Records from 1985 to 1995. Most recent: inspection, 13 July 1995.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 23
13 July 1995
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1181368
13 May 1994
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1439508
3 June 1993
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1137473
19 January 1993
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 222940
19 November 1992
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1139054
30 October 1992
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 933199
17 July 1992
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1254583
4 June 1992
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 950026
15 November 1991
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 933656
11 June 1991
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 888220
17 January 1991
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 926614
6 June 1990
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 915561
17 January 1990
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1223817
24 November 1989
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 917756
6 July 1989
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1340705
19 December 1988
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1342866
17 June 1988
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1202185
24 June 1987
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1001593
11 June 1987
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1335696
7 November 1986
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1012423
16 June 1986
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1302566
10 June 1985
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1293630
25 April 1985
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 981114
Documentation
Issued 3 June 1993
Resolved
PROVIDE DRUG TESTING DOCUMENTATION.
Condition: Unknown
Due 3 June 1993
Resolved 3 June 1993
Engineering
Issued 3 June 1993
Resolved
REPAIR OR RENEW THE PORT MAIN DIESEL ENGINE EXHAUST PIPING RAISER.
Condition: Unknown
Due 3 June 1993
Resolved 3 June 1993
Engineering
Issued 30 October 1992
Resolved
PROVIDE AND INSTALL FLAME SCREENS FOR PORT AND STBD FUEL TANK VENTS.
Condition: Unknown
Due 30 October 1992
Resolved 30 October 1992
Navigation
Issued 30 October 1992
Resolved
REPLACE AND RELOCATE EXISTING MASTHEAD LIGHT IN ACCORDANCE WITH 72 COLREGS RULES 21, 22 AND ANNEX I. VESSEL LIMITED TO DAYTIME USE ONLY UNTIL VERIFIEDBY ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 30 October 1992
Resolved 30 October 1992
Accommodation/Occupational Safety
Issued 30 October 1992
Resolved
PROVIDE AND INSTALL GOOSENECKS FOR ALL MAIN DECK VENTILATION PIPES.
Condition: Unknown
Due 30 October 1992
Resolved 30 October 1992
Accommodation/Occupational Safety
Issued 4 June 1992
Resolved
PROVIDE HANDRAIL 12" SPACE COURSE SECTIONS FOR UPPER CREW DECK HANDRAILS ADJACENT TO PILOT HOUSE.
Condition: Unknown
Due 4 June 1992
Resolved 4 June 1992
Accommodation/Occupational Safety
Issued 4 June 1992
Resolved
PROVIDE TWO WASH BASIN UNITS FOR BOTH HEADS.
Condition: Unknown
Due 4 June 1992
Resolved 4 June 1992
Construction/Loadline
Issued 4 June 1992
Resolved
PROVIDE A OIL POLLUTION DICHARGE PLACARD.
Condition: Unknown
Due 4 June 1992
Resolved 4 June 1992
Accommodation/Occupational Safety
Issued 4 June 1992
Resolved
PROVIDE A MARPOL V PLACARD AND WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 4 June 1992
Resolved 4 June 1992
Fire Fighting
Issued 4 June 1992
Resolved
SERVICE ALL HAND PORTABLE FIRE EXTINGUSHERS.
Condition: Unknown
Due 4 June 1992
Resolved 4 June 1992
Construction/Loadline
Issued 4 June 1992
Resolved
REWIRE WITH PROPER CONNECTIONS, 12V BILGE PUMP WIRING IN THE FUEL OIL COMPARTMENT AND ENGINE COMPARTMENT.
Condition: Unknown
Due 4 June 1992
Resolved 4 June 1992
Accommodation/Occupational Safety
Issued 4 June 1992
Resolved
REFASTEN THE LADDER TO THE STEERING COMPARTMENT.
Condition: Unknown
Due 4 June 1992
Resolved 4 June 1992
Electrical
Issued 4 June 1992
Resolved
REMOVE ALL 12V ELECTRICAL WIRING DEAD ENDS FROM THE ENGINE COMPARTMENT.
Condition: Unknown
Due 4 June 1992
Resolved 4 June 1992
Lifesaving
Issued 4 June 1992
Resolved
REMARK VESSELS RING BUOY WITH VESSELS NAME. PROVIDE GRAB LINES OR REMOVE SECOND RING BUOY FROM VESSEL.
Condition: Unknown
Due 4 June 1992
Resolved 4 June 1992
Lifesaving
Issued 4 June 1992
Resolved
RECONNECT THE LIFE FLOAT/BUOYANT APPARATUS FLOAT FREE LINK TO THE DECK OF THE VESSEL.
Condition: Unknown
Due 4 June 1992
Resolved 4 June 1992
Electrical
Issued 4 June 1992
Resolved
PROVIDE A COVER FOR THE PILOT HOUSE ELECTRICAL BREAKER PANEL.
Condition: Unknown
Due 4 June 1992
Resolved 4 June 1992
Lifesaving
Issued 4 June 1992
Resolved
REPLACE AS NEEDED WORN LIFE PRESERVER RETROREFLECTIVE TAPE MATERIAL.
Condition: Unknown
Due 4 June 1992
Resolved 4 June 1992
Accommodation/Occupational Safety
Issued 17 January 1990
Resolved
REBRACKET EXTERIOR SEATING, ALL-AROUND.
Condition: Unknown
Due 17 January 1990
Resolved 17 January 1990
Construction/Loadline
Issued 17 January 1990
Resolved
IN CONJUNCTION WITH REPAIRS TO LAZARETTE AREA, SCARF & RENEW ALL ROTTED DECK FRAMES ASSOCIATED WITH THAT AREA.
Condition: Unknown
Due 17 January 1990
Resolved 17 January 1990
Construction/Loadline
Issued 17 January 1990
Resolved
NEAR LAZARETTE, RENEW MAIN DECK PORT SIDE FROM DECK HOUSE TO TRANSOM, INCLUDING AREA NEAR BAIT BOXES AND SURROUNDING LAZARETTE HATCH.
Condition: Unknown
Due 17 January 1990
Resolved 17 January 1990
Construction/Loadline
Issued 17 January 1990
Resolved
MAKE FOREPEAK HATCH WATERTIGHT.
Condition: Unknown
Due 17 January 1990
Resolved 17 January 1990
Construction/Loadline
Issued 17 January 1990
Resolved
REATTACH #S ONE, NINE AND TEN FLOOR TIMBERS, FWD HOLD.
Condition: Unknown
Due 17 January 1990
Resolved 17 January 1990
Construction/Loadline
Issued 17 January 1990
Resolved
REPLACE LAZERETTE HATCH WITH WATERTIGHT HATCH.
Condition: Unknown
Due 17 January 1990
Resolved 17 January 1990
Construction/Loadline
Issued 17 June 1988
Resolved
PROVIDE SECURING LINE TO ALL MANHOLE COVERS ON DECK.
Condition: Unknown
Due 17 June 1988
Resolved 17 June 1988
Lifesaving
Issued 17 June 1988
Resolved
REPLACE LIFELINES TO ALL LIFEFOATS WITH FLOATABLE LINES OR ATTACH SIENE FLOATS TO EXSISTING LINES.
Condition: Unknown
Due 17 June 1988
Resolved 17 June 1988
Lifesaving
Issued 17 June 1988
Resolved
REPLACE WATERLIGHT TO LIFE RING
Condition: Unknown
Due 17 June 1988
Resolved 17 June 1988
Navigation
Issued 17 June 1988
Resolved
REPLACE STERN LIGHT
Condition: Unknown
Due 17 June 1988
Resolved 17 June 1988
Navigation
Issued 17 June 1988
Resolved
RELOCATE MASTHEAD AND SIDE LIGHTS TO COMPLY WITH RULES OF THE ROAD
Condition: Unknown
Due 17 June 1988
Resolved 17 June 1988
Construction/Loadline
Issued 17 June 1988
Resolved
REPLACE HATCH COVER TO FWD COMPARTMENT.
Condition: Unknown
Due 17 June 1988
Resolved 17 June 1988
Construction/Loadline
Issued 17 June 1988
Resolved
REPLACE CRACKED WINDOW MAIN DECK STBD.
Condition: Unknown
Due 17 June 1988
Resolved 17 June 1988
Engineering
Issued 24 June 1987
Resolved
RENEW THE PORT FUEL TANK AT THE NEXT SCHEDULED DRYDOCK BUT NOT LATER THAN 31DEC88.
Condition: Unknown
Due 24 June 1987
Resolved 24 June 1987
Construction/Loadline
Issued 24 June 1987
Resolved
IN THE ENGINE ROOM, RENEW ON THE PORT AND STBD DECK BEAMS AS FOLLOWS: P-1,2,5; S-1,2,5,7,8,9.
Condition: Unknown
Due 24 June 1987
Resolved 24 June 1987
Lifesaving
Issued 11 June 1987
Resolved
REPLACE RING BUOY ON STARBOARD SIDE.
Condition: Unknown
Due 11 June 1987
Resolved 11 June 1987
Engineering
Issued 11 June 1987
Resolved
REPLACE SCREEN ON STARBOARD FUEL TANK VENT.
Condition: Unknown
Due 11 June 1987
Resolved 11 June 1987
Construction/Loadline
Issued 11 June 1987
Resolved
REFASTEN ALL BUTT BLOCKS IN #2 HOLD.
Condition: Unknown
Due 11 June 1987
Resolved 11 June 1987
Navigation
Issued 11 June 1987
Resolved
REPALCE LENS IN PORT RUNNING LIGHT.
Condition: Unknown
Due 11 June 1987
Resolved 11 June 1987
Navigation
Issued 11 June 1987
Resolved
ADJUST OR RENEW BALL JOINT AT STEERING BOX TO LINKAGE TO PORT RUDDER.
Condition: Unknown
Due 11 June 1987
Resolved 11 June 1987
Construction/Loadline
Issued 11 June 1987
Resolved
VESSEL TO DRYDOCK AND REPAIR LEAKAGE IN CHINE, PORT AND STARBOARD SIDES IN #2 COMPARTMENT FROM AFT BULKHEAD AND FORWARD 5 FRAME SPACES.
Condition: Unknown
Due 11 June 1987
Resolved 11 June 1987
Construction/Loadline
Issued 25 April 1985
Resolved
SCRAPE DOWN INTERNAL HULL MEMBERS IN WAY OF ENGINE ROOM TO REMOVE FUZZY WOOD ROT. TO BE EXAMINED BY A CG INSPECTOR TO DETERMINE IF FUTURE REPAIRS REQUIRED.
Condition: Unknown
Due 25 April 1985
Resolved 25 April 1985
Unknown
Issued 25 April 1985
Resolved
CLEAN ENGINE ROOM BILGES.
Condition: Unknown
Due 25 April 1985
Resolved 25 April 1985