PUSH TOY

PUSH TOY is a 1996 tank barge. The Coast Guard has recorded 37 inspections since 1996, most recently in August 2022, along with 31 deficiencies.

Records from 1996 to 2022. Most recent: inspection, 3 August 2022.

Built
1996
Last inspected
3 August 2022
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

440599
Flag
UNITED STATES
Maury page id
psix-440599

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspections, by type

…with no type recorded2
Years with a record 25 calendar years (1996–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it79 - Regulatory (Subpart C or D), Gross Ton
79 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

PLOW-N-WATER Towing Vessel · MISLE 921752 · 1 September 2007 · activity 3052608

Inspection history · 37

3 August 2022 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7530859
2 March 2022 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7411091
27 May 2021 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7201225
28 January 2021 Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7132604
26 February 2020 COI Inspection · MTSA Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6921527
27 February 2019 MTSA Verification · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6630870
21 February 2018 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6359044
8 March 2017 Annual Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6101054
20 May 2016 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5881952
31 March 2016 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5844361
4 May 2015 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5117305
21 May 2014 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4848488
13 March 2012 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4230192
12 June 2010 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3748574
4 June 2009 Annual Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3474274
3 June 2008 Annual Inspection · MTSA Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3220382
1 September 2007 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3052608
6 June 2007 Annual Inspection · MTSA Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2946517
6 June 2006 MTSA Verification · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2666389
11 May 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2646334
10 May 2006 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2645836
31 January 2006 Cargo Tank Internal · Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2584916
6 October 2005 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2509282
14 June 2005 MTSA Verification · COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2376941
13 October 2004 Annual Inspection · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2086449
19 June 2003 Periodic Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1899267
4 June 2002 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1626100
12 September 2001 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1072410
4 June 2001 Hull Examination · Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1362278
19 July 2000 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1427871
18 July 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 227620
14 July 1999 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1388863
17 June 1998 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1386300
9 February 1998 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1109935
19 June 1997 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 777118
10 April 1997 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1392660
2 July 1996 Hull Examination · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1425787

Deficiency record · 31

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 27 May 2021 Resolved
There is a gap between the flame screen bowl and the flange on the pressure relief valve which is mounted next to the PV valve on the tank dome. The gap is not vapor-tight and essentially bypasses the flame screen and leaves the tanks in an open-vented configuration at all times. Add a gasket or otherwise modify the configuration in order to make the pressure relief valve vapor-tight.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 June 2021
Resolved 9 July 2021
Resolution: Received pictures of gasket fitted in the pressure relieve valve.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Loading instrument
Issued 27 May 2021 Resolved
Provide documentation showing that the cargo tank gauging connectors which are fitted within the hazardous area are intrinsically safe.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 June 2021
Resolved 15 July 2021
Resolution: Class 1 Div 1 compliant fittings were installed on the level probe. Pictures of the installation and C1D1 documentation were submitted by email.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 27 February 2019 Resolved
Re-establish benzene monitoring program and follow safety procedures prior to next loading operation.
Action required: 705 - Other - as specified
Due 30 April 2019
Resolved 11 June 2020
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Loading instrument
Issued 27 February 2019 Resolved
Prove wiring to gauging system is intrinsically safe or explosion proof.
Action required: 705 - Other - as specified
Due 1 March 2019
Resolved 5 March 2019
Resolution: Received cut sheet of system showing instrinsically safe.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Lighting
Issued 27 February 2018 Resolved
Install approved intrinsically safe, explosionproof, or purged and pressurized electrical equipment (switches, fuses, battery boxes, lights, chargers) and through runs of marine shipboard cable in accordance with 46CFR111.105.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 March 2018
Resolved 6 April 2018
Resolution: Electrical equipment removed, C1-D2 portable barge lights installed no closer than 10 Ft from cargo openings.
Electrical › Electrical Distribution System (service) › Cable
Issued 12 June 2010 Resolved
Replace cargo pump control cable gaskets.
Action required: 705 - Other - as specified
Due 12 July 2010
Resolved 19 November 2010
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 12 June 2010 Resolved
Replace cargo pump actuator for cargo pumps #1, 2, and 3.
Action required: 705 - Other - as specified
Due 12 July 2010
Resolved 22 September 2010
Construction/Loadline › Structures › Manhole
Issued 3 June 2008 Resolved
Repair damaged port bow rake hatch hinge.
Due 3 July 2008
Resolved 7 June 2008
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 3 June 2008 Resolved
Place updated (most recent) V.R.P. on barge.
Due 3 July 2008
Resolved 7 June 2008
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 3 June 2008 Resolved
Secure extra portable fire extinguisher.
Due 3 July 2008
Resolved 7 June 2008
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 6 June 2006 Resolved
Provide snap ring clips on ullage PV vents where missing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 July 2006
Resolved 6 July 2006
Deck/Cargo › Towing › Winch
Issued 6 June 2006 Resolved
Prove proper operation of towing winches--springs broken &/ missing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 July 2006
Resolved 30 September 2006
Resolution: Bought & installed new winches.
Deck/Cargo › Towing › Towline
Issued 6 June 2006 Resolved
Provide evidence of towing gear (wire) maintenance.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 July 2006
Resolved 30 September 2006
Resolution: Purchased & installed new towing wire.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 31 January 2006 Resolved
Properly and permanently install draft marks.
Condition: Improper Installation
Action required: 703 - Prior to bunkering operations
Resolved 31 January 2006
Resolution: New marks welded
Construction/Loadline › Hull › Hull Plating
Issued 31 January 2006 Resolved
Provide complete gauging report of hull plate in 6 ft transverse girth belts. Sample 2 shots on narrow plates and 3 shots on wide plates.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 31 January 2006
Resolution: Gauging and report submitted, within tolerances.
Construction/Loadline › Hull › Side Shell
Issued 31 January 2006 Resolved
Grind and weld longitudinal seams port & stbd at wind sand water strakes where wasted.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 31 January 2006
Resolution: G/W
Construction/Loadline › Hull › Hull Plating
Issued 31 January 2006 Resolved
Clad weld pits over 25% wastage of original plate.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 31 January 2006
Resolution: Report submitted, pictures approved.
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 22 June 2005 Resolved
Develop and implement transfer procedures and maintain a copy on board barge
Due 23 July 2005
Resolved 7 September 2005
Resolution: Operqated provided photos and e-mail showing three remaining deficiencies corrected. None remain outstyanding.
Documentation › Markings/Placards › Oil Discharge Placard
Issued 22 June 2005 Resolved
Post discharge placard
Due 23 July 2005
Resolved 7 September 2005
Resolution: Placard was installed.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 22 June 2005 Resolved
Mark P/S bow with vessel name
Due 23 July 2005
Resolved 7 September 2005
Resolution: Operator provided photos showing name installed on P/S bow.
Deck/Cargo › Holds/Tanks › Ullage
Issued 13 October 2004 Resolved
Replace gaskets in way of ullage opening PV vents IAW vent design specifications. 46 CFR 32.20-5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 November 2004
Resolved 1 November 2004
Resolution: Gaskets replaced
Deck/Cargo › Vapor Control Systems › Vessel Vapor Overpressure/Vacuum Protection
Issued 19 June 2003 Resolved
Renew gaskets IWO ullage openings and P/V breakers.
Condition: Improper/Lack of Maintenance
Due 19 July 2003
Resolved 15 August 2003
Resolution: New gasket kits installed on all ullage openings and PV breakers.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Electric Bonding
Issued 19 June 2003 Resolved
Provide adequate length bonding cable to reach from barge to the Wahweep fuel transfer manifold grounding assembly.
Due 19 July 2003
Resolved 15 August 2003
Resolution: Additional bonding cable reel was installed on the bow of the vessel.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 4 June 2002 Resolved
Repair connections to dock (4) to prevent chafing on barge.
Due 12 June 2002
Resolved 1 November 2004
Deck/Cargo
Issued 10 April 1997 Resolved
Renew as required electrical fitting on shore tie connection for cargo pumps at Dangling Rope Marina. all fitting and connections must be for use in a hazardous location (Division I Group D installation).
Condition: Unknown
Due 10 April 1997
Resolved 10 April 1997
Documentation
Issued 10 April 1997 Resolved
Update vessel response plan._x001C_
Condition: Unknown
Due 10 April 1997
Resolved 10 April 1997
Deck/Cargo
Issued 10 April 1997 Resolved
Hydro test and properly mark all cargo transfer hoses._x001C_
Condition: Unknown
Due 28 April 1997
Resolved 28 April 1997
Deck/Cargo
Issued 10 April 1997 Resolved
Properly complete Transfer Declaration prior to transfering cargo._x001C_
Condition: Unknown
Due 28 April 1997
Resolved 28 April 1997
Deck/Cargo
Issued 10 April 1997 Resolved
Renew discharge cargo hoses of proper type._x001C_
Condition: Unknown
Due 28 April 1997
Resolved 28 April 1997
Deck/Cargo
Issued 10 April 1997 Resolved
Renew as required all electrical fitting in the barge gauging system that are not of proper type for hazardous location._x001C_
Condition: Unknown
Due 10 April 1997
Resolved 10 April 1997
Documentation
Issued 2 July 1996 Resolved
Provide stability and residual hull strength calculations as required by 33CFR155.245_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 July 1996
Resolved 9 October 1996

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.