MAURY USCG vessel records
← All vessels

LIBERTY

Built
1961
Last inspected
15 April 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 April 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDI8652
Flag
UNITED STATES
Maury page id
psix-44103

Documentation record

Registered dimensions (L × B × D)85.0 ft × 23.2 ft × 5.8 ft
Registered tonnagegross 92 / net 62
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDITTMAR AND DONALDSON · COSTA MESA, CA, UNITED STATES · built 1961
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN DIEGO, CA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 5 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it92 - Regulatory (Subpart C or D), Gross Ton
62 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 27 inspections, each with its date, unit and type; 46 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 27

15 April 2026 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8306581
29 June 2025 Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8169449
21 May 2025 Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8142300
21 May 2025 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8276584
29 April 2025 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8127013
20 November 2024 Administrative Inspection · Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7854220
21 March 2024 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7883110
8 August 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7870622
21 March 2023 Administrative Inspection · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7654493
14 December 2022 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7588931
29 March 2022 Annual Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7421674
3 May 2021 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7188119
10 December 2020 Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7109567
27 April 2020 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6946810
11 December 2019 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6872235
10 October 2019 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6834204
12 March 2019 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6641316
26 February 2019 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6634491
3 December 2018 Examination of Repairs · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6572148
11 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6537849
11 July 2018 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6491251
14 March 2018 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6371703
13 December 2017 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6324056
2 May 2017 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6137132
10 November 2016 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6030116
28 April 2016 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5865014
7 February 2016 Plan Review "T" Boat · Deficiency Check · Inclining Experiment · Administrative Inspection · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5827239

Deficiency record · 46

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 29 June 2025 Resolved
Vessel was received damage on the STBD side, bulwark. Vessel is provide a repair plan and upon approval repairs are to be completed, and final inspection shall be done by a CG Marine Inspector, prior to the vessel taking on passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2025
Resolution: Observed final repairs. All SAT
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 May 2025 Resolved
SSD inspectors received a report that the vessel M/V LIBERTY experienced a malfunction and collided with other vessels resulting in reported damage to the vessel and three recreational vessels. Vessel must investigate the cause of the incident, submit their findings and submit repair proposals for damage suffered during the marine casualty as well as equipment repairs. 46cfr176.840
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 May 2025
Resolution: Witnessed satisfactory repairs and seatrials
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 April 2025 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. Forward compartment bilge pumping arrangement was not operational. Provide operational bilge pumping arrangement. 46 CFR 182.500
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 May 2025
Resolution: Bilge system operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 April 2025 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Vessel did not have indicator for automatic bilge pumps. Provide indicator at operating station for automatic bilge pump. 46 CFR 182.500
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2025
Resolved 27 May 2025
Resolution: Witness satisfactory tests
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 August 2023 Resolved
As stated in letter dated 07MAR2024, vessel must comply with Fire Safety of Small Passenger Vessels Interim Final Rule requirements by the next scheduled dry dock or 01JAN2026, whichever comes first. Vessel does not yet meet requirements and is restricted from carrying overnight passengers or allowing passengers in the bunk rooms until modifications are made and egress drills are completed. Cites: National Defense Authorization Act for Fiscal Year 2024 (H.R. 2670), Section 3531(b).
Action required: 705 - Other - as specified
Resolved 11 April 2025
Resolution: Vessel was issued IFR compliance letter following satisfactory drills.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 March 2023 Resolved
Engine room switchboard indicator light covers missing; Install covers.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2023
Resolved 28 April 2023
Resolution: Received picture of corrected deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 March 2023 Resolved
Engine room overhead electrical junction box enclosure cable opening not sealed. Repair.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2023
Resolved 21 March 2023
Resolution: Item corrected.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 March 2023 Resolved
Main deck STBD side fire hose station; hose bursted at its coupling during test. Repair / replace hose.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2023
Resolution: Recieved proof of purchase of a new fire hose.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 21 March 2023 Resolved
Provide plan proposal for installation of stairs in Passenger accommodations to aid in means of Escape. Submit to [email withheld] for review.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 11 April 2025
Resolution: Vessel was issued IFR compliance letter following completion of satisfactory egress drills.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 29 March 2022 Resolved
Provide FCC Marine Radio Operator Permits for all licensed crewmembers. Cite: 47 CFR 80.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2022
Resolved 13 July 2022
Resolution: FCC course/test completed for remining crewmembers.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 3 May 2021 Resolved
Vessel's stbd generator 'raycor' fuel filter was found to be missing the flame impingement bowl. Provide a manufacturer approved replacement bowl for filter.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 1 June 2021
Resolution: Vessel rep provided photo of flame bowl installed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 3 May 2021 Resolved
Provide both accommodation space exit stairs with emergency lighting. Current configuration only has lighting at forward end of compartment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 1 June 2021
Resolution: Vessel rep provided video of new lights installed and working.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 May 2021 Resolved
Remove extension cord and wire laz bilge pump with permanent boat cable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 1 June 2021
Resolution: Vessel rep provided video of new cable installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 May 2021 Resolved
Remove extension cord and provide laz ventilation blower with dedicated receptacle.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 1 June 2021
Resolution: Vessel rep provided photo of wired blowers.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 May 2021 Resolved
04 adult life jackets were found with deteriorated retro reflective tape. Provide identified jackets with SOLAS approved retro tape.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 1 June 2021
Resolution: Vessel rep provided photo of new retro installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 3 May 2021 Resolved
Vessel recently replaced all flush deck hatches with new. Provide captive retaining devices on all hatches.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 1 June 2021
Resolution: Vessel rep provided photos of cables installed on hatches.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 3 May 2021 Resolved
Engine compartment forward bulkhead was found with a open cable penetration. Make port/forward bulkhead vapor/water-tight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 1 June 2021
Resolution: Vessel rep provided photo of sealed bulkhead with fire-stop.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 3 May 2021 Resolved
Live well compressor was found unsecured in engine compartment. Properly mount compressor.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 1 June 2021
Resolution: Vessel rep provided photo of bolted down compressor.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 27 April 2020 Resolved
BLOWER SYSTEM AND BILGE ALARM ELECTRICAL WIRING IS CONNECTED TO A POWER STRIP IN FORWARD GALLEY STORAGE SPACE. BOTH SYSTEMS MUST BE CONNECTED TO OUTLETS HARDWIRED TO THE VESSEL ELECTRICAL DISTRIBUTION SYSTEM. DEFICIENCY WAS CORRECTED ON THE SPOT.
Action required: 10 - Deficiency Rectified
Due 27 April 2020
Resolved 27 April 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 April 2020 Resolved
OPENING WAS FOUND ON PANEL FACE ON THE GALLEY DISTRIBUTION PANEL. MUST INSTALL BLANK FITTING TO COVER OPENING TO THE SATISFACTION OF THE CG MARINE INSPECTOR.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2020
Resolved 6 May 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 April 2020 Resolved
REMOTE FUEL SHUT-OFFS WERE NOT MARKED IN ACCORDANCE WITH THE REGULATIONS. MUST BE MARKED IN CLEARLY LEGIBLE LETTER AT LEAST ONE INCH HIGH INDICATING PURPOSE OF THE VALVE AND DIRECTION OF OPERATION TO SATISFACTION OF CG MARINE INSPECTOR.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2020
Resolved 6 May 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 October 2019 Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps.
Action required: 705 - Other - as specified
Due 10 January 2020
Resolved 13 March 2020
Resolution: Drawing submitted for review
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 March 2019 Resolved
Repair/replace forward life ring.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2019
Resolved 13 March 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 March 2019 Resolved
Replace worn flame impingement bowl.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2019
Resolved 13 March 2019
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 12 March 2019 Resolved
Provide updated navigation charts.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2019
Resolved 13 March 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 March 2019 Resolved
Replace the identified 04 wasted children's lifejackets. Vessel is not to carry more children then it has available children's lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2019
Resolved 13 March 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 February 2019 Resolved
Noted Oil cooler raw water piping leaking on both MDEs; repair or renew piping to the satisfaction of attending CGMI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 March 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 December 2018 Resolved
CONDUCT SEA TRIAL PRIOR TO CARRIAGE OF PASSENGERS. CREDIT DRY DOCK NOT GIVEN UNTIL SEA TRIAL IS COMPLETED TO THE SATISFACTION OF THE ATTENDING USCG MARINE INSPECTOR.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 February 2019
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 11 September 2018 Resolved
MMSI: Vsl is broadcasting MMSI from expired FCC License, CLSN: Vsl is broadcasting Call Sign from expired FCC License,
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 4 December 2018
Resolution: Verified in VIVS
Deck/Cargo › Fishing › General
Issued 2 May 2017 Resolved
Repair leaking bait tank piping in lazerette.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 8 May 2017
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 2 May 2017 Resolved
Provide 02 children's lifejackets. You may not carry more children than you have children's lifejackets.
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 8 May 2017
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 2 May 2017 Resolved
Provide emergency broadcast placard near radios.
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 8 May 2017
Navigation › Piloting/Steering › Magnetic Compass
Issued 2 May 2017 Resolved
Provide working magnetic compass light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 8 May 2017
Construction/Loadline › Hull › Transverse Frame
Issued 10 November 2016 Resolved
Provide repair proposal for fractured frame tops, frame #6, 5, 4, 3, on port bow, also for fractured deck beam connection in way of frame #6, port bow. Vessel owner representative and master opted to scarf-in new frame pieces, and scarf-in new deck beam piece.
Action required: 705 - Other - as specified
Resolved 22 November 2016
Resolution: See Narrative.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 10 November 2016 Resolved
Repaint draft marks.
Action required: 705 - Other - as specified
Resolved 18 November 2016
Resolution: Draft marks painted, port and stbd bow.
Construction/Loadline › Hull › Hull Plating
Issued 10 November 2016 Resolved
Provide new through-fastening for stbd bow butt block.
Action required: 705 - Other - as specified
Resolved 18 November 2016
Resolution: New fastener installed, all satisfactory.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 10 November 2016 Resolved
Ensure watertight integrity of all watertight bulkheads, as identified.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 18 November 2016
Resolution: See Narrative.
Fire Fighting › Ventilation Systems › Ducts
Issued 5 July 2016 Resolved
Install adequate provisions for closing all supply and exhaust duct discharge openings in engine room
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2016
Resolution: Supply and exhaust ventilation covers now installed Supply and exhaust ventilation covers now installed
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 5 July 2016 Resolved
Provide simple instructions for CO2 discharge pull lever
Due 5 August 2016
Resolved 14 September 2016
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 5 July 2016 Resolved
Relocate CO2 pressure control switch
Action required: 705 - Other - as specified
Due 5 August 2016
Resolved 14 September 2016
Fire Fighting › Means of Escape › Blocked
Issued 5 July 2016 Resolved
Make forward escape hatch readily accessible
Action required: 705 - Other - as specified
Due 5 August 2016
Resolved 7 July 2016
Resolution: Forward escape patch now operational
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 5 July 2016 Resolved
Provide modular smoke detectors in all overnight accommodations
Action required: 705 - Other - as specified
Due 5 August 2016
Resolved 7 July 2016
Resolution: Smoke detectors now installed in all overnight accommodations
Fire Fighting › Means of Escape › Escape Route Signs
Issued 5 July 2016 Resolved
Properly label both sides of middle emergency escape hatch
Action required: 705 - Other - as specified
Due 5 August 2016
Resolved 7 July 2016
Resolution: Both sides of middle escape patch now properly labeled
Navigation › Piloting/Steering › Marine Charts
Issued 5 July 2016 Resolved
Provide current marine charts for area of operation
Action required: 705 - Other - as specified
Due 5 August 2016
Resolved 7 July 2016
Resolution: Marine charts now provided for area of operation
Communications › Public Address System › Amplifier
Issued 5 July 2016 Resolved
Provide suitable public address system to be heard throughout the Vessel
Action required: 705 - Other - as specified
Due 5 August 2016
Resolved 7 July 2016
Resolution: PA system now installed
Operations/Management › Drills/Instruction › Not Conducted
Issued 5 July 2016 Resolved
Complete underway drills in the presence of the attending marine inspector
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 August 2016
Resolved 7 July 2016
Resolution: Satisfactory drills completed

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.