Inspection record

Last inspected 6 April 2026
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDB6708
Flag
UNITED STATES
Maury page id
psix-44078

Documentation record

Registered dimensions (L × B × D)60.3 ft × 22.8 ft × 6.0 ft
Registered tonnagegross 69 / net 51
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCRUIZON BOAT WORK · SURFSIDE, CA, UNITED STATES · built 1961
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN DIEGO, CA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 7 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it69 - Regulatory (Subpart C or D), Gross Ton
51 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 38 inspections, each with its date, unit and type; 19 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 38

6 April 2026 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8325091
7 January 2026 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8292127
26 March 2025 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8099895
11 March 2025 Plan Review "T" Boat · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8097672
25 October 2024 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8034211
17 October 2024 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8020552
18 August 2024 Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7984844
9 April 2024 In-Service Inspection · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7892653
10 January 2024 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7847636
23 June 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7804028
6 May 2023 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7683695
2 May 2023 Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7681740
6 April 2023 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7684767
30 March 2023 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7659747
30 March 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7660025
28 January 2023 In-Service Inspection · Construction Oversight
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7658761
24 October 2022 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7568248
3 May 2022 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7443257
8 February 2022 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7393012
19 November 2021 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7354143
1 October 2021 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7333581
13 July 2021 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7254096
8 February 2021 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7137666
17 December 2020 Plan Review "T" Boat · Simplified Stability Test · Construction Oversight
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7149745
12 May 2020 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6946878
18 March 2020 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6928966
23 September 2019 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6818782
22 May 2019 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6690687
7 March 2019 Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6637900
24 July 2018 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6489666
2 May 2018 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6403502
8 February 2018 Damage Survey · Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6354079
16 October 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6288917
22 May 2017 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6152371
8 February 2017 Drydock Exam · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6084886
23 July 2016 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6043150
20 July 2016 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5948703
17 May 2016 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5879435

Deficiency record · 19

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 April 2026 Resolved
Bilge piping installed in the engine room is constructed of PVC nonmetallic piping material. Replace piping with approved material. 46CFR182.710.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 April 2026
Resolution: Bilge piping made satisfactory repairs
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 March 2025 Resolved
Machinery spaces must be separated by boundaries that prevent the passage of vapors. The E/R forward bulkhead had several holes leading into the bunk area. Provide a proper seal to prevent the passage of fire suppression system into the bunk room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2025
Resolved 1 April 2025
Resolution: Received photos all engine room bulkhead holes sealed. All SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 August 2024 Resolved
Vessel's starboard MDE is inoperable. Determine cause of engine failure and complete repairs. A satisfactory operational test of the affected engine must be conducted in the presence of a USCG marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 August 2024
Resolution: MI attended vessel to look at new fuel injector. Tested ahead and astern with no issues. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 May 2023 Resolved
STBD engine failed while carrying passengers underway. Make repairs and schedule operational test with CG.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 May 2023
Resolution: Replaced cylinder head, gasket, valves, valve keepers, springs and lifters, and pistons.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 May 2023 Resolved
Knock present on no.1 or 2 cylinder. Replace fuel injectors and check for knock.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 May 2023
Resolution: Replaced fuel injectors.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 May 2023 Resolved
Vessel's starboard MDE failed. Identify and repair cause of failure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2023
Resolution: Completed satisfactory sea trial.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 May 2023 Resolved
STBD MDE became inop during trip w/ passengers. Identify and repair cause of failure prior to sailing.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2023
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 19 November 2021 Resolved
On existing vessels under 65 feet, ducting runs that exit the superstructure in 48 inches or less, can be easily cleaned and inspected without disassembly of the hood casing, bulkheads or adjacent fittings, a fixed fire-fighting system is not required.The owner/operator shall have a procedure in place to clean and inspect the ducting at least quarterly. An additional B-II fire extinguisher and portable smoke detector shall be located in the vicinity of the cooking area. Galley area found to be missing a portable smoke detector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2021
Resolved 29 November 2021
Resolution: Installed smoke detector in galley.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 July 2021 Resolved
A vessel of more than 7.9 meters (26 feet) in length, but not more than 19.8 meters (65 feet), must carry a minimum of one life buoy of not less than 610 millimeters (24 inches) in diameter. Current Life Buoy was 20" in diameter, body showed signs of weathering, cracks on surface, and attaching lines weathered. Recommended Replacement with 24" diameter and provisions.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2021
Resolved 13 July 2021
Resolution: Received Picture of New Life Buoy replacement satisfying Deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 July 2021 Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. Deck water supply pump permanently afixed within machinery space and not hard wired to vessel's electrical system.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2021
Resolved 14 July 2021
Resolution: Received Picture of corrected deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 July 2021 Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. Refer condensate pump lower level bilge area in forward berthing is permanently installed but not hardwired to vessel electrical system.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2021
Resolved 14 July 2021
Resolution: Received Picture of corrected deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 September 2019 Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, and over current protection.
Action required: 705 - Other - as specified
Due 23 December 2019
Resolved 18 March 2020
Resolution: Attended vessel to conduct spot check of A/C electrical one-line drawing, all sat. Drawing was reviewed by Sector San Diego and placed in electronic and permanent files.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 22 May 2019 Resolved
Provide keeper chain on forward hatch.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2019
Resolved 24 June 2019
Resolution: Keeper chain provided.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 22 May 2019 Resolved
Provide either single side band or approved satellite phone in accordance with 47CFR80.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2019
Resolved 24 June 2019
Resolution: SSB operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 May 2019 Resolved
Provide new retro-reflective tape for 10 lifejackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2019
Resolved 24 June 2019
Resolution: New retro placed on 10 lifejackets.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 22 May 2019 Resolved
Provide bulb for pass accomodation space emergency light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2019
Resolved 24 June 2019
Resolution: New emergency light installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 July 2018 Resolved
Provide repair proposal for damge resulting from grounding/reef strike. Make authorized repairs prior to carrying passemgers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 July 2018
Fire Fighting › Remote Fuel Shutoff › General
Issued 2 May 2018 Resolved
Label remote fuel shut-off valves.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2018
Resolved 23 May 2018
Engineering › Diesel Engine (propulsion-direct drive) › Crosshead Assembly
Issued 16 October 2017 Resolved
Replace failed serpintine belt on starboard MDE.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 October 2017

Ownership record