MAURY USCG vessel records Sign in
← All vessels

BLUE HORIZON

BLUE HORIZON is a 1961 passenger vessel (inspected). The Coast Guard has recorded 47 inspections since 1985, most recently in February 2002, along with 115 deficiencies.

Records from 1985 to 2002. Most recent: inspection, 26 February 2002.

Built
1961
Last inspected
26 February 2002
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WS3255
Flag
UNITED STATES
—
Maury page id
psix-44084

Inspections, by type

…with no type recorded8
Years with a record 15 calendar years (1985–2002)
The 47 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it51 - Regulatory (Subpart C or D), Gross Ton
34 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WS3255MMSI not assigned · expired · compulsorily equipped · granted 10 January 1997, cancelled 3 June 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ANNE B Commercial Fishing Vessel · MISLE 64053 · 20 August 1995 · activity 26875

Inspection history · 47

26 February 2002 Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1489581
25 October 1999 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 793542
22 September 1999 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1032027
13 July 1999 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1096287
8 September 1998 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 802605
22 July 1998 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1130580
23 April 1998 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 789839
31 March 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 787875
10 February 1998 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 774980
24 October 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 4783
14 August 1997 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 785309
2 July 1997 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1364226
9 April 1997 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1092057
18 March 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1096658
6 March 1997 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1096727
27 January 1997 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1102806
6 November 1996 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1171612
3 October 1996 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1149574
24 September 1996 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1398536
3 April 1996 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1079711
20 August 1995 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 26875
15 June 1995 Re-Inspection · Deficiency Check · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1190112
9 September 1994 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1177000
23 June 1994 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1331619
9 May 1994 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1168963
7 September 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1141079
16 August 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1153348
8 July 1993 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 844243
10 June 1993 Hull Examination · Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 839017
14 September 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1260818
16 July 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 940621
14 July 1992 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1466820
26 January 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 212915
26 June 1991 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1228104
19 June 1991 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1202274
17 May 1991 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 908364
16 May 1991 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 907892
6 February 1991 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1214651
29 November 1990 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 900749
23 October 1990 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1233395
2 October 1989 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1039641
1 June 1989 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 890207
6 May 1988 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1043880
6 May 1987 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1324866
15 April 1987 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1022237
17 April 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1291559
14 March 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 978701

Deficiency record · 115

Documentation
Issued 22 September 1999 Resolved
PRIOR TO CARRIAGE OF PASSENGERS FOR HIRE, VESSEL MUST UNDERGO A SATISFACTORY DRYDOCK INSPECTION TO THE SATISFACTION OF THE ATTENDING MARINEINSPECTOR.
Condition: Unknown
Due 22 September 1999
Resolved 25 October 1999
Resolution: Vessel COI de-activated.
Construction/Loadline
Issued 22 July 1998 Resolved
MAKE ENGINE ROOM ACCESS COVER VENTILATION LOUVRES WATERTIGHT, AND ACCESS HATCH TO AFT FUEL TANK SPACE WEATHERTIGHT JUST ABOVE FUEL VENT FLAME SCREENS.
Condition: Unknown
Due 22 July 1998
Resolved 22 July 1998
Engineering
Issued 22 July 1998 Resolved
CORRECT/REPAIR OIL BURNING FROM PORT SIDE ENGINE EXHAUST (AT CONNECTION TO ENGINE).
Condition: Unknown
Due 22 July 1998
Resolved 22 July 1998
Navigation
Issued 22 July 1998 Resolved
RELOCATE STERN LIGHT MORE AFT AS REASONABLY PRACTICABLE, AND TO A REASONABLE HEIGHT, FREE FROM OBSTRUCTION.
Condition: Unknown
Due 22 July 1998
Resolved 22 July 1998
Engineering
Issued 31 March 1998 Resolved
PROVE PROPER OPERATION OF NEW ENGINE PRIOR TO THE CARRAIGE OF PASSENGERS.
Condition: Unknown
Due 31 March 1998
Resolved 31 March 1998
Construction/Loadline
Issued 2 July 1997 Resolved
MAKE BILGE SUCTION VALVE IN FOREPEAK OPERABLE FROM WEATHER DECK OR INSTALL SCREW DOWN VALVE ON BILGE PIPING AFT OF COLLISION BULKHEAD.
Condition: Unknown
Due 2 July 1997
Resolved 2 July 1997
Navigation
Issued 2 July 1997 Resolved
PRVIDE SHIP'S DEVIATION CARD FOR MAGNETIC COMPASS OR HAVE SHIP SWUNG TO GENERATE NEW DEVIATION CARD.
Condition: Unknown
Due 2 July 1997
Resolved 2 July 1997
Lifesaving
Issued 2 July 1997 Resolved
POST LIFEJACKET DONNING PLACARD.
Condition: Unknown
Due 2 July 1997
Resolved 2 July 1997
Construction/Loadline
Issued 2 July 1997 Resolved
HAVE HULL GAUGED AT NEXT DRYDOCK.
Condition: Unknown
Due 2 July 1997
Resolved 2 July 1997
Electrical
Issued 18 March 1997 Resolved
PROPERLY LINE BATTERY BOX INTERIOR IN MSD SPACE TO PREVENT ACID CORROSION OF WOOD BOX.
Condition: Unknown
Due 18 March 1997
Resolved 18 March 1997
Construction/Loadline
Issued 18 March 1997 Resolved
REPAIR SMALL HOLE IN STARBOARD SIDE OF COLLISION BULKHEAD NEAR SIDESHELL.
Condition: Unknown
Due 18 March 1997
Resolved 18 March 1997
Engineering
Issued 6 March 1997 Resolved
RENEW THE PORT AND STARBOARD ENGINE EXHAUST PIPE LAGGING.
Condition: Unknown
Due 7 March 1997
Resolved 7 March 1997
Construction/Loadline
Issued 6 November 1996 Resolved
REMOVE AND TREAT FURRING ON OVERHEAD IN ENGINEROOM.
Condition: Unknown
Due 6 November 1996
Resolved 6 November 1996
Construction/Loadline
Issued 6 November 1996 Resolved
CROP AND RENEW TO GOOD STEEL THE 2ND LONGITUDINAL STRINGER ON THE STBD SIDEFORWARD OF THE TRANSVERSE FRAME.
Condition: Unknown
Due 6 November 1996
Resolved 6 November 1996
Construction/Loadline
Issued 3 October 1996 Resolved
CROP AND RENEW TO GOOD STEEL THE FOLLOWING LONGITUDINAL STRINGERS IN THE HOLD CONTAINING THE POTABLE WATER TANKS; 1ST LONG. ON PORT AND STBD SIDE OFKEEL AFT OF THE TRANSVERSE FRAME, 3RD AND 4TH LONG. ON STBD SIDE OF KEEL AFT OF TRANSVERSE FRAME; 2ND LONG. ON STBD SIDE FWD OF TRANSVERSE FRAME.
Condition: Unknown
Due 3 October 1996
Resolved 3 October 1996
Navigation
Issued 24 September 1996 Resolved
PROVE PROPER MOUNTING OF RADAR SWEEP.
Condition: Unknown
Due 24 September 1996
Resolved 24 September 1996
Construction/Loadline
Issued 24 September 1996 Resolved
REMOVE AND TREAT FURRING OF WOOD ON OVERHEAD IN BATTERY COMPARTMENT, POTABLE WATER TANK COMPARTMENT, ENGINEROOM, FUEL TANK COMPARTMENT AND LAZARETTE.
Condition: Unknown
Due 24 September 1996
Resolved 24 September 1996
Lifesaving
Issued 24 September 1996 Resolved
REPAIR HOLES IN LIFEFLOAT.
Condition: Unknown
Due 24 September 1996
Resolved 24 September 1996
Engineering
Issued 24 September 1996 Resolved
PROVIDE DIRECTIONAL CONTROL ARROWS ON EMERGENCY FUEL SHUT-OFFS.
Condition: Unknown
Due 24 September 1996
Resolved 24 September 1996
Electrical
Issued 24 September 1996 Resolved
REPLACE COVER ON LIGHT SWITCH IN POTABLE WATER COMPARTMENT.
Condition: Unknown
Due 24 September 1996
Resolved 24 September 1996
Construction/Loadline
Issued 24 September 1996 Resolved
PROVE PROPER OPERATION OF FOREPEAK ISOLATION VALVE.
Condition: Unknown
Due 24 September 1996
Resolved 24 September 1996
Electrical
Issued 24 September 1996 Resolved
PROPERLY DEAD-END WIRING IN OVERHEAD OF MSD COMPARTMENT.
Condition: Unknown
Due 24 September 1996
Resolved 24 September 1996
Electrical
Issued 24 September 1996 Resolved
PROPERLY HANG WIRING WITH METAL TIES IN MSD SPACE.
Condition: Unknown
Due 24 September 1996
Resolved 24 September 1996
Construction/Loadline
Issued 24 September 1996 Resolved
CROP AND RENEW WASTED LONGITUDINAL FRAMES IN FOREPEAK AND MSD (BATTERY) SPACE.
Condition: Unknown
Due 24 September 1996
Resolved 24 September 1996
Construction/Loadline
Issued 24 September 1996 Resolved
CROP AND RENEW TO GOOD METAL LONGITUDINALS IN POTABLE WATER SPACE. PROVE REPAIR OF SUCH PRIOR TO CARRAIGE OF PASSENGERS.
Condition: Unknown
Due 24 September 1996
Resolved 24 September 1996
Construction/Loadline
Issued 15 June 1995 Resolved
REWELD WORN AREAS OF CHINE (PORT AND STBD)
Condition: Unknown
Due 16 October 1995
Resolved 16 October 1995
Construction/Loadline
Issued 15 June 1995 Resolved
REPLACE LONGITUDINALS UNDER ACCOMIDATION SPACE
Condition: Unknown
Due 16 October 1995
Resolved 16 October 1995
Construction/Loadline
Issued 15 June 1995 Resolved
MAKE THE AFTER LAZARETTE HATCH COMPLY WITH 46 CFR 171.124(a): EACH HATCH EXPOSED TO THE WEATHER MUST BE WATERTIGHT, EXCEPT THE FOLLOWING HATCH MAY BE WEATHERTIGHT - EACH HATCH ON A WATERTIGHT TRUNK THAT EXTENDS AT LEAST 12INCHES ABOVE THE WEATHER DECK.
Condition: Unknown
Due 15 June 1995
Resolved 15 June 1995
Navigation
Issued 15 June 1995 Resolved
REPLACE RUDDER BLADE AS ORIGINAL, EXCESSIVE PITTING OVER ENTIRE BLADE SURFACE
Condition: Unknown
Due 16 October 1995
Resolved 16 October 1995
Lifesaving
Issued 23 June 1994 Resolved
RENEW PAINTER AND NET RETENTION LIN ON AFT L/F.
Condition: Unknown
Due 23 June 1994
Resolved 23 June 1994
Electrical
Issued 23 June 1994 Resolved
PROPERLY DUNNAGE BATTERIES IN BATT. BOXES IWO E/R AND BATT COMPARTMENT.
Condition: Unknown
Due 23 June 1994
Resolved 23 June 1994
Construction/Loadline
Issued 23 June 1994 Resolved
PROPERLY LABLE BILGE MANIFOLD.
Condition: Unknown
Due 23 June 1994
Resolved 23 June 1994
Navigation
Issued 23 June 1994 Resolved
REMOVE OLD FATH (ALREADY DISCONNECTED).
Condition: Unknown
Due 23 June 1994
Resolved 23 June 1994
Lifesaving
Issued 16 August 1993 Resolved
PROVE OPERATION OF LIFERING WATERLIGHT PRIOR TO SAILING.
Condition: Unknown
Due 17 August 1993
Resolved 17 August 1993
Lifesaving
Issued 16 August 1993 Resolved
REPAIR AFTER LIFEFLOAT (SEVERAL HOLES). VSL RESTRICTED TO 48 PASSENGERS UNTIL THIS ITEM IS CLEARED.
Condition: Unknown
Due 16 August 1993
Resolved 16 August 1993
Construction/Loadline
Issued 16 August 1993 Resolved
REPLACE ROTTEN WOOD IN WAY OF PORT ENGINE ROOM HATCH (BOTTOM INBOARD). COMPLETE REPAIRS TO THE SATISFACTION OF THE ATTENDING MARINE COAST GUARD INSPECTOR BY 30 DEC 93.
Condition: Unknown
Due 16 August 1993
Resolved 16 August 1993
Lifesaving
Issued 16 August 1993 Resolved
PROVE OPERATION OF AFT LIFEFLOAT WATERLIGHT. RESTRICTION ON #1 APPLIES.
Condition: Unknown
Due 16 August 1993
Resolved 16 August 1993
Lifesaving
Issued 16 August 1993 Resolved
INSTALL AN 18' LINE ON BOTH LIFEFLOAT WATERLIGHTS.
Condition: Unknown
Due 16 August 1993
Resolved 16 August 1993
Lifesaving
Issued 10 June 1993 Resolved
PROVIDE SEA PAINTER FOR LIFEFLOATS. COMPLETE PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 16 August 1993
Resolved 16 August 1993
Engineering
Issued 10 June 1993 Resolved
INSTALL FLAME GUARDS FOR BOTH EMERGENCY FUEL SHUT OFFS.
Condition: Unknown
Due 10 June 1993
Resolved 10 June 1993
Lifesaving
Issued 10 June 1993 Resolved
AFFIX RETROFLECTIVE TAPE TO RING BUOY.
Condition: Unknown
Due 16 August 1993
Resolved 16 August 1993
Construction/Loadline
Issued 10 June 1993 Resolved
CROP AND RENEW 2 LONGITUDINALS STBD SIDE OF 2 ND VOID AFT OF BOW.
Condition: Unknown
Due 28 June 1993
Resolved 30 June 1993
Documentation
Issued 10 June 1993 Resolved
PROVIDE MASTER'S LICENSE.
Condition: Unknown
Due 9 July 1993
Resolved 9 July 1993
Construction/Loadline
Issued 10 June 1993 Resolved
CROP AND RENEW LONGITUDINAL STBD SIDE OF E.R. TO GOOD METAL.
Condition: Unknown
Due 28 June 1993
Resolved 30 June 1993
Documentation
Issued 10 June 1993 Resolved
POST MARPOL V OIL PLACARD.
Condition: Unknown
Due 16 August 1993
Resolved 16 August 1993
Documentation
Issued 10 June 1993 Resolved
PROVIDE CURRENT MARINE RADIO OPERATOR PERMIT.
Condition: Unknown
Due 9 July 1993
Resolved 9 July 1993
Construction/Loadline
Issued 10 June 1993 Resolved
CLEAN & TREAT FURRING OVER STBD ENGINE.
Condition: Unknown
Due 10 June 1993
Resolved 10 June 1993
Lifesaving
Issued 10 June 1993 Resolved
PROVIDE 1 PADDLE. COMPLETE PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 16 August 1993
Resolved 16 August 1993
Lifesaving
Issued 10 June 1993 Resolved
PROVIDE WEAK LINK FOR LIFEFLOATS. COMPLETE PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 16 August 1993
Resolved 16 August 1993
Fire Fighting
Issued 10 June 1993 Resolved
SERVICE ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 28 June 1993
Resolved 30 June 1993
Construction/Loadline
Issued 16 July 1992 Resolved
PROVE THAT THE HATCH LEADING INTO THE AFTER LAZARETTE COMPLIES WITH 46 CFR 171.124(a) AND (b). COMPLETE DURING NEXT DRYDOCK BUT NO LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 16 July 1992
Resolved 16 July 1992
Electrical
Issued 14 July 1992 Resolved
RELINE FWD BATTERY BOX WITH LEAD OR ANY MATERIAL WHICH IS RESISTANT TO THE CORROSIVE AFFECTS OF THE ELECTROLYTE.
Condition: Unknown
Due 14 July 1992
Resolved 14 July 1992
Construction/Loadline
Issued 14 July 1992 Resolved
PROVIDE 6" COAMING FOR PASSENGER LOUNGE AFT ENTRANCE FROM WX DECK
Condition: Unknown
Due 14 July 1992
Resolved 14 July 1992
Construction/Loadline
Issued 14 July 1992 Resolved
MAKE FORWARD COMPARTMENT HATCH WATERTIGHT AND CONDUCT SATISFACTORY HOSE TEST.
Condition: Unknown
Due 14 July 1992
Resolved 14 July 1992
Construction/Loadline
Issued 14 July 1992 Resolved
CONDUCT SATISFACTORY HOSE TEST OF LAZERETTE HATCH. GASKET WAS TORN AND NOT SEATED PROPERLY.
Condition: Unknown
Due 14 July 1992
Resolved 14 July 1992
Construction/Loadline
Issued 14 July 1992 Resolved
PROVIDE HATCH RETENTION DEVICES FOR ENGINEROOM HATCHES
Condition: Unknown
Due 14 July 1992
Resolved 14 July 1992
Navigation
Issued 14 July 1992 Resolved
CROP AND REPLACE AS ORIGINALLY DESIGNED ALL WASTED METAL ON THE PORT RUDDERQUADRANT
Condition: Unknown
Due 14 July 1992
Resolved 14 July 1992
Navigation
Issued 14 July 1992 Resolved
PROVIDE ANCHOR BALL
Condition: Unknown
Due 14 July 1992
Resolved 14 July 1992
Unknown
Issued 14 July 1992 Resolved
COMPLETE OPERATIONAL TEST OF VSL WITH CREW ON BOARD TO CONDUCT U/W TEST OF STEERING, ENGINES ALSO CONDUCT MAN OVERBOARD DRILL WITH SENIOR DECKHAND AT THE HELM
Condition: Unknown
Due 14 July 1992
Resolved 14 July 1992
Electrical
Issued 14 July 1992 Resolved
PROVIDE PROPER JUNCTION BOX FOR SHORE POWER CONNECTION ON STARBOARD
Condition: Unknown
Due 14 July 1992
Resolved 14 July 1992
Construction/Loadline
Issued 14 July 1992 Resolved
MAKE ENGINEROOM AND FUEL TANK COMPARTMENT ACCESS TRUNKS WATERTIGHT TO 12" ABOVE MAINDECK.
Condition: Unknown
Due 14 July 1992
Resolved 14 July 1992
Electrical
Issued 16 May 1991 Resolved
SECURE ALL LOOSE WIRING.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Engineering
Issued 16 May 1991 Resolved
SECURE PIPING ON PORT ENGINE WATER PUMP.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Construction/Loadline
Issued 16 May 1991 Resolved
REPLACE FLASH GUARD ON PORT FUEL SHUT OFF VALVE.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Construction/Loadline
Issued 16 May 1991 Resolved
PROVIDE CLOSURE DEVICES ON ALL HATCH COVERS.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Construction/Loadline
Issued 16 May 1991 Resolved
REPLACE HATCH COVER TO LAZARETTE.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Navigation
Issued 16 May 1991 Resolved
THREAD, NUT, AND PIN STEERING GEAR AS PER ORIGNAL.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Construction/Loadline
Issued 16 May 1991 Resolved
PROVIDE PROOF OF HULL GUAGING TO COAST GUARD INSPECTOR.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Engineering
Issued 23 October 1990 Resolved
REPLACE FWD COMPT MISSING BILGE SUCTION SCREEN.
Condition: Unknown
Due 23 October 1990
Resolved 23 October 1990
Accommodation/Occupational Safety
Issued 23 October 1990 Resolved
REPAIR OR REMOVE ENGINE COMPT MECHANICAL SUPPLY BLOWER.
Condition: Unknown
Due 23 October 1990
Resolved 23 October 1990
Accommodation/Occupational Safety
Issued 23 October 1990 Resolved
LOWER ENGINE COMPT SUPPLY VENTILLATION AS LOW AS PRACTICABLE TO THE BILGE.
Condition: Unknown
Due 23 October 1990
Resolved 23 October 1990
Engineering
Issued 23 October 1990 Resolved
STENCIL BOTH AFT REMOTE FUEL SHUTDWNS.
Condition: Unknown
Due 23 October 1990
Resolved 23 October 1990
Engineering
Issued 23 October 1990 Resolved
MOUNT SPANNER WRENCH IN IMMEDIATE VICINTIY OF FUEL SHUTDOWNS TO BE USED TO REMOVE BRASS COVERS ON SAID SHUTDOWNS.
Condition: Unknown
Due 23 October 1990
Resolved 23 October 1990
Engineering
Issued 23 October 1990 Resolved
REPLACE FLAMEGUARD ON STBD AFT REMOTE FUEL SHUTDOWN.
Condition: Unknown
Due 23 October 1990
Resolved 23 October 1990
Fire Fighting
Issued 23 October 1990 Resolved
PROVIDE ADEQUATE HOSES FOR HAND BILGE PUMP TO BE USED IN ANY SPACE OR FROM OVBD THE VESSEL.
Condition: Unknown
Due 23 October 1990
Resolved 23 October 1990
Lifesaving
Issued 23 October 1990 Resolved
INSTALL RETRO-REFLECTIVE TAPE ON BOTH 25 MAN LIFEFLOATS AS INSTRUCTED BY CG INSPECTORS.
Condition: Unknown
Due 23 October 1990
Resolved 23 October 1990
Lifesaving
Issued 23 October 1990 Resolved
INSTALL RETRO-REFLECTIVE TAPE ON VSL'S RING BUOY.
Condition: Unknown
Due 23 October 1990
Resolved 23 October 1990
Engineering
Issued 23 October 1990 Resolved
CLEAN OR REPLACE FLAME SCREENS ON ALL FOUR FUEL TANK VENTS.
Condition: Unknown
Due 23 October 1990
Resolved 23 October 1990
Engineering
Issued 23 October 1990 Resolved
REPAIR PROT ENGINE TACHOMETER IN PILOTHOUSE.
Condition: Unknown
Due 23 October 1990
Resolved 23 October 1990
Navigation
Issued 23 October 1990 Resolved
OBTAIN COMPASS DEVIATION CARD AND POST IN WHEELHOUSE.
Condition: Unknown
Due 23 October 1990
Resolved 23 October 1990
Documentation
Issued 23 October 1990 Resolved
PROVIDE AND POST OIL POLLUTION AND MARPOL ANNEX V PLACARDS.
Condition: Unknown
Due 23 October 1990
Resolved 23 October 1990
Accommodation/Occupational Safety
Issued 6 May 1988 Resolved
2 REBAND/STRAP PORT WATER TANK IN PLACE.
Condition: Unknown
Due 6 May 1988
Resolved 6 May 1988
Construction/Loadline
Issued 6 May 1988 Resolved
3 REPLACE GOOSE NECK VENTS TO FWD COMPARTMENT.
Condition: Unknown
Due 6 May 1988
Resolved 6 May 1988
Engineering
Issued 6 May 1988 Resolved
4 REPAIR EMERGENCY FUEL SHUT OFFS AT TANK AND PROVIDE METALIC ENCLOSURE TO REACH RODS.
Condition: Unknown
Due 6 May 1988
Resolved 6 May 1988
Engineering
Issued 6 May 1988 Resolved
5 STENCIL EMERGENCY FUEL SHUTOFFS.
Condition: Unknown
Due 6 May 1988
Resolved 6 May 1988
Unknown
Issued 6 May 1988 Resolved
6 PROVIDE ADDITIONAL HOSE FOR HAND BILGE PUMP TO ENABLE ITS USE IN ANY COMPARTMENT.
Condition: Unknown
Due 6 May 1988
Resolved 6 May 1988
Accommodation/Occupational Safety
Issued 6 May 1988 Resolved
7 PROVIDE GLOBES FOR LIGHTS IN HEADS.
Condition: Unknown
Due 6 May 1988
Resolved 6 May 1988
Construction/Loadline
Issued 6 May 1988 Resolved
8 INSERT LOWER HALF OF COLLISION BULKHEAD.
Condition: Unknown
Due 6 May 1988
Resolved 6 May 1988
Construction/Loadline
Issued 6 May 1988 Resolved
9 INSERT FORWARD AREA OF MAIN DECK AROUND MAN HOLE AND OTHER AREAS ON BOW AS NECESSARY
Condition: Unknown
Due 6 May 1988
Resolved 6 May 1988
Documentation
Issued 6 May 1988 Resolved
1 PROVIDE FCC RADIO SAFETY EQUIP CERTIFICATE.
Condition: Unknown
Due 6 May 1988
Resolved 6 May 1988
Engineering
Issued 6 May 1987 Resolved
REPLACE ALL FOUR (4) FLAME SCREENS STBD SIDE WITH 30X30 MESH SCREENS.
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Engineering
Issued 6 May 1987 Resolved
REPAIR EXHAUST LEAK ON PORT ENGINE FLANGE FITTING.
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Documentation
Issued 6 May 1987 Resolved
PROVIDE RADIO SAFETY CERTIFICATE.
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Navigation
Issued 6 May 1987 Resolved
REPAIR & PROVE OPERATION OF STBD RUNNING LIGHT AND 180 BOW LIGHT.
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Lifesaving
Issued 6 May 1987 Resolved
REPLACE ALL MAN LINES ON AFT BUOYANT APPARATUS & ATTACHMENT LIN BETWEEN THETWO APPARATUSES.
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Fire Fighting
Issued 6 May 1987 Resolved
PROVIDE ONE (1) HAND FIRE/BILGE PUMP MARKED WITH VESSEL'S NAME.
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Accommodation/Occupational Safety
Issued 6 May 1987 Resolved
PROVIDE VENTILATION TO FUEL SPACE AS PER 46 CFR 182.20-50.
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Electrical
Issued 6 May 1987 Resolved
PROVE PROPER OPERATION OF PORT VOLT METER LOCATED ON CONSOLE.
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Construction/Loadline
Issued 6 May 1987 Resolved
PROVIDE 12" COAMING OR WATERTIGHT COVER FOR AFT STEERING.
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Lifesaving
Issued 6 May 1987 Resolved
PROVIDE WATERLIGHT FOR RING BUOY.
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Fire Fighting
Issued 6 May 1987 Resolved
PROVIDE ONE (1) B-II EXTINGUISHER.
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Electrical
Issued 6 May 1987 Resolved
PROVIDE COVER FOR LIGHT FIXTURE MOUNTED IN VOID UNDER PILOT HOUSE.
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Engineering
Issued 6 May 1987 Resolved
REMOUNT EMERGENCY FUEL SHUT-OFF ROD STBD SIDE. PROVIDE HAND PROTECTION COVERS FOR PORT & STBD FUEL SHUT-OFFS.
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Electrical
Issued 6 May 1987 Resolved
REMOVE DETERIORATED BATTERY CHARGER STBD SIDE #1 HOLD.
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Construction/Loadline
Issued 14 March 1985 Resolved
INSTALL TWO STIFFNER PLATES TO LONGS FOREPEAK.
Condition: Unknown
Due 14 March 1985
Resolved 14 March 1985
Navigation
Issued 14 March 1985 Resolved
BLACKEN SCREEN BOTH PORT AND STBD RUNNING LIGHTS.
Condition: Unknown
Due 14 March 1985
Resolved 14 March 1985
Electrical
Issued 14 March 1985 Resolved
INSTALL WOOD BLOCKS IN BATTERY BOXES.
Condition: Unknown
Due 14 March 1985
Resolved 14 March 1985
Unknown
Issued 14 March 1985 Resolved
REPAIR PORT BILGE PUMP OVERBOARD DISCHARGE HOSE THAT IS CRIMPED.
Condition: Unknown
Due 14 March 1985
Resolved 14 March 1985
Unknown
Issued 14 March 1985 Resolved
INSTALL FLAME SCREEN OVER FUEL OIL VENT.
Condition: Unknown
Due 14 March 1985
Resolved 14 March 1985
Construction/Loadline
Issued 14 March 1985 Resolved
DOUBLE HOSE CLAMP ALL THREW HULL HOSE CONNECTIONS.
Condition: Unknown
Due 14 March 1985
Resolved 14 March 1985
Unknown
Issued 14 March 1985 Resolved
PROCURE COAST GUARD APPROVED FUEL OIL HOSE OR INSTALL FLAME SCREEN CLOTH OVER.
Condition: Unknown
Due 14 March 1985
Resolved 14 March 1985
Documentation
Issued 14 March 1985 Resolved
POST STABILITY LETTER.
Condition: Unknown
Due 14 March 1985
Resolved 14 March 1985
Lifesaving
Issued 14 March 1985 Resolved
PROCURE WATERTIGHT CONTAINER FOR SIGNAL FLARES.
Condition: Unknown
Due 14 March 1985
Resolved 14 March 1985
Unknown
Issued 14 March 1985 Resolved
PROCURE RECENT RULES OF THE ROAD.
Condition: Unknown
Due 14 March 1985
Resolved 14 March 1985
Lifesaving
Issued 14 March 1985 Resolved
PROCURE 2 LIFEFLOAT PADDLES WITYH VESSEL'S NAME STENCILED ON ALL PADDLES.
Condition: Unknown
Due 14 March 1985
Resolved 14 March 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.