MAURY USCG vessel records Sign in
← All vessels

BOURGOGNE

BOURGOGNE is a 1996 tank ship. The Coast Guard has recorded 10 inspections since 1996, most recently in June 2006, along with 9 deficiencies and 1 operational control.

Records from 1996 to 2006. Most recent: inspection, 26 June 2006.

Built
1996
Last inspected
26 June 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9077800 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
439485
Flag
LUXEMBOURG
—
Maury page id
psix-439485

Inspections, by type

…with no type recorded5
Years with a record 9 calendar years (1996–2006)
The 10 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it161178 - Regulatory (Subpart C or D), Gross Ton
161287 - Convention (Subpart B), Gross Ton
93837 - Regulatory (Subpart C or D), Net Ton
93837 - Convention (Subpart B), Net Ton
353415 - Displacement, Ton
304162 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 10

26 June 2006 ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2680028
15 December 2004 COC-TVE Renew · ISPS II Exam
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2259670
5 February 2003 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1740139
2 December 2002 Tank Vessel Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1712957
18 September 2001 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 293747
18 September 2001 Tank Vessel Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1074253
12 October 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 433734
17 August 1998 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 419415
4 August 1997 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 406640
1 June 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 391882

Deficiency record · 9

Deck/Cargo › Crude Oil Washing Systems › Crude Oil Washing System Pump
Issued 2 December 2002 Resolved
Make proper repairs to the satisfaction of class to the COW pump in pumproom prior to next US Port.
Due 2 December 2002
Resolved 2 December 2002
Resolution: Attended and rcvd class report attesting to the proper operation of COW.
Lifesaving › Lifeboat
Issued 2 December 2002 Resolved
Replace retro-reflective tape IWO free fall lifeboat within 30 days. LEGACY COMPONENT DESC: Markings
Due 2 January 2003
Resolved 31 December 2002
Resolution: Rcvd report.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 2 December 2002 Resolved
Prior to the operation of #1 cargo pump make permanent repairs to gasket and/or bolts to prevent excessive leaking, to the satisfaction of class. LEGACY COMPONENT DESC: Cargo Pump
Due 2 December 2002
Resolved 26 December 2002
Resolution: Rcvd Report.
Deck/Cargo
Issued 18 September 2001 Resolved
Make proper repairs to the satisfaction of class to the COW pump
Condition: Unknown
Due 18 September 2001
Resolved 2 December 2002
Deck/Cargo
Issued 18 September 2001 Resolved
Make proper repairs to leaking cargo pump to satisfaction of class prior tonext US port
Condition: Unknown
Due 18 September 2001
Resolved 2 December 2002
Deck/Cargo
Issued 18 September 2001 Resolved
Prove proper operation of Inert Gas Bolier system prior to conducting cargooperations
Condition: Unknown
Due 18 September 2001
Resolved 2 December 2002
Deck/Cargo
Issued 18 September 2001 Resolved
Prove operation of ODME prior to next cargo transfer
Condition: Unknown
Due 18 September 2001
Resolved 2 December 2002
Deck/Cargo
Issued 1 June 1996 Resolved
O.D.M.E. monitor not working. O.D.M.E monitor to be repaired prior to re- entry into U.S. Waters.
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Navigation
Issued 1 June 1996 Resolved
Loose bolts on the rudder carrier bearing steering gear system.
Condition: Unknown
Due 2 June 1996
Resolved 4 June 1996

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.