MAURY USCG vessel records Sign in
← All vessels

NEW LO-AN

NEW LO-AN is a 1961 passenger vessel (inspected). The Coast Guard has recorded 113 inspections since 1984, most recently in April 2026, along with 115 deficiencies and 8 casualty investigations between 2005 and 2023.

Records from 1984 to 2026. Most recent: inspection, 6 April 2026.

Built
1961
Last inspected
6 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDB6708
Flag
UNITED STATES
338093000
Maury page id
psix-44078

Inspections, by type

…with no type recorded17
Years with a record 41 calendar years (1984–2026)
The 113 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)60.3 ft × 22.8 ft × 6.0 ft
Registered tonnagegross 69 / net 51
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCRUIZON BOAT WORK · SURFSIDE, CA, UNITED STATES · built 1961
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 7 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it69 - Regulatory (Subpart C or D), Gross Ton
51 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP5272MMSI 338093000 · active · compulsorily equipped · granted 11 April 2024, expires 11 April 2034
WDB6708MMSI 338093000 · expired · compulsorily equipped · granted 1 March 2014, cancelled 4 May 2024
WSC4493MMSI not assigned · expired · compulsorily equipped · granted 3 October 1995, cancelled 18 February 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 113

6 April 2026 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8325091
7 January 2026 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8292127
26 March 2025 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8099895
11 March 2025 Plan Review "T" Boat · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8097672
25 October 2024 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8034211
17 October 2024 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8020552
18 August 2024 Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7984844
9 April 2024 In-Service Inspection · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7892653
10 January 2024 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7847636
23 June 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7804028
6 May 2023 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7683695
2 May 2023 Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7681740
6 April 2023 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7684767
30 March 2023 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7659747
30 March 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7660025
28 January 2023 In-Service Inspection · Construction Oversight
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7658761
24 October 2022 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7568248
3 May 2022 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7443257
8 February 2022 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7393012
19 November 2021 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7354143
1 October 2021 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7333581
13 July 2021 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7254096
8 February 2021 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7137666
17 December 2020 Plan Review "T" Boat · Simplified Stability Test · Construction Oversight
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7149745
12 May 2020 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6946878
18 March 2020 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6928966
23 September 2019 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6818782
22 May 2019 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6690687
7 March 2019 Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6637900
24 July 2018 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6489666
2 May 2018 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6403502
8 February 2018 Damage Survey · Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6354079
16 October 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6288917
22 May 2017 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6152371
8 February 2017 Drydock Exam · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6084886
23 July 2016 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6043150
20 July 2016 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5948703
17 May 2016 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5879435
17 August 2014 Type not recorded
No type recorded · USCGC EDISTO (WPB 1313) · USCG Southwest District (CGD-SW) · Activity 4961997
30 May 2014 DAPI Audit · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4873767
8 June 2012 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4314118
17 July 2011 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4138582
25 March 2010 Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3688779
27 April 2009 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3462490
19 February 2009 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3420219
23 September 2008 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3331220
22 February 2008 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3136635
23 April 2007 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2907455
21 July 2006 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2724356
17 April 2006 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2632229
11 September 2005 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2493525
5 April 2005 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2327254
21 March 2005 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2307696
7 January 2005 Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2255914
1 April 2004 Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2021319
9 April 2003 Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1768299
10 March 2003 Hull Examination · Internal Structural Exam
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1755407
13 May 2002 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1616269
25 March 2002 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1597223
20 March 2002 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1494914
16 October 2001 Damage Survey
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1418990
9 May 2001 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1449466
9 March 2001 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1366367
6 March 2001 Plan Review "T" Boat
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1436620
29 January 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1410478
24 May 2000 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1049727
28 March 2000 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1417046
27 July 1999 Damage Survey
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1450334
25 July 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 153188
3 May 1999 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1432103
12 April 1999 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1420124
5 March 1999 Plan Review "T" Boat
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 801009
30 October 1998 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 803628
17 March 1998 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1408069
13 August 1997 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 16360
3 April 1997 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1378018
17 March 1997 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1392631
23 August 1996 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 81085
29 June 1996 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1245358
25 April 1996 Deficiency Check · Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1371386
7 March 1996 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1363584
11 April 1995 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1424076
8 March 1995 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1412752
9 March 1994 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1435459
27 December 1993 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1428301
25 October 1993 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 960716
9 March 1993 Deficiency Check · Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1362733
11 January 1993 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1137093
13 May 1992 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1270931
18 December 1991 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 957422
9 December 1991 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1254785
13 November 1991 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1252960
1 October 1991 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 938081
6 December 1990 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1227471
30 May 1990 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1228845
11 April 1990 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1232010
15 March 1990 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 920908
30 January 1990 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1228498
18 December 1989 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1243317
13 July 1989 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1195950
15 June 1989 Damage Survey
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 893887
3 February 1989 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 897778
13 January 1989 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1197139
9 December 1988 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1209446
9 December 1987 Hull Examination · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1004713
29 May 1987 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1333239
13 February 1987 Re-Inspection · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1311760
26 November 1986 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1018983
28 January 1986 Re-Inspection · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 996681
30 December 1985 Credit Drydock
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 990875
30 December 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1295522
26 December 1984 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1284765
5 December 1984 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 976925

Deficiency record · 115

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 April 2026 Resolved
Bilge piping installed in the engine room is constructed of PVC nonmetallic piping material. Replace piping with approved material. 46CFR182.710.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 April 2026
Resolution: Bilge piping made satisfactory repairs
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 March 2025 Resolved
Machinery spaces must be separated by boundaries that prevent the passage of vapors. The E/R forward bulkhead had several holes leading into the bunk area. Provide a proper seal to prevent the passage of fire suppression system into the bunk room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2025
Resolved 1 April 2025
Resolution: Received photos all engine room bulkhead holes sealed. All SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 August 2024 Resolved
Vessel's starboard MDE is inoperable. Determine cause of engine failure and complete repairs. A satisfactory operational test of the affected engine must be conducted in the presence of a USCG marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 August 2024
Resolution: MI attended vessel to look at new fuel injector. Tested ahead and astern with no issues. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 May 2023 Resolved
STBD engine failed while carrying passengers underway. Make repairs and schedule operational test with CG.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 May 2023
Resolution: Replaced cylinder head, gasket, valves, valve keepers, springs and lifters, and pistons.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 May 2023 Resolved
Knock present on no.1 or 2 cylinder. Replace fuel injectors and check for knock.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 May 2023
Resolution: Replaced fuel injectors.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 May 2023 Resolved
Vessel's starboard MDE failed. Identify and repair cause of failure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2023
Resolution: Completed satisfactory sea trial.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 May 2023 Resolved
STBD MDE became inop during trip w/ passengers. Identify and repair cause of failure prior to sailing.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2023
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 19 November 2021 Resolved
On existing vessels under 65 feet, ducting runs that exit the superstructure in 48 inches or less, can be easily cleaned and inspected without disassembly of the hood casing, bulkheads or adjacent fittings, a fixed fire-fighting system is not required.The owner/operator shall have a procedure in place to clean and inspect the ducting at least quarterly. An additional B-II fire extinguisher and portable smoke detector shall be located in the vicinity of the cooking area. Galley area found to be missing a portable smoke detector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2021
Resolved 29 November 2021
Resolution: Installed smoke detector in galley.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 July 2021 Resolved
A vessel of more than 7.9 meters (26 feet) in length, but not more than 19.8 meters (65 feet), must carry a minimum of one life buoy of not less than 610 millimeters (24 inches) in diameter. Current Life Buoy was 20" in diameter, body showed signs of weathering, cracks on surface, and attaching lines weathered. Recommended Replacement with 24" diameter and provisions.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2021
Resolved 13 July 2021
Resolution: Received Picture of New Life Buoy replacement satisfying Deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 July 2021 Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. Deck water supply pump permanently afixed within machinery space and not hard wired to vessel's electrical system.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2021
Resolved 14 July 2021
Resolution: Received Picture of corrected deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 July 2021 Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. Refer condensate pump lower level bilge area in forward berthing is permanently installed but not hardwired to vessel electrical system.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2021
Resolved 14 July 2021
Resolution: Received Picture of corrected deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 September 2019 Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, and over current protection.
Action required: 705 - Other - as specified
Due 23 December 2019
Resolved 18 March 2020
Resolution: Attended vessel to conduct spot check of A/C electrical one-line drawing, all sat. Drawing was reviewed by Sector San Diego and placed in electronic and permanent files.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 22 May 2019 Resolved
Provide keeper chain on forward hatch.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2019
Resolved 24 June 2019
Resolution: Keeper chain provided.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 22 May 2019 Resolved
Provide either single side band or approved satellite phone in accordance with 47CFR80.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2019
Resolved 24 June 2019
Resolution: SSB operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 May 2019 Resolved
Provide new retro-reflective tape for 10 lifejackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2019
Resolved 24 June 2019
Resolution: New retro placed on 10 lifejackets.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 22 May 2019 Resolved
Provide bulb for pass accomodation space emergency light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2019
Resolved 24 June 2019
Resolution: New emergency light installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 July 2018 Resolved
Provide repair proposal for damge resulting from grounding/reef strike. Make authorized repairs prior to carrying passemgers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 July 2018
Fire Fighting › Remote Fuel Shutoff › General
Issued 2 May 2018 Resolved
Label remote fuel shut-off valves.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2018
Resolved 23 May 2018
Engineering › Diesel Engine (propulsion-direct drive) › Crosshead Assembly
Issued 16 October 2017 Resolved
Replace failed serpintine belt on starboard MDE.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 October 2017
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 8 June 2012 Resolved
Rejected 01 adult kapok type lifejacket, provide a new one.
Action required: 705 - Other - as specified
Due 30 June 2012
Resolved 12 June 2012
Resolution: New lifejacket on board.
Communications › Alarms/Indicators › General Alarm
Issued 8 June 2012 Resolved
Provide a general alarm or PA speaker in overnight accommodations.
Action required: 705 - Other - as specified
Due 30 June 2012
Resolved 12 June 2012
Resolution: General alarm installed in overnight accommodations.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 8 June 2012 Resolved
Prove proper operation of emergency lighting in overnight accommodations.
Action required: 705 - Other - as specified
Due 30 June 2012
Resolved 12 June 2012
Resolution: Witnessed proper operation of emergency lighting in overnight accommodations.
Communications › Alarms/Indicators › High Water Alarm
Issued 25 March 2010 Resolved
Provide bilge alarm light for lazerette as per 46CFR182.530(a)
Due 8 April 2010
Resolved 26 March 2010
Resolution: Provided new light for lazerette.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 25 March 2010 Resolved
Label emergency escape hatch, " Emergency Exit, Keep Clear", on the outside.
Due 8 April 2010
Resolved 26 March 2010
Resolution: Labeled emergency ecape hatch.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 25 March 2010 Resolved
Provide flame screen on port side fuel tank vent.
Condition: Improper/Lack of Maintenance
Due 8 April 2010
Resolved 26 March 2010
Resolution: Installed new flame screen on port fuel tank vent.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 March 2010 Resolved
Replace guard on port engine vibration dampner.
Due 8 April 2010
Resolved 26 March 2010
Resolution: Provided and installed guard over port engine vibration dampner.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 17 March 2010 Resolved
Provide cover for electrical recepticle in aft engine room.
Condition: Improper/Lack of Maintenance
Due 8 April 2010
Resolved 26 March 2010
Resolution: Provided recepticle cover.
Engineering › Fuel Oil Service System › Hose
Issued 17 March 2010 Resolved
Provide chafing gear for hose running on top of fuel tank.
Due 8 April 2010
Resolved 26 March 2010
Resolution: Installed chafing gear on hose.
Lifesaving › Lifebuoys › Serviceable
Issued 17 March 2010 Resolved
Provide new lifering as per 46CFR180.70
Due 8 April 2010
Resolved 26 March 2010
Resolution: Installed new lifering.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 March 2010 Resolved
Repair of provide new lifering water light.
Condition: Improper/Lack of Maintenance
Due 8 April 2010
Resolved 26 March 2010
Resolution: Provided new waterlight.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 17 March 2010 Resolved
Provide additional 11 lifejackets, for the 11 that failed, as per COI
Due 8 April 2010
Resolved 26 March 2010
Resolution: Placed 11 new lifejackets on board.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 17 March 2010 Resolved
Re-new hose on MSD overboard.
Due 8 April 2010
Resolved 26 March 2010
Resolution: Installed new hose.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 27 April 2009 Resolved
Renew Alcohol swabs
Action required: 705 - Other - as specified
Resolved 22 May 2009
Resolution: Alcohol swabs were renewed
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 27 April 2009 Resolved
Repalce 6 childern and 2 Adults life jackets
Action required: 705 - Other - as specified
Resolved 22 May 2009
Resolution: 6 childern and 2 Adults life jackets were renewed
Construction/Loadline › Penetrations › Valve Flange
Issued 19 February 2009 Resolved
Install new valve for sink drain in the fwd peak compartment
Action required: 705 - Other - as specified
Resolved 14 April 2009
Resolution: New valve for sink drain in the fwd peak compartment was Installed
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 22 February 2008 Resolved
Vsl is restricted to 100 N-miles from shore until DSC side band is installed
Action required: 705 - Other - as specified
Resolved 22 May 2009
Resolution: Corrected
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 23 April 2007 Resolved
Provides a copy of certificate of documentation.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 April 2007
Fire Fighting › Grease Extraction Hood › General
Issued 23 April 2007 Resolved
Complies with requirement or ask for exemption for galley exhaust system as described in CID policy #20.
Condition: Improper Installation
Due 15 May 2007
Resolved 24 April 2007
Navigation › Electronic Positioning › GPS/DGPS Receiver
Issued 23 April 2007 Resolved
Provide a NAVTEX or vessel will be restricted to no maore than 100 miles from shore.
Condition: Improper Installation
Due 20 May 2007
Resolved 28 August 2007
Resolution: Installed new Navtex.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 17 April 2006 Resolved
Change lettering to reflect the proper number of adult lifejackets (55 vice 70)
Condition: Placed in Improper Service
Due 1 May 2006
Resolved 17 May 2006
Personnel › Certificates/Documents/Licenses › License, Master
Issued 17 April 2006 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 1 May 2006
Resolved 21 April 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 April 2006 Resolved
Repair mast and stern lights.
Condition: Improper/Lack of Maintenance
Due 1 May 2006
Resolved 18 April 2006
Navigation › Piloting/Steering › Notices to Navigation
Issued 17 April 2006 Resolved
Update all navigation items: Chart, Coast pilot, Light list, Tidal current table.
Condition: Improper/Lack of Maintenance
Due 1 May 2006
Resolved 21 April 2006
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 17 April 2006 Resolved
Log all required tests of lifesaving equipment.
Condition: Placed in Improper Service
Due 1 May 2006
Resolved 21 April 2006
Engineering › Lubricating Oil Service System › Piping
Issued 17 April 2006 Resolved
Make watertight thru-hull penetrations of hydraulic line in engine room.
Condition: Improper Installation
Due 1 May 2006
Resolved 18 April 2006
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 21 March 2005 Resolved
Nylon lanyard on the portside mounted, lifering waterlight needs to be replaced due to deterioration.
Due 1 April 2005
Resolved 25 March 2005
Resolution: Replaced with new nylon lanyard.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 21 March 2005 Resolved
Outdated. Needs to update or replace w/new pub.
Due 1 April 2005
Resolved 25 March 2005
Resolution: Purchased new (2005) light list pub.
Navigation › Piloting/Steering › Marine Charts
Issued 21 March 2005 Resolved
Charts outdated. New/updated charts required.
Due 1 April 2005
Resolved 25 March 2005
Resolution: Purchased new charts.
Navigation › Piloting/Steering › US Coast Pilot
Issued 21 March 2005 Resolved
Outdated. New/updated pub required.
Due 1 April 2005
Resolved 25 March 2005
Resolution: Purchased new Coast Pilot.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 21 March 2005 Resolved
Tide table book outdated. New/updated book required.
Due 1 April 2005
Resolved 25 March 2005
Resolution: Purchased new tide book.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 March 2005 Resolved
First Aid Kit needs to be updated. Some of the meds are past their expiration dates.
Due 1 April 2005
Resolved 25 March 2005
Resolution: Purchased new first aid kit.
Electrical › Lighting (service)
Issued 9 April 2003 Resolved
Provide cages for lights in enginerom IAW 46 CFR 18.410(a). LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 9 May 2003
Resolved 5 May 2003
Electrical › Electrical Distribution System (service)
Issued 9 April 2003 Resolved
Install wire supports every 24 inches in engineroom IAW 46 CFR 183.340(b)(4). LEGACY COMPONENT DESC: Cable
Action required: 705 - Other - as specified
Due 9 May 2003
Resolved 5 May 2003
Fire Fighting › Ventilation Systems
Issued 20 March 2002 Resolved
Provide mechanical closures for engineroom supply ventillation. LEGACY COMPONENT DESC: Fans
Condition: Design Flaw
Due 1 April 2002
Resolved 13 May 2002
Lifesaving
Issued 9 May 2001 Resolved
Repair or replace painter for Life Floats prior to getting underway.
Condition: Unknown
Due 14 May 2001
Resolved 14 May 2001
Lifesaving
Issued 9 May 2001 Resolved
Make anchor ready for use.
Condition: Unknown
Due 14 May 2001
Resolved 14 May 2001
Lifesaving
Issued 9 May 2001 Resolved
Replace expired First Aid Kit supplies.
Condition: Unknown
Due 14 May 2001
Resolved 14 May 2001
Lifesaving
Issued 9 May 2001 Resolved
Repair or replace Life Ring and install clip for light.
Condition: Unknown
Due 14 May 2001
Resolved 14 May 2001
Lifesaving
Issued 9 May 2001 Resolved
Arrange life lines/grap lines to Life Floats.
Condition: Unknown
Due 14 May 2001
Resolved 14 May 2001
Documentation
Issued 9 May 2001 Resolved
Provide updated Coast Pilot.
Condition: Unknown
Due 14 May 2001
Resolved 14 May 2001
Lifesaving
Issued 9 May 2001 Resolved
Provide emergency Broadcast Placard.
Condition: Unknown
Due 14 May 2001
Resolved 14 May 2001
Lifesaving
Issued 9 May 2001 Resolved
Paint one life float.
Condition: Unknown
Due 14 May 2001
Resolved 14 May 2001
Lifesaving
Issued 9 May 2001 Resolved
Provide Red Cross/CPR cards for 50% of crew.
Condition: Unknown
Due 14 May 2001
Resolved 14 May 2001
Construction/Loadline
Issued 29 January 2001 Resolved
Provide metallic valves and penetrations for PVC piping systems traversing watertight bulkheads.
Condition: Unknown
Due 2 February 2002
Resolved 20 March 2002
Lifesaving
Issued 29 January 2001 Resolved
p
Condition: Unknown
Due 9 February 2001
Resolved 9 February 2001
Electrical
Issued 28 March 2000 Resolved
Replace missing breaker in electrical panel on aft E/R bulkhead
Condition: Unknown
Due 11 April 2000
Resolved 11 April 2000
Engineering
Issued 28 March 2000 Resolved
Install steel bowl on glass fuel filter bowl.
Condition: Unknown
Due 11 April 2000
Resolved 11 April 2000
Lifesaving
Issued 28 March 2000 Resolved
Replace water light on 10 man life float.
Condition: Unknown
Due 11 April 2000
Resolved 11 April 2000
Lifesaving
Issued 28 March 2000 Resolved
Stencil name of vessel on paddles on 10 man life float.
Condition: Unknown
Due 11 April 2000
Resolved 11 April 2000
Lifesaving
Issued 28 March 2000 Resolved
Perform underway drills.
Condition: Unknown
Due 28 March 2000
Resolved 28 March 2000
Navigation
Issued 28 March 2000 Resolved
Double nut steering linkages.
Condition: Unknown
Due 28 March 2000
Resolved 28 March 2000
Lifesaving
Issued 28 March 2000 Resolved
Renew hydro release for EPIRB.
Condition: Unknown
Due 11 April 2000
Resolved 11 April 2000
Fire Fighting
Issued 28 March 2000 Resolved
Prove proper operation of fixed fire fighting system.
Condition: Unknown
Due 11 April 2000
Resolved 11 April 2000
Construction/Loadline
Issued 27 July 1999 Resolved
Perform repairs to STBD side of Hull as outlined in Repair Proposal prior to operating with passengers.
Condition: Unknown
Due 29 July 1999
Resolved 18 August 1999
Documentation
Issued 27 July 1999 Resolved
Submit Form 2692 to [name withheld].
Condition: Unknown
Due 29 July 1999
Resolved 18 August 1999
Construction/Loadline
Issued 27 July 1999 Resolved
Seal Collision Bulkhead.
Condition: Unknown
Due 29 July 1999
Resolved 18 August 1999
Documentation
Issued 3 May 1999 Resolved
Provide updated crew list for drug testing program.
Condition: Unknown
Due 18 May 1999
Resolved 13 May 1999
Lifesaving
Issued 3 May 1999 Resolved
Replace pendant on vessels ring buoy.
Condition: Unknown
Due 18 May 1999
Resolved 13 May 1999
Lifesaving
Issued 3 May 1999 Resolved
Replace two cork lifejackets with proper approved lifejackets.
Condition: Unknown
Due 18 May 1999
Resolved 13 May 1999
Fire Fighting
Issued 3 May 1999 Resolved
Provide 3 smoke detectors (port, stbd, fwd) in crew bunk space and passenger space.
Condition: Unknown
Due 18 May 1999
Resolved 13 May 1999
Lifesaving
Issued 3 May 1999 Resolved
Provide proper label for child lifejacket bin.
Condition: Unknown
Due 18 May 1999
Resolved 13 May 1999
Lifesaving
Issued 17 March 1998 Resolved
RENEW FIVE ADULT LIFE JACKETS.
Condition: Unknown
Due 20 March 1998
Resolved 14 April 1998
Documentation
Issued 17 March 1998 Resolved
PROVIDE LOG BOOK FOR DRILLS, TRAINING, AND EPIRB TESTS.
Condition: Unknown
Due 20 March 1998
Resolved 17 March 1998
Navigation
Issued 25 April 1996 Resolved
demonstrate proper operation of anchor light
Condition: Unknown
Due 1 May 1996
Resolved 2 May 1996
Navigation
Issued 25 April 1996 Resolved
provide .6 meter day shape for anchor ball.
Condition: Unknown
Due 1 May 1996
Resolved 2 May 1996
Navigation
Issued 25 April 1996 Resolved
provide copy of NAVIGATION rules
Condition: Unknown
Due 1 May 1996
Resolved 2 May 1996
Lifesaving
Issued 25 April 1996 Resolved
provide 5 adult PFD's with electric lights
Condition: Unknown
Due 25 April 1996
Resolved 25 April 1996
Lifesaving
Issued 25 April 1996 Resolved
provide proper size weak link for float free attachment,> 21 person capacity.
Condition: Unknown
Due 1 May 1996
Resolved 2 May 1996
Lifesaving
Issued 25 April 1996 Resolved
reattach 10 person life float to float free apparatus
Condition: Unknown
Due 1 May 1996
Resolved 2 May 1996
Lifesaving
Issued 9 March 1993 Resolved
REPAIR/REPLACE RINGBOUY.
Condition: Unknown
Due 21 March 1993
Resolved 21 March 1993
Engineering
Issued 9 March 1993 Resolved
PROVE PROPER OPERATION OF MDE GAUGES.
Condition: Unknown
Due 21 March 1993
Resolved 21 March 1993
Lifesaving
Issued 9 March 1993 Resolved
REPAIR 15 MAN LIFEFLOAT, STENCILE W/ VESSELS NAME, & PLACE RETRO TAPE AS NECESSARY.
Condition: Unknown
Due 21 March 1993
Resolved 21 March 1993
Lifesaving
Issued 9 March 1993 Resolved
REPAIR/REPLACE 12 ADULT PFD'S, VESSEL LIMITED TO 58 TOTAL PERSONS.
Condition: Unknown
Due 21 March 1993
Resolved 21 March 1993
Navigation
Issued 18 December 1991 Resolved
PROVIDE ALL REQUIRED RADIO EQUIPMENT OUTLINED IN 47 CFR 80.905(a)(3) OR OBTAIN EXEMPTION FROM FCC. VESSEL IS LIMITED TO NOT MORE THAN 100 MILES OFFSHORE UNTIL THIS ITEM IS CORRECTED.
Condition: Unknown
Due 18 December 1991
Resolved 18 December 1991
Navigation
Issued 15 March 1990 Resolved
PROVIDE AN OPERATIONAL SINGLE SIDE BAND RADIO. VESSEL IS LIMITED TO ZONE 1AROUTE, BETWEEN POINT CONCEPTION, CA AND LAT. 30 DEGREES 45 MIN. NORTH, NOT MORE THAN 60 MILES OFF A BASELINE EXTENDING FROM POINT CONCEPTION TO CAPE SAN LUCAS, BAJA CALIFORNIA, MEXICO, UNTIL THIS ITEM IS CORRECTED.
Condition: Unknown
Due 15 March 1990
Resolved 15 March 1990
Engineering
Issued 15 March 1990 Resolved
PROVIDE DOUBLE CLAMPS TO RUBBER FLEX HOSES TO THE SEA VALVES IN THE ENGINE ROOM.
Condition: Unknown
Due 15 March 1990
Resolved 15 March 1990
Engineering
Issued 15 March 1990 Resolved
PROVIDE PROPER SAFETY GUARD TO THE PORT AND STBD. ROTATING SHAFTS IN THE ENGINE ROOM.
Condition: Unknown
Due 15 March 1990
Resolved 15 March 1990
Electrical
Issued 15 March 1990 Resolved
PROPERLY SECURE THE LIGHT FIXTURE IN THE AFT LAZARETTE.
Condition: Unknown
Due 15 March 1990
Resolved 15 March 1990
Engineering
Issued 18 December 1989 Resolved
INSTALL FLAME SHIELD ON STARBOARD FUEL FILTER.
Condition: Unknown
Due 18 December 1989
Resolved 18 December 1989
Engineering
Issued 18 December 1989 Resolved
REPLACE PVC PIPING IN BILGE SYSTEM WITH METALLIC PIPING.
Condition: Unknown
Due 18 December 1989
Resolved 18 December 1989
Construction/Loadline
Issued 15 June 1989 Resolved
REPAIR AS ORIGINAL DAMAGED PORT STERN CORNER DECK AND MOORING CLEAT.
Condition: Unknown
Due 15 June 1989
Resolved 15 June 1989
Engineering
Issued 9 December 1988 Resolved
REPAIR STARBOARD PROPULSION ENGINE TACHOMETER.
Condition: Unknown
Due 9 December 1988
Resolved 9 December 1988
Engineering
Issued 13 February 1987 Resolved
REMOVE PETCOCK AND PROVIDE FLAME BOELS ON DAHL FUEL FILTERS.
Condition: Unknown
Due 13 February 1987
Resolved 13 February 1987
Electrical
Issued 13 February 1987 Resolved
PROVIDE ROTATING MACHINERY GUARD FOR GENERATOR ENGINE.
Condition: Unknown
Due 13 February 1987
Resolved 13 February 1987
Accommodation/Occupational Safety
Issued 13 February 1987 Resolved
PROVIDE PROPER SIZED VENT TO ENGINEROOM BILGE AREA.
Condition: Unknown
Due 13 February 1987
Resolved 13 February 1987
Navigation
Issued 13 February 1987 Resolved
PROVIDE COMPASS DEVIATION CARD.
Condition: Unknown
Due 13 February 1987
Resolved 13 February 1987
Lifesaving
Issued 13 February 1987 Resolved
RIG LIFEFLOATS FOR PROPER FLOAT FREE OPERATION
Condition: Unknown
Due 13 February 1987
Resolved 13 February 1987
Navigation
Issued 13 February 1987 Resolved
PROVIDE UP TO DATE TIDE TABLES,CURRENT TABLES AND LIGHT LIST
Condition: Unknown
Due 13 February 1987
Resolved 13 February 1987
Engineering
Issued 13 February 1987 Resolved
REATTACH FLAME SCREEN ON PORT FUEL OIL TANK VENT.
Condition: Unknown
Due 13 February 1987
Resolved 13 February 1987
Lifesaving
Issued 13 February 1987 Resolved
PRESENT 10 MAN LIFEFLOAT FOR INSPECTION.
Condition: Unknown
Due 13 February 1987
Resolved 13 February 1987
Deck/Cargo
Issued 13 February 1987 Resolved
RENEW ALL PLASTIC BILGE LINES IN BILGE SYSTEM WITH APPROVED METALLIC MATERIAL.
Condition: Unknown
Due 13 February 1987
Resolved 13 February 1987
Lifesaving
Issued 28 January 1986 Resolved
PROVIDE 7 CG APPROVED ADULT PFD
Condition: Unknown
Due 28 January 1986
Resolved 28 January 1986
Lifesaving
Issued 28 January 1986 Resolved
PROVE PROPER OPERATION OF EPIRB
Condition: Unknown
Due 28 January 1986
Resolved 28 January 1986
Deck/Cargo
Issued 28 January 1986 Resolved
PROVE PROPER OPERATION OF ANCJHOR WINDLASS
Condition: Unknown
Due 28 January 1986
Resolved 28 January 1986
Electrical
Issued 28 January 1986 Resolved
PROVE PROPER OPERATION OF ELECTRIC WASHDOWN PUMP
Condition: Unknown
Due 28 January 1986
Resolved 28 January 1986

Casualty record · 8

11 September 2005Routine · role: Involved in a Marine Casualty · 1 injured · activity 2493525
21 July 2006Routine · role: Involved in a Marine Casualty · 1 injured · activity 2724356
17 July 2011Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4138582
6 September 2012Routine · role: Involved in a Marine Casualty · activity 4476705
20 July 2016Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 5948703
23 July 2016Routine · role: Involved in a Marine Casualty · 1 injured · activity 6043150
1 October 2021Routine · role: Involved in a Marine Casualty · 1 injured · activity 7333581
6 April 2023Routine · role: Involved in a Marine Casualty · 1 injured · activity 7684767
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record