Inspection history · 27
31 March 2026
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8338794
4 March 2026
Vessel Attendance · Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8320113
3 September 2025
Special Consideration · Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8225994
26 February 2025
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8085234
19 February 2025
Drydock Exam · Annual Inspection · Deficiency Check · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8081700
28 February 2024
Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7872324
8 January 2024
Special · Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7847855
2 January 2024
COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7844244
31 August 2023
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7781889
11 April 2023
Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7666543
22 March 2023
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7655539
15 August 2022
In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7534087
30 January 2022
Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 7388097
5 January 2022
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7376472
23 August 2021
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7294534
17 August 2021
In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7289406
5 January 2021
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7120093
21 April 2020
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6942439
18 March 2020
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6928543
24 September 2019
In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6822772
29 August 2019
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6799009
15 January 2019
Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6610407
19 October 2018
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6570650
4 January 2018
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6332077
28 September 2017
Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6280460
12 January 2017
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6066367
5 January 2016
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5790485
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 4 March 2026
Resolved
Vessel's interconnected fire detection system was inoperable. Vessel restricted to not more than 20 miles from harbor of safe refuge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 March 2026
Resolution: Corrected.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 February 2025
Resolved
Stability Letter: Estimated 1,000 lbs of lead ingot ballast discovered in lazarette space. Stability Letter for vessel could not be found. SST conducted in 1996 does not identify ballast. A new Stability Letter based on the 1996 SST will be routed. Ballast to be removed upon returning to mooring.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 11 March 2025
Resolution: All lead ballast removed. Stability Letter routed for signature.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 8 January 2024
Resolved
Vessel must provide means to safely recover a person from the water.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 February 2024
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 January 2024
Resolved
Vessel must provide a third fire bucket.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 January 2024
Resolution: Received objective evidence item cleared.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 8 January 2024
Resolved
Vessel's remote fuel shutoff valve must be labeled.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 January 2024
Resolution: Received objective evidence item corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 January 2024
Resolved
Vessel must provide (01) more child size PFD.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 January 2024
Resolution: Received objective evidence item corrected.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 8 January 2024
Resolved
Ballast not identified on vessel's stability letter was discovered in steering compartment. This ballast must either be removed or a new stability analysis must be conducted.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 February 2024
Resolution: Ballast has been removed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 8 January 2024
Resolved
Make permanent repairs to the port, aluminum, vertical deck support in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 February 2024
Resolution: Corrected.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 8 January 2024
Resolved
Deck crew must be enrolled in a drug testing program.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 February 2024
Resolution: Corrected.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 8 January 2024
Resolved
Master must have a valid medical certificate or an acceptable waiver.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 February 2024
Resolution: Corrected.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 January 2024
Resolved
Vessel was lacking FCC Safety Certificate for marine band radio installations.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 February 2025
Resolution: Corrected.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 8 January 2024
Resolved
Vessel radio must have GPS and MMSI number programmed into marine band radios.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 February 2024
Resolution: Corrected
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 22 March 2023
Resolved
Vessel required to have interconnected fire detection system that meet specific requirements in 46 CFR 181.450. Vessel did not have onboard or installed interconnected fire detection system. Vessel limited to Limited Coastwise until fire detection system installed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 11 April 2023
Resolution: Interconnected smoke detectors provided.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 22 March 2023
Resolved
Inspect Epirb. Epirb battery, registration, and hydro static release were expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2023
Resolved 11 April 2023
Resolution: New epirb provided.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 22 March 2023
Resolved
Inspect survival craft arrangements. Life float light holder, satisfactory paddles, and weak link tag were not provided.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2023
Resolved 11 April 2023
Resolution: Satisfactory lifefloat arrangements provided.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 22 March 2023
Resolved
Inspect for compliance with Federal Communications Commission. Satisfactory Radio Safety Certificate was not provided.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2023
Resolved 8 January 2024
Resolution: Vessel inspectewd on 08 Jan 24. This deficiencty was still outstanding. Def cleared and reissued.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 5 January 2022
Resolved
Each lifefloat must be in good and serviceable condition. Lifefloat is severely wasted and deteriorated.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 February 2022
Resolved 11 April 2023
Resolution: Satisfactory lifefloat provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 5 January 2022
Resolved
Strong and effective rudder stops must be provided to prevent jamming and damage to the rudder. Rudder stops are wasted. Repair shall be completed at next dry-dock. Repair shall be witnessed by attending CG Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 22 March 2023
Resolution: Rudder stops renewed.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 5 January 2022
Resolved
Main deck starboard side was identified as being wasted and separated from deck support. Provide repair proposal to local OCMI for approval. Area to be repaired at next dry-dock and inspected by attending CG Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 22 March 2023
Resolution: Deck repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 5 January 2021
Resolved
Service Life Float to correct the color and reflective tape on lifesaving device.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 February 2021
Resolved 23 February 2021
Resolution: Vessel owner provided email proof of Life Float repair.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 5 January 2021
Resolved
Update Nautical publications (Light List, Tide Table, NTM, and Navigation Rules).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 February 2021
Resolved 23 February 2021
Resolution: Vessel owner provided email proof of updated Nautical publications.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 January 2021
Resolved
Remove excess power-strips on Bridge. Currently the Bridge has multiple power-strips on the starboard side console.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 February 2021
Resolved 23 February 2021
Resolution: Vessel owner provided email proof of the removal of excess power strips on the Bridge.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 January 2021
Resolved
Fix starboard side Navigational Light to be in operational conditions.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2021
Resolved 23 February 2021
Resolution: Vessel owner provided email proof of starboard Navigational light being operational.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 January 2021
Resolved
Properly secure wires in Lazarette to reduce hanging. The current strand of wires hangs without any form of support.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 February 2021
Resolved 23 February 2021
Resolution: Vessel owner provided email proof of fixed wires in Lazarette.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 January 2021
Resolved
Properly install sewage tank pump and sewage tank.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 February 2021
Resolution: Vessel owner provided email proof of properly installed sewage tank pump and sewage tank.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 24 September 2019
Resolved
Vessel is required to mark emergency exit on both sides with EMERGENCY EXIT-KEEP CLEAR in 1" letters. Vessel does not have outside exit marked. Vessel shall mark exit as required.
46 CFR 177.15
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 September 2019
Resolved 25 September 2019
Resolution: Vessel crew marked emergency escape on outside of escape as required.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 24 September 2019
Resolved
Vessel engine room ventilation should have means to close in case of fire. Current pulley system does not effectively close off air to the space. Vessel to repair pulls to completely close vents leading to the engine room.
46 CFR 182.465(h)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 September 2019
Resolved 25 September 2019
Resolution: Vessel crew repaired pulley system and was able to close off air to the engine room.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 15 January 2019
Resolved
Provide proof of updated navigation publications. (Nav rules, charts, light list, tide tables, etc)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 January 2019
Resolution: Received proof of proper nautical publications.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 15 January 2019
Resolved
Install covers on berthing area lights.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 February 2019
Resolution: Light fixtures replaced
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 15 January 2019
Resolved
Repair stern space ladder posts.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 January 2019
Resolution: Received proof of repairs to stern space ladder.
Fire Fighting › Fire Bucket › Availability
Issued 4 January 2018
Resolved
Provide 3 fire buckets 46 CFR 181.610 (No Sail)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 January 2018
Resolved 4 January 2018
Resolution: Onwner was able to find 3 fire buckets.
Communications › Audible Communications › Horn/Whistle
Issued 4 January 2018
Resolved
Provide an operational Horn.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 January 2018
Resolved 22 February 2018
Resolution: Vessel qwner purchased new horn.
Stability › Watertight Integrity › General
Issued 4 January 2018
Resolved
Replace gasket on tank room water tight hatch. 46 CFR 179.360 (No Sail)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 January 2018
Resolved 22 February 2018
Resolution: Owner installed gasket on hatch.
Engineering › Bilge Water Management System › Not Operational
Issued 4 January 2018
Resolved
Repair/Replace tank room bilge pump float switch. 46 CFR 182.530 (No Sail)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 January 2018
Resolved 22 February 2018
Resolution: Owner installed new float switch.
Engineering › Engine Controls (Electric/Electronic) › Linkage
Issued 4 January 2018
Resolved
Repair/Replace STBD Gen Sensor (due to oil leak)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 February 2018
Resolved 22 February 2018
Resolution: Owner repaired oil leak by installing a new sensor.
Lifesaving › Lifefloat › Lifeline
Issued 12 January 2017
Resolved
Line of life ring
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 January 2017
Resolved 13 January 2017
Resolution: replaced
Deck/Cargo › Holds/Tanks › Scuttle
Issued 12 January 2017
Resolved
Step in Lazerate was loose and fell off.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 13 January 2017
Resolved 13 January 2017
Resolution: Line was resecured.
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 12 January 2017
Resolved
Bowl from fuel filter was missing
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 January 2017
Resolved 13 January 2017
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 19 January 2016
Resolved
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 January 2016
Resolved 19 January 2016
Resolution: Radio Telephony Certificate was issued.
Fire Fighting › Fire Bucket › Capacity
Issued 5 January 2016
Resolved
Provide one fire bucket
Action required: 705 - Other - as specified
Due 19 January 2016
Resolved 19 January 2016
Resolution: Bucket was replaced.
Engineering › Fuel Oil Service System › Hose
Issued 5 January 2016
Resolved
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 January 2016
Resolved 19 January 2016
Resolution: Replaced fuel line
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 5 January 2016
Resolved
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 January 2016
Resolved 19 January 2016
Resolution: Alcohol test strips were put on the vessel.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 5 January 2016
Resolved
Condition: Invalid
Due 19 January 2016
Resolved 19 January 2016
Resolution: Electrical breaker was replaced.