TAHOE FLYER

TAHOE FLYER is a 1996 passenger vessel (inspected). The Coast Guard has recorded 42 inspections since 1996, most recently in May 2025, along with 68 deficiencies.

Records from 1996 to 2025. Most recent: inspection, 12 May 2025.

Built
1996
Last inspected
12 May 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCW8914
440235
Flag
UNITED STATES
—
Maury page id
psix-440235

Inspections, by type

…with no type recorded6
Years with a record 27 calendar years (1996–2025)
The 42 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)100.0 ft × 20.0 ft × 5.0 ft
Registered tonnagegross 36 / net 36
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderYUBA CITY STEEL · YUBA CITY, CA, UNITED STATES · built 1996
Hull materialSteel
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portLAKE TAHOE, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 14 May 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it36 - Simplified, Gross Ton
36 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCW8914MMSI not assigned · expired · compulsorily equipped · granted 2 October 1996, cancelled 2 December 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 42

12 May 2025 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8118777
10 May 2024 Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7910058
4 May 2023 Deficiency Check · Internal Structural Exam · Underwater Inspection in lieu of Drydock · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7681292
5 May 2022 Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7440695
22 June 2021 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7234680
17 June 2020 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6974707
2 April 2020 Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6939652
24 July 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6767248
21 May 2018 Deficiency Check · Underwater Inspection in lieu of Drydock · Administrative Inspection · COI Inspection · In-Service Inspection · Internal Structural Exam · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6415544
16 November 2017 In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6314427
9 August 2017 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6233117
9 August 2016 Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5967058
2 September 2015 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5228546
17 July 2012 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4385587
15 August 2011 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4116433
5 May 2009 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3463985
14 May 2008 Hull Examination · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3211875
18 June 2007 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2968326
24 July 2006 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2727954
9 May 2006 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2650129
8 May 2006 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2639836
26 July 2005 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2431115
10 May 2004 COI Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2087529
20 May 2003 Annual Inspection · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1751935
1 April 2003 Drydock Extension
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1861704
6 August 2002 In-Service Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1658421
16 April 2002 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1603333
29 November 2001 Drydock Extension
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1362590
16 October 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1073803
23 April 2001 Drydock Extension · Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1064233
28 February 2000 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1408453
3 February 2000 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 701316
7 September 1999 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 782802
31 July 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 213855
31 July 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 217670
16 November 1998 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1364937
6 May 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 701315
6 October 1997 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1108095
29 June 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 89707
7 April 1997 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 788949
2 April 1997 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1104971
18 September 1996 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1096055

Deficiency record · 68

11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 12 May 2025 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. STBD lifefloat found damaged beyond repair. Replace to MI satisfaction. 46 CFR 176.808(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 12 June 2025
Resolution: Operator provided satisfactory photos of repaired lifefloat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 May 2024 Resolved
To continue to participate in the AHE program, vessel operators must conduct an annual hull condition assessment. 2024 hull assessment with 20 percent hull gauging not completed. 46 CFR 177.660(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2024
Resolved 27 January 2025
Resolution: Received 2024 AHE report; all satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 May 2024 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment. Bilge manifold was not labeled. 46 CFR 182.500(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2024
Resolved 29 May 2024
Resolution: Received photograph of bilge manifold properly labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 13 May 2024 Resolved
Each survival craft must be in good working order and ready for immediate use. Life floats require maintenance IAW manufacturer's instructions. 46 CFR 185.700(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2024
Resolved 29 May 2024
Resolution: Received photograph of life float maintenance completed.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 31 August 2023 Resolved
To continue to participate in the AHE Program, vessel operators must conduct an annual hull condition assessment. At a minimum, vessel operators must conduct an internal examination and take random hull gaugings internally during the hull condition assessment, unless waived by the Officer in Charge, Marine Inspection (OCMI). The OCMI requires the annual hull assessment to attest to the depth of the identified areas of pitting to ensure the corrosion is arrested. The areas of pitting must be included in the required preventative maintenance reports to include permanent markings on the inside of the hull structure to accurately identify the location of the pits for future inspections and ultrasonic/non-destructive testing. 46CFR176.660(a)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2023
Resolved 24 September 2023
Resolution: Recieved revised repair proposal.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 July 2023 Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements of one of the standards listed below. (b) Steel hull vessels: ABS Steel Vessel Rules. The 2023 Alternate Hull Exam Underwater report revealed 02 areas of wastage in excess of allowance. Provide repair proposal to satisfaction of the Marine Inspector. 46 CFR 177.300(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2023
Resolved 24 March 2024
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 May 2023 Resolved
To continue to participate in the AHE Program, vessel operators must conduct an annual hull condition assessment. Marine Inspectors identified numerous areas of coating failure, and corrosion along the port and starboard pontoon keels. Repair and restore coating to continue participation in AHE Program prior to 2024 Annual Hull Assessment. 46 CFR 176.660(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2024
Resolved 15 June 2023
Resolution: Received photographs of hull coating reapplied.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 May 2023 Resolved
A vessel must comply with structural design requirements with listed standards: (b) ABS Steel Vessel Rules. Port hull aft transom penetrations no longer watertight. Restore integrity of watertight hull penetrations. 46CFR177.300
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2023
Resolved 30 May 2023
Resolution: Restored watertight integrity of hull penetrations. Provided proof of rectification via photograph.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 16 May 2023 Resolved
Each survival craft must be in good working condition and ready for immediate use. Replace life float oars, and repair life float pendant securing mechanism. 46CFR185.700(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2023
Resolved 30 May 2023
Resolution: Replaced oars and repaired pendants. Provided proof of rectification via photograph.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 16 May 2023 Resolved
No marine employer shall employ any individual to serve as a crewmember unless they pass a chemical test for that employer. Pre-employment test results not made available to Marine Inspector. 46CFR16.210(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2023
Resolved 30 May 2023
Resolution: Provided proof of pre-employment drug testing.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 May 2023 Resolved
If you use divers for Alternate Hull Exam, you must provide OCMI with written hull exam report. Provide report to OCMI. 46CFR176.655(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2023
Resolved 18 July 2023
Resolution: Received annual hull exam report.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 5 May 2022 Resolved
A complete application for an original proof that the applicant passed all applicable vision, hearing, or medical, and/or physical exams as required by subpart C is required by subpart C of this part or a valid medical certificate issued by the Coast Guard. The medical caertificate for the merchant mariner credential for the captain is not up to date. Captain may not operate commercially prior to updated medical certificate is provided. 46 CFR 10.225(b)(7)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2022
Resolved 24 May 2022
Resolution: Vessel operator sent photos of proof of satisfactory medical test.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 5 May 2022 Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. The cable runs from batteries to the engines in the two aft voids need to made watertight. 46 CFR 179.320
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2022
Resolved 1 June 2022
Resolution: Penetrations made weathertight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 May 2022 Resolved
A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. The bilge strainers in the vessel's two aft voids need to be made such that the suitable strainer has an open area 3x the area of the bilge pipe. 46 CFR 182.510(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2022
Resolved 1 June 2022
Resolution: Vessel replaced strainer with appropriate size.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 May 2022 Resolved
To continue to participate in the AHE program, vessel operators must conduct an annual hull condition assessment. Vessel needs to provide an annual hull gauging report for the continue enrollment in the AHE. 46 CFR 176.660(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2022
Resolved 1 June 2022
Resolution: Vessel submitted the hull gauging report from 2021.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 5 May 2022 Resolved
The breaking strength of each link for the life float must be between 900N and 1200N for links intended for life floats and buoyant apparatus of 11 to 20 persons capacity. The vessel did not have the appropriate weak link for one of their life floats. 46 CFR 160.073-10 (b)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2022
Resolved 9 June 2022
Resolution: Vessel sent in photo of the newly installed lifefloat weaklink.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 5 May 2022 Resolved
The lifeline and pendants must be furnished by the manufacturer with the approved life float or buoyant apparatus. The pendant line for the life float was severely chafed and needs to be replaced. 46 CFR 180.175(f)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2022
Resolved 1 June 2022
Resolution: Vessel operator submitted photos for replaced pendant line.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 5 May 2022 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking. The vessel's top deck needs to be marked with the maximum number of allowed passengers. 46 CFR 185.602(g)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2022
Resolved 24 May 2022
Resolution: Vessel operator sent photos proving upper passenger deck marked with maximum allowed passengers.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 17 June 2020 Resolved
Life float float-free link required by 46 CFR 180.130(a)(1) must be certified to meet 46 CFR 160.073 in subchapter Q of this chapter, or other standard specified by the Commandant. Stbd Life Float float-free link not an approved type.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 17 June 2020
Resolved 17 June 2020
Resolution: Installed an approved float-free link in the presence of the attending MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 June 2020 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery. Stbd pump has a cracked housing temporarily patched with JB Weld and leaking while operating. Replace housing.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2020
Resolved 25 August 2020
Resolution: Owner provided satisfactory evidence parts were replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 June 2020 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery. The port pump mechanical seal and housing gasket were leaking excessively during operation. Repair mechanical seal and replace required gaskets.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2020
Resolved 25 August 2020
Resolution: Owner provided satisfactory evidence parts were replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 June 2020 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of piping systems. The bilge manifold port #4 void valve cracked and repaired with Syntho-Glass.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2020
Resolved 3 July 2020
Resolution: Provided a photograph of newly installed valve.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 June 2020 Resolved
At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached. Each lifeline on a ring life buoy must: Be of at least 18.3 meters (60 feet) in length. Vessel's life ring buoy lifeline less than 60 feet. Replace.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2020
Resolved 25 August 2020
Resolution: Owner provided evidence new throw line was placed into service.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 17 June 2020 Resolved
As per 46 CFR 160.027-2, each life float must have Type II retro-reflective material meeting subpart 46 CFR 160.018 on each side and end. Life float retro-reflective tape wasted an requires renewal.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 June 2020
Resolved 17 June 2020
Resolution: Renewed retroreflective tape
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 June 2020 Resolved
Batteries - general: Connections must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps are prohibited. Battery connection to terminals made with wingnuts, which are not a permanent type connector. Replace with nuts.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2020
Resolved 7 July 2020
Resolution: Provided photograph of nuts installed on battery terminals.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 17 June 2020 Resolved
Charts and nautical publications - as appropriate for the intended voyage, a vessel must carry adequate and up-to-date. Coast Pilot and Light List missing.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 17 June 2020
Resolved 17 June 2020
Resolution: Provided current extracts of the Coast Pilot and Light List for Lake Tahoe
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 June 2020 Resolved
An EAP training program must be conducted for the employer's crew members and supervisory personnel. Missing documentation of training given to crew members and the employer's supervisory personnel. Provide proof of training.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2020
Resolved 25 August 2020
Resolution: Owner provided proof of EAP training conducted.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 24 July 2019 Resolved
The owner or managing operator shall make sure that maintenance is carried out in accordance with manufacturer's instructions. The 02 life floats are beginning to show signs of deterioration. Conduct monthly maintenance IAW manufacturer's instructions. 46 CFR 185.702(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 August 2019
Resolved 3 September 2019
Resolution: Received photograph of maintenance conducted on life floats.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 24 July 2019 Resolved
Each item of lifesaving equipment with an expiration date must be replaced during the annual inspection if the expiration date has passed. The batteries in 02 water lights are expired. Replace IAW manufactuer's instructions. Restricted to daylight operations until rectified. 46 CFR 185.726(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 August 2019
Resolved 8 August 2019
Resolution: Battery replaced with expiration date of 01/2025.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 July 2019 Resolved
A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. The bilge strainer does not have an open area of three times the area of the bilge pipe. Replace strainer to meet the requirements of 46 CFR 182.510. 46CFR182.510(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 August 2019
Resolved 8 August 2019
Resolution: Bilge strainer installed to the satisfaction of the MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 July 2019 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at a constant marine load under such requirements without exceeding its designed limitations. The No. 3 outboard motor is currently inoperable. The vessel does not usually operate with this motor under normal conditions. Provide proof of repair to the satisfaction of the Marine Inspector. 46 CFR 182.310
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 August 2019
Resolved 14 August 2019
Resolution: The engine was repaired to the satisfaction of the MI.
Lifesaving › Lifebuoys › Serviceable
Issued 21 May 2018 Resolved
Renew ring buoys with deteriorated lines IAW Qspec 160.050.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2018
Resolved 29 May 2018
Resolution: Proof of purchase provided.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure
Issued 21 May 2018 Resolved
Remove/replace partially discharged fire extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 May 2018
Resolved 21 May 2018
Engineering › Bilge Water Management System › Strainer
Issued 21 May 2018 Resolved
Replace broken bilge suction strainer in the #2 stbd void.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 June 2018
Resolved 29 May 2018
Resolution: Invoice for required part recieved.
Engineering › Fuel Oil Service System › Valve
Issued 9 August 2017 Resolved
Label fuel shufoff valve with 1 inch lettering and indicate direction of operation. 46 CFR 180.608
Due 8 September 2017
Resolved 28 August 2017
Resolution: Observed labeled valve.
Lifesaving › Hand Flares › Quantity
Issued 9 August 2017 Resolved
Provide 2 additional flares for a total of 6. 46 CFR 180.68b
Due 8 September 2017
Resolved 9 August 2017
Lifesaving › Lifefloat › Float Free
Issued 9 August 2017 Resolved
Make life floats float free by loosening yellow line. 46 CFR 180.130a2
Due 8 September 2017
Resolved 9 August 2017
Lifesaving › Liferaft Equipment › Paddle
Issued 17 July 2012 Resolved
Replace broken paddle on life float.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 August 2012
Resolved 13 August 2012
Resolution: New paddle provided
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 17 July 2012 Resolved
Properly secure overboard discharge valve for sewage.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 August 2012
Resolved 13 August 2012
Resolution: Valve properly secured
Documentation › Markings/Placards › Warning Signs
Issued 17 July 2012 Resolved
Provide Sewage discharge placard located at the sewage pumping station.
Action required: 705 - Other - as specified
Due 1 August 2012
Resolved 13 August 2012
Resolution: Provided
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 17 July 2012 Resolved
Provide a suitable anchor and ground tackle of adequate size onboard the vessel.
Action required: 705 - Other - as specified
Due 1 August 2012
Resolved 13 August 2012
Resolution: Provided
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 15 August 2011 Resolved
Identified 1 B-II portable extinguisher on the vessel which had been missed during the yearly servicing. Portable was in excess of the requirement and was removed from the vessel on the spot.
Action required: 705 - Other - as specified
Due 15 August 2011
Resolved 15 August 2011
Engineering › Bilge Water Management System › Valve
Issued 15 August 2011 Resolved
Found inop check valve from viod #3 stbd. Operator performed necessary maintainence and it was corrected on the spot.
Action required: 705 - Other - as specified
Due 15 August 2011
Resolved 15 August 2011
Operations/Management › Drills/Instruction › Not Conducted
Issued 5 May 2009 Resolved
Conduct underway drills, steering and propulsion tests.
Action required: 705 - Other - as specified
Due 5 June 2009
Resolved 28 May 2009
Lifesaving › Lifefloat › Float Free
Issued 18 June 2007 Resolved
Properly install forward lifefloat in a float-free arrangement. Vessel is restricted to no more than 30 persons onboard.
Due 18 July 2007
Resolved 14 May 2008
Lifesaving › Lifefloat › Quantity
Issued 8 May 2006 Resolved
Provide 50% lifefloats on board. Vessel is restricted to 30 total persons onboard until corrected. IAW 46 CFR 180.207 vessel must maintain a 15 minute communication with an operations base when carrying more than 30 persons.
Due 8 June 2006
Resolved 18 June 2007
Electrical › Electrical Distribution System (service) › Cable
Issued 8 May 2006 Resolved
Submit plans for approval to the local OCMI for the replacement of the outboard engine starting battery cable with approved UL marine grade battery cable IAW 46 CFR 183.340.
Due 8 June 2006
Resolved 24 July 2006
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 8 May 2006 Resolved
Replace waterlight batteries with approved screw terminal batteries IAW 46 CFR 183.350(d).
Due 8 June 2006
Resolved 8 May 2006
Construction/Loadline › Hull › Hull Plating
Issued 26 July 2005 Resolved
Provide annual survey IAW. 176.660 AHE Program.
Action required: 705 - Other - as specified
Due 26 September 2005
Resolved 9 May 2006
Lifesaving › Visual Distress Signals (General)
Issued 10 May 2004 Resolved
Renew 3 day smoke signals.
Due 14 May 2004
Resolved 14 May 2004
Resolution: Renewed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 10 May 2004 Resolved
Renew all waterlight batteries on annual basis.
Due 14 May 2004
Resolved 14 May 2004
Resolution: Renewed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 May 2004 Resolved
Renew first aid kit.
Due 14 May 2004
Resolved 14 May 2004
Resolution: Renewed.
Documentation › Markings/Placards
Issued 10 May 2004 Resolved
Post station bill.
Due 14 May 2004
Resolved 14 May 2004
Resolution: Posted.
Lifesaving
Issued 10 May 2004 Resolved
Secure and put vessel name on the two oars for the lifefloat.
Due 14 May 2004
Resolved 14 May 2004
Resolution: Oars secured, name of vessel stenciled on oars.
Electrical
Issued 10 May 2004 Resolved
Provided proper electrical connections for the wiring of the public announcement speakers.
Due 14 May 2004
Resolved 14 May 2004
Resolution: Proper connections installed.
Engineering › Bilge Water Management System
Issued 20 May 2003 Resolved
Install bilge strainers for port 6 and 7 voids, and starboard 4 void. LEGACY COMPONENT DESC: Strainer
Action required: 705 - Other - as specified
Due 21 June 2003
Resolved 21 May 2003
Lifesaving › Lifebuoys
Issued 20 May 2003 Resolved
Provide retro-reflective material for (4) additional life rings per 46 CFR 180.70. LEGACY COMPONENT DESC: Retro-reflective material
Action required: 705 - Other - as specified
Due 21 June 2003
Resolved 21 May 2003
Documentation › Certificates/Documents › Certificate of Inspection
Issued 20 May 2003 Resolved
Post COI and Stability Letter in a visible location.
Due 21 June 2003
Resolved 20 May 2003
Resolution: Posted COI and Stability Letter.
Documentation › Manifests/Lists
Issued 20 May 2003 Resolved
Provide list of senior deckhands. LEGACY COMPONENT DESC: Senior Deckhand
Due 21 June 2003
Resolved 20 May 2003
Resolution: Provided list.
Engineering
Issued 6 August 2002 Resolved
Remove throttle cables from rear control station prior to sailing.
Due 6 August 2002
Resolved 7 August 2002
Resolution: Throttle cables were removed from rear control station.
Engineering
Issued 6 August 2002 Resolved
Install throttle cables for forward control station prior to sailing.
Due 6 August 2002
Resolved 7 August 2002
Resolution: Throttle cables installed at fwd control station.
Operations/Management
Issued 6 August 2002 Resolved
Submit following modifications to MSO SF Bay for plan review NLT 20Aug2002: a- Food Service area, b- Portable head area, c-Upper deck vertical railing, d- Aft control station.
Due 20 August 2002
Resolved 12 September 2003
Lifesaving › Lifebuoys
Issued 16 April 2002 Resolved
Replace/Renew missing retro tape
Due 16 April 2002
Resolved 16 April 2002
Resolution: Retro tape added to two lifebuoys
Lifesaving › Lifejacket/PFD (Type I)
Issued 16 April 2002 Resolved
Replace/Renew two ripped lifejackets. LEGACY COMPONENT DESC: Condition
Due 16 April 2002
Resolved 16 April 2002
Resolution: Life jackets were removed from service.
Construction/Loadline › Hull
Issued 29 November 2001 Resolved
REPAIR AS NEW, FLIGHT DECK STANCHIONS ON THE PORT SIDE FWD IN WAY OF WATER FREEZE DAMAGE. LEGACY COMPONENT DESC: Stanchions
Condition: Unknown
Due 30 May 2002
Resolved 6 August 2002
Resolution: The lower 3 ft of the flight deck support stanchion was cropped out and renewed.
Stability › Watertight Integrity
Issued 29 November 2001 Resolved
MAKE THE MAIN DECK WATERTIGHT IN WAY OF AFT DECK SOFTPATCH. LEGACY COMPONENT DESC: Softpatch
Condition: Unknown
Due 30 May 2002
Resolved 6 August 2002
Resolution: Both Port and Stbd soft patch hatches have watertight gaskets installed and are securely fastened with machine screws.
Fire Fighting
Issued 16 November 1998 Resolved
SERVICE B-II FIRE EXTINGUISHER ON PORT SIDE OF OPERATING STATION.
Condition: Unknown
Due 16 November 1998
Resolved 16 November 1998
Fire Fighting
Issued 16 November 1998 Resolved
SUBMIT PROPOSAL FOR SELF-PRIMING ARRANGEMENT FOR FIRE AND BILGE PUMPS.
Condition: Unknown
Due 16 November 1998
Resolved 16 November 1998

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.