MAURY USCG vessel records
← All vessels

MARSHLAND 201

Built
1996
Last inspected
5 August 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 5 August 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 27 calendar years (1996–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

441096
Flag
UNITED STATES
Maury page id
psix-441096

Documentation record

Registered dimensions (L × B × D)130.0 ft × 32.0 ft × 7.0 ft
Registered tonnagegross 244 / net 244
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderA&M DOCKSIDE REPAIR INC · AMELIA, LA, UNITED STATES · built 1996
Hull materialSteel
PropulsionNone
Hull shapeBox
Hull configurationMonohull
Hailing portMORGAN CITY, LA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 9 September 2025 · expires 31 October 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it244 - Simplified, Gross Ton
244 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 40 inspections, each with its date, unit and type; 9 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 40

5 August 2025 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8202867
3 October 2024 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8014052
22 June 2023 Periodic Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7720875
24 October 2022 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7578665
10 November 2021 Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7348597
9 October 2021 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7360942
7 August 2020 COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7026635
22 July 2019 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6760523
20 June 2018 Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6709949
20 September 2017 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6271175
28 November 2016 Internal Structural Exam · Hull Examination · Administrative Inspection · Annual Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6048355
17 August 2015 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5219290
9 January 2015 Examination of Repairs · Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5050687
18 September 2013 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4716938
4 January 2012 Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4218515
7 November 2011 Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4183814
9 November 2010 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3888095
21 January 2010 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3667602
1 December 2008 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3372287
21 December 2007 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3119224
9 February 2007 Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2869818
16 November 2006 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2821899
19 December 2005 COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2553549
6 October 2005 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2508989
31 August 2005 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2480414
29 November 2004 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2250011
23 November 2004 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2246841
11 May 2004 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2071441
22 March 2004 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2028911
10 March 2004 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2021872
5 February 2004 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2000880
29 January 2004 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 1996928
29 October 2002 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1697772
22 October 2001 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1389491
3 October 2001 Examination of Repairs · Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1469715
19 December 2000 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1376400
2 November 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1365443
12 November 1998 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1456654
27 October 1997 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1427426
18 November 1996 Initial Construction-Excluding Oversight · Hull Examination · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1400401

Deficiency record · 9

09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 3 October 2024 Resolved
All exposed and dangerous places such as gears and machinery shall be properly protected with covers, guards or rails in order that the danger of accidents may be minimized. No moving guard over drive belt on prime mover. 46CFR32.02-15
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2024
Resolved 9 October 2024
Resolution: Moving guard installed over drive belt. Deficiency cleared.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 3 October 2024 No resolution recorded
The inspection for certification shall include an inspection of the structure, boilers, and other pressure vessels, machinery and equipment. Found wasted longitudinal in stern rake stbd side. 46CFR31.10-15(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Engineering › Fuel Oil Service System › Hose
Issued 17 August 2015 Resolved
Flexible fuel supply hose over 30 inches.
Due 18 August 2015
Resolved 18 August 2015
Resolution: Lengthened fuel pipe to engine, shortened flexible hose.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 17 August 2015 Resolved
Missing mechanical plug for fixed containment around transfer connections.
Due 18 August 2015
Resolved 18 August 2015
Resolution: Placed plugs in perspective containment.
Construction/Loadline › Hull › Longitudinal Frame
Issued 7 November 2011 Resolved
01DEC11:Granted barge an additional 30 days to make repairs. Crop and renew wasted angles and gussetts in the vacinity of the hatch openings of all wing tanks. Several pick up welds located in wing voids in need of repair. Vessel rep was briefed on details of required repairs. CG-835 was issued giving vsl 30 days to make repairs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 January 2012
Resolved 4 January 2012
Resolution: Attended barge, inspected repairs to items called out during ISE. Repairs were satisfactory. Cleared CG-835.
Engineering › Diesel Engine (auxiliary) › Block
Issued 19 December 2005 Resolved
Pump prime mover was covered with Liquid Mud and appeared unfit to be operated until properly cleaned. Vessel rep was unwilling to run prime mover in its situation.
Condition: Improper/Lack of Maintenance
Due 21 December 2005
Resolved 21 December 2005
Resolution: Witnessed operational test and properly cleaned prime mover.
Engineering › Diesel Engine (auxiliary) › Valve, Check (air start)
Issued 19 December 2005 Resolved
Vessel did not have required emergency shutdowns installed and operational.
Due 21 December 2005
Resolved 21 December 2005
Resolution: Inspected satisfactory pump prime mover emergency shutdown operation.
Engineering › Fuel Oil Service System
Issued 5 February 2004 Resolved
F/O service tank for barge pump is not equipped with a ventilation pipe. Tank is approved for use on large highway trucks and tank is built to vent through fill cap. This arrangement does not meet regulations as per 46 CFR sub chapter F. LEGACY COMPONENT DESC: Vent Pipe
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 March 2004
Resolved 16 March 2004
Resolution: Properly installed tank vent in accordance with applicable regulations.
Documentation › Safety/Response Plans/Programs
Issued 5 February 2004 Resolved
Vessel did not have current Vessel Response Plan approval letter onboard and did not have the necessary sections that are required for an unmanned tank barge. Provide current approval letter and emergency procedure section of plan. LEGACY COMPONENT DESC: Vessel Response Plan
Action required: 705 - Other - as specified
Due 5 March 2004
Resolved 4 March 2004
Resolution: received current approval letter for vessel response plan

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.