted on board must be provided. Five (05) child size life jackets present for exam and six (06) child size life jackets required by COI. Must add one (01) child size life jacket.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 April 2023
Resolved 9 March 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 May 2022 Resolved
Engine room electrical panel enclosure not properly sealed; found 2 inch hole in right side of panel. Repair.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2022
Resolved 20 May 2022
Resolution: Corrected by installing knock-out seal hardware; Operator forwarded Photo of repair made.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 20 April 2021 Resolved
Vessel has multiple radio installations, provide VHF DSC enabled radio with labeling of "Distress Radio".
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2021
Resolved 6 May 2021
Resolution: Received photo of labeled radio.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 20 April 2021 Resolved
Repair damaged coating on 02 life floats IAW manufactures repair procedures.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2021
Resolved 6 May 2021
Resolution: Vessel rep emailed photo's of repaired life floats.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 20 April 2021 Resolved
Make proper adjustment to both shaft seals. STBD was found leaking and port seal was found misaligned.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2021
Resolved 6 May 2021
Resolution: Vessel's [name withheld] emailed statement attesting to completed adjustments and also sent video of properly operating shaft seals.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 April 2021 Resolved
The stbd main engine exhaust was found with temporary repairs made to it. Remove epoxy and make permanent repairs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2021
Resolved 6 May 2021
Resolution: Vessel rep emailed photo of exhaust pipe that was re-welded.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 April 2021 Resolved
Installed galley hot water heater was found plugged into a power strip. Remove power strip located in galley, provide permanent outlet/box.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2021
Resolved 6 May 2021
Resolution: Vessel rep provided photo of removed power strip and hot water heater plugged into a receptacle.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 April 2021 Resolved
Accommodation compartment fire extinguisher was found with an inoperable mounting bracket. Provide accommodation space fire extinguisher with approved / proper mounting bracket.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2021
Resolved 6 May 2021
Resolution: Vessel rep emailed photo of new bracket installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 April 2020 Resolved
Close opening found on shore power switch.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2020
Resolved 20 April 2020
Resolution: Received picture, all SAT.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 13 April 2020 Resolved
Input MMSI/GPS into VHF-DSC radio.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2020
Resolved 20 April 2020
Resolution: Received picture proof of inputs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 13 April 2020 Resolved
Install new window for broken window stbd side on bridge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2020
Resolved 20 April 2020
Resolution: Received picture of new window installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 March 2019 Resolved
Renew wasted ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 April 2019
Resolved 13 March 2019
Electrical › Electric Generation Source (service) › Generator
Issued 23 June 2017 Resolved
Diagnose and repair loss of generator power.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 July 2017
Fire Fighting › Ventilation Systems › Ducts
Issued 12 April 2017 Resolved
Provide vent closure for engine room vent supply and exhaust.
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 27 April 2017
Engineering › Sea-water System (primary cooling) › Piping
Issued 12 April 2017 Resolved
Permantely mount heat exchanger on generator.
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 27 April 2017
Engineering › Sea-water System (primary cooling) › Piping
Issued 12 April 2017 Resolved
Cap pipe in forward engine room from overhead.
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 27 April 2017
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 7 July 2016 Resolved
Prove proper operation of the HF radio.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 7 August 2016
Resolution: Conducted radio check
Lifesaving › Lifefloat › Serviceable
Issued 7 July 2016 Resolved
Make repairs to upper life float.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 August 2016
Resolved 3 August 2016
Resolution: Made repairs to upper life float
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 7 July 2016 Resolved
Install shaft guard on bilge pump
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 August 2016
Resolved 3 August 2016
Resolution: Installed guard on pump shaft
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 7 July 2016 Resolved
Provide 02 child sized life jackets onboard
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 7 July 2016
Resolution: Fixed on the spot
Lifesaving › Lifefloat › Float-free Link
Issued 7 July 2016 Resolved
Provide USCG approved weak link for forward life float
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 7 July 2016
Resolution: Fixed on the spot.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 24 March 2010 Resolved
Remove/Clean oil throughout engineroom (engines, overhead, bulkheads, etc.) make ready for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 March 2010
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (air intake)
Issued 24 March 2010 Resolved
Renew all soft hoses throughout generator coolant and saltwater systems.
Due 24 April 2010
Resolved 12 April 2010
Engineering › Diesel Engine (propulsion-direct drive) › Piping (air intake)
Issued 24 March 2010 Resolved
Renew all soft hoses throughout port Main engine coolant and saltwater systems
Due 24 April 2010
Resolved 21 April 2010
Engineering › Diesel Engine (propulsion-direct drive) › Piping (air intake)
Issued 24 March 2010 Resolved
Renew all soft hoses throughout starboard Main engine coolant and saltwater systems
Due 24 April 2010
Resolved 21 April 2010
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 March 2010 Resolved
Install guard around generator pulleys
Due 24 April 2010
Resolved 21 April 2010
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Governor
Issued 24 March 2010 Resolved
Properly connect rod from solenoid to governor on generator
Due 24 April 2010
Resolved 26 March 2010
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 24 March 2010 Resolved
Renew packing to transducer.
Due 24 April 2010
Resolved 12 April 2010
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 24 March 2010 Resolved
Remove excessive spare lube oil from engineroom
Due 24 April 2010
Resolved 26 March 2010
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 24 March 2010 Resolved
Remove excessive spare hydraulic oil from engineroom
Due 24 April 2010
Resolved 26 March 2010
Engineering › Steering Gear System › Power Unit
Issued 24 March 2010 Resolved
Properly cap hydraulic tank fill
Due 24 April 2010
Resolved 26 March 2010
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 24 March 2010 Resolved
Install/replace missing bolt to generator exhaust manifold
Due 24 April 2010
Resolved 26 March 2010
Engineering › Steering Gear System › Power Unit
Issued 24 March 2010 Resolved
Repair hydraulic leak at teh filter
Due 24 April 2010
Resolved 26 March 2010
Engineering › Fuel Oil Service System › Hose
Issued 24 March 2010 Resolved
Renew fuel oil return hose from generator
Due 24 April 2010
Resolved 26 March 2010
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Bedplate
Issued 24 March 2010 Resolved
Renew generator forward engine mounts
Due 24 April 2010
Resolved 12 May 2010
Engineering › Diesel Engine (propulsion-direct drive) › Piping (air intake)
Issued 24 March 2010 Resolved
Renew starboard main engine salt water cross over tube
Due 24 April 2010
Resolved 21 April 2010
Electrical › Electrical Distribution System (service) › Junction Box
Issued 24 March 2010 Resolved
Renew junction box on top of the pilot house
Due 24 April 2010
Resolved 26 March 2010
Electrical › Electrical Distribution System (service) › Junction Box
Issued 24 March 2010 Resolved
Properly seal junction box for mast head light
Due 24 April 2010
Resolved 26 March 2010
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 24 March 2010 Resolved
Properly secure port main engine exhaust in way of #5 void
Due 24 April 2010
Resolved 26 March 2010
Electrical › Lighting (service) › Lighting Fixture
Issued 24 March 2010 Resolved
Install cover over light leading to the engineroom
Due 24 April 2010
Resolved 26 March 2010
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 March 2010 Resolved
Properly secure wiring to bait tank pump at the junction box
Due 24 April 2010
Resolved 26 March 2010
Electrical › Electrical Distribution System (service) › Cable
Issued 24 March 2010 Resolved
Properly secure wiring from shore tie connection leading to engineroom
Due 24 April 2010
Resolved 26 March 2010
Navigation › Piloting/Steering › Magnetic Compass
Issued 24 March 2010 Resolved
Repair/install compass light
Due 24 April 2010
Resolved 26 March 2010
Engineering › Bilge Water Management System › Piping
Issued 24 March 2010 Resolved
Install skin valve to the bilge piping at the overboard penetration
Due 24 April 2010
Resolved 26 March 2010
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 March 2010 Resolved
Remove dead end wires in the engineroom overhead above generator
Due 24 April 2010
Resolved 21 April 2010
Engineering › Bilge Water Management System › Manifold
Issued 24 March 2010 Resolved
Properly label bilge system manifold
Due 24 April 2010
Resolved 26 March 2010
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 24 March 2010 Resolved
Repair/replace single side band radio
Due 24 April 2010
Resolved 12 May 2010
Lifesaving › Lifefloat › Float-free Link
Issued 16 April 2009 Resolved
Provide lifefloat weaklink with ID tag for lifefloat stowed on top of house.
Action required: 705 - Other - as specified
Due 5 May 2009
Resolved 6 May 2009
Lifesaving › Lifefloat › Serviceable
Issued 16 April 2009 Resolved
Repair/replace two lifefloats stowed behind the pilot house.
Action required: 705 - Other - as specified
Due 5 May 2009
Resolved 6 May 2009
Construction/Loadline › Hull › Bottom Plating
Issued 24 November 2008 Resolved
Crop and renew additional wasted hull plate areas identified on gaging report.
Action required: 705 - Other - as specified
Due 1 January 2009
Resolved 28 January 2009
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 19 November 2008 Resolved
Crop and renew stbd side fwd E/R bulkhead where wasted/holed (where bulkhead meets hull plate).
Action required: 705 - Other - as specified
Due 1 January 2009
Resolved 28 January 2009
Engineering › Steering Gear System › Rudder
Issued 19 November 2008 Resolved
Submit repair proposal and affect permanent repair to crack in port rudder (at rudder stock).
Action required: 705 - Other - as specified
Due 1 January 2009
Resolved 28 January 2009
Construction/Loadline › Hull › Hull Plating
Issued 19 November 2008 Resolved
Crop and renew hull plating IWO four (4) holes on port side, as identified and marked.
Action required: 705 - Other - as specified
Due 1 January 2009
Resolved 28 January 2009
Construction/Loadline › Penetrations › Pipe Flange
Issued 19 November 2008 Resolved
Repair/renew or remove old tranducer (port side aft).
Action required: 705 - Other - as specified
Due 1 January 2009
Resolved 28 January 2009
Engineering › Bilge Water Management System › Strainer
Issued 19 November 2008 Resolved
Clean or replace all bilge foot strainers for bilge system (all spaces).
Action required: 705 - Other - as specified
Due 1 January 2009
Resolved 28 January 2009
Construction/Loadline › Hull › Bottom Plating
Issued 19 November 2008 Resolved
Conduct belt gaging of hull plating from waterline to waterline at six-foot intervals from stem to stern, and provide gaging report to inspector for evaluation.
Action required: 705 - Other - as specified
Due 1 January 2009
Resolved 28 January 2009
Lifesaving › Lifefloat › Pendant
Issued 31 January 2008 Resolved
Renew pendants & hand grab lines on 12 person lifefloat. Vessel restricted to 42 persons (37 pax) until corrected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2008
Resolved 31 January 2008
Lifesaving › Lifefloat › Painter
Issued 31 January 2008 Resolved
Renew worn float light lanyard to 1 of the 22 person lifefloats.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 February 2008
Resolved 31 January 2008
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 31 January 2008 Resolved
Replace wasted captive chain to void #2 hatch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 February 2008
Resolved 12 February 2008
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 31 January 2008 Resolved
Propose plan for and affect repair to forepeak hatch dog-lip.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2009
Resolved 28 January 2009
Electrical › Electrical Distribution System (service) › Panelboard
Issued 31 January 2008 Resolved
Provide new cover for cracked volt/amp meter box in engine space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2008
Resolved 22 February 2008
Resolution: Installed new cover.
Electrical › Electrical Distribution System (service) › Cable
Issued 31 January 2008 Resolved
Repair/replace battery cable where cover is torn.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2008
Resolved 12 February 2008
Electrical › Electric Generation Source (service) › Generator
Issued 31 January 2008 Resolved
Clean excessive oil/grease from generator including windings.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 February 2008
Resolved 12 February 2008
Engineering › Bilge Water Management System › Piping
Issued 31 January 2008 Resolved
Provide support for bilge piping running from pump to overboard discharge valve.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 February 2008
Resolved 12 February 2008
Engineering › Bilge Water Management System › Piping
Issued 31 January 2008 Resolved
Provide plan for replacing flex hose in bilge piping between pump & overboard discharge valve.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 12 February 2008
Engineering › Bilge Water Management System › Hose
Issued 31 January 2008 Resolved
Double-clamp all flex-hose runs to bilge feet.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 February 2008
Resolved 12 February 2008
Construction/Loadline › Hull › Bracket
Issued 31 January 2008 Resolved
Propose plan for, and affect repair (renew) to wasted knee IWO void #2, 1st frame starboard aft of forepeak bulkhead.
Action required: 705 - Other - as specified
Due 31 January 2009
Resolved 28 January 2009
Construction/Loadline › Structures › Transverse Bulkhead
Issued 31 January 2008 Resolved
Propose plan for, & affect renewal of 2 wasted vertical frames on forward bulkhead of void #4.
Action required: 705 - Other - as specified
Due 31 January 2009
Resolved 28 January 2009
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 April 2007 Resolved
Vessel is restricted from operating with passengers until satisfactory completion of an annual COI inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 April 2007
Resolved 17 April 2007
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 17 April 2007 Resolved
Replace/renew cracked watertight hatch on #1 void (forepeak). Vessel restricted fm operating until corrected.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 April 2007
Resolved 20 April 2007
Resolution: New hatch installed.
Deck/Cargo › Holds/Tanks › Scuttle
Issued 17 April 2007 Resolved
Replace improper deck scuttle (cover) on starboard fuel shut-off. Vessel restricted fm operating until correct.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 April 2007
Resolved 20 April 2007
Resolution: Proper cover installed.
Lifesaving › Lifefloat › Painter
Issued 17 April 2007 Resolved
Repair/replace liferaft painter canister to permit free run of line as designed (behind pilothouse).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 April 2007
Resolved 20 April 2007
Lifesaving › Lifefloat › Retroreflective Material
Issued 17 April 2007 Resolved
Renew retroreflective tape on lifefloat on top of wheelhouse.
Action required: 705 - Other - as specified
Due 17 May 2007
Resolved 20 April 2007
Lifesaving › Lifefloat › Paddle
Issued 17 April 2007 Resolved
Mark & attach 2 paddles to lifefloat on top of pilothouse.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2007
Resolved 20 April 2007
Lifesaving › Lifefloat › Paddle
Issued 17 April 2007 Resolved
Replace broken paddle and attach 2 paddles to each of lifefloats behind pilothouse.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2007
Resolved 20 April 2007
Construction/Loadline › Structures › Transverse Bulkhead
Issued 17 April 2007 Resolved
Seal stuffing tube between engine space & void void forward of engine space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2007
Resolved 17 May 2007
Communications › Audible Communications › Bell
Issued 17 April 2007 Resolved
Provide bell of proper size (>/=20 mm).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 April 2007
Resolved 20 April 2007
Communications › Audible Communications › Horn/Whistle
Issued 17 April 2007 Resolved
Renew air horn.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 April 2007
Resolved 20 April 2007
Engineering › Generator (propulsion/auxiliary-electric) › Winding
Issued 17 April 2007 Resolved
Clean generator, including windings, fix selenoid, & find/fix leaks on same.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2007
Resolved 17 May 2007
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 17 April 2007 Resolved
Prove existing fuel return hoses on engines meet SAE-J1942 or replace with SAE J1942 hose or hard pipe IAW 46CFR182.455.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2007
Resolved 19 June 2007
Resolution: Owner replaced flexible hose w/ annealed copper tubing IAW 46 CFR 182.455.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 17 April 2007 Resolved
Repair leak in port fuel system return line junction.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2007
Resolved 17 May 2007
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 17 April 2007 Resolved
Provide up-to-date charts & publications (CG Light List, U.S. Coast Pilot [name withheld], and NAVRULS) for areas vessel transits.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2007
Resolved 20 April 2007
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 17 April 2007 Resolved
Provide 5 additional serviceable adult Type I PFDs with lights for full 55 person capacity.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 April 2007
Resolved 20 April 2007
Electrical › Electrical Distribution System (service) › Panelboard
Issued 4 April 2006 Resolved
Fill dead space in distribution panel in engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 April 2006
Resolved 14 April 2006
Engineering › Diesel Engine (propulsion-electric) › Piping (exhaust)
Issued 4 April 2006 Resolved
Properly mount and support generator exhaust.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 April 2006
Resolved 14 April 2006
Communications › Radio Communications › EPIRB
Issued 4 April 2006 Resolved
Provide hydrostatic release and bracket for EPIRB. Vessel limited to within 3 nms of operation until deficiency is cleared.
Action required: 705 - Other - as specified
Due 14 April 2006
Resolved 14 April 2006
Construction/Loadline › Hull › Stringer
Issued 4 April 2006 Resolved
Crop and renew 1 stringer most aft on stbd side and 2 stringers most aft on port side in head space. Deficiency to be cleared in December 06 drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 December 2006
Resolved 10 January 2007
Resolution: Stringers repaired.
Documentation › Logs/Records › Drug Test Records
Issued 4 April 2006 Resolved
Provide complete drug testing report for 2005/2006.
Action required: 705 - Other - as specified
Due 14 April 2006
Resolved 14 April 2006
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Injector (fuel injection)
Issued 4 April 2006 Resolved
Properly support return fuel line above generator.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 April 2006
Resolved 14 April 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Injector (fuel injection)
Issued 4 April 2006 Resolved
Stop fuel drips around connectors on fuel return line above generator.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 April 2006
Resolved 14 April 2006
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 4 April 2006 Resolved
Provide guards on fans in head space and fore peak.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 14 April 2006
Resolved 14 April 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 4 April 2006 Resolved
Replace expired items in first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2006
Resolved 14 April 2006
Communications › Alarms/Indicators › Bilge Alarm
Issued 4 April 2006 Resolved
Repair high water bilge alarms in #4 and #3 compartments.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2006
Resolved 14 April 2006
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 10 March 2005 Resolved
Re-new safety radio certificate.
Action required: 705 - Other - as specified
Due 10 April 2005
Resolved 30 March 2005
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 10 March 2005 Resolved
Replace plastic trash cans in engine room.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 April 2005
Resolved 30 March 2005
Electrical › Electric Supply System (service) › Battery Charger
Issued 10 March 2005 Resolved
Hardwire battery charger.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 April 2005
Resolved 30 March 2005
Lifesaving › Lifeboat Equipment › Oar
Issued 10 March 2005 Resolved
Mark paddles with name of vessel in life float.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2005
Resolved 30 March 2005
Engineering › Fuel Oil Service System › Valve
Issued 10 March 2005 Resolved
Replace fuel return valve to generator.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 10 April 2005
Resolved 30 March 2005
Fire Fighting › Remote Fuel Shutoff › General
Issued 10 March 2005 Resolved
PMS both fuel shut-off valves.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2005
Resolved 30 March 2005
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 10 March 2005 Resolved
Procure line and desiginated PFD for the rescue swimmer in M.O.B. scenarios.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 April 2005
Resolved 30 March 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 19 November 2004 Resolved
Procure guards on all vent fans.
Condition: Improper Installation
Due 22 December 2004
Resolved 22 December 2004
Construction/Loadline › Penetrations › Weld
Issued 19 November 2004 Resolved
Seal around bulkhead penetrations in bait tank compartment and lazarrette.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 December 2004
Resolved 22 December 2004
Construction/Loadline › Structures › Transverse Bulkhead
Issued 19 November 2004 Resolved
Patch hole in bulkhead in head compartment.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 December 2004
Resolved 22 December 2004
Construction/Loadline › Structures › Transverse Bulkhead
Issued 19 November 2004 Resolved
Repair deck frame in storage compartment port side.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 December 2004
Resolved 22 December 2004
Construction/Loadline › Structures › Manhole
Issued 19 November 2004 Resolved
Replace hatch chain in forepeak.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 December 2004
Resolved 22 December 2004
Construction/Loadline › Structures › Transverse Bulkhead
Issued 19 November 2004 Resolved
Submit permanent repair proposals to renew wasted bulkhead deck between engine room and head compartment. Until permanent repairs are made in 2006 drydock, vessel is restricted to a limited coastwise route w/i 20 miles of a harbor of safe refuge.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 December 2006
Resolved 31 January 2007
Resolution: Repair completed 1/31/07. Restriction lifted.
Electrical › Electric Generation Source (service) › Conductor
Issued 19 November 2004 Resolved
Clean generator windings.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 December 2004
Resolved 22 December 2004
Electrical › Electric Generation Source (service)
Issued 5 February 2004 Resolved
Clean generator windings IAW 46CFR183.200 LEGACY COMPONENT DESC: Generator
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2004
Resolved 19 February 2004
Electrical › Electrical Distribution System (service)
Issued 5 February 2004 Resolved
Provide suitable connections in a junction box for all ans and lights IAW 46CFR 183.340(i)(1) LEGACY COMPONENT DESC: Junction Box
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 March 2004
Resolved 4 March 2004
Electrical › Electrical Distribution System (service)
Issued 5 February 2004 Resolved
Provide metal supports not less than 2 feet apart on all overhead cable runs IAW 46cfr 183.340 (b)(4) LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 March 2004
Resolved 4 March 2004
Electrical › Electric Supply System (service)
Issued 5 February 2004 Resolved
Clean starting batteries IAW 46CFR 183.200 LEGACY COMPONENT DESC: Battery Installation
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2004
Resolved 19 February 2004
Electrical › Electric Supply System (service)
Issued 5 February 2004 Resolved
Secure battery box for generator IAW 46CFR 183.350(b) LEGACY COMPONENT DESC: Battery Installation
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 March 2004
Resolved 19 February 2004
Electrical › Electrical Distribution System (service)
Issued 5 February 2004 Resolved
Secure electrical panel cover IAW 46CFR183.330(b) LEGACY COMPONENT DESC: Distribution Panel Bus
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 March 2004
Resolved 19 February 2004
Electrical › Electric Generation Source (service)
Issued 5 February 2004 Resolved
Provide working Ammeter for generator IAW 46CFR183.320(c) LEGACY COMPONENT DESC: Panelboard
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2004
Resolved 19 February 2004
Engineering › Steering Gear System
Issued 5 February 2004 Resolved
Provide metallic supports for hydraulic cables in tank room IAW 46CFR182.200 LEGACY COMPONENT DESC: Bracket/Clamp
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 March 2004
Resolved 4 March 2004
Engineering › Bilge Water Management System
Issued 5 February 2004 Resolved
Remove pedro tubes(hoses) from bilge piping system and replace with metallic piping consistent with the existing system IAW 46CFR182.710 LEGACY COMPONENT DESC: Piping
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 March 2004
Resolved 19 February 2004
Lifesaving › Buoyant Apparatus
Issued 5 February 2004 Resolved
Replace grab lines around top life-float IAW 46CFR180.175(e)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2004
Resolved 19 February 2004
Lifesaving › Buoyant Apparatus
Issued 5 February 2004 Resolved
Repair cracks in top life-float IAW 46CFR 176.800
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 March 2004
Resolved 4 March 2004
Navigation › Piloting/Steering
Issued 5 February 2004 Resolved
Provide current light list, Coast Pilot, NavRules, and charts IAW 46CFR 184.420 LEGACY COMPONENT DESC: Coast Guard Light List
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2004
Resolved 19 February 2004
Operations/Management › Drills/Instruction
Issued 5 February 2004 Resolved
Provide ladder for MOB drill or suitable rescue boat IAW 46CFR 180.210(b) LEGACY COMPONENT DESC: Man Overboard Recovery
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 March 2004
Resolved 4 March 2004
Communications › Alarms/Indicators
Issued 5 February 2004 Resolved
Replace #1 Bilge alarm switch IAW 46CFR 183.200 LEGACY COMPONENT DESC: Bilge Alarm
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2004
Resolved 4 March 2004
Operations/Management › Pollution
Issued 9 January 2003 Resolved
No waste management program in place. IAW 33 CFR 151.57 LEGACY COMPONENT DESC: Removal Methods/Procedures
Due 23 January 2003
Resolved 10 January 2003
Resolution: Operator provided a WMP
Electrical › Mast
Issued 9 January 2003 Resolved
Mast head light in-op. IAW 46 CFR 183.420
Due 10 January 2003
Resolved 10 January 2003
Electrical › Lighting (service)
Issued 9 January 2003 Resolved
Compass light is in-op. IAW 46 CFR 184.402 LEGACY COMPONENT DESC: Lighting Fixture
Due 23 January 2003
Resolved 10 January 2003
Resolution: Witnessed operation of compass light
Navigation › Collision/Grounding Avoidance
Issued 9 January 2003 Resolved
Ships horn io-op. IAW 46 CFR 72 COLREGS
Due 10 January 2003
Resolved 10 January 2003
Lifesaving › Hand Flares
Issued 9 January 2003 Resolved
Must replace two red night flares. Current Exp. date 2002. IAW 46 CFR 180.68 (a)(1)(2)
Due 10 January 2003
Resolved 9 January 2003
Communications › Radio Communications › EPIRB
Issued 9 January 2003 Resolved
EPIRB in-op. Must provide operational EPIRB.
Due 10 January 2003
Resolved 10 January 2003
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 9 January 2003 Resolved
Must re-attach waterlight bracket near life rafts. IAW 46 CFR 180.175 (d)
Due 23 January 2003
Resolved 10 January 2003
Lifesaving › Buoyant Apparatus
Issued 9 January 2003 Resolved
Water light on ring buoy must be made operable. IAW 46 CFR180.70 (d) LEGACY COMPONENT DESC: Water light
Due 10 January 2003
Resolved 10 January 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 9 January 2003 Resolved
Provide all required fire extinguishers onboard. IAW 46 CFR 176.810
Due 10 January 2003
Resolved 10 January 2003
Engineering › Fuel Oil Storage/Transfer System
Issued 9 January 2003 Resolved
Must label remote emergency fuel valves and permanetly attach remote reach rod to valve handle on port side. IAW 46 CFR 185.608 LEGACY COMPONENT DESC: Valve
Due 23 January 2003
Resolved 10 January 2003
Resolution: Fuel valves properly labled.
Electrical › Electric Generation Source (emergency)
Issued 9 January 2003 Resolved
Generator windings need to be cleaned. IAW 46 CFR 183.200
Due 9 February 2003
Resolved 10 January 2003
Resolution: Verified that the windings were cleaned.
Engineering › Diesel Engine (auxiliary)
Issued 9 January 2003 Resolved
Generator needs to have fuel leaks cleaned up.
Due 23 January 2003
Resolved 10 January 2003
Resolution: Fuel leaks were repaired
Engineering › Sea-water System (primary cooling)
Issued 9 January 2003 Resolved
Must permanetly attach seachest strainer. LEGACY COMPONENT DESC: Sea Chest
Due 23 January 2003
Resolved 17 January 2003
Resolution: Verified proper mounting of the sea chest strainers.
Engineering
Issued 9 January 2003 Resolved
Must permanetly atach exhaust collector.
Due 23 January 2003
Resolved 17 January 2003
Resolution: Verified proper mounting of the exhaust collector
Accommodation/Occupational Safety › Occupational Safety
Issued 9 January 2003 Resolved
Attach ladder at entry point to Engine Room.
Due 23 January 2003
Resolved 17 January 2003
Resolution: Verified proper mounting of the Engine Room ladder
Accommodation/Occupational Safety › Occupational Safety
Issued 9 January 2003 Resolved
Attach ladder at entry point to Bridge.
Due 23 January 2003
Resolved 17 January 2003
Resolution: Verified proper mounting of the bridge access ladder.
Engineering › Bilge Water Management System
Issued 9 January 2003 Resolved
bildge manifold needs to be labled. LEGACY COMPONENT DESC: Manifold
Due 23 January 2003
Resolved 17 January 2003
Resolution: Bilge manifold was properly labled
Engineering › Sea-water System (primary cooling)
Issued 9 January 2003 Resolved
Secure salt water (PVC) line in Engineroom with metal clamps. LEGACY COMPONENT DESC: Piping
Due 23 January 2003
Resolved 17 January 2003
Resolution: PVC pipe was properly secured.
Documentation › Certificates/Documents
Issued 4 January 2002 Resolved
Post COI so its visable to passengers. LEGACY COMPONENT DESC: Certificate of Inspection
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 January 2002
Resolved 18 January 2002
Navigation › Collision/Grounding Avoidance
Issued 4 January 2002 Resolved
Clean navigation lights (remove paint from lens) LEGACY COMPONENT DESC: Navigation Lights
Condition: Unknown
Due 18 January 2002
Resolved 18 January 2002
Documentation › Logs/Records
Issued 4 January 2002 Resolved
Provide hydro expiration date for EPIRB. LEGACY COMPONENT DESC: Transfer Equipment Test/Inspection Records
Condition: Improper/Lack of Maintenance
Due 18 January 2002
Resolved 18 January 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 4 January 2002 Resolved
Replace expired items in first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Condition: Unknown
Due 18 January 2002
Resolved 18 January 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 4 January 2002 Resolved
[name withheld] storage with proper count. LEGACY COMPONENT DESC: Storage
Condition: Improper Installation
Due 18 January 2002
Resolved 18 January 2002
Pollution Prevention/Response › Prevention Equipment
Issued 4 January 2002 Resolved
Provide 30 X 30 mesh for fuel vents IAW 46 CFR 182.450 LEGACY COMPONENT DESC: Overfill Devices
Condition: Improper Installation
Due 18 January 2002
Resolved 18 January 2002
Electrical › Electrical Distribution System (service)
Issued 4 January 2002 Resolved
Engine room circuit breaker panel needs covers on open circuits. LEGACY COMPONENT DESC: Circuit Breaker
Condition: Unknown
Due 18 January 2002
Resolved 18 January 2002
Electrical › Electric Supply System (service)
Issued 4 January 2002 Resolved
Remove dead end wiring in engine room. LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Due 18 January 2002
Resolved 18 January 2002
Electrical › Lighting (service)
Issued 4 January 2002 Resolved
Remove un-used light fixture from lazerette. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper Installation
Due 18 January 2002
Resolved 18 January 2002
Engineering › Bilge Water Management System
Issued 4 January 2002 Resolved
Provide metalic nipples with shutoffs for all PVC penetrations thru watertight bulkheads. LEGACY COMPONENT DESC: Valve
Condition: Improper Installation
Due 18 January 2002
Resolved 18 January 2002
Resolution: Previously entered (double entry)
Engineering › Freshwater Generation System
Issued 4 January 2002 Resolved
Provide support for engine exhaust in fresh water compartment LEGACY COMPONENT DESC: Base Plate
Condition: Improper Installation
Due 18 January 2002
Resolved 18 January 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 4 January 2002 Resolved
Clean galley stove exhaust vent and remove grease as necessary. LEGACY COMPONENT DESC: Portable Electric Equipment/Appliances
Condition: Unknown
Due 18 January 2002
Resolved 18 January 2002
Fire Fighting › Fire Hoses
Issued 2 January 2002 Resolved
Provide nozzle for fire hose IAW 46 CFR 181.320 (a) (b) LEGACY COMPONENT DESC: Condition
Condition: Improper Installation
Due 18 January 2002
Resolved 18 January 2002
Construction/Loadline
Issued 1 February 2001 Resolved
Provide metallic valves and penetration for PVC traversing water tight bulkheads.
Condition: Unknown
Due 1 February 2002
Resolved 25 February 2002
Resolution: Vessel meets non-metallic piping installation requirements of 46 Code of Federal Regulations 182.700.
Lifesaving
Issued 1 February 2001 Resolved
Provide damage control kit consisting of a mallot, various sized cone plugsand okum in a labeled container/bag. Kit is to be stored in an accessable area above the bulkhead deck.
Condition: Unknown
Due 1 February 2001
Resolved 12 February 2001
Lifesaving
Issued 8 January 2001 Resolved
Provide valid EPIRB registration.
Condition: Unknown
Due 15 January 2001
Resolved 6 February 2001
Lifesaving
Issued 8 January 2001 Resolved
Provide EPIRB hydrostatic release date and print it on the hydro release unit.
Condition: Unknown
Due 15 January 2001
Resolved 6 February 2001
Lifesaving
Issued 8 January 2001 Resolved
Print the number and type of life jackets on galley benches.
Condition: Unknown
Due 15 January 2001
Resolved 6 February 2001
Navigation
Issued 8 January 2001 Resolved
Properly repair compass light.
Condition: Unknown
Due 15 January 2001
Resolved 6 February 2001
Fire Fighting
Issued 16 December 1999 Resolved
Prove proper operation of fire pump. Missing nozzle. 46CFR181.10
Condition: Unknown
Due 16 January 2000
Resolved 27 January 2000
Construction/Loadline
Issued 16 December 1999 Resolved
Properly seal all watertight bulkhead through fittings. 46CFR179.320
Condition: Unknown
Due 16 January 2000
Resolved 27 January 2000
Construction/Loadline
Issued 16 December 1999 Resolved
Install valve on engineroom side of bait tank supply line. 46CFR182-40
Condition: Unknown
Due 16 January 2000
Resolved 27 January 2000
Engineering
Issued 16 December 1999 Resolved
Remove soft rubber pipe plug cap on SSDG exhaust and secure properly. 46CFR182.15-20
Condition: Unknown
Due 16 January 2000
Resolved 27 January 2000
Documentation
Issued 16 December 1999 Resolved
Renew outdated FCC Safety Certificate.
Condition: Unknown
Due 23 December 1999
Resolved 10 January 2000
Lifesaving
Issued 16 December 1999 Resolved
Attach water light lanyard to life ring with clip 46CFR180.70
Condition: Unknown
Due 30 January 2000
Resolved 10 January 2000
Engineering
Issued 16 December 1999 Resolved
Install fuel cut-out valves for both MDE. 46CFR185.30-20
Condition: Unknown
Due 16 January 2000
Resolved 10 January 2000
Navigation
Issued 22 December 1998 Resolved
Provide light on magnetic compass.
Condition: Unknown
Due 10 January 1999
Resolved 8 January 1999
Electrical
Issued 22 December 1998 Resolved
MAKE CORRECTIONS TO VESSEL WIRING SYSTEMS TO INCLUDE; THE REMOVAL OF DEAD END WIRES, ADDING METAL BANDING STRAPS (EVERY 24") AROUND WIRES, AND BANDING ALL HANGING WIRES IN ALL COMPARTMENTS.
Condition: Unknown
Due 10 January 1999
Resolved 8 January 1999
Fire Fighting
Issued 22 December 1998 Resolved
PROVIDE PROOF OF FIRE EXTINGUISHER SERVICING.
Condition: Unknown
Due 10 January 1999
Resolved 8 January 1999
Navigation
Issued 22 December 1998 Resolved
REPLACE BULB ON STERNLIGHT.
Condition: Unknown
Due 10 January 1999
Resolved 8 January 1999
Navigation
Issued 22 December 1998 Resolved
PURCHASE CURRENT EDITIONS OF COAST PILOTS, TIDAL/CURRENT TABLES, AND LIGHT LIST.
Condition: Unknown
Due 10 January 1999
Resolved 8 January 1999
Construction/Loadline
Issued 22 December 1998 Resolved
PROVIDE PROPER LOCK FOR OVERBOARD SEWAGE VALVE.
Condition: Unknown
Due 10 January 1999
Resolved 8 January 1999
Electrical
Issued 22 December 1998 Resolved
PROVIDE LABELS FOR BATTERY SWITCHES IN ENGINE ROOM.
Condition: Unknown
Due 10 January 1999
Resolved 8 January 1999
Documentation
Issued 18 December 1997 Resolved
Establish and maintain logbooks to record drills, tests, etc. per 46 CFR part 185.
Condition: Unknown
Due 18 December 1997
Resolved 18 December 1997
Construction/Loadline
Issued 18 December 1997 Resolved
Repair and demonstrate proper operation of forepeak high water alarm.
Condition: Unknown
Due 18 December 1997
Resolved 18 December 1997
Construction/Loadline
Issued 14 March 1997 Resolved
REMOVE ALL WASTED SUPPORTS FOR FOREPEAK DECK AND REPLACE IN KIND.
Condition: Unknown
Due 14 March 1997
Resolved 21 March 1997
Construction/Loadline
Issued 14 March 1997 Resolved
REMOVE ALL WASTED FRAMING IN LAZARETTE AND REPLACE IN KIND.
Condition: Unknown
Due 14 March 1997
Resolved 21 March 1997
Construction/Loadline
Issued 14 March 1997 Resolved
CROP OUT TO GOOD METAL LOCATED ON SIDE SHEEL IN WAY OF PORT SIDE IN VOID TWO. PROVIDE INSERT 32" X 29" FOR INSPECTION.
Condition: Unknown
Due 14 March 1997
Resolved 21 March 1997
Construction/Loadline
Issued 17 December 1996 Resolved
Properly repair and make collision and subdivision bulkheads watertight.
Condition: Unknown
Due 17 January 1997
Resolved 27 January 1997
Lifesaving
Issued 17 December 1996 Resolved
Provide and properly post placard for donning life jackets.
Condition: Unknown
Due 17 January 1997
Resolved 27 January 1997
Lifesaving
Issued 17 December 1996 Resolved
Provide CG approved first aid kit.
Condition: Unknown
Due 17 January 1997
Resolved 27 January 1997
Lifesaving
Issued 17 December 1996 Resolved
Provide and properly post broadcast placard.
Condition: Unknown
Due 17 January 1997
Resolved 27 January 1997
Engineering
Issued 17 December 1996 Resolved
Properly mark emergency fuel shut offs on main deck.
Condition: Unknown
Due 17 January 1997
Resolved 27 January 1997
Engineering
Issued 6 December 1994 Resolved
RENEW PORT EMERGENCY FUEL SHUT-OFF REACHY ROD AT VALVE IN ENGINE ROOM.
Condition: Unknown
Due 12 December 1994
Resolved 15 December 1994
Lifesaving
Issued 6 December 1994 Resolved
REMOUNT CLASS A EPIRB TO BE FLOAT FREE AND NOT UNDER ANY OVER HANGS.
Condition: Unknown
Due 12 December 1994
Resolved 15 December 1994
Accommodation/Occupational Safety
Issued 6 December 1994 Resolved
PROVIDE AND MOUNT IN PASSENGER AREA MARPOL FIVE DISCHARGE PLACARD.
Condition: Unknown
Due 12 December 1994
Resolved 15 December 1994
Lifesaving
Issued 6 December 1994 Resolved
RENEW DETERIORATED LINE ON LIFE RING.
Condition: Unknown
Due 12 December 1994
Resolved 15 December 1994
Fire Fighting
Issued 6 December 1994 Resolved
REMOUNT FIRE EXTINGUISHER LOCATED PORTSIDE AFT IN GALLERY BEHIND DOOR. MOVE FORWARD AND AWAY FROM DOOR.
Condition: Unknown
Due 12 December 1994
Resolved 15 December 1994
Lifesaving
Issued 6 December 1994 Resolved
PROVIDE PROOF THAT CLASS A EPIRB WAS MANUFACTERED AFTER 01 SEP 88.
Condition: Unknown
Due 12 December 1994
Resolved 12 December 1994
Electrical
Issued 6 December 1994 Resolved
WIRES FROM OLD BAIT PUMP IN ENGINE ROOM NEED TO BE REMOVED.
Condition: Unknown
Due 12 December 1994
Resolved 15 December 1994
Electrical
Issued 27 November 1989 Resolved
PROVIDE COVER TO THE BATTERY BOX IN THE ENGINE ROOM.
Condition: Unknown
Due 27 November 1989
Resolved 27 November 1989
Accommodation/Occupational Safety
Issued 27 November 1989 Resolved
PROVIDE PERMANENT CAP TO THE UNUSED SINK OVERBOARD DISCHARGE THROUGH HULL PENETRATION IN WAY OF MSD COMPARTMENT.
Condition: Unknown
Due 27 November 1989
Resolved 27 November 1989
Fire Fighting
Issued 27 November 1989 Resolved
RELOCATE ONE B-II PORTABLE FIRE EXTINGUISHER STOWAGE ON THE ENTRANCE TO THEENGINE ROOM.
Condition: Unknown
Due 27 November 1989
Resolved 27 November 1989
Engineering
Issued 27 November 1989 Resolved
REMOVE EXCESSIVE OIL IN THE ENGINE ROOM BILGES.
Condition: Unknown
Due 27 November 1989
Resolved 27 November 1989
Navigation
Issued 23 November 1988 Resolved
REPLACE 6 HAND HELD ORANGE SMOKE FLARES ON OR BEFORE 30 APRIL 1989.
Condition: Unknown
Due 23 November 1988
Resolved 23 November 1988
Unknown
Issued 15 September 1987 Resolved
REPLACE WORN RUBBER GASKETS ON ALL DECK HATCHES.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Electrical
Issued 15 September 1987 Resolved
INSTALL DRIP PROOF COVERS ON ELECTRICAL PANELS IN ENGINEROOM.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Construction/Loadline
Issued 15 September 1987 Resolved
CLEAN SEA VALVES' SEATS AND GUIDES IN ENGINEROOM.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Construction/Loadline
Issued 15 April 1986 Resolved
REPLACE WASTED PLATING IN OVERHEAD OF PORT AND STBD SIDE OF #2 BILGE COMPARTMENT.
Condition: Unknown
Due 15 April 1986
Resolved 15 April 1986
Engineering
Issued 15 April 1986 Resolved
REPLACE BILGE STRAINER IN #4BILGE COMPARTMENT
Condition: Unknown
Due 15 April 1986
Resolved 15 April 1986
Documentation
Issued 18 December 1985 Resolved
PROVIDE CURRENT VESSEL DOCUMENT DECAL
Condition: Unknown
Due 18 December 1985
Resolved 18 December 1985
Lifesaving
Issued 18 December 1985 Resolved
PROVIDE 3 CG APPROVED FLOAT LIGHTS,2 FOR BUOYANT APPS,1 FOR RING BUOY
Condition: Unknown
Due 18 December 1985
Resolved 18 December 1985
Documentation
Issued 18 December 1985 Resolved
PROVIDE CURRENT SHIP STATION RADIO LICENCE
Condition: Unknown
Due 18 December 1985
Resolved 18 December 1985

Casualty record · 3

25 June 2010Routine · role: Involved in a Marine Casualty · activity 3781212
10 April 2014Routine · role: Involved in a Marine Casualty · activity 4834254
10 June 2023Routine · role: Involved in a Marine Casualty · activity 7791870
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.