Records from 1985 to 2025. Most recent: inspection, 28 May 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 66
28 May 2025
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8145559
30 September 2024
Deficiency Check · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8010386
5 June 2024
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7927121
4 May 2023
Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7656449
15 September 2022
In-Service Inspection · Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7564261
7 July 2022
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7498719
19 May 2021
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7201002
28 September 2020
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7064387
14 July 2020
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6953685
19 April 2019
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6651319
11 October 2018
Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6558979
23 July 2018
Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6488124
12 April 2018
DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6381279
9 May 2017
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6141694
26 October 2016
Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6023661
21 April 2016
Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5858545
9 May 2014
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4854050
2 March 2010
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3688332
23 March 2009
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3438259
26 November 2008
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3369734
20 November 2008
Examination of Repairs
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3366790
19 May 2008
Simplified Stability Test · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3189765
19 May 2008
Simplified Stability Test · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3357969
26 March 2008
COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3171511
18 December 2007
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3117377
16 October 2007
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3080789
25 April 2006
COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2632477
22 February 2006
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2589228
10 June 2005
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2385155
16 March 2004
Annual Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2024682
4 March 2004
Hull Examination · Internal Structural Exam
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2017860
19 June 2003
Annual Inspection · MARPOL Annex V Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1819167
9 September 2002
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1671619
4 February 2002
Internal Structural Exam · Hull Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1495430
15 June 2001
MARPOL Annex V Examination · COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1448347
30 March 2000
Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 816733
16 March 2000
COI Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1426349
8 March 2000
Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1378960
25 February 2000
Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1438981
10 May 1999
Plan Review "T" Boat
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1130497
6 May 1999
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 4891
6 May 1999
Damage Survey
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1410095
10 March 1999
Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 803873
27 November 1998
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 212804
4 March 1998
Hull Examination · Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1372148
26 March 1997
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 49925
14 March 1997
MARPOL Annex V Examination · COI Inspection · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1104632
9 October 1996
Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 840921
29 March 1996
Re-Inspection · Hull Examination · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1085790
25 August 1995
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 16641
22 March 1995
Re-Inspection · MARPOL Annex V Examination · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1186902
15 March 1994
Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1168690
26 March 1993
Hull Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1135045
20 March 1992
Re-Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 946455
15 March 1991
Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1251374
8 March 1990
Hull Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 909632
3 March 1989
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1197671
9 December 1988
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1350392
3 March 1988
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1198308
2 December 1987
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1311862
13 March 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1321657
25 February 1987
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1309669
3 December 1986
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1001273
9 January 1986
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 997186
31 October 1985
Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 986051
9 January 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 977696
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 28 May 2025
Resolved
Bilge high water alarm visible portion of the stern compartment inop.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2025
Resolved 5 June 2025
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 May 2025
Resolved
Wood boat. Angel hair in overhead in engine room. Instructed to remove.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2025
Resolved 5 June 2025
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 28 May 2025
Resolved
Replace items in first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2025
Resolved 5 June 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 May 2025
Resolved
Stbd shaft was leaking excessively. Required replacement repair of packing on stbd shaft.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2025
Resolved 5 June 2025
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 28 May 2025
Resolved
Prove enrollment in a drug consortium.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2025
Resolved 5 June 2025
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 28 May 2025
Resolved
A beam in the overhead in the tank compartment had come loose. It appears that this beam was sistered to another just aft of the hatch. Loose beam and sister beam appear structurally sound. Required to affix.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2025
Resolved 5 June 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 June 2024
Resolved
Tighten packing for port and starboard shaft seals.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2024
Resolved 18 June 2024
Resolution: fixed
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 5 June 2024
Resolved
Re-label oars with vessel name.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2024
Resolved 18 June 2024
Resolution: fixed
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 May 2023
Resolved
Prove proper operation of mast headlight.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 4 May 2023
Resolved 4 May 2023
Resolution: Corrected on the spot.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 4 May 2023
Resolved
Renew FCC Station and Safety Radio certs prior to operating more than 1000feet from shore.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 4 June 2023
Resolved 19 September 2023
Resolution: Provided current cert.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 September 2022
Resolved
Witnessed excessive scale on tank top required rep descale and make available for inspection. Prior to credit DD.
Action required: 705 - Other - as specified
Due 15 September 2022
Resolved 15 September 2022
Resolution: Sat inspection after de-scale.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 15 September 2022
Resolved
Witnessed excessive angel hair on wood structures in engine room, req'd rep clean and remove excess and make available for inspection. Prior to credit DD.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 15 September 2022
Resolved 15 September 2022
Resolution: Cleaned and available all structures remained sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 July 2022
Resolved
Complete wood hull fastener pull to the satisfaction of the attending Marine Inspector prior to carrying passengers beyond 01 October 2022.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2022
Resolved 12 July 2022
Resolution: Converted requirement to special note to be reviewed at next dry dock.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 7 July 2022
Resolved
Prior to operating more than 1 mile from shore on other than day light operations with more than 45 total persons onboard complete wood hull fastener pull to the satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2022
Resolved 12 July 2022
Resolution: Converted requirement to special note to be reviewed at next dry dock.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 May 2021
Resolved
Renew EPIRB battery and hydrostatic release prior to operating beyond 3 nautical miles.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 19 May 2021
Resolved 2 June 2021
Resolution: Renewed Epirb battery and hydro.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 19 May 2021
Resolved
Repair indicating light on bilge alarm panel for aft space.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 May 2021
Resolved 2 June 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 May 2021
Resolved
Double up all hose clamps for R/W hoses in engine room.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2021
Resolved 2 June 2021
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 14 July 2020
Resolved
Stern railing where the railing lifts for Man Over Board recovery was identified missing 1 concourse where the gap between the top railing and the gunwhale was in excess of 12 inches.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2020
Resolved 20 July 2020
Resolution: Chain installed to evenly space concourses to less than 12" IAW old T
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 14 July 2020
Resolved
Fire pump on the vessel's STBD MDE using PTO was identified as inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2020
Resolved 20 July 2020
Resolution: Fire pump dissasembled, serviced and rebuiilt. Fire pump operational. Additionally, O/O states teh FP will be run monthly as a part of routine maintenance.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 July 2020
Resolved
PORT steering bracket identified as loose when steering underway. Issued req. to repair steering temporarily with new hardware and to stiffen using gussets or knees.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2020
Resolved 20 July 2020
Resolution: O/O reported hardware for the steering system was wasted and replaced. O/O stated he will shore up at next haul out.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 19 April 2019
Resolved
Provide charts and navigation publications for intended voyage. 46CFR184.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2019
Resolved 10 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 19 April 2019
Resolved
Emergency instructions must be posted at the operating station. 46CFR185.510
Action required: 10 - Deficiency Rectified
Due 19 April 2019
Resolved 10 July 2019
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 19 April 2019
Resolved
Update first aid kit to meet the requirements listed in 46CFR160.041
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2019
Resolved 10 July 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 April 2019
Resolved
Replace spliced wiring for the bilge/fire pump.
46CFR183.340(g)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2019
Resolved 10 July 2019
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 12 April 2018
Resolved
Replace buoy light for lifefloat. 46CFR180.175(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2018
Resolved 23 July 2018
Resolution: O/O replaced light buoy light
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 April 2018
Resolved
Survey shipboard AC/DC system and clean up and update as needed. 46CFR183.100
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2018
Resolved 23 July 2018
Resolution: O/O updated electrical installation, reouted DC loads to bridge/nav. properly wired breaker boxes and removed failed wiring from service
Construction/Loadline › Hull › Keel
Issued 26 October 2016
Resolved
Replace keel drift pins in engine compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 1 November 2016
Resolution: MI attended vessel and witnessed that new drift pins had been installed.
Construction/Loadline › Hull › Transverse Frame
Issued 26 October 2016
Resolved
Replace floor timber bolts in space #2 and provide maintenance plan for other compartments.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 1 November 2016
Resolution: MI attended vessel and witnessed that new floor timber bolts had been installed.
Construction/Loadline › Structures › Superstructure
Issued 26 October 2016
Resolved
Fix port bow main deck railing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 1 November 2016
Resolution: MI attended vessel and witnessed that the railing was repaired
Engineering › Steering Gear System › Rudder Stock
Issued 26 October 2016
Resolved
Observe portside rudder stock underway to observe for leaks.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 1 November 2016
Resolution: MI attended vessel and witnessed a satisfactory underway test of rudder stock
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 9 May 2014
Resolved
Service Fire extinguisher
Condition: Placed in Improper Service
Due 9 May 2014
Resolved 9 May 2014
Resolution: Serviced
Communications › Radio Communications › EPIRB
Issued 9 May 2014
Resolved
Register EPIRB
Condition: Placed in Improper Service
Due 9 May 2014
Resolved 10 May 2014
Resolution: Registered
Documentation › Certificates/Documents › Stability Letter
Issued 9 May 2014
Resolved
Post Stability Letter
Condition: Improper Installation
Due 9 May 2014
Resolved 9 May 2014
Resolution: Corrected on the spot
Stability › Incline Test › General
Issued 26 March 2008
Resolved
Passengers not allowed on upper deck until a stability verification can be conducted.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 April 2008
Resolved 19 May 2008
Resolution: Stability test conducted
Accommodation/Occupational Safety › Potable Water System › General
Issued 26 March 2008
Resolved
Repair various potable water leaks.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2008
Resolved 30 April 2008
Resolution: Leaks repaired
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 18 December 2007
Resolved
Replace all exterior shaft bearings due to excessive wear. Possible shaft misalignment on Port shaft. Investigate cause.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 January 2008
Resolved 18 January 2008
Resolution: Owner/ maintenance personnel investigated and concluded that indications of misalignment was simply due to combination of excessively worn strut and log bearings. All bearings replaced.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 16 October 2007
Resolved
Find COI and post.
Condition: Unknown
Due 16 October 2007
Resolved 16 October 2007
Resolution: COI found later in inspection - cleared on spot
Documentation › Certificates/Documents › Stability Letter
Issued 16 October 2007
Resolved
Find and post stability letter.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 November 2007
Resolved 18 December 2007
Resolution: Resolved as boat was being sold. New Stability test was conducted on 19 May 08.
Operations/Management › Drills/Instruction › Not Conducted
Issued 16 October 2007
Resolved
Conduct and record all required drills. No proof existed that any drills had been conducted since 2005.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 November 2007
Resolved 26 March 2008
Resolution: Resolved due to new owner and COI.
Communications › Radio Communications › EPIRB
Issued 16 October 2007
Resolved
Replace hydrostatic release for EPIRB. Route restricted to within 3 NM from shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 November 2007
Resolved 26 March 2008
Resolution: New owner and COI.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 16 October 2007
Resolved
Obtain servicing report for installed engineroom CO2.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 October 2007
Resolved 26 March 2008
Resolution: New owner and COI.
Engineering › Fuel Oil Service System › Valve
Issued 16 October 2007
Resolved
Install F/O shut off valve at generator.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 November 2007
Resolved 26 March 2008
Resolution: New owner and COI.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 16 October 2007
Resolved
Install correctly sized bracket for engineroom fire extinguisher
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 October 2007
Resolved 26 March 2008
Resolution: New Owner and COI.
Engineering › Fuel Oil Service System › Piping
Issued 16 October 2007
Resolved
Repair F/O leak on STBD main engine in area of fuel pump/inline filter
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 October 2007
Resolved 26 March 2008
Resolution: New owner and COI.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 October 2007
Resolved
Install metal wire brackets throughout vessel IAW 46 CFR part 183
Action required: 705 - Other - as specified
Due 16 November 2007
Resolved 26 March 2008
Resolution: New owner and COI.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 16 October 2007
Resolved
Secure and lock msd discharge ovbd valve. Valve closed on spot, but found open by inspector and sewage found flowing freely into marina.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 October 2007
Resolved 26 March 2008
Resolution: New owner and COI.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 June 2005
Resolved
Provide aspirin, eyewash, and ammonia inhalants prior to 24 Jun 05.
Due 24 June 2005
Resolved 4 December 2005
Resolution: Per ltr fm O/O, ltr scanned into documents for this activity.
Documentation › Markings/Placards › Warning Signs
Issued 10 June 2005
Resolved
Provide emergency broadcast placard prio to 24 Jun 05.
Due 24 June 2005
Resolved 4 December 2005
Resolution: Per ltr fm O/O, ltr scanned into documents for this activity.
Communications › Alarms/Indicators › Bilge Alarm
Issued 10 June 2005
Resolved
Prove proper operation of bilge high water level alarm in compartment #5 prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 December 2005
Resolution: O/O claims that this was corrected immediately, and a fax was sent attesting to this. However, if we received the fax, it was misplaced, therefore the letter sent on 04 Dec 05 is the first proof that this def was corrected.
Engineering › Fuel Oil Service System
Issued 16 March 2004
Resolved
Renew complete fuel line to racor fuel filter for the generator with proper fuel lines prior to operating. LEGACY COMPONENT DESC: Piping
Due 16 March 2004
Resolved 19 March 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 16 March 2004
Resolved
Alarm panel for the fixed Co2 system dos not work in test mode, repair prior to operating. LEGACY COMPONENT DESC: Operating Controls
Due 16 March 2004
Resolved 19 March 2004
Electrical › Electric Supply System (service)
Issued 16 March 2004
Resolved
Provide covers for all engineroom batteries prior to operating. LEGACY COMPONENT DESC: Battery Installation
Due 16 March 2004
Resolved 19 March 2004
Electrical › Lighting (service)
Issued 16 March 2004
Resolved
Provide covers for all lighting in the engineroom prior to opertaing. LEGACY COMPONENT DESC: Lighting Fixture
Due 16 March 2004
Resolved 19 March 2004
Lifesaving › Lifebuoys
Issued 16 March 2004
Resolved
Provide waterlight w/ lanyard and clip for the life bouy prior to operating. LEGACY COMPONENT DESC: Self-igniting Lights
Due 16 March 2004
Resolved 19 March 2004
Engineering › Steering Gear System
Issued 16 March 2004
Resolved
Repair forward bulkhead of lazerette along with the steering linkage support prior to operating. LEGACY COMPONENT DESC: Linkage
Due 16 March 2004
Resolved 19 March 2004
Documentation › Certificates/Documents
Issued 16 March 2004
Resolved
Post stability letter when located. LEGACY COMPONENT DESC: Stability Letter
Due 16 April 2004
Resolved 19 March 2004
Fire Fighting › Fire Pumps
Issued 16 March 2004
Resolved
Provide plans for newly installed electric fire pump prior to using. LEGACY COMPONENT DESC: Arrangement
Due 16 April 2004
Resolved 19 March 2004
Accommodation/Occupational Safety › Medical/First Aid
Issued 9 September 2002
Resolved
First Aid kit incomplete, provide complete kit. LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 September 2002
Resolved 11 September 2002
Operations/Management › Drills/Instruction
Issued 9 September 2002
Resolved
No record of conducting drills, Captain states he has been with company and has not done drills. Conduct and log drills prior to carrying passengers. LEGACY COMPONENT DESC: Man Overboard Recovery
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 September 2002
Resolved 11 September 2002
Operations/Management › Drug and Alcohol Testing
Issued 9 September 2002
Resolved
Crew list not up to date, Captain not on list and has not had preemployment. Provide up to date crew list and preemployment record for each employee. Above item to be completed prior to carrying passengers. LEGACY COMPONENT DESC: Testing, Pre-employment
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 September 2002
Resolved 11 September 2002
Fire Fighting › Fire Pumps
Issued 9 September 2002
Resolved
Fire/bilge pump inop due to faualty seal. Repair/renew prior to carrying passengers. LEGACY COMPONENT DESC: Gland Sealing
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 September 2002
Resolved 11 September 2002
Stability › Watertight Integrity
Issued 9 September 2002
Resolved
Gaskets missing from all watertight hatches. Make all hatches watertight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 September 2002
Resolved 15 October 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 9 September 2002
Resolved
Two children life jackets missing retro. Repair/renew vsl resticted to 70 total people.. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 September 2002
Resolved 15 October 2002
Communications › Radio Communications
Issued 9 September 2002
Resolved
Battery for EPIRB expired 7/2002. Repar/renew vsl resticted to three miles from shore. LEGACY COMPONENT DESC: EPIRB
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2002
Resolved 15 October 2002
Lifesaving › Hand Flares
Issued 9 September 2002
Resolved
4 smoke flares outdated. Repair/renew vsl restricted to trips of less than 30 minutes. LEGACY COMPONENT DESC: Quantity
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 September 2002
Resolved 11 September 2002
Stability › Weathertight Integrity
Issued 9 September 2002
Resolved
Widow in accomdation area broke. Repair/renew.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 September 2002
Resolved 11 September 2002
Engineering › Generator (propulsion/auxiliary-electric)
Issued 9 September 2002
Resolved
Generator voltage and amp gauge inop. Repair/renew LEGACY COMPONENT DESC: Indicator Circuitry
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 September 2002
Resolved 15 October 2002
Construction/Loadline
Issued 15 June 2001
Resolved
Vsl leaks in several areas around chine. vsl restricted to lbs, rivers for 2 weeks so another U/W trip can verify leaks are stopped.
Condition: Unknown
Due 7 September 2001
Resolved 7 September 2001
Navigation
Issued 15 June 2001
Resolved
Rudder posts packing glan leaks excessive. Repair/renew.
Condition: Unknown
Due 7 September 2001
Resolved 7 September 2001
Construction/Loadline
Issued 15 June 2001
Resolved
2nd plank port side above chine, fwd of 2nd frame from aft bulkhead of msd compartment needs caulking. Repair/renew
Condition: Unknown
Due 7 September 2001
Resolved 7 September 2001
Construction/Loadline
Issued 15 June 2001
Resolved
Hole in main deck in accomdation area above E/R needs to be sealed. Repair/renew.
Condition: Unknown
Due 7 September 2001
Resolved 7 September 2001
Construction/Loadline
Issued 15 June 2001
Resolved
Wires penetrate W/T blk need to be sealed.
Condition: Unknown
Due 7 September 2001
Resolved 7 September 2001
Engineering
Issued 15 June 2001
Resolved
Fuel fill hoses require new hose clamps and a grounding wire from fill connection to tank. Repair/renew
Condition: Unknown
Due 7 September 2001
Resolved 7 September 2001
Navigation
Issued 15 June 2001
Resolved
No rules of the road, coast pilot and light list. Place on board prior to getting underway.
Condition: Unknown
Due 7 September 2001
Resolved 7 September 2001
Construction/Loadline
Issued 15 June 2001
Resolved
Prior to carrying passengers address leaks (item 4 issued 15JUN01) in shaftlogs, butt block E/R and area around chine. Leaks worse than last inspection.
Condition: Unknown
Due 7 September 2001
Resolved 7 September 2001
Electrical
Issued 15 June 2001
Resolved
Dead ended wire in fuel tank compartment. Remove wire to source.
Condition: Unknown
Due 7 September 2001
Resolved 7 September 2001
Construction/Loadline
Issued 15 June 2001
Resolved
Butt block port side 1st aft of fwd blk in 2nd compartment missing fastener. Repair/renew next drydock
Condition: Unknown
Due 7 September 2001
Resolved 7 September 2001
Documentation
Issued 15 June 2001
Resolved
Submit plans for electrical installation on upper deck (deck lights).
Condition: Unknown
Due 15 October 2001
Resolved 15 October 2001
Documentation
Issued 15 June 2001
Resolved
Certificates not posted. Post all certificates.
Condition: Unknown
Due 7 September 2001
Resolved 7 September 2001
Construction/Loadline
Issued 15 June 2001
Resolved
WT hatches not secured to vsl. Repair/renew
Condition: Unknown
Due 7 September 2001
Resolved 7 September 2001
Lifesaving
Issued 15 June 2001
Resolved
life jacket storage needs to be marked. Mark storage area with quanity andcontents.
Condition: Unknown
Due 7 September 2001
Resolved 7 September 2001
Construction/Loadline
Issued 16 March 2000
Resolved
PROVE OPERATION OF HIGHWATER BILGE ALARM IN THE LAZARETTE.
Condition: Unknown
Due 24 March 2000
Resolved 30 March 2000
Lifesaving
Issued 16 March 2000
Resolved
PROVIDE ONE TYPE 1 CHILDS PFD.
Condition: Unknown
Due 24 March 2000
Resolved 30 March 2000
Electrical
Issued 8 March 2000
Resolved
PROPERLY SECURE AFT 3 LIGHTS ON UPPER DECK.
Condition: Unknown
Due 8 March 2000
Resolved 8 March 2000
Electrical
Issued 8 March 2000
Resolved
PROPERLY WIRE AND SECURE JUNCTION BOX SERVING ELECTRIC WINCH IN CRASH COMPT.
Condition: Unknown
Due 8 March 2000
Resolved 8 March 2000
Navigation
Issued 8 March 2000
Resolved
FREEUP STEERING CHAIN IN #3 COMPT.
Condition: Unknown
Due 8 March 2000
Resolved 8 March 2000
Engineering
Issued 8 March 2000
Resolved
RENEW ALL FLAME SCREENS.
Condition: Unknown
Due 8 March 2000
Resolved 8 March 2000
Fire Fighting
Issued 25 February 2000
Resolved
POST THE THREE SIGNS PROVIDED BY THE FIRE SYSTEM SERVICE COMPANY AS FOLLOWS: GENERAL OPERATION INSTRUCTIONS @ WHEELHOUSE ALARM PANEL; "RELEASE CO2" INSTRUCTION @ CYL OPERATING CONTROL; & EVACUATE SPACE SIGN @ PROTECTEDSPACE ENTRANCE.
Condition: Unknown
Due 25 February 2000
Resolved 25 February 2000
Fire Fighting
Issued 10 May 1999
Resolved
CONDUCT INSTALLATION INSPECTION AND TESTING OF CO2 SYSTEM/PIPING.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Construction/Loadline
Issued 6 May 1999
Resolved
REFASTEN ALL BOTTOM PLANKS TO LAST 2 FRAMES IN COMPT #5, PORTSIDE. ADD ADDITIONAL FASTENERS, DO NOT RELY ON OLD FASTENERS AS THEY HAVE PULLED LOOSE.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Construction/Loadline
Issued 6 May 1999
Resolved
REFASTEN ALL PLANKS TO FRAMES #1 THROUGH #4 IN LAZ. ADD ADDITIONAL FASTENERS, DO NOT RELY ON EXISTING NAILS AS THEY HAVE PULLED LOOSE.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Construction/Loadline
Issued 6 May 1999
Resolved
CROP AND RENEW 1st and 2nd PLANKS OUT FROM GARBOARD, PORTSIDE IWO STRUT.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Engineering
Issued 6 May 1999
Resolved
PROVE TO THE SATISFACTION OF THE MARINE INSPECTOR THAT THE PORT SHAFT IS STRAIGHT.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Engineering
Issued 6 May 1999
Resolved
RENEW PORT PROP.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Fire Fighting
Issued 10 March 1999
Resolved
PROVIDE AND INSTALL THREADED FTG FOR END OF FIRE FIGHTING HOSE. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 15 March 1999
Resolved 17 March 1999
Electrical
Issued 10 March 1999
Resolved
LABEL ALL BREAKERS AND FUSES IN E/R.
Condition: Unknown
Due 24 March 1999
Resolved 31 March 1999
Lifesaving
Issued 10 March 1999
Resolved
PROVE OPERATION OF ALL FLOATING WATER LIGHTS. DO NOT USE ALAKALINE BATTERIES. NO NIGHT OPERATION UNTIL CLEARED.
Condition: Unknown
Due 15 March 1999
Resolved 17 March 1999
Electrical
Issued 10 March 1999
Resolved
REMOVE DEAD ENDED WIRING UNDER CONSOLE ON BRIDGE.
Condition: Unknown
Due 24 March 1999
Resolved 31 March 1999
Electrical
Issued 10 March 1999
Resolved
PROVIDE 2 WORKING FLASHLIGHTS.
Condition: Unknown
Due 15 March 1999
Resolved 17 March 1999
Documentation
Issued 10 March 1999
Resolved
PROVE COMPLIANCE W/ CG DRUG TESTING REGS.
Condition: Unknown
Due 15 March 1999
Resolved 17 March 1999
Lifesaving
Issued 10 March 1999
Resolved
PROVIDE AND POST PFD DONNING PLACARD FOR HORSE COLLAR TYPE PFDs.
Condition: Unknown
Due 15 March 1999
Resolved 17 March 1999
Navigation
Issued 10 March 1999
Resolved
REPAIR SHAFT/SHIM SHAFT FOR WHEEL IN PILOT HOUSE.
Condition: Unknown
Due 24 March 1999
Resolved 31 March 1999
Electrical
Issued 10 March 1999
Resolved
REMOVE ALL DEAD ENDED WIRING AND UNUSED BREAKER BOXES AND FUSE BOXES IN E/R.
Condition: Unknown
Due 24 March 1999
Resolved 31 March 1999
Fire Fighting
Issued 10 March 1999
Resolved
PROVIDE 1 B-II EXTINGUISHER. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 15 March 1999
Resolved 17 March 1999
Navigation
Issued 10 March 1999
Resolved
SECURE STEERING BOX TO VESSEL IN LAZ. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 15 March 1999
Resolved 17 March 1999
Fire Fighting
Issued 10 March 1999
Resolved
NOTCH OUT WOOD AROUND STBD FUEL SHUT OFF TO ALLOW FOR FREE MOVEMENT.
Condition: Unknown
Due 15 March 1999
Resolved 17 March 1999
Lifesaving
Issued 4 March 1998
Resolved
PROVIDE CREW FOR DRILLS.
Condition: Unknown
Due 4 April 1998
Resolved 23 April 1998
Electrical
Issued 4 March 1998
Resolved
LABEL ALL BREAKERS/FUSES/SWITCHES IN E/R.
Condition: Unknown
Due 4 April 1998
Resolved 23 April 1998
Electrical
Issued 4 March 1998
Resolved
REMOVE ALL DEAD ENDED WIRING IN E/R.
Condition: Unknown
Due 4 April 1998
Resolved 23 April 1998
Lifesaving
Issued 14 March 1997
Resolved
REGISTER AND INSTALL EPIRB. ROUTE RESTRICTED TO L, B, AND S UNTIL CORRECTED.
Condition: Unknown
Due 23 July 1997
Resolved 23 July 1997
Lifesaving
Issued 14 March 1997
Resolved
RENEW 60 FEET SEA PAINTER FOR RING BUOY PRIOR TO SAILING. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 April 1997
Resolved 25 April 1997
Lifesaving
Issued 14 March 1997
Resolved
COMPLETE REMARKING OF LIFE SAVING EQUIPMENT.
Condition: Unknown
Due 23 July 1997
Resolved 23 July 1997
Lifesaving
Issued 14 March 1997
Resolved
CONDUCT AN UNDERWAY EXAM.
Condition: Unknown
Due 23 July 1997
Resolved 23 July 1997
Lifesaving
Issued 14 March 1997
Resolved
POST FCC EMERGENCY INSTRUCTIONS.
Condition: Unknown
Due 23 July 1997
Resolved 23 July 1997
Lifesaving
Issued 14 March 1997
Resolved
PROVIDE A TOTAL OF 6 ORANGE AND 6 RED DISTRESS SIGNALS. VESSEL NOT TO OPERATE WITH PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 28 March 1997
Resolved 25 April 1997
Engineering
Issued 14 March 1997
Resolved
REPAIR STBD ENGINE SHUTDOWN CABLE.
Condition: Unknown
Due 23 July 1997
Resolved 23 July 1997
Fire Fighting
Issued 14 March 1997
Resolved
MAINTAIN MONTHLY INSPECTION RECORDS OF FIRE EXTINGUISHERS.
Condition: Unknown
Due 23 July 1997
Resolved 23 July 1997
Electrical
Issued 29 March 1996
Resolved
LABLE FUSES & CIRCUIT BREAKERS.
Condition: Unknown
Due 29 March 1996
Resolved 29 March 1996
Construction/Loadline
Issued 29 March 1996
Resolved
RENEW ROTTED AFT MAIN DECK PLANKING IWO TEMPORARY REPAIR PRIOR TO 1997 OPERATING SEASON. ( NOT LATER THAN 31MAR97.)
Condition: Unknown
Due 29 March 1996
Resolved 29 March 1996
Construction/Loadline
Issued 29 March 1996
Resolved
CLOSE HOLE IN TOP CTR OFR AFT BHD OF COMPT FWD OF ENGINE ROOM.
Condition: Unknown
Due 29 March 1996
Resolved 29 March 1996
Fire Fighting
Issued 8 March 1990
Resolved
HYDRO TEST BII FIRE EXT.
Condition: Unknown
Due 8 March 1990
Resolved 8 March 1990
Construction/Loadline
Issued 8 March 1990
Resolved
REFASTENED ALL TRANSVERSE BHDS.
Condition: Unknown
Due 8 March 1990
Resolved 8 March 1990
Lifesaving
Issued 8 March 1990
Resolved
RENEWED ALL DISTRESS SIGNALS.
Condition: Unknown
Due 8 March 1990
Resolved 8 March 1990
Construction/Loadline
Issued 8 March 1990
Resolved
REFASTENED & CAULKED A BUTT BLOCK ON STBD CHINE #2 COMPT.
Condition: Unknown
Due 8 March 1990
Resolved 8 March 1990
Engineering
Issued 3 March 1988
Resolved
PROVIDE 30 X 30 MESH SCREENS FOR FUEL TANK VENTS.
Condition: Unknown
Due 3 March 1988
Resolved 3 March 1988
Electrical
Issued 25 February 1987
Resolved
REMOVE ALL WIRE NUT CONNECTIONS IN ELECTRICAL SYSTEM AND REPLACE WITH APPROVED MARINE CONNECTORS.
Condition: Unknown
Due 25 February 1987
Resolved 25 February 1987
Engineering
Issued 25 February 1987
Resolved
REPLACE BILGE STRAINER IN AFT COMPARTMENT.
Condition: Unknown
Due 25 February 1987
Resolved 25 February 1987
Electrical
Issued 25 February 1987
Resolved
PROVIDE A CUT-OFF SWITCH FOR ENGINE ROOM BLOWERS WHICH ARE NOW WIRED DIRECTLY TO BATTERY OR REWIRE POWER SUPPLY FROM BATTERY SO THAT PRESENT CUT-OFF SWITCH WILL DISCONNECT SYSTEM
Condition: Unknown
Due 25 February 1987
Resolved 25 February 1987
Engineering
Issued 25 February 1987
Resolved
REPLACE PLASTIC CLIPS HOLDING AUXILIARY FUEL LINE IN FUEL TANK COMPARTMENT.
Condition: Unknown
Due 25 February 1987
Resolved 25 February 1987
Engineering
Issued 25 February 1987
Resolved
REPLACE RUBBER FILL HOSE BETWEEN MAIN DECK AND STARBOARD FUEL TANK.
Condition: Unknown
Due 25 February 1987
Resolved 25 February 1987