Records from 1985 to 2002. Most recent: inspection, 11 October 2002.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 31
11 October 2002
Administrative Inspection
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1694737
15 January 2002
Administrative Inspection · Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1478815
5 October 2001
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1075553
12 July 2001
Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1460576
25 January 2000
Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 815184
29 May 1998
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1441387
24 June 1997
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1425916
25 April 1997
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1471138
22 January 1997
Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1099461
18 October 1996
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 847002
19 September 1996
Damage Survey
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1136513
30 April 1996
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1083026
26 May 1995
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 872111
20 April 1995
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 857916
27 March 1995
Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 830952
2 May 1994
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1168392
25 April 1994
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1168514
17 May 1993
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 838600
27 April 1993
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 831639
18 June 1992
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1259795
15 June 1992
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1269871
13 May 1992
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 959750
30 April 1991
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1216033
22 June 1990
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1240943
23 April 1990
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 910735
13 November 1989
Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1219983
16 May 1989
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 893621
26 April 1988
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1343716
27 April 1987
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1318106
23 April 1986
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1306853
26 April 1985
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 980363
Engineering
Issued 24 June 1997
Resolved
REPLACE ER AIR RECEIVER WITH ONE MEETING 46 CFR 182.330.
Condition: Unknown
Due 24 June 1997
Resolved 24 June 1997
Documentation
Issued 24 June 1997
Resolved
ESTABLISH A CHEMICAL TESTING PROGRAM IAW 46 CFR 16.
Condition: Unknown
Due 24 June 1997
Resolved 24 June 1997
Engineering
Issued 25 April 1997
Resolved
REPLACE THE ENGINE ROOM AIR RECEIVER WITH ONE MEETING 46 CFR 182.330
Condition: Unknown
Due 25 April 1997
Resolved 25 April 1997
Unknown
Issued 25 April 1997
Resolved
ESTABLISH A CHEMICAL TESTING PROGRAM PER 46 CFR 16.
Condition: Unknown
Due 25 April 1997
Resolved 25 April 1997
Electrical
Issued 19 September 1996
Resolved
DETERMINE THE CAUSE OF THE SHORE POWER FAILURE AND PROVE PROPER OPERATION OF THE SYSTEM UPON COMPLETION OF REPAIRS.
Condition: Unknown
Due 19 September 1996
Resolved 19 September 1996
Electrical
Issued 19 September 1996
Resolved
REPLACE THE SHORE POWER CABLE AND RECEPTACLE.
Condition: Unknown
Due 19 September 1996
Resolved 19 September 1996
Documentation
Issued 20 April 1995
Resolved
ESTABLISH PRE-EMPLOYMENT/RANDOM DRUG TESTING PROGRAM.
Condition: Unknown
Due 20 April 1995
Resolved 20 April 1995
Lifesaving
Issued 20 April 1995
Resolved
PROVIDE SIX (06) RED FLARE DISTRESS SIGNALS.
Condition: Unknown
Due 20 April 1995
Resolved 20 April 1995
Engineering
Issued 25 April 1994
Resolved
REPAIR THE PORT FUEL OIL EMERGENCY SHUT OFF VALVE.
Condition: Unknown
Due 25 April 1994
Resolved 25 April 1994
Electrical
Issued 25 April 1994
Resolved
PERMANENTLY ATTACH BATTERY CHARGING CABLES TO THE RADIO BACK-UP BATTERY TERMINALS.
Condition: Unknown
Due 25 April 1994
Resolved 25 April 1994
Electrical
Issued 25 April 1994
Resolved
INSTALL GUARD FOR BATTERY CHARGING TERMINALS ON THE FORWARD BULKHEAD OF THEENGINEROOM.
Condition: Unknown
Due 25 April 1994
Resolved 25 April 1994
Accommodation/Occupational Safety
Issued 25 April 1994
Resolved
REPAIR THE MARINE SANITATION DEVICE CONTROL UNIT. INSURE SYSTEM IS FULLY OPERATIONAL.
Condition: Unknown
Due 25 April 1994
Resolved 25 April 1994
Electrical
Issued 25 April 1994
Resolved
INSULATE RESISTORS FROM GENERATOR START TERMINAL BOARD.
Condition: Unknown
Due 25 April 1994
Resolved 25 April 1994
Electrical
Issued 25 April 1994
Resolved
INSTALL GUARD OVER SHIPS SERVICE GENERATOR START TERMINAL BOARD.
Condition: Unknown
Due 25 April 1994
Resolved 25 April 1994
Engineering
Issued 25 April 1994
Resolved
REPAIR CRACKED FUEL LINE TO THE FANTAIL GENERATOR LOCATED IN THE AFT STEERING COMPARTMENT JUST BEFORE THE DECK PENETRATION.
Condition: Unknown
Due 25 April 1994
Resolved 25 April 1994
Navigation
Issued 25 April 1994
Resolved
INSTALL COTTER PINS ON BOTH RUDDER POSTS.
Condition: Unknown
Due 25 April 1994
Resolved 25 April 1994
Fire Fighting
Issued 25 April 1994
Resolved
PROVIDE INSTRUCTION PLACARDS FOR THE FIXED CO2 SYSTEM PULL STATIONS INDICATING WHAT COMPARTMENT IS EFFECTED BY THE RELEASE.
Condition: Unknown
Due 25 April 1994
Resolved 25 April 1994
Engineering
Issued 25 April 1994
Resolved
INSATLL FLAME SCREENS IN THE FUEL TANK COMPARTMENT VENTS.
Condition: Unknown
Due 25 April 1994
Resolved 25 April 1994
Engineering
Issued 25 April 1994
Resolved
REPAIR MAIN ENGINE STARTING CONTROLS FROM THE BRIDGE.
Condition: Unknown
Due 25 April 1994
Resolved 25 April 1994
Documentation
Issued 25 April 1994
Resolved
ESTABLISH A RANDOM URINALISIS DRUG TESTING PROGRAM.
Condition: Unknown
Due 25 April 1994
Resolved 25 April 1994
Lifesaving
Issued 25 April 1994
Resolved
PROVIDE A CREW FOR UNDERWAY TESTING AND DRILLS.
Condition: Unknown
Due 25 April 1994
Resolved 25 April 1994
Lifesaving
Issued 25 April 1994
Resolved
REPLACE BOTH RING BUOYS AND LINES.
Condition: Unknown
Due 25 April 1994
Resolved 25 April 1994
Fire Fighting
Issued 25 April 1994
Resolved
REPLACE CO2 EXTINGUISHER AT FANTAIL GENERATOR WITH APPROVED TYPE
Condition: Unknown
Due 25 April 1994
Resolved 25 April 1994
Documentation
Issued 27 April 1993
Resolved
Provide and install the oil pollution discharge warning placard required by33 CFR 155.450.
Condition: Unknown
Due 3 May 1993
Resolved 3 May 1993
Engineering
Issued 27 April 1993
Resolved
Prove the proper operation of the port fuel tank remote shutoff valve and reach rod. (46 CFR 182.20-40)
Condition: Unknown
Due 17 May 1993
Resolved 17 May 1993
Lifesaving
Issued 27 April 1993
Resolved
Provide onboard 6 USCG approved orange smoke distress signals with valid expiration dates. (46 CFR 180.35-5)
Condition: Unknown
Due 17 May 1993
Resolved 17 May 1993
Fire Fighting
Issued 27 April 1993
Resolved
Provide evidence that the 15 pound CO2 fire extinguisher mounted on the stern has been hydrostatically tested within the past 5 years. (46 CFR 147.65)
Condition: Unknown
Due 17 May 1993
Resolved 17 May 1993
Electrical
Issued 13 May 1992
Resolved
PROPERLY MOUNT SWITCHES IN GALLEY FOR HEATING-A/C INTO JUNCTION BOX, AS REQUIRED BY 46 C.F.R. 183.01-15(A), NO LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 13 May 1992
Resolved 13 May 1992
Construction/Loadline
Issued 13 May 1992
Resolved
REMOVE OPEN PIPE AND INSERT HULL PLATE ON STARBOARD SIDE ENGINE ROOM OR OUTFIT WITH CAP OR VALVE TO PREVENT WATER FROM ENTERING AS PER 46 CFR 171.119, NO LATER THAN THE COMPLIANCE DATE._x001C_
Condition: Unknown
Due 13 May 1992
Resolved 13 May 1992
Fire Fighting
Issued 13 May 1992
Resolved
PROVIDE RECOMMENDATIONS FOR MODIFICATION OF INSTALLED CO2 SYSTEM FOR ENGINEROOM TO ADDRESS THE UNATTENDED ENGINE ROOM CLOSURES AND THE LACK OF AN INSTALLED AUDIBLE ALARM AS PER 46 CFR 181.05-5, NO LATER THAN THE COMPLIANCE DATE._x001C_
Condition: Unknown
Due 13 May 1992
Resolved 13 May 1992
Unknown
Issued 13 May 1992
Resolved
REMOVE PLASTIC JUGS FILLED WITH LUBE OIL FROM ENGINE ROOM AS PER 46 CFR 176.25-50, NO LATER THAN THE COMPLIANCE DATE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 May 1992
Resolved 13 May 1992
Electrical
Issued 13 May 1992
Resolved
REPLACE MISSING COVER ON JUNCTION BOX LOCATED ON THE OVERHEAD OF THE ENGINEROOM, AS REQUIRED BY 46 C.F.R. 183.01-15(A), NO LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 13 May 1992
Resolved 13 May 1992
Construction/Loadline
Issued 13 May 1992
Resolved
STOW HAND AND POWER BILGE PUMPS IN AN ACCESSIBLE LOCATION AND OUTFIT WITH SUFFICIENT ELECTRICAL CORD AND DISCHARGE HOSE TO BE EFFECTIVE AS PER 46 CFR182.25-10, NO LATER THAN COMPLIANCE DATE._x001C_ _x001C_
Condition: Unknown
Due 13 May 1992
Resolved 13 May 1992
Lifesaving
Issued 13 May 1992
Resolved
REPLACE CARBIDE WATERLIGHT WITH APPROVED WATERLIGHT, AS REQUIRED BY 46 C.F.R 180.30-1(B), NO LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 13 May 1992
Resolved 13 May 1992
Fire Fighting
Issued 13 May 1992
Resolved
PROVIDE COPY OF FESCO SERVICING REPORT TO PROVE THAT TESTS WERE DONE, AS REQUIRED BY 46 C.F.R. 176.25-25(B), NO LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 13 May 1992
Resolved 13 May 1992