Records from 2016 to 2026. Most recent: inspection, 18 February 2026.
Documentation record
Registered dimensions (L × B × D)57.0 ft × 17.7 ft × 7.0 ft
Registered tonnagegross 47 / net 37
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGILLMAN MARINE INC · PANAMA CITY FL, UNITED STATES · built 1996
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portDAUPHIN ISLAND, AL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 5 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it47 - Simplified, Gross Ton
37 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 26
18 February 2026
COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8288712
24 February 2025
Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8083877
18 February 2025
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8080661
2 February 2024
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7859914
20 November 2023
Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7827814
9 March 2023
Administrative Inspection · Plan Review "T" Boat
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7648503
23 February 2023
Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7640979
19 January 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7624083
15 August 2022
In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7533891
28 January 2022
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7387409
12 October 2021
Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7330873
12 April 2021
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7173789
22 March 2021
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7160465
3 February 2021
DAPI Audit · Administrative Inspection · Drydock Exam · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7135320
27 February 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6916921
18 September 2019
In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6814734
26 February 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6632940
16 January 2019
Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6611223
17 July 2018
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6482437
26 March 2018
Examination of Repairs · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6378952
2 February 2018
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6348642
20 March 2017
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6123027
1 February 2017
Annual Inspection · Administrative Inspection · DAPI Audit · Hull Examination · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6080901
21 October 2016
Plan Review "T" Boat
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6029654
14 March 2016
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5834009
14 January 2016
Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5797500
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 March 2025
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. Vessel master self reported inoperable audible alarm at operating station for engine room high level alarm.
46 CFR 182.530
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2025
Resolved 24 March 2025
Resolution: Vessel sent video of high level alarm repaired. Uploaded in documents.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 2 February 2024
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Marine Inspector found life float coating to have deteriorated. Repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 March 2024
Resolved 27 February 2024
Resolution: Received photographic evidence of repairs, Sat.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 2 February 2024
Resolved
A vessel must carry adequate and up to date: (1) charts. Marine Inspector was informed by crew that they didn't know the last time their electronic charts were updated. Verify update.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 March 2024
Resolved 27 February 2024
Resolution: Received photographic evidence of updated charts, Sat.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 2 February 2024
Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. Marine Inspector found placard to be missing vessel specific information. Rewrite.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 March 2024
Resolved 27 February 2024
Resolution: Received photographic evidence of properly filled out placard, Sat.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 2 February 2024
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crew members on inspected vessel's Marine Inspector found drug consortium to not have the Captain listed. Update.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 March 2024
Resolved 27 February 2024
Resolution: Received objective evidence of consortium enrollment, Sat.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 23 February 2022
Resolved
Crack on Aft Deck. Repair fiberglass IAW USCG NVIC 08-87
46CFR177.300
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2022
Resolved 7 March 2022
Resolution: Repaired
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 February 2022
Resolved
Hand rail wasted. Contact industry professional to re-weld damaged area.
46CFR177.300
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2022
Resolved 7 March 2022
Resolution: Replaced hand rail
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 February 2022
Resolved
Circuit breaker panel missing breakers. Replace empty spaces.
46CFR183.330
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2022
Resolved 7 March 2022
Resolution: Replaced empty spaces with blanks.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 February 2021
Resolved
Each breaker panel must be protected from hazards. Breaker panel in bridge console had the cover rust off. Replace breaker panel cover.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 March 2021
Resolved 22 February 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 February 2021
Resolved
Independent modular smoke detectors meeting UL 217 are required in each overnight accomodation space. One detector was expired and another is needed in the two man berthing. Rectify prior to carrying overnight passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2021
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 7 March 2018
Resolved
Operator needs proof of DAPI Supervisor Training.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 March 2018
Resolved 26 March 2018
Resolution: DAPI paperwork was provided for all vessel Masters and Deckhands.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 7 March 2018
Resolved
Light batteries are expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 March 2018
Resolved 26 March 2018
Resolution: Life jacket lights were replaced with new batteries.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 7 March 2018
Resolved
STBD side Engine Room ventilation dampers need repaired or replaced.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 March 2018
Resolved 26 March 2018
Resolution: Ventilation louver was adjusted and vessel crew added more foam to allow for a tight e/r seal.
Electrical › Lighting (service) › Outlet Box
Issued 7 March 2018
Resolved
Cover for 110 receptacle in engine room not drip proof.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 March 2018
Resolved 26 March 2018
Resolution: Receptacle cover was replaced with new.
Engineering › Bilge Water Management System › Not Operational
Issued 8 March 2017
Resolved
Bilge pump float switch in lazarette inoperable. Prove proper operation. Conduct hourly round and log until corrected to the satisfaction of attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 20 March 2017
Resolution: Verified that bilge pump switch in lazarette was operable.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 8 March 2017
Resolved
Water light batteries expired. Replace batteries.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 20 March 2017
Resolution: Verified that water light battery was replaced.
Navigation › Piloting/Steering › US Coast Pilot
Issued 8 March 2017
Resolved
No current copy of Coast Pilot on board. Provide current copy.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 20 March 2017
Resolution: Verified that current copy of Coast Pilot was onboard.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 19 February 2016
Resolved
Crewmembers not listed on DAPI letter. Ensure all crewmembers enrolled in company's drug testing program.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 March 2016
Resolved 14 March 2016
Resolution: All crew members were on DAPI letter.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 19 February 2016
Resolved
Both fuel tanks not properly grounded. Ensure tanks properly grounded.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 March 2016
Resolved 14 March 2016
Resolution: Both fuel oil tanks were grounded.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 19 February 2016
Resolved
Flame screen missing from port fuel vent. Ensure proper installation of 30x30 screen.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 March 2016
Resolved 14 March 2016
Resolution: New flame screen installed.
Documentation › Safety Management System › Essential Sailing Instructions Documentation
Issued 19 February 2016
Resolved
Vessel's charts outdated. Ensure charts are current.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 March 2016
Resolved 14 March 2016
Resolution: Purchased new charts.
Documentation › Safety Management System › Emergency Drill/Exercise Programs
Issued 19 February 2016
Resolved
Emergency procedures not posted at operating station. Post emergency procedures at operating station.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 March 2016
Resolved 14 March 2016
Resolution: Emergency procedures posted at operating station.