Records from 2001 to 2026. Most recent: inspection, 12 January 2026.
Inspection history · 24
12 January 2026
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8295350
27 May 2025
Drydock Exam · Examination of Repairs
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8145707
17 September 2024
Deficiency Check · Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8001756
28 September 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7800136
23 May 2023
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7694821
11 October 2022
Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7574770
18 January 2022
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7386900
13 October 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7331972
14 May 2021
Internal Structural Exam · Drydock Exam · Deadweight Survey · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7197305
8 April 2021
Deficiency Check · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7172243
24 November 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7101090
24 July 2020
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7018386
22 November 2019
Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6860435
1 November 2019
Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6847308
30 October 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6846607
14 June 2019
Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6718540
5 June 2019
Examination of Repairs · Drydock Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6707107
23 October 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6567724
11 October 2017
COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6285630
5 June 2017
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6221931
3 March 2017
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6098700
1 November 2016
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6046875
9 September 2016
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6004797
27 June 2016
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5924076
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 12 January 2026
Resolved
Portable watertight containers for distress flares and smoke signals shall be of a bright color and clearly marked; Hand red flare distress signals are not stored in portable watertight container.
46 CFR 185.614
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 February 2026
Resolution: Corrected.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 January 2026
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules; Starboard side light is extinguished. Restricted to daytime ops.
46 CFR 183.420
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 February 2026
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 12 January 2026
Resolved
Emergency instructions must be mounted at operating station containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions; placard is faded and not posted at operating station.
46 CFR 185.510(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 February 2026
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 September 2024
Resolved
All fiber reinforced plastic vessels constructed with general purpose resins must be fitted with a smoke activated fire detection system of an approved type installed in accordance with 76.27 in subchapter H of this chapter in accommodation spaces and service spaces. Vessel does not a have smoke activated fire detection system for required spaces. Provide smoke activated fire detection system and install to the satisfaction of the attending marine inspector. Vessel operator intends to submit special consideration for interconnected fire detection and alarm system. 46 CFR 177.410(c)(3)(ii)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2024
Resolved 22 November 2024
Resolution: Special Consideration approved. Document attached.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 September 2024
Resolved
The owner shall be prepared to conduct tests and have the vessel ready for inspection of the following: On a sailing vessel all spars, standing rigging, running rigging, blocks, fittings, and sails. Vessel does not have a current up-to-date sail rigging equipment and components Preventative Maintenance plan (PMP) in accordance with USCG NVIC 02-16. Requires 2024 updates. 46 CFR 176.802 (a)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2024
Resolved 23 September 2024
Resolution: Received updated PMP for Year 2024
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 28 September 2023
Resolved
Vessel is required to ensure the EPIRB's battery is replaced after it is used, or before the date required by FCC regulations in 47 CFR part 80, whichever comes sooner. Vessel's EPIRB battery was past its expiration date. Replace battery to satisfaction of attending Coast Guard Marine Inspector. Vessel restricted to within three mile of shore.
46 CFR 185.728
Action required: 705 - Other - as specified
Resolved 3 October 2023
Resolution: New EPIRB provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 September 2023
Resolved
A complete application for an original MMC must contain proof, documented on CG-719-K or CG-719-K/E, as appropriate, that the applicant passed all applicable vision, hearing, medical, and/or physical exams as required by subpart C of this part or a valid medical certificate issued by the Coast Guard. The Master did not have his medical certificate available. Provide master with valid MMC and Medical Certificate.
46 CFR 10.302(a)
Action required: 705 - Other - as specified
Resolved 17 November 2023
Resolution: Medical cert provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 September 2023
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. Operating station portable fire extinguisher was in the discharge/red zone on the gauge. Provide extinguisher that is not in the discharge zone.
46 CFR 176.810
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 October 2023
Resolution: New portable extinguisher provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 October 2022
Resolved
Vessel must have permanent loading marks placed on each side of the vessel forward and aft to indicate the maximum allowable trim and amidships to indicate the maximum allowable draft. A loading mark must be a horizontal line of at least 8 inches in length and 1 inch in height, with its upper edge passing through the point of maximum draft. The loading mark must be painted in a contrasting color to the sideshell paint. Loading marks not on vessel. Provide loading marks in accordance with your stability letter and communicate with MSC to ensure exact location. Stability letter may need updated to provide these marks.
46 CFR 185.602
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 November 2022
Resolved 20 November 2022
Resolution: Markings provided.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 11 October 2022
Resolved
The name of the vessel must be marked in clearly legible letters and numbers on each side of the life float. The number of persons capacity must be marked on each life float. Name of vessel not on both sides of float and number of passengers not on life float. Provide name and number on life float.
46 CFR 185.604
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 November 2022
Resolved 20 November 2022
Resolution: Name and number of passengers provided on life float.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 October 2022
Resolved
On a vessel of at least 26 ft, a visual and audible alarm must be provided at the operating station to indicate high water level in machinery space. Port engine room bilge high level visual indicator not operational. Provide bilge high level visual indicator.
46 CFR 182.530
Action required: 17 - Rectify deficiencies prior to departure
Due 11 October 2022
Resolved 12 October 2022
Resolution: Bilge visual indicator operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 October 2021
Resolved
The number of lifejackets must be marked in clearly legible 2 inch marking on container. Lifejacket number marking missing on forward containers. Provide proper marking.
46 CFR 185.604
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2021
Resolved 11 November 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 October 2021
Resolved
Remote fuel shutoff station must be marked in clearly legible 1 inch letters indicating purpose of the valve and direction of operation. Remote fuel shutoff marking missing. Provide proper marking.
46 CFR 185.608
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2021
Resolved 11 November 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 October 2021
Resolved
The design of standing rigging must be suitable for the intended service. Cracks showing on crossbeam on both port and starboard sides where chain plates connects. Provide repair proposal of cracked crossbeam and make repairs.
46 CFR 177.330
19 Nov 2021 - Beam found to be rotted. Vessel prohibited from raising sails or transiting under sail. Provide repair proposal and timeline.
Action required: 705 - Other - as specified
Due 13 November 2021
Resolved 31 May 2023
Resolution: Repairs completed per approved structural modification. See MSC letter H1-2300021.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 13 October 2021
Resolved
The construction of vessel must allow for safe operation to protect against damage. 02 soft spots on deck located in passenger accommodation area. Provide repair proposal and make repairs to soft deck.
46 CFR 177.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2021
Resolved 10 December 2021
Resolution: Proposal submitted. Temp repair in place until perm repair conducted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 October 2021
Resolved
Sail Rigging Preventative Maintenance Plan (PMP) not updated with all current configurations. In PMP provide sail plan, full rigging inventory, and inspection regime. Ensure all to log all inspections in accordance with vessel PMP. Keep copy of PMP on board vessel at all times and submitted revised version of PMP to [name withheld] 02-16
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2021
Resolved 17 December 2021
Resolution: PMP Provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 April 2021
Resolved
An EAP training program must be conducted for the employer's crewmembers and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crewmembers and Supervisory personnel must receive at least 60 minutes of training. Provide proof of completed EAP training for all personnel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2021
Resolved 6 May 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 November 2020
Resolved
Sail Rigging Preventative Maintenance Plan (PMP) not being utilized as designed. Daily, weekly, monthly, and semi-annual inspections not being conducted and/or logged as plan states in the past year. Provide full rigging inventory of all old and new rigging components. Begin to log all inspections in accordance with vessel PMP.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2020
Resolved 22 March 2021
Resolution: PMP provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 November 2020
Resolved
Bilge high water alarm visual indicator at helm showing same light for both compartments. A second light is mounted and supposed to operate separately for each space. Ensure system is set up as designed and as approved drawings indicate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2020
Resolved 8 February 2021
Resolution: System is now set up as designed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 25 November 2020
Resolved
Port lights missing hinged dead covers. Provide hinged dead covers for port lights.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2020
Resolved 19 May 2021
Resolution: Replaced hinged dead cover on port lights.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 25 November 2020
Resolved
Forward storage compartment starboard side has rotting frame. Remove rotted frame and make repairs to good wood.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2020
Resolved 19 May 2021
Resolution: Removed and replaced deck scantling in the fwd inboard hatch on the starboard side.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 November 2020
Resolved
Bolt on starboard forward chain plate holding crossbeam showing severe corrosion and not bedded down. Replace with new bolt.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2020
Resolved 19 May 2021
Resolution: The bolt was replaced on the fwd starboard chain plate.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 November 2020
Resolved
Clevis pin on aft port on running rigging at deck worn. Replace clevis pin.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2020
Resolved 8 February 2021
Resolution: New clevis pin installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 November 2020
Resolved
02 main sail cars disconnected from mast. Make all cars on main sail run the mast as designed.
Complete at next drydock.
Action required: 705 - Other - as specified
Due 24 December 2020
Resolved 19 May 2021
Resolution: The track was replaced on the mast.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 November 2020
Resolved
During inspection foresail/jib not installed/onboard. New sail being provided. Provide dimensions of new sail and show that new sail conforms with approved sail plan. Provide video of vessel under sail with new sail.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2020
Resolved 8 February 2021
Resolution: Foresail/jib installed.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 30 October 2019
Resolved
Port engine compartment bilge alarm was inoperative. Repair in accordance with 46 CFR 176.804.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 November 2019
Resolution: Bilge alarm satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 October 2019
Resolved
Port and stbd engine compartment Fireboy audible alarms were inoperative. Reapair in accordance with 46 CFR 176.810.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 November 2019
Resolution: Audible alarms satisfactory.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 30 October 2019
Resolved
DSC VHF radio was not provided. Provide in accordance with 46 CFR 184.502.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2019
Resolved 21 November 2019
Resolution: DSC VHF radio provided.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 30 October 2019
Resolved
6 port light dead covers were not provided. Provide covers in accordance with 46 CFR 176.802.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2019
Resolved 21 November 2019
Resolution: 6 deadlight covers provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 October 2019
Resolved
Wiring and associated terminal strip were not secured under mast step. Secure in accordance with 46 CFR 176.806.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2019
Resolved 21 November 2019
Resolution: Wiring and terminal strip under mast secured.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 October 2019
Resolved
Holes were present in port engine room forward watertight bulkhead. Seal bulkhead in accordance with 46 CFR 176.802.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2019
Resolved 21 November 2019
Resolution: Holes in port engine room watertight bulkheads were sealed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 October 2019
Resolved
Rigging Preventative Maintenance Plan was not provided. Provide in accordacne with 46 CFR 176.840.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2019
Resolved 21 November 2019
Resolution: Rigging Preventative Maintenance Plan was provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 October 2019
Resolved
Current Radio Safety Certificate was not provided. Provide in accordance with 46 CFR 184.502.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2019
Resolved 21 November 2019
Resolution: Radio Safety Certificate provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 October 2019
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2019
Resolved 21 November 2019
Resolution: FCC Station License provided.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 30 October 2019
Resolved
Proof of monthly EPIRB tests were not provided. Provide log in accordance with 46 CFR 185.728.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2019
Resolved 21 November 2019
Resolution: Monthly e-pirb test provided.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 30 October 2019
Resolved
2019 Coast Pilot [name withheld] and Tide Tables were not provided. Provide in accordance with 46 CFR 184.420.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2019
Resolved 21 November 2019
Resolution: Current Light List, Coast Pilot and Tide Tables provided.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 June 2019
Resolved
Provide Marine Inspector visual inspection of aluminum mast step in-kind to original design verified by the approved drawing prior to installation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 June 2019
Resolution: New in-kind mast step base plate provided for inspection.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 5 June 2019
Resolved
Following approval of mast step configuration and re-installation of mast, sea trials are to be conducted under sail propulsion by an attending Marine Inspector prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 June 2019
Resolution: Sea trial under sail conducted.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 11 October 2017
Resolved
Missing updated Radio Safety Certificate.
Condition: Invalid
Due 21 October 2017
Resolved 25 October 2017
Resolution: Provided.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 11 October 2017
Resolved
Extingushers and Installed system due for annual service.
Condition: Invalid
Due 1 November 2017
Resolved 26 October 2017
Resolution: Service completed.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 11 October 2017
Resolved
Provide rigging preventative maintenance plan.
Condition: Invalid
Due 11 November 2017
Resolved 13 November 2017
Resolution: Plan provided by surveyor [name withheld]
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 11 October 2017
Resolved
Missing one adult pfd. Limited to 50 persons total.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 17 October 2017
Resolution: PFD provided.