MAURY USCG vessel records Sign in
← All vessels

LANA'I

LANA'I is a 1996 passenger vessel (inspected). The Coast Guard has recorded 73 inspections since 1996, most recently in January 2026, along with 76 deficiencies and 4 casualty investigations between 2001 and 2016.

Records from 1996 to 2026. Most recent: inspection, 12 January 2026.

Built
1996
Last inspected
12 January 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ4593
440498
Flag
UNITED STATES
367762170, 367779180
Maury page id
psix-440498

Inspections, by type

…with no type recorded6
Years with a record 27 calendar years (1996–2026)
The 73 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)49.8 ft × 28.5 ft × 5.0 ft
Registered tonnagegross 23 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMOLTIS BY MILLETT · LAWAI KAUAI HI, UNITED STATES · built 1996
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationTwin Hull
Hailing portLANAI, HI
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 13 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it23 - Simplified, Gross Ton
18 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ4593MMSI 367779180 · active · compulsorily equipped · granted 25 March 2017, expires 25 March 2027
WDJ2834MMSI 367762170 · active · compulsorily equipped · granted 15 November 2016, expires 15 November 2026
WCW9252MMSI 367142180 · expired · compulsorily equipped · granted 27 September 2006, cancelled 31 December 2016
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 73

12 January 2026 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8295350
27 May 2025 Drydock Exam · Examination of Repairs
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8145707
17 September 2024 Deficiency Check · Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8001756
28 September 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7800136
23 May 2023 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7694821
11 October 2022 Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7574770
18 January 2022 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7386900
13 October 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7331972
14 May 2021 Internal Structural Exam · Drydock Exam · Deadweight Survey · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7197305
8 April 2021 Deficiency Check · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7172243
24 November 2020 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7101090
24 July 2020 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7018386
22 November 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6860435
1 November 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6847308
30 October 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6846607
14 June 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6718540
5 June 2019 Examination of Repairs · Drydock Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6707107
23 October 2018 Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6567724
11 October 2017 COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6285630
5 June 2017 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6221931
3 March 2017 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6098700
1 November 2016 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6046875
9 September 2016 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6004797
27 June 2016 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5924076
17 September 2015 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5728212
25 August 2014 Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4965592
20 May 2014 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4863834
25 October 2010 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3877285
5 November 2008 DAPI Audit
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3358045
22 October 2008 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3349158
27 August 2008 Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3310474
22 July 2008 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3276291
18 December 2007 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3117853
24 October 2007 COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3086295
19 October 2006 Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2843847
4 October 2006 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2792822
8 June 2006 Drydock Extension
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2674085
14 February 2006 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2585140
9 November 2005 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2531274
10 November 2004 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2255373
9 September 2004 Hull Examination · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2276819
23 February 2004 Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2011903
14 November 2003 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1947852
3 November 2003 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1943496
8 April 2003 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1770593
26 November 2002 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1711381
12 November 2002 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1699595
11 September 2002 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1770541
16 July 2002 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1665185
8 February 2002 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1484305
14 October 2001 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 6778
10 September 2001 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 772457
29 September 2000 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1417137
19 January 2000 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 814056
10 December 1999 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 811761
19 November 1999 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 813411
15 November 1999 COI Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1365441
29 October 1999 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1131935
23 July 1999 Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1402915
22 July 1999 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 108052
13 January 1999 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 810275
18 November 1998 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1434813
2 September 1998 MARPOL Annex V Examination · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1388610
7 July 1998 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 213379
3 June 1998 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 150935
2 December 1997 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1364501
26 June 1997 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 779950
16 June 1997 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1111067
16 April 1997 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1105574
13 February 1997 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1107432
4 December 1996 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 876481
27 November 1996 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1442489
4 November 1996 Hull Examination · Plan Review "T" Boat
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1390383

Deficiency record · 76

11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 12 January 2026 Resolved
Portable watertight containers for distress flares and smoke signals shall be of a bright color and clearly marked; Hand red flare distress signals are not stored in portable watertight container. 46 CFR 185.614
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 February 2026
Resolution: Corrected.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 January 2026 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules; Starboard side light is extinguished. Restricted to daytime ops. 46 CFR 183.420
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 February 2026
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 12 January 2026 Resolved
Emergency instructions must be mounted at operating station containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions; placard is faded and not posted at operating station. 46 CFR 185.510(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 February 2026
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 September 2024 Resolved
All fiber reinforced plastic vessels constructed with general purpose resins must be fitted with a smoke activated fire detection system of an approved type installed in accordance with 76.27 in subchapter H of this chapter in accommodation spaces and service spaces. Vessel does not a have smoke activated fire detection system for required spaces. Provide smoke activated fire detection system and install to the satisfaction of the attending marine inspector. Vessel operator intends to submit special consideration for interconnected fire detection and alarm system. 46 CFR 177.410(c)(3)(ii)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2024
Resolved 22 November 2024
Resolution: Special Consideration approved. Document attached.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 September 2024 Resolved
The owner shall be prepared to conduct tests and have the vessel ready for inspection of the following: On a sailing vessel all spars, standing rigging, running rigging, blocks, fittings, and sails. Vessel does not have a current up-to-date sail rigging equipment and components Preventative Maintenance plan (PMP) in accordance with USCG NVIC 02-16. Requires 2024 updates. 46 CFR 176.802 (a)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2024
Resolved 23 September 2024
Resolution: Received updated PMP for Year 2024
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 28 September 2023 Resolved
Vessel is required to ensure the EPIRB's battery is replaced after it is used, or before the date required by FCC regulations in 47 CFR part 80, whichever comes sooner. Vessel's EPIRB battery was past its expiration date. Replace battery to satisfaction of attending Coast Guard Marine Inspector. Vessel restricted to within three mile of shore. 46 CFR 185.728
Action required: 705 - Other - as specified
Resolved 3 October 2023
Resolution: New EPIRB provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 September 2023 Resolved
A complete application for an original MMC must contain proof, documented on CG-719-K or CG-719-K/E, as appropriate, that the applicant passed all applicable vision, hearing, medical, and/or physical exams as required by subpart C of this part or a valid medical certificate issued by the Coast Guard. The Master did not have his medical certificate available. Provide master with valid MMC and Medical Certificate. 46 CFR 10.302(a)
Action required: 705 - Other - as specified
Resolved 17 November 2023
Resolution: Medical cert provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 September 2023 Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. Operating station portable fire extinguisher was in the discharge/red zone on the gauge. Provide extinguisher that is not in the discharge zone. 46 CFR 176.810
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 October 2023
Resolution: New portable extinguisher provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 October 2022 Resolved
Vessel must have permanent loading marks placed on each side of the vessel forward and aft to indicate the maximum allowable trim and amidships to indicate the maximum allowable draft. A loading mark must be a horizontal line of at least 8 inches in length and 1 inch in height, with its upper edge passing through the point of maximum draft. The loading mark must be painted in a contrasting color to the sideshell paint. Loading marks not on vessel. Provide loading marks in accordance with your stability letter and communicate with MSC to ensure exact location. Stability letter may need updated to provide these marks. 46 CFR 185.602
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 November 2022
Resolved 20 November 2022
Resolution: Markings provided.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 11 October 2022 Resolved
The name of the vessel must be marked in clearly legible letters and numbers on each side of the life float. The number of persons capacity must be marked on each life float. Name of vessel not on both sides of float and number of passengers not on life float. Provide name and number on life float. 46 CFR 185.604
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 November 2022
Resolved 20 November 2022
Resolution: Name and number of passengers provided on life float.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 October 2022 Resolved
On a vessel of at least 26 ft, a visual and audible alarm must be provided at the operating station to indicate high water level in machinery space. Port engine room bilge high level visual indicator not operational. Provide bilge high level visual indicator. 46 CFR 182.530
Action required: 17 - Rectify deficiencies prior to departure
Due 11 October 2022
Resolved 12 October 2022
Resolution: Bilge visual indicator operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 October 2021 Resolved
The number of lifejackets must be marked in clearly legible 2 inch marking on container. Lifejacket number marking missing on forward containers. Provide proper marking. 46 CFR 185.604
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2021
Resolved 11 November 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 October 2021 Resolved
Remote fuel shutoff station must be marked in clearly legible 1 inch letters indicating purpose of the valve and direction of operation. Remote fuel shutoff marking missing. Provide proper marking. 46 CFR 185.608
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2021
Resolved 11 November 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 October 2021 Resolved
The design of standing rigging must be suitable for the intended service. Cracks showing on crossbeam on both port and starboard sides where chain plates connects. Provide repair proposal of cracked crossbeam and make repairs. 46 CFR 177.330 19 Nov 2021 - Beam found to be rotted. Vessel prohibited from raising sails or transiting under sail. Provide repair proposal and timeline.
Action required: 705 - Other - as specified
Due 13 November 2021
Resolved 31 May 2023
Resolution: Repairs completed per approved structural modification. See MSC letter H1-2300021.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 13 October 2021 Resolved
The construction of vessel must allow for safe operation to protect against damage. 02 soft spots on deck located in passenger accommodation area. Provide repair proposal and make repairs to soft deck. 46 CFR 177.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2021
Resolved 10 December 2021
Resolution: Proposal submitted. Temp repair in place until perm repair conducted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 October 2021 Resolved
Sail Rigging Preventative Maintenance Plan (PMP) not updated with all current configurations. In PMP provide sail plan, full rigging inventory, and inspection regime. Ensure all to log all inspections in accordance with vessel PMP. Keep copy of PMP on board vessel at all times and submitted revised version of PMP to [name withheld] 02-16
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2021
Resolved 17 December 2021
Resolution: PMP Provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 April 2021 Resolved
An EAP training program must be conducted for the employer's crewmembers and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crewmembers and Supervisory personnel must receive at least 60 minutes of training. Provide proof of completed EAP training for all personnel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2021
Resolved 6 May 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 November 2020 Resolved
Sail Rigging Preventative Maintenance Plan (PMP) not being utilized as designed. Daily, weekly, monthly, and semi-annual inspections not being conducted and/or logged as plan states in the past year. Provide full rigging inventory of all old and new rigging components. Begin to log all inspections in accordance with vessel PMP.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2020
Resolved 22 March 2021
Resolution: PMP provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 November 2020 Resolved
Bilge high water alarm visual indicator at helm showing same light for both compartments. A second light is mounted and supposed to operate separately for each space. Ensure system is set up as designed and as approved drawings indicate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2020
Resolved 8 February 2021
Resolution: System is now set up as designed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 25 November 2020 Resolved
Port lights missing hinged dead covers. Provide hinged dead covers for port lights.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2020
Resolved 19 May 2021
Resolution: Replaced hinged dead cover on port lights.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 25 November 2020 Resolved
Forward storage compartment starboard side has rotting frame. Remove rotted frame and make repairs to good wood.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2020
Resolved 19 May 2021
Resolution: Removed and replaced deck scantling in the fwd inboard hatch on the starboard side.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 November 2020 Resolved
Bolt on starboard forward chain plate holding crossbeam showing severe corrosion and not bedded down. Replace with new bolt.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2020
Resolved 19 May 2021
Resolution: The bolt was replaced on the fwd starboard chain plate.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 November 2020 Resolved
Clevis pin on aft port on running rigging at deck worn. Replace clevis pin.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2020
Resolved 8 February 2021
Resolution: New clevis pin installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 November 2020 Resolved
02 main sail cars disconnected from mast. Make all cars on main sail run the mast as designed. Complete at next drydock.
Action required: 705 - Other - as specified
Due 24 December 2020
Resolved 19 May 2021
Resolution: The track was replaced on the mast.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 November 2020 Resolved
During inspection foresail/jib not installed/onboard. New sail being provided. Provide dimensions of new sail and show that new sail conforms with approved sail plan. Provide video of vessel under sail with new sail.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2020
Resolved 8 February 2021
Resolution: Foresail/jib installed.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 30 October 2019 Resolved
Port engine compartment bilge alarm was inoperative. Repair in accordance with 46 CFR 176.804.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 November 2019
Resolution: Bilge alarm satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 October 2019 Resolved
Port and stbd engine compartment Fireboy audible alarms were inoperative. Reapair in accordance with 46 CFR 176.810.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 November 2019
Resolution: Audible alarms satisfactory.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 30 October 2019 Resolved
DSC VHF radio was not provided. Provide in accordance with 46 CFR 184.502.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2019
Resolved 21 November 2019
Resolution: DSC VHF radio provided.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 30 October 2019 Resolved
6 port light dead covers were not provided. Provide covers in accordance with 46 CFR 176.802.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2019
Resolved 21 November 2019
Resolution: 6 deadlight covers provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 October 2019 Resolved
Wiring and associated terminal strip were not secured under mast step. Secure in accordance with 46 CFR 176.806.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2019
Resolved 21 November 2019
Resolution: Wiring and terminal strip under mast secured.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 October 2019 Resolved
Holes were present in port engine room forward watertight bulkhead. Seal bulkhead in accordance with 46 CFR 176.802.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2019
Resolved 21 November 2019
Resolution: Holes in port engine room watertight bulkheads were sealed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 October 2019 Resolved
Rigging Preventative Maintenance Plan was not provided. Provide in accordacne with 46 CFR 176.840.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2019
Resolved 21 November 2019
Resolution: Rigging Preventative Maintenance Plan was provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 October 2019 Resolved
Current Radio Safety Certificate was not provided. Provide in accordance with 46 CFR 184.502.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2019
Resolved 21 November 2019
Resolution: Radio Safety Certificate provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 October 2019 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2019
Resolved 21 November 2019
Resolution: FCC Station License provided.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 30 October 2019 Resolved
Proof of monthly EPIRB tests were not provided. Provide log in accordance with 46 CFR 185.728.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2019
Resolved 21 November 2019
Resolution: Monthly e-pirb test provided.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 30 October 2019 Resolved
2019 Coast Pilot [name withheld] and Tide Tables were not provided. Provide in accordance with 46 CFR 184.420.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2019
Resolved 21 November 2019
Resolution: Current Light List, Coast Pilot and Tide Tables provided.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 June 2019 Resolved
Provide Marine Inspector visual inspection of aluminum mast step in-kind to original design verified by the approved drawing prior to installation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 June 2019
Resolution: New in-kind mast step base plate provided for inspection.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 5 June 2019 Resolved
Following approval of mast step configuration and re-installation of mast, sea trials are to be conducted under sail propulsion by an attending Marine Inspector prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 June 2019
Resolution: Sea trial under sail conducted.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 11 October 2017 Resolved
Missing updated Radio Safety Certificate.
Condition: Invalid
Due 21 October 2017
Resolved 25 October 2017
Resolution: Provided.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 11 October 2017 Resolved
Extingushers and Installed system due for annual service.
Condition: Invalid
Due 1 November 2017
Resolved 26 October 2017
Resolution: Service completed.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 11 October 2017 Resolved
Provide rigging preventative maintenance plan.
Condition: Invalid
Due 11 November 2017
Resolved 13 November 2017
Resolution: Plan provided by surveyor [name withheld]
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 11 October 2017 Resolved
Missing one adult pfd. Limited to 50 persons total.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 17 October 2017
Resolution: PFD provided.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 25 October 2010 Resolved
Renew exhaust hose on port engine IWO turbocharger to elbow.
Action required: 705 - Other - as specified
Due 1 November 2010
Resolved 1 November 2010
Construction/Loadline › Structures › Trunk
Issued 25 October 2010 Resolved
Make repairs to fracture IWO dagger board trunk inboard side.
Action required: 705 - Other - as specified
Due 1 November 2010
Resolved 1 November 2010
Electrical › Electric Supply System (service)
Issued 3 November 2003 Resolved
Provide missing battery box covers for port and starboard enginerooms. LEGACY COMPONENT DESC: Battery Installation
Condition: Improper/Lack of Maintenance
Due 17 November 2003
Resolved 14 November 2003
Lifesaving › Buoyant Apparatus
Issued 3 November 2003 Resolved
Provide weak link for #2 lifefloat. LEGACY COMPONENT DESC: weak link
Condition: Improper/Lack of Maintenance
Due 3 November 2003
Resolved 3 November 2003
Lifesaving › Buoyant Apparatus
Issued 3 November 2003 Resolved
Provide water light for #1 life float. LEGACY COMPONENT DESC: water light
Condition: Improper/Lack of Maintenance
Due 3 November 2003
Resolved 3 November 2003
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 3 November 2003 Resolved
Replace lifeline for lifebuoy.
Condition: Improper/Lack of Maintenance
Due 3 November 2003
Resolved 3 November 2003
Electrical › Electrical Distribution System (service)
Issued 12 November 2002 Resolved
Provide metal supports for wiring located in port and starboard engine rooms IAW 46CFR183.340(b)(4). LEGACY COMPONENT DESC: Wiring
Condition: Unknown
Due 26 November 2002
Resolved 26 November 2002
Electrical › Electrical Distribution System (service)
Issued 12 November 2002 Resolved
Remove or properly repair dead end wires located at operating station IAW 46CFR183.340. LEGACY COMPONENT DESC: Wiring
Condition: Unknown
Due 26 November 2002
Resolved 26 November 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 12 November 2002 Resolved
Install bulwarks, wire mesh, chain link fencing, etc. to meet the requirements of 46CFR177.900(g)(1). LEGACY COMPONENT DESC: Deck Rail
Condition: Unknown
Due 12 December 2002
Resolved 8 April 2003
Communications › Radio Communications
Issued 12 November 2002 Resolved
Properly install EPIRB IAW 46CFR180.64. LEGACY COMPONENT DESC: EPIRB
Condition: Unknown
Due 26 November 2002
Resolved 13 November 2002
Communications › Radio Communications
Issued 12 November 2002 Resolved
Properly register EPIRB IAW 46CFR184.502. Provide evidence of registration to USCG prior to passenger operations. LEGACY COMPONENT DESC: EPIRB
Condition: Unknown
Due 12 November 2002
Resolved 13 November 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 12 November 2002 Resolved
Provide 30 CG approved adult lifejackets IAW 46CFR180.71. Vessel is restricted to carrying 20 adult passengers. LEGACY COMPONENT DESC: Condition
Condition: Unknown
Due 26 November 2002
Resolved 26 November 2002
Lifesaving › Buoyant Apparatus
Issued 12 November 2002 Resolved
Properly repair platform ring for port life float IAW 46CFR180.200. LEGACY COMPONENT DESC: Platform ring
Condition: Unknown
Due 26 November 2002
Resolved 26 November 2002
Construction/Loadline › Structures
Issued 12 November 2002 Resolved
Properly repair hatch located in port head IAW 46CFR179.360. LEGACY COMPONENT DESC: Door
Condition: Unknown
Due 26 November 2002
Resolved 26 November 2002
Construction/Loadline › Structures
Issued 12 November 2002 Resolved
Properly repair fractured welds on hatch covers (4) for port and starboard engine rooms and port and starboard fwd compartments IAW 46CFR179.360. LEGACY COMPONENT DESC: Manhole
Condition: Unknown
Due 26 November 2002
Resolved 26 November 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 8 February 2002 Resolved
Rejected 12 adult lifejackets and 2 child lifejackets.
Condition: Unknown
Due 8 February 2002
Resolved 8 February 2002
Construction/Loadline
Issued 15 November 1999 Resolved
Provide bilge high level and bilge pump alarms as required by 46 CFR 182.530 NLT 15DEC99.
Condition: Unknown
Due 15 December 1999
Resolved 10 December 1999
Lifesaving
Issued 15 November 1999 Resolved
Provide a FCC type accepted category 1, 406 EPIRB, installed to automatically float free and activate IAW 46 CFR 180.64 NLT 15DEC99._x001C_ Vessel is restricted to NMT 3 miles from shore until in compliance.
Condition: Unknown
Due 19 November 1999
Resolved 19 November 1999
Construction/Loadline
Issued 23 July 1999 Resolved
Replace vessel mast, ensure new mast is installed to the satisfaction of a USCG marine inspector.
Condition: Unknown
Due 23 July 1999
Resolved 23 July 1999
Engineering
Issued 27 November 1996 Resolved
Install exhaust lagging on the turbocharger exhaust elbows of the port and stbd main diesel engines.
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Construction/Loadline
Issued 27 November 1996 Resolved
Provide a watertight dead cover for each port light.
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Electrical
Issued 27 November 1996 Resolved
Install, at the port 12 volt battery, an electrical isolation switch to separate the port and stbd 12 volt batteries.
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Fire Fighting
Issued 27 November 1996 Resolved
Permanently repair the system indicator light for the port FE-241 system located at the steering station.
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Construction/Loadline
Issued 27 November 1996 Resolved
Make the openings in the aft bulkhead of the port and stbd engine rooms vapor tight.
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Construction/Loadline
Issued 27 November 1996 Resolved
Install handles and make the Bomar hatches located in the aft bulkhead of the port and stbd engine rooms operable from the engine rooms.
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Documentation
Issued 27 November 1996 Resolved
Obtain and post emergency instructions and waste management plan. Provide onboard a garbage log.
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Documentation
Issued 27 November 1996 Resolved
Obtain a valid FCC Radio Safety Certificate Form 824.
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Documentation
Issued 27 November 1996 Resolved
Obtain and post the vessel's stability letter and provide onboard the vessel's Coast Guard approved sail plan.
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Fire Fighting
Issued 27 November 1996 Resolved
Install and prove operation of the FE-241 automatic engine shutdown for theport and stbd main diesel engines.
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Documentation
Issued 27 November 1996 Resolved
Provide proof of the Employees Assistance Program and Supervisory Drug and Alcohol training in accordance with 46 CFR 16.
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Navigation
Issued 27 November 1996 Resolved
Provide charts of the vessel's operating area, COLREGS 72 Navigation publication, 8" bell and a suitable sound producing device (air horn).
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Construction/Loadline
Issued 27 November 1996 Resolved
Provide suitable suction and discharge hoses and suction strainer for the portable hand bilge/fire pump.
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Lifesaving
Issued 27 November 1996 Resolved
Provide a waterlight and 18 foot lanyard for the port lifefloat.
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Lifesaving
Issued 27 November 1996 Resolved
Provide a waterlight and 18 foot lanyard for the bow lifefloat.
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996

Casualty record · 4

14 October 2001Routine · role: Involved in a Marine Casualty · activity 6778
16 July 2002Routine · role: Involved in a Marine Casualty · 1 injured · activity 1665185
29 January 2013Routine · role: Involved in a Marine Casualty · activity 4532343
27 June 2016Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 5924076
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

TRILOGY IV (2001–2016). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.