Records from 1996 to 2011. Most recent: inspection, 25 September 2011.
Inspection history · 20
25 September 2011
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4153659
19 September 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4148720
10 July 2011
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4075936
13 July 2008
ISPS II Exam · Deficiency Check · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3265365
12 July 2008
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3264170
12 July 2008
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3265329
19 May 2007
MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam · MARPOL Annex V Examination · NPV Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2931377
30 August 2006
PII Safety Exam · MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2756090
22 April 2006
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2630850
3 May 2005
ISPS II Exam · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2348252
31 August 2001
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 293355
26 July 2000
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 280400
26 July 2000
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 280847
26 July 2000
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 284408
24 January 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 273803
6 July 1999
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 430141
3 June 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 416415
24 December 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 471227
13 May 1997
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 403679
20 May 1996
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 391414
Navigation › Collision/Grounding Avoidance › Radar
Issued 25 September 2011
No resolution recorded
The radar was reported as not operational.
Due 24 November 2011 — due date passed with no resolution recorded
Engineering › Diesel Engine (auxiliary) › Crankshaft
Issued 12 July 2008
Resolved
All three ships service generators rear main oil seals are leaking between the engines and generators, creating a fire hazard. The ships crew has rigged metal deflectors to direct the oil away from hazards and into the bilge. Provide class report attesting to the repair. Code 17 A, C
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 July 2008
Resolution: Oily areas surrounding the generators were cleaned up. The bolts for the rear side cover gasket packings were tightened. Immediate fire hazard was mitigated. Class issued a condition of class to be repaired by 16SEP08.
Engineering › Sea-water System (primary cooling) › Piping
Issued 12 July 2008
Resolved
The number one ships service generator salt water cooling line has been temporarily repaired with a fiberglass soft patch. Provide class report attesting to the repair. Code 17 A, C
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 July 2008
Resolution: A section of piping was cut out where the hole was located and a new section was welded into place. The R/W system is fully operational.
Engineering › Sea-water System (primary cooling) › Piping
Issued 12 July 2008
Resolved
The air conditioning sea water pump suction line has been temporarily repaired with soft patches. the soft patches are located between the main sea water line and before the air conditioning pump suction cut off valve, creating a potential flooding hazard. Provide class report attesting to repairs.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 July 2008
Resolution: A section of piping was removed and a new piece of piping was replaced to remove the areas of both soft patches.
Construction/Loadline › Markings › Load Line Mark
Issued 19 May 2007
Resolved
The port and starboard side Loadline marks are not painted in contrasting color as required.
Action required: 705 - Other - as specified
Due 26 May 2007
Resolved 24 May 2007
Resolution: PSCO verified that the port and starboard side Loadline marks were painted in contrasting color while vessel was anchored.
Documentation › Certificates/Documents › Cargo Ship Safety Equipment Certificate
Issued 30 August 2006
Resolved
Vsl needs to fax new, valid safety equipment certificate to USCG. Certificate was expired upon inspection.
Action required: 705 - Other - as specified
Due 26 September 2006
Resolved 13 September 2006
Resolution: Vsl faxed valid safety equipment certificate to USCG.
Electrical › Electric Generation Source (emergency) › Switch
Issued 3 May 2005
Resolved
REMOTE SHUTOFF FOR EMERGENCY GENERATOR FUEL SUPPLY IS NOT INSTALLED. INSTALL REMOTE SHUTOFF OUTSIDE GENERATOR SPACE.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 April 2006
Resolution: Received class report from NKK satisfying requirement.
Engineering
Issued 31 August 2001
Resolved
WATER LEAK IN WAY OF LOWER FLANGE OF AIR COOLER LOCATED AFT END OF MAIN DIESEL ENGINE, LOWER DECK, STBD SIDE. WELD CRACKED. PROVIDE REPAIR REPORTFROM CERTIFICATE ISSUING AUTHORITY PRIOR TO 31 SEP 2001. SOLAS 74 AMMENDD I/11.
Condition: Unknown
Due 7 November 2001
Resolved 7 November 2001
Fire Fighting
Issued 31 August 2001
Resolved
FIRE SCREEN DOORS DO NOT CLOSE PROPERLY. REPAIR TO THE SATISFACTION OF CERTIFICATE ISSUING AUTHORITY PRIOR TO 31 SEP 01. SOLAS 74 AMMENDED II- 2/46 AND SOLAS 74 AMMENDED II-2/47.
Condition: Unknown
Due 7 November 2001
Resolved 7 November 2001
Documentation
Issued 31 August 2001
Resolved
DECK LINE NOT PAINTED A CONTRASTING COLOR TO THE HULL. REPAINT TO THE SATISFACTION OF THE CERTIFICATE ISSUING AUTHORITY, PRIOR TO 31 SEP 01. ICCL REGULATION 8.
Condition: Unknown
Due 7 November 2001
Resolved 7 November 2001
Navigation
Issued 26 July 2000
Resolved
US COAST PILOT VOLUME #7 IS NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 10 September 2001
Resolved 10 September 2001
Engineering
Issued 6 July 1999
Resolved
Bunker line pressure test was not proformed.
Condition: Unknown
Due 24 January 2000
Resolved 24 January 2000
Lifesaving
Issued 6 July 1999
Resolved
Solas 74 chapter III Reg. 41/6.2 The engines starting system did not start within the required 2 minutes of the commencing of the starting procedures
Condition: Unknown
Due 7 July 1999
Resolved 8 July 1999