APOLLO

APOLLO is a 1996 freight ship. The Coast Guard has recorded 15 inspections since 1996, most recently in December 2009, along with 4 deficiencies and 1 operational control.

Records from 1996 to 2009. Most recent: inspection, 21 December 2009.

Built
1996
Last inspected
21 December 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9136773 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
440659
Flag
PANAMA
—
Maury page id
psix-440659

Inspections, by type

…with no type recorded7
Years with a record 12 calendar years (1996–2009)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it10015 - Convention (Subpart B), Net Ton
18108 - Convention (Subpart B), Gross Ton
27912 - Dead Weight, Ton
34901 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 15

21 December 2009 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3653384
26 December 2008 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3385013
25 June 2007 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2973084
31 May 2006 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2666071
21 September 2005 NPV Safety Exam · MARPOL Annex V Examination · Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2497283
1 April 2005 Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2324690
29 November 2004 Ballast Water Examination · PII Safety Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2249985
12 August 2004 ISPS II Exam
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2162059
5 April 2004 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2037692
19 August 2003 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1880700
21 February 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 287468
5 January 2000 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 436197
16 January 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 424621
14 January 1998 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 411511
9 September 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 395246

Deficiency record · 4

Engineering › Diesel Engine (auxiliary) › Waste Heat Recovery
Issued 21 September 2005 Resolved
The Sea Water main intake pipe has two temporary band clamp patches.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2005
Resolved 31 May 2006
Resolution: Received classification society report attesting to satisfactory permanent repairs.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 29 November 2004 Resolved
LOW LEVEL ALARM FOR HYDRAULIC FLUID LEAKAGE ON STEERING PUMP NO. 2 DID NOT PRODUCE AN AUDIBLE AND VISUAL ALARM ON THE BRIDGE. CITE SOLAS II-1, REG. 29, 12.2.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 January 2005
Resolved 8 December 2004
Resolution: RECIEVED A FAX STATING THE ALARM WAS REPAIRED. RETURNED TO THE SHIP TO VERIFY. DEFICIENCY CLEARED.
Lifesaving
Issued 21 February 2001 Resolved
PORT LIFE BOAT REMOTE RELAESE BRAKE CABLE NOT PROPERLY RIGGED, DOES NOT PERMIT LOWERING OF BOAT TO THE WATER. CORRECT AND PROVIDE CLASS REPORT PRIOR TO DEPARTURE.
Condition: Unknown
Due 21 February 2001
Resolved 22 February 2001
Fire Fighting
Issued 5 January 2000 Resolved
MISSING SPANNER WRENCHES FROM ALL FIRE STATIONS. SOLAS 74 UNAMENDED-CHAPTERII-2/REG 4.7.1. TO BE CORRECTED PRIOR TO RETURNING TO THE UNITED STATES OR NEXT U.S. PORT.
Condition: Unknown
Due 25 April 2000
Resolved 25 April 2000

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.