Documentation record
Registered dimensions (L × B × D)64.8 ft × 19.0 ft × 7.0 ft
Registered tonnagegross 57 / net 46
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderAQUA BAY MARINE INC · PANAMA CITY, FL, UNITED STATES · built 1996
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portMONTAUK, NY
Endorsements, as the file codes themcw_un, fi, rec
DocumentationValid · issued 5 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it57 - Simplified, Gross Ton
46 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 17 inspections, each with its date, unit and type; 13 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 17
4 June 2025
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8151260
4 April 2025
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8104669
17 September 2024
Type not recorded
No type recorded · USCGC RAZORBILL (WPB 87332) · USCG Heartland District (CGD-H) · Activity 8004651
30 May 2024
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7922717
7 June 2023
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7706942
6 April 2023
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7663487
10 March 2022
COI Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7397275
9 September 2021
Simplified Stability Test · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7335054
31 March 2021
Annual Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7166054
16 February 2021
Examination of Repairs · Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7140392
27 March 2020
Internal Structural Exam · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6932391
2 April 2019
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6653886
17 January 2019
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6611830
20 April 2018
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6408773
6 April 2017
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6119313
17 January 2017
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6071672
4 April 2016
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5847218
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 April 2023
Resolved
Fuel tank bonding wire corroded and repaired on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 6 April 2023
Resolved 6 April 2023
Resolution: Corrected on the spot.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 10 March 2022
Resolved
Missing max passengers on upper deck sign.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 April 2022
Resolved 11 March 2022
Resolution: Purchased new sign.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 10 March 2022
Resolved
Bilge high level indicator light in void space #2 not functioning properly.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 April 2022
Resolved 11 March 2022
Resolution: Repaired bulb at operating ststaion.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 10 March 2022
Resolved
EPIRB registration has not yet been completed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 April 2022
Resolved 11 March 2022
Resolution: EPIRB is registered.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 10 March 2022
Resolved
Replace batteries in the lifefloat & lifering lights
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 April 2022
Resolved 11 March 2022
Resolution: Purchased new batteries.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 March 2022
Resolved
Missing alcohol test strips.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 April 2022
Resolved 11 March 2022
Resolution: Purchased new test strips.
Engineering › Bilge Water Management System › Not Operational
Issued 20 April 2018
Resolved
Must prove proper operation of fixed bilge de-watering system
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2018
Resolution: Returned to vessel and owner operated the bilge system from all compartments. (wasted pipe from battery acid was the cause)
Engineering › Bilge Water Management System › Valve
Issued 20 April 2018
Resolved
Each bilge line must be fitted with a check valve.
Action required: 705 - Other - as specified
Due 20 May 2018
Resolved 18 May 2018
Communications › Radio Communications › VHF Radiotelephone
Issued 20 April 2018
Resolved
Vessel must imput the MMSI number into the DSC capable radio
Action required: 705 - Other - as specified
Due 20 May 2018
Resolved 20 April 2018
Resolution: MMSI number imput to radio
Lifesaving › Lifefloat › Retroreflective Material
Issued 6 April 2017
Resolved
Retro-reflective material on all three lifefloats needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 12 April 2017
Resolution: lifefloats all had new, properly attached, retro-reflectiove tape.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 6 April 2017
Resolved
All three lifefloat waterlights are currently attached around the grablines. They need to attached around teh body of the lifefloat.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 12 April 2017
Resolution: completed, all sat.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 6 April 2017
Resolved
No alcohol testing kits were provided onboard.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 12 April 2017
Resolution: recieved, all sat.
Navigation › Piloting/Steering › Marine Charts
Issued 6 April 2017
Resolved
Vessel's charts are not up to date.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 12 April 2017
Resolution: Recieved, all sat.