MAURY USCG vessel records Sign in
← All vessels

LINEKEN ISLANDER

LINEKEN ISLANDER is a 1961 tank ship. The Coast Guard has recorded 49 inspections since 1985, most recently in June 2008, along with 59 deficiencies — 17 with no resolution recorded — and 2 operational controls.

Records from 1985 to 2008. Most recent: inspection, 5 June 2008.

Built
1961
Last inspected
5 June 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WR3274
Flag
UNITED STATES
—
Maury page id
psix-44062

Inspections, by type

…with no type recorded4
Years with a record 22 calendar years (1985–2008)
The 49 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it79 - Regulatory (Subpart C or D), Gross Ton
53 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WBF7173MMSI not assigned · expired · compulsorily equipped · granted 15 January 1997, cancelled 1 July 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MISS GATEWAY Passenger (Inspected) · MISLE 54207 · 27 September 2001 · activity 16658

Inspection history · 49

5 June 2008 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3228294
28 March 2005 MTSA Verification · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2323770
9 November 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2237777
8 September 2004 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2197430
15 May 2003 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1793917
14 June 2002 Deficiency Check · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1630840
23 October 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 184532
27 September 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 16658
5 June 2001 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1469359
8 January 2001 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1379265
9 September 2000 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 822394
13 July 2000 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1052026
29 June 1999 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1079863
13 August 1998 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1131333
8 July 1998 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1129148
28 April 1998 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 789449
7 August 1997 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 776657
25 July 1997 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1112110
22 July 1997 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 776766
1 July 1997 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 776762
30 June 1997 COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1121969
24 June 1996 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1243371
20 June 1996 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1078204
6 December 1995 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 875664
25 July 1995 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 882007
30 June 1995 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1190488
27 June 1994 Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 869624
26 July 1993 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1156348
7 July 1993 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1152464
6 May 1993 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 960652
23 July 1992 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 955768
23 June 1992 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 953330
16 July 1991 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1249473
9 July 1991 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1248560
6 November 1990 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1224879
16 July 1990 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1232946
27 July 1989 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 891266
7 July 1989 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1038527
4 April 1988 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1301227
6 January 1988 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1009804
19 November 1987 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1026257
3 November 1987 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1332663
19 October 1987 Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1016485
7 July 1987 MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1013513
7 July 1987 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1334722
30 May 1986 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 993977
18 October 1985 Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1300479
9 August 1985 Type not recorded
No type recorded · COTP NEW HAVEN · USCG Northeast District (CGD-NE) · Activity 476638
21 May 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1289801

Deficiency record · 59

Operations/Management › Pollution › Control of Discharge of Oil
Issued 8 September 2004 No resolution recorded
Tanker has not submitted a Vessel Response Plan to G-MOR for review and approval.
Action required: 701 - Prior to carriage of passengers/cargo
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 8 September 2004 No resolution recorded
Tanker does not have Oil Transfer Procedures aboard.
Action required: 701 - Prior to carriage of passengers/cargo
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 8 September 2004 No resolution recorded
Tanker has no Notice to Mariners aboard.
Action required: 17 - Rectify deficiencies prior to departure
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 8 September 2004 No resolution recorded
Tanker does not have an unofficial logbook.
Action required: 17 - Rectify deficiencies prior to departure
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 8 September 2004 No resolution recorded
Tanker does not have a Fire Control Plan.
Action required: 17 - Rectify deficiencies prior to departure
Operations/Management › Drills/Instruction › Safety Orientation
Issued 8 September 2004 No resolution recorded
Station Bill not posted.
Action required: 17 - Rectify deficiencies prior to departure
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 8 September 2004 No resolution recorded
Fire fighting equipments need annual servicing.
Action required: 17 - Rectify deficiencies prior to departure
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 8 September 2004 No resolution recorded
Cargo hoses and pipes not hydrostatically tested.
Action required: 701 - Prior to carriage of passengers/cargo
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 8 September 2004 No resolution recorded
Tanker must demonstrate automatic shut-down of the MDE upon overspeed and low lube oil pressure.
Action required: 17 - Rectify deficiencies prior to departure
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 8 September 2004 No resolution recorded
Lagging is needed on the exhaust manifold of the MDE.
Action required: 17 - Rectify deficiencies prior to departure
Electrical › Electrical Distribution System (emergency) › Cable
Issued 8 September 2004 No resolution recorded
Batteries and liners must be cleaned of corrosion.
Action required: 17 - Rectify deficiencies prior to departure
Electrical › Electrical Distribution System (service) › Cable
Issued 8 September 2004 No resolution recorded
Plastic wire ties in horizontal runs of the engine room overhead must be replaced.
Action required: 17 - Rectify deficiencies prior to departure
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 8 September 2004 No resolution recorded
A marine chemist certificate is needed in order to make the pumproom ready for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Operations/Management › Drills/Instruction › Safety Orientation
Issued 8 September 2004 No resolution recorded
Engine escape hatch must be labeled.
Action required: 17 - Rectify deficiencies prior to departure
Engineering › Steering Gear System › Motor
Issued 8 September 2004 No resolution recorded
Tanker must demonstrate the proper operation of the steering system in remote and manual controls.
Action required: 17 - Rectify deficiencies prior to departure
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 8 September 2004 No resolution recorded
The cargo hose manifold does not have adequate containment underneath it.
Action required: 701 - Prior to carriage of passengers/cargo
Pollution Prevention/Response › Prevention Equipment › Coamings
Issued 8 September 2004 No resolution recorded
The aft coaming is not leak-free.
Action required: 701 - Prior to carriage of passengers/cargo
Documentation › Logs/Records
Issued 14 June 2002 Resolved
Provide proof of Drug and Alcohol Program participation. LEGACY COMPONENT DESC: Drug Test Records
Condition: Improper/Lack of Maintenance
Due 17 July 2002
Resolved 2 July 2002
Resolution: Submitted sat paperwork.
Navigation › Piloting/Steering
Issued 14 June 2002 Resolved
Provide current compass deviation table. LEGACY COMPONENT DESC: Deviation Table/Graph
Condition: Improper/Lack of Maintenance
Due 17 July 2002
Resolved 2 July 2002
Resolution: Completed sat.
Navigation › Piloting/Steering
Issued 14 June 2002 Resolved
Provide updated tides/currents/Notice to Mariner's and Coastal Pilot information. LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Condition: Improper/Lack of Maintenance
Due 17 July 2002
Resolved 2 July 2002
Resolution: Completed sat.
Deck/Cargo › Cargo Stowage
Issued 14 June 2002 Resolved
Prove proper operation of Combustible Gas Indicator. LEGACY COMPONENT DESC: Combustible Gas Indicator
Condition: Improper/Lack of Maintenance
Due 17 July 2002
Resolved 2 July 2002
Resolution: Completed sat.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 14 June 2002 Resolved
Prove proper operation of Stbd tachometer. LEGACY COMPONENT DESC: Tachometer
Condition: Improper/Lack of Maintenance
Due 17 July 2002
Resolved 2 July 2002
Resolution: Completed sat.
Lifesaving › Lifebuoys
Issued 14 June 2002 Resolved
Repair/replace stbd lifering, place retro tape on port lifering. LEGACY COMPONENT DESC: Markings (ship name/port)
Condition: Improper/Lack of Maintenance
Due 17 July 2002
Resolved 2 July 2002
Resolution: Completed sat.
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 14 June 2002 Resolved
Repair/replace salt water cooling pump on generator.
Condition: Improper/Lack of Maintenance
Due 17 July 2002
Resolved 2 July 2002
Resolution: Completed sat.
Electrical › Electric Generation Source (service)
Issued 14 June 2002 Resolved
Drain and dry out battery trays.
Condition: Improper/Lack of Maintenance
Due 17 July 2002
Resolved 2 July 2002
Resolution: Completed sat.
Documentation
Issued 8 January 2001 Resolved
COMPLETE SECTION MODULUS IAW 46CFR31.01-21(A).
Condition: Unknown
Due 8 January 2001
Resolved 8 January 2001
Navigation
Issued 13 July 2000 Resolved
Provide valid tide and current tables.
Condition: Unknown
Due 13 July 2000
Resolved 13 July 2000
Lifesaving
Issued 13 July 2000 Resolved
Prove operation of port deck floodlight.
Condition: Unknown
Due 13 July 2000
Resolved 13 July 2000
Engineering
Issued 13 July 2000 Resolved
Prove proper operation of stbd main engine remote shutdown from wheelhouse.
Condition: Unknown
Due 13 July 2000
Resolved 13 July 2000
Accommodation/Occupational Safety
Issued 8 July 1998 Resolved
remove all flammable carpet and rugs from accom space.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Electrical
Issued 8 July 1998 Resolved
Vessel to remove all extension cords. Currently vessel is utilizing extension cords to power systems permanently.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Electrical
Issued 8 July 1998 Resolved
Vessel to demonstrate proper operation of port MDE charging system. After testing E-shutdowns engine couldnt be started due to low battery power.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Lifesaving
Issued 8 July 1998 Resolved
Replace nylon line on ringbouy with polypropelene.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Lifesaving
Issued 8 July 1998 Resolved
Remove inoperative fuel oil burner from stove and cap off line.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Lifesaving
Issued 8 July 1998 Resolved
Remove portable electric cooking equipment from accom space.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Fire Fighting
Issued 22 July 1997 Resolved
Submit plans for new 1 1/2" fire main installation IAW 46 CFR 50.20 for approval by local OCMI.
Condition: Unknown
Due 5 August 1997
Resolved 20 October 1997
Documentation
Issued 30 June 1997 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 1 July 1997
Resolved 20 October 1997
Engineering
Issued 30 June 1997 Resolved
Correct oil transfer procedures iaw 33 CFR 155, subpart C.
Condition: Unknown
Due 14 July 1997
Resolved 20 October 1997
Fire Fighting
Issued 30 June 1997 Resolved
Bring vessel firefighting (i.e. 1 1/2" hoses, combo nozzles, hydrant outlets) into compliance with 46 CFR 34.10-90.
Condition: Unknown
Due 14 July 1997
Resolved 20 October 1997
Accommodation/Occupational Safety
Issued 30 June 1997 Resolved
Clean/reorganize crew overnight accommodation space.
Condition: Unknown
Due 14 July 1997
Resolved 20 October 1997
Documentation
Issued 30 June 1997 Resolved
Provide proper documentation of fully compliant chemical testing program for the following deficiencies: crew list updates/ preemployment testing/ employee assistance program. Marine employer is not authorized to operate after 30JUL97 unless this requirement has been cleared by CG inspector.
Condition: Unknown
Due 30 July 1997
Resolved 20 October 1997
Fire Fighting
Issued 30 June 1997 Resolved
Perform satisfactory test for inspector demonstrating that existing fire pump output is equal to or greater than 50gpm.
Condition: Unknown
Due 14 July 1997
Resolved 20 October 1997
Construction/Loadline
Issued 6 December 1995 Resolved
PROVIDE A COMPLETED SECTION MODULUS OF VESSEL.
Condition: Unknown
Due 6 February 1996
Resolved 20 June 1996
Construction/Loadline
Issued 6 December 1995 Resolved
PROVIDE A SMOOTH COPY OF THICKNESS GUAGINGS.
Condition: Unknown
Due 13 December 1995
Resolved 20 June 1996
Fire Fighting
Issued 30 June 1995 Resolved
PROVIDE PROOF OF SAT HYDROSTATIC TESTING OF ALL CO2 FIXED CYLINDERS PRIOR_x001C_ TO 31JUL95.
Condition: Unknown
Due 30 June 1995
Resolved 30 June 1995
Documentation
Issued 7 July 1993 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 11 August 1993
Resolved 11 August 1993
Deck/Cargo
Issued 23 June 1992 Resolved
REPAIR VENT TO PUMPROOM & INCLUDE NEW FLAME SCREEN._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 August 1992
Resolved 12 August 1992
Navigation
Issued 23 June 1992 Resolved
PLACE ON BOARD AN ACCURATE MAG. COMPASS DEVIATION CARD/TABLE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 August 1992
Resolved 12 August 1992
Lifesaving
Issued 9 July 1991 Resolved
RESTRICTED TO RIVERS ROUTE-BETWEEN EXECUTION ROCKS AND THE VERRANZANO BRIDGE, WITH A BUOYANT APPARATUS ON BOARD UNTIL A PROPERLY SERVICED LIFERAFT CAN BE PROVIDED.
Condition: Unknown
Due 9 July 1991
Resolved 9 July 1991
Lifesaving
Issued 16 July 1990 Resolved
HAVE VESSEL'S LIFERAFT AND HYDROSTATIC RELEASE UNIT SERVICED.
Condition: Unknown
Due 16 July 1990
Resolved 16 July 1990
Fire Fighting
Issued 16 July 1990 Resolved
HAVE (3) THREE CO2 CYLINDERS FOR FIXED SYSTEM HYDROSTATICALLY TESTED.
Condition: Unknown
Due 16 July 1990
Resolved 16 July 1990
Electrical
Issued 7 July 1989 Resolved
PROVIDE GLOBES FOR THE 3 LIGHT FIXTURES LOCATED IN PASSAGEWAY AND WORKSHOP.
Condition: Unknown
Due 7 July 1989
Resolved 7 July 1989
Fire Fighting
Issued 7 July 1989 Resolved
PROPERLY LABEL FIXED CO2 PULL STATION ON STBD SIDE OF WHEELHOUSE.
Condition: Unknown
Due 7 July 1989
Resolved 7 July 1989
Electrical
Issued 19 October 1987 Resolved
RENEW TWO KNIFE SWITCHES LOCATED ABOVE BATTERY BANK AND REPALCE WITH EXPLO-SION PROOF SWITCHES.
Condition: Unknown
Due 19 October 1987
Resolved 19 October 1987
Fire Fighting
Issued 7 July 1987 Resolved
SECURE FIXED AND PORTABLE FIREFIGHTING EQUIPMENT.
Condition: Unknown
Due 7 July 1987
Resolved 7 July 1987
Documentation
Issued 7 July 1987 Resolved
PROVIDE CERTIFICATED LIFEBOATMAN.
Condition: Unknown
Due 7 July 1987
Resolved 7 July 1987
Construction/Loadline
Issued 7 July 1987 Resolved
RENEW GASKET IN PORT SIDE BRIDGE WATERTIGHT DOOR.
Condition: Unknown
Due 7 July 1987
Resolved 7 July 1987
Documentation
Issued 7 July 1987 Resolved
PROVIDE CURRENT RADIO STATION LICENSE.
Condition: Unknown
Due 7 July 1987
Resolved 7 July 1987
Navigation
Issued 7 July 1987 Resolved
PROVIDE STERN LIGHT.
Condition: Unknown
Due 7 July 1987
Resolved 7 July 1987

Ownership record