Records from 1985 to 2007. Most recent: inspection, 28 June 2007.
Inspection history · 24
28 June 2007
Type not recorded
No type recorded · Station Ocean City · USCG East District (CGD-E) · Activity 2976139
27 June 2007
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2976428
4 March 1994
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1165510
6 January 1994
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 668634
5 December 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 113625
5 December 1993
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 231793
16 August 1993
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 45079
26 April 1993
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 840828
25 March 1993
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1149893
27 April 1992
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 944327
12 July 1991
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1248918
30 April 1991
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1240498
22 April 1991
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 929813
26 December 1990
Drydock Extension
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 916979
10 April 1990
Re-Inspection · Deficiency Check · Drydock Extension
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 926711
24 May 1989
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1204900
4 April 1989
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1209064
30 December 1988
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1037161
14 April 1988
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1039670
29 March 1988
COI Inspection · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1297915
15 April 1987
Hull Examination · Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1018623
7 January 1987
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1002637
20 May 1986
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1301128
1 April 1985
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1291763
Construction/Loadline
Issued 25 March 1993
Resolved
VESSEL MUST HAVE ENG ROOM BILGE CLEANED AND OIL REMOVED PRIOR TO OPERATION.
Condition: Unknown
Due 25 March 1993
Resolved 25 March 1993
Navigation
Issued 25 March 1993
Resolved
VESSEL MUST HAVE BOLTS TIGHTEN UP ON HYDRAULIC RAM PRIOR TO OPERATION.
Condition: Unknown
Due 25 March 1993
Resolved 25 March 1993
Navigation
Issued 25 March 1993
Resolved
VESSEL MUST HAVE LEAKING HYDRAULIC LINE REPLACED PRIOR TO OPERATION.
Condition: Unknown
Due 25 March 1993
Resolved 25 March 1993
Electrical
Issued 27 April 1992
Resolved
PROVIDE NEW BATTERY BOX'S FOR AFT 2 MOST BATTERIES
Condition: Unknown
Due 4 June 1992
Resolved 4 May 1992
Navigation
Issued 27 April 1992
Resolved
DOUBLE NUT TILLER TO STEERING RAM CONNECTION
Condition: Unknown
Due 4 June 1992
Resolved 4 May 1992
Electrical
Issued 27 April 1992
Resolved
INSTALL NEW GROUNDING STRAP (BONDING SYSTEM) THOUGH OUT VSL
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Documentation
Issued 27 April 1992
Resolved
PROVIDE COAST PILOT
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Lifesaving
Issued 27 April 1992
Resolved
FIX OR REMOVE P.A. SYSTEM
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Electrical
Issued 27 April 1992
Resolved
PROVIDE SUFFICIENT EMERGENCY LIGHTING
Condition: Unknown
Due 4 June 1992
Resolved 4 May 1992
Electrical
Issued 27 April 1992
Resolved
SUBMIT WIRING DIAGRAM OF ELECTRICAL SYSTEM TO OVERHAUL ENTIRE SYSTEM, AND REMOVE ALL UN-NECESSARY WIRING.
Condition: Unknown
Due 4 June 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 27 April 1992
Resolved
FIX MAIN ENGINE TACHOMETER
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Engineering
Issued 27 April 1992
Resolved
STENCILE EMERGENCY FUEL SHUT OFF
Condition: Unknown
Due 4 June 1992
Resolved 4 May 1992
Engineering
Issued 30 April 1991
Resolved
FIX AND MAKE OPERATIONAL ENGINE TACHOMETER
Condition: Unknown
Due 30 April 1991
Resolved 30 April 1991
Fire Fighting
Issued 30 April 1991
Resolved
PROVIDE PROPER BRACKETS FOR PORTABLE FIRE EXTINGUISHERS
Condition: Unknown
Due 30 April 1991
Resolved 30 April 1991
Navigation
Issued 30 April 1991
Resolved
REPOSITION BOLT CONNECTING HYDRAULIC STEERING RAM TO TILLER SO NUT IS ON THE BOTTOM.
Condition: Unknown
Due 30 April 1991
Resolved 30 April 1991
Navigation
Issued 30 April 1991
Resolved
PROVIDE UPDATED CHART OF OPERATING AREA
Condition: Unknown
Due 30 April 1991
Resolved 30 April 1991
Electrical
Issued 30 April 1991
Resolved
REMOVE ALL UNUSED ELECTRIC WIRING AND FIXTURES
Condition: Unknown
Due 30 April 1991
Resolved 30 April 1991
Lifesaving
Issued 30 April 1991
Resolved
PROVIDE RING LIFE BUOY OF APPROPRIATE SIZE
Condition: Unknown
Due 30 April 1991
Resolved 30 April 1991
Unknown
Issued 14 April 1988
Resolved
FREE UP ALL SCUPPERS (NEW PAINT).
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Engineering
Issued 14 April 1988
Resolved
REMOVE FLEXIBLE ADAPTERS BETWEEN PORT AND STARBOARD BILGE LINES AND THROUGHHULL FITTINGS, AND DOUBLE CLAMP THE CONNECTORS.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Engineering
Issued 29 March 1988
Resolved
REMOVE FLEXIBLE ADAPTERS BETWEEN PORT AND STARBOARD BILGE LINES AND THROUGHHULL FITTINGS AND DOUBLE CLAMP THE CONNECTIONS.
Condition: Unknown
Due 29 March 1988
Resolved 29 March 1988
Unknown
Issued 29 March 1988
Resolved
FREE-UP ALL SCUPPERS (NEW PAINT).
Condition: Unknown
Due 29 March 1988
Resolved 29 March 1988
Navigation
Issued 29 March 1988
Resolved
PROVIDE COAST PILOT OR COPY OF RELEVANT PORTION FOR CHESAPEAKE BAY.
Condition: Unknown
Due 29 March 1988
Resolved 29 March 1988
Unknown
Issued 15 April 1987
Resolved
PROPERLY CAP 5 UNUSED OVERBOARD DISCHARGES (2 OLD WASH BASINS, 2 IN AFT STEERING COMPARTMENT, 1 IN NR 2 COMPARTMENT)
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Unknown
Issued 15 April 1987
Resolved
PROPERLY SECURE HYDRAULIC LINES TO STEERING GEAR.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Unknown
Issued 15 April 1987
Resolved
PROVIDE TOOL TO OPERATEE DOGS FOR FOREPEAKD AND NR2 HATCH COVER (T-WRENCH OR TOOL).
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Unknown
Issued 15 April 1987
Resolved
PROVIDE MEANS OF SECURING AFTER DECK HATCHES AND CAPTIVE CHAIN.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Unknown
Issued 15 April 1987
Resolved
PROPERLY MARK PFD LOCKERS AND SEPARATE CHILDREN PFD FROM ADULTS.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Unknown
Issued 15 April 1987
Resolved
RENEW BILGE LINES TO TWO ELECTRIC BILGE PUMPS.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Unknown
Issued 15 April 1987
Resolved
REMOVE EXCESS OIL FROM MACHINERY BILGE. SECURE AUTOMATIC BILGE PUMP.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Unknown
Issued 15 April 1987
Resolved
REPLACE RUBBER HOSE ON PORT AND STBD FUEL TANK VENT LINES WITH APPROVED FUEL LINE.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Unknown
Issued 15 April 1987
Resolved
PROVIDE SHUT-OFF VALVE TO FUEL TANKS SO AS TO BE ACCESSIBLE FROM OUTSIDE TANK SPACE AND ACCESSIBLE FROM WEATHER DECK.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Unknown
Issued 15 April 1987
Resolved
PROPERLY SECURE WIRING CONNECTOR TO FORWARD ALTERNATOR ON DIESEL PROPULSIONMACHINERY.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Unknown
Issued 15 April 1987
Resolved
REMOVE ROMEX ELECTRICAL CABLE FOR EXTERIOR DECK LIGHTING. DECK LIGHTING SHALL BE PERMANENTLY CONNECTED TO VESSEL'S ELECTRICAL SYSTEM IN JUNCTION BOX.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Unknown
Issued 15 April 1987
Resolved
PROVIDE UL APPROVED LIGHT FIXTURE ON DECK OR REMOVE FIXTURE.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Unknown
Issued 15 April 1987
Resolved
REMOVE-RENEW WIRE NUTS USED IN CONNECTING LORAN. USE PRESSURE WIRE CONNECTOR. REMOVE DEAD ELECTRICAL CABLE FROM OLD AUTOPILOT AND DEAD CABLE RUNNING TO FOREPEAK.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Unknown
Issued 15 April 1987
Resolved
PROVIDE OPERATING STERNLIGHT. VESSEL IS LIMITED TO DAYTIME OPERATIONS.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Unknown
Issued 15 April 1987
Resolved
FREE DOGGING DEVICES TO FOREPEAK & NR2 HATCH COVER. ALSO PROVIDE CAPTIVE CHAIN.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987