Records from 1995 to 2026. Most recent: inspection, 6 April 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 30
6 April 2026
COI Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8345365
8 April 2025
DAPI Audit · Hull Examination · Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8109616
12 March 2024
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7878669
11 April 2023
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7671090
31 March 2022
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7424363
17 March 2021
COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7188855
6 May 2020
Annual Inspection · DAPI Audit · Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6952069
10 April 2019
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6709768
14 December 2018
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6598043
11 April 2018
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6489400
3 April 2017
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6121676
13 April 2016
COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5848767
23 April 2009
Annual Inspection · Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3462284
17 April 2008
Deficiency Check · Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3179421
10 April 2007
Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2907406
19 March 2007
Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2895130
21 April 2006
COI Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2629758
20 April 2005
Annual Inspection · Hull Examination · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2318896
14 April 2004
Annual Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2000305
18 April 2003
Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1942169
9 April 2002
Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1628405
25 April 2001
COI Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1065375
26 April 2000
Re-Inspection · Hull Examination · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1391355
5 May 1999
Deficiency Check · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1369246
10 July 1998
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1129169
22 April 1998
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1124051
24 April 1997
Deficiency Check · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1109360
24 April 1996
Re-Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1086027
24 May 1995
Hull Examination · Initial Construction-Excluding Oversight · Initial Certification · Plan Review "T" Boat
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1355273
20 April 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 214425
Communications › Alarms/Indicators › Bilge Alarm
Issued 23 April 2009
Resolved
Properly install visual indicator for automatic bilge pumps IAW 46 CFR 182.530.
Due 23 May 2009
Resolved 10 June 2009
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 23 April 2009
Resolved
Provide documented proof that MOB and FF drills are being conducted IAW 46 CFR 185.520/.524
Due 23 May 2009
Resolved 10 June 2009
Fire Fighting › Ventilation Systems › Ducts
Issued 23 April 2009
Resolved
Properly replace fractured ventilation duct on port quarter IAW 46 CFR 182
Due 23 May 2009
Resolved 10 June 2009
Communications › Alarms/Indicators › Bilge Alarm
Issued 23 April 2009
Resolved
Properly repair dim fwd bilge high level alarm or replace IAW 46 CFR 182/176
Due 23 May 2009
Resolved 10 June 2009
Documentation › Markings/Placards › Warning Signs
Issued 23 April 2009
Resolved
Properly install blower motor warning signs IAW 46 CFR 182.460
Due 23 May 2009
Resolved 10 June 2009
Operations/Management › Drills/Instruction › Not Conducted
Issued 17 April 2008
Resolved
Make vessel crew available for MOB and FF drills.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 April 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 April 2008
Resolved
Update first aid kit.
Due 24 April 2008
Resolved 24 April 2008
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 17 April 2008
Resolved
Properly place vessel name on hull.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 April 2008
Lifesaving › Lifebuoys › Serviceable
Issued 19 March 2007
Resolved
Repair or replace life ring.
Action required: 705 - Other - as specified
Resolved 10 April 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 5 April 2005
Resolved
Provide and install placard at operating console IWO fixed CO2 firefighting system discharge handle and battery switches directing all power be secured prior to fixed F/F system discharge. This will ensure that mechanical ventilation for the Eng. compartment is secured prior to CO2 discharge. 46 CFR 181.410(b)(ii)(10). Correct to the satisfaction of the attending MI prior to PAX carry.
Condition: Unknown
Due 5 May 2005
Resolved 20 April 2005
Resolution: Corrected.
Fire Fighting › Fire Bucket › Availability
Issued 5 April 2005
Resolved
Provide fire bucket. PORMS CID Policy 04-01 dtd 01FEB02. Correct to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 5 May 2005
Resolved 20 April 2005
Resolution: Corrected.
Lifesaving › Lifejacket/PFD (Type V) › Retroreflective Material
Issued 5 April 2005
Resolved
Install retroreflective material on all PFD's IAW NVIC 01-87. PORMS CID Policy 04-01 dtd 01FEB02. Correct to the satisfaction of the attending Marine Inspector prior to PAX carry.
Condition: Improper Installation
Due 5 May 2005
Resolved 20 April 2005
Resolution: Corrected.
Documentation › Markings/Placards › Lifejacket Placard
Issued 5 April 2005
Resolved
Provide and install PFD donning placard as discussed. 46 CFR 185.516. Correct to the satisfaction of the attending Marine inspector.
Condition: Unknown
Due 5 May 2005
Resolved 20 April 2005
Resolution: Corrected.
Engineering › Gasoline Engine (propulsion)
Issued 14 April 2004
Resolved
Provide vent closures. 46 CFR 182.460(l). Correct to the satisfaction of the attending [name withheld]: Ventilation closure
Condition: Improper/Lack of Maintenance
Due 14 May 2004
Resolved 17 May 2004
Resolution: Corrected.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 14 April 2004
Resolved
Renew fuel tank vent hose. 46 CFR 182.450(g). Correct to the satisfaction of the attending MI.
Condition: Improper/Lack of Maintenance
Due 14 May 2004
Resolved 17 May 2004
Resolution: Corrected.
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 14 April 2004
Resolved
Install drip screen/pan at fuel strainer. 46 CFR 182.455(b)(6). Correct to the satisfaction of the attending MI.
Condition: Improper Installation
Due 14 May 2004
Resolved 17 May 2004
Resolution: Corrected.
Construction/Loadline › Hull
Issued 14 April 2004
Resolved
Drill stop fracture IWO forward engine room hatch opening on port and starboard sides. Correct to the satisfaction of the attending [name withheld]: Deck plate at E/R Hatch
Condition: Design Flaw
Due 14 May 2004
Resolved 17 May 2004
Resolution: Completed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 April 2004
Resolved
Install navigation lights as required by 46 CFR 183.420/CID Policy 04-01. Correct to the satisfaction of the attending Marine Inspector.
Due 30 April 2005
Resolved 20 April 2005
Resolution: Corrected.
Navigation › Collision/Grounding Avoidance
Issued 14 April 2004
Resolved
Provide horn. NAVRUL. Correct to the satisfaction of the attending marine inspector. LEGACY COMPONENT DESC: Horn
Condition: Improper/Lack of Maintenance
Due 14 May 2004
Resolved 17 May 2004
Resolution: Corrected.
Accommodation/Occupational Safety › Occupational Safety
Issued 14 April 2004
Resolved
Provide portable lights. 46 CFR 183.430/CID Policy 04-01. Correct to the satisfaction of the attending marine inspector. LEGACY COMPONENT DESC: Portable lights
Condition: Unknown
Due 14 May 2004
Resolved 17 May 2004
Resolution: Corrected.
Documentation › Markings/Placards
Issued 14 April 2004
Resolved
Provide PFD donning placards. 46 CFR 185.516. Correct to the satisfaction of the attending marine inspector. LEGACY COMPONENT DESC: PFD Donning Placard
Condition: Improper Installation
Due 14 May 2004
Resolved 17 May 2004
Resolution: Corrected.
Accommodation/Occupational Safety › Medical/First Aid
Issued 14 April 2004
Resolved
Renew ammonia inhalants and eye wash. 46 CFR 184.710. Correct to the satisfaction of the attending marine inspector. LEGACY COMPONENT DESC: First aid kit
Condition: Improper/Lack of Maintenance
Due 14 May 2004
Resolved 17 May 2004
Resolution: Corrected.
Fire Fighting
Issued 25 April 2001
Resolved
Replace broken port portable extinguisher bracket
Condition: Unknown
Due 22 May 2001
Resolved 16 June 2001
Fire Fighting
Issued 25 April 2001
Resolved
Seal all engine room penetrations for fixed fire fighting and provide foam engine room ventilation closures.
Condition: Unknown
Due 22 May 2001
Resolved 16 June 2001
Unknown
Issued 25 April 2001
Resolved
Replace expired eye wash and aspirin
Condition: Unknown
Due 22 May 2001
Resolved 16 June 2001
Unknown
Issued 25 April 2001
Resolved
Label fuel on/off switches
Condition: Unknown
Due 22 May 2001
Resolved 16 June 2001
Engineering
Issued 25 April 2001
Resolved
Remove gas sensor toggle switch
Condition: Unknown
Due 13 June 2001
Resolved 16 June 2001
Lifesaving
Issued 25 April 2001
Resolved
Replace missing 3 PFD (adult)
Condition: Unknown
Due 22 May 2001
Resolved 16 June 2001
Construction/Loadline
Issued 26 April 2000
Resolved
LABEL HIGH LEVEL BILGE ALARM
Condition: Unknown
Due 19 June 2000
Resolved 29 July 2000
Lifesaving
Issued 26 April 2000
Resolved
PERMANENTLY UNTIE LIFE RING LINE
Condition: Unknown
Due 19 June 2000
Resolved 29 July 2000
Lifesaving
Issued 26 April 2000
Resolved
PROVIDE LIFE JACKET DONNING INSTRUCTIONS
Condition: Unknown
Due 19 June 2000
Resolved 29 July 2000
Lifesaving
Issued 26 April 2000
Resolved
PROVIDE OPERATIONAL TESTING AND FIRE/MAN OVERBOARD DRILLS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR
Condition: Unknown
Due 19 June 2000
Resolved 29 July 2000
Engineering
Issued 26 April 2000
Resolved
LOWER GAS SENSORS
Condition: Unknown
Due 19 June 2000
Resolved 29 July 2000
Fire Fighting
Issued 26 April 2000
Resolved
PROVIDE VENTILATION CLOSURES FOR ENGINE SPACE VENTILATION
Condition: Unknown
Due 19 June 2000
Resolved 29 July 2000
Documentation
Issued 5 May 1999
Resolved
PROVIDE ONBOARD LIFEJACKET DONNING INSTRUCTIONS, EMERGENCY BROADCAST INSTRUCTIONS AND EMERGENCY CHECK OFF PLACARD
Condition: Unknown
Due 8 June 1999
Resolved 25 June 1999
Engineering
Issued 24 April 1997
Resolved
INSTALL DRIP PANS, FITTED WITH 30 X 30 MESH FLAME SCREEN, UNDER EACH GASOLINE FUEL FILTER.
Condition: Unknown
Due 20 June 1997
Resolved 20 June 1997
Documentation
Issued 24 April 1996
Resolved
Provide copy of Certificate of Documentation for vessel. Vessel cannot carry passenger until new C.O.D. is on board this vessel.
Condition: Unknown
Due 29 May 1996
Resolved 30 May 1996
Documentation
Issued 24 May 1995
Resolved
Provide proof vessel has been documented.
Condition: Unknown
Due 24 May 1995
Resolved 24 May 1995