Records from 2002 to 2025. Most recent: inspection, 2 October 2025.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 October 2025
Resolved
Life ring light was broken and battery was expired. Replace battery and light.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 October 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 October 2025
Resolved
Life ring was fitted with 60' of line. Attach 60' of line to the required life ring.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 October 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 October 2025
Resolved
The upper deck forward life jacket storage box was obstructed. Remove obstruction from opening the life jacket storage box.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 October 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 October 2025
Resolved
Forward hold bilge float switch was unsecured. Secure the float switch and ensure proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 October 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 October 2025
No resolution recorded
Fire pump did not produce sufficient stream to adequately fight a fire. Repair/replace fire pump as needed to ensure sufficient stream of water from the fire hose to fight a fire. Correct prior to the 2026 operating season.
Action required: 705 - Other - as specified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 21 August 2024
Resolved
Vessel lost propulsion due to the loss of fuel. Conduct necessary repairs to fuel and propulsion system. Prove proper operation to the attending marine inspector prior to getting underway with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 August 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 August 2024
Resolved
Vessels engine room bilge alarm was found unsecured in the bilge. On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided. Vessel owner shall repair or replace the bilge alarm.
Action required: 10 - Deficiency Rectified
Resolved 13 August 2024
Resolution: Corrected on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 May 2023
Resolved
Main Diesel Engine loss of propulsion. Propulsion machinery must be capable of operating at constant marine load under such requirements without exceeding its designed limitations. Diagnose and repair the main diesel engine to proper working condition. Provide marine inspector with diagnostic report.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2023
Resolved 20 May 2023
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 11 August 2021
Resolved
The vessels engine room secondary means of escape was blocked by old oil cans and spare parts. Spare parts and debris shall be moved to another section of the vessel to ensure proper clearance/use of emergency escape hatch.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 25 August 2021
Resolved 23 August 2021
Resolution: recieved notification rectifying def from o/o
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 11 August 2021
Resolved
Vessel did not have the required amount of flares on board.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 11 August 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 August 2021
Resolved
Vessels main engine coolant line bracket was found unsecured. The bracket should be put back on to ensure no damage is caused due to vibration.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 September 2021
Resolved 23 August 2021
Resolution: recieved notification rectifying def from o/o
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 August 2020
Resolved
Replace cracked fire main pipe at hydrant & prove proper operations. Correction required prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 August 2020
Resolved 18 August 2020
Resolution: Received picture of replaced pipe (elbow) & video of operation of fire pump with sat results.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 18 August 2020
Resolved
As required by the provided cite install metallic pipe with metallic valve or blank unused discharge at the side shell.
Action required: 705 - Other - as specified
Due 30 April 2021
Resolved 14 January 2021
Resolution: Vessel is in compliance with 46 CFR 179.350. Overboard discharge and valve for holding tank is not required to be metalallic.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 18 August 2020
Resolved
Ring buoy water light battery expired requiring replacement.
Action required: 705 - Other - as specified
Due 28 August 2020
Resolved 21 August 2020
Resolution: Received text msg from POC upon installation of new battery with statement attesting to the sat ops of light.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 21 May 2020
Resolved
Provide plan for the replacement of hull plating identified wasted beyond allowable within the #1 & #2 voids both port & starboard sides. Plan must be approved prior to commencing repairs with repairs required prior to commerical operations.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 May 2020
Resolved 26 June 2020
Resolution: Final weld inspection of inserted plate completed this date with ndt consisting of vt & at sat. See narrative for amplification.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 20 May 2020
Resolved
Replace check valve / pick up screen for void #1 and waste water piping at port ss ivo fwd main deck access.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 May 2020
Resolved 26 June 2020
Resolution: New pickup screen/check valve & waste water piping installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 July 2019
Resolved
Provide wire supports and chaffing gear for bilge alarm wires.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2019
Resolved 31 July 2019
Resolution: Attended vessel witnessing satisfactory correction of requirement.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 30 July 2019
Resolved
Correct leaking bilge piping within void #2.
Action required: 705 - Other - as specified
Due 6 August 2019
Resolved 31 July 2019
Resolution: Attended vessel witnessing satisfactory correction of requirement.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 July 2019
Resolved
Remove fire load from liquor locker.
Action required: 705 - Other - as specified
Due 2 August 2019
Resolved 31 July 2019
Resolution: Attended vessel witnessing satisfactory correction of requirement.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 30 July 2019
Resolved
Properly secure gen set battery.
Action required: 705 - Other - as specified
Due 2 August 2019
Resolved 31 July 2019
Resolution: Attended vessel witnessing satisfactory correction of requirement.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 30 July 2019
Resolved
Provide wire support for gen set positive lead currently laying on deck and between deck plates.
Action required: 705 - Other - as specified
Due 2 August 2019
Resolved 31 July 2019
Resolution: Attended vessel witnessing satisfactory correction of requirement.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 30 July 2019
Resolved
Correct leaking fuel line for gen set and prove proper operation.
Action required: 705 - Other - as specified
Due 2 August 2019
Resolved 31 July 2019
Resolution: Attended vessel witnessing satisfactory correction of requirement.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 30 July 2019
Resolved
Removed dead ended wires and provide protection of wires within pilot house.
Action required: 705 - Other - as specified
Due 2 August 2019
Resolved 31 July 2019
Resolution: Attended vessel witnessing satisfactory correction of requirement.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 30 July 2019
Resolved
Provide required quantity of distress flares on board vessel. Vessel is limited to day time operation on the Erie Barge Canal until provided.
Action required: 705 - Other - as specified
Due 30 July 2019
Resolved 31 July 2019
Resolution: Attended vessel witnessing satisfactory correction of requirement.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 July 2019
Resolved
Provide appropriate lanyard for ring buoy.
Action required: 705 - Other - as specified
Due 30 July 2019
Resolved 31 July 2019
Resolution: Attended vessel witnessing satisfactory correction of requirement.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 30 July 2019
Resolved
Provide extended handle for fire pump actuation arm to allow operation without operators hand entering cage.
Action required: 705 - Other - as specified
Due 2 August 2019
Resolved 31 July 2019
Resolution: Attended vessel witnessing satisfactory correction of requirement.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 30 July 2019
Resolved
Provide required medical equipment - list provided.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2019
Resolved 9 August 2019
Resolution: Received email from owner attesting to all required gear provide on board vessel.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 30 July 2019
Resolved
Required company provide and implement safety plan/SOP to mitigate operational risks for passage under fixed bridges.
Action required: 705 - Other - as specified
Due 9 August 2019
Resolved 2 August 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 8 July 2019
Resolved
Repair or replace damaged rail upper deck aft to prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 July 2019
Resolved 11 July 2019
Resolution: Received photo of replaced section of railing, cleared requirement with verification to be completed during annual inspection.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 August 2018
Resolved
Temp gen set authorized with the following measure complete: Make connection to generator panel through separate opening, Provide cable protection at 3 areas where cable passes over metal surfaces, support IVO overhead within the starboard gear locker and within vertical cable-way to maintain radius at lower bend, refuel until only when unit is cool and no passengers are on board, extra fuel not to be on board vessel, complete pre-operations checks IAW manufactures guidance and log same within vessel's log.
Action required: 10 - Deficiency Rectified
Due 14 August 2018
Resolved 14 August 2018
Resolution: Temp installation corrected prior to operations.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 August 2018
Resolved
Repair or replace generator - prove proper operations.
Action required: 705 - Other - as specified
Due 14 August 2018
Resolved 30 August 2018
Resolution: Attended vessel witnessing satisfactory operation of fixed gen set. Awaiting brief from tech as to failed parts, failure factors and suggested course to prevent reoccurrence.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 July 2018
Resolved
Prove proper operation of the bilge pumping system prior to commercial operations.
Action required: 10 - Deficiency Rectified
Due 16 July 2018
Resolved 19 July 2018
Resolution: Piping repairs with training of masters and crew completed - satisfactory operational test of bilge systems.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 16 July 2018
Resolved
Replace electrical outlet cover main deck forward ivo cooler.
Action required: 10 - Deficiency Rectified
Due 23 July 2018
Resolved 19 July 2018
Resolution: Cover replaced.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 16 July 2018
Resolved
Remove excessive oil / water from bilge within engine room and void # 3 prior to commercial operations and maintain prior to commercial operations. 185.315 -
Action required: 10 - Deficiency Rectified
Due 16 July 2018
Resolved 19 July 2018
Resolution: Oil & water removed bilge with clear sorbents installed.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 16 July 2018
Resolved
Prove proper operation of the bilge high water alarms, visual and auditable.
Action required: 10 - Deficiency Rectified
Due 16 July 2018
Resolved 19 July 2018
Resolution: Switches for lazeratte and shaft space replaced with demonstration of all alarms completed with satisfactory results.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 July 2018
Resolved
Replace grab line on ring buoy or replace prior to commercial operations.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 July 2018
Resolved 16 July 2018
Resolution: Ring buoy replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 July 2018
Resolved
Removed dead ended wires under pilot station.
Action required: 10 - Deficiency Rectified
Due 30 July 2018
Resolved 19 July 2018
Resolution: Wires removed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 July 2018
Resolved
Log pre-underway checks as required on vessels COI. Checks must include the vessels draft, bilge alarms, steering and communication systems.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 July 2018
Resolved 16 July 2018
Resolution: Log entry completed.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 16 July 2018
Resolved
Complete crew training on emergency procedures and provide demonstration of same.
Action required: 10 - Deficiency Rectified
Due 16 July 2018
Resolved 19 July 2018
Resolution: Training completed and logged with satisfactory demonstration of installed emergency systems.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 16 July 2018
Resolved
Extend sleeve for emergency tiller and demonstrate operation.
Action required: 10 - Deficiency Rectified
Due 23 July 2018
Resolved 19 July 2018
Resolution: Welded flange installed allowing crew to install emergency tiller.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 July 2018
Resolved
Replace leaking bilge pipe within voids #3 and #5.
Action required: 10 - Deficiency Rectified
Due 16 July 2018
Resolved 19 July 2018
Resolution: New pipes installed with satisfactory system test completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 16 July 2018
Resolved
Prove proper operation of engine local shutdown switch. 182.200
Action required: 10 - Deficiency Rectified
Due 16 July 2018
Resolved 19 July 2018
Resolution: Switch replaced.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 16 July 2018
Resolved
Provide means of recovery and demonstration of same.
Action required: 10 - Deficiency Rectified
Due 16 July 2018
Resolved 19 July 2018
Resolution: Means of recovery provided (latter with platform) with satisfactory demonstration by crew provided.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 July 2018
Resolved
Provide adequate covering for battery box within engine room. Removed old batteries on deck.
Action required: 10 - Deficiency Rectified
Due 16 July 2018
Resolved 19 July 2018
Resolution: Battery cover installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 July 2018
Resolved
Remove wire nuts found within engine room junction box.
Action required: 10 - Deficiency Rectified
Due 16 July 2018
Resolved 14 August 2018
Resolution: Wire installation corrected,
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 July 2018
Resolved
Provide adequate reach rod for forepeak bilge valve. 182.25-5(d)/182.510(d). At request of POC extended requirement.
Action required: 705 - Other - as specified
Due 14 September 2018
Resolved 2 July 2019
Resolution: Attended vessel witnessing main deck coolers moved to allow access to reach rod. Tested installation with sat results.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 July 2018
Resolved
Hard wire outlet for speaker system within main deck forward. 183.340(b)/(d). At the request of POC extended requirement.
Action required: 705 - Other - as specified
Due 14 September 2018
Resolved 2 July 2019
Resolution: Attended vessel witnessing new outlet installed ivo forward mounted speaker.
Engineering › Bilge Water Management System › Strainer
Issued 16 February 2017
Resolved
Bilge suction strainer in number 2 void needs to be reattached to bilge pipe.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 23 June 2017
Resolution: Bilge strainer was reattached.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 16 February 2017
Resolved
Identify and correct cause of water coming into number 2 void.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 23 June 2017
Resolution: Cleared to the satisfaction of the attending marine inspector.
Construction/Loadline › Hull › Side Shell
Issued 16 February 2017
Resolved
Submit plan to mitigate and prevent excessive deterioration of both port and starboard rub rails.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 23 June 2017
Resolution: The starboard and port rub rail was cut out and treated to prevent deterioration of the hull.
Documentation › Certificates/Documents › FCC SSL
Issued 26 April 2016
Resolved
Check the status/ obtain renewal of FCC station license
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 May 2016
Resolved 17 May 2016
Resolution: Provided proof of renewal of FCC station license
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 26 April 2016
Resolved
Secure BI extinguisher in storage space; secure BII by hydrant
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 May 2016
Resolved 17 May 2016
Resolution: Mounted and secured BI and BII extinguisher
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 26 April 2016
Resolved
Provide proof of FCC Marine Radio Operators permits for all operators
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 May 2016
Resolved 17 May 2016
Resolution: Obtained marine radio operator permit
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 26 April 2016
Resolved
Replace expired first aid kit items
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2016
Resolved 17 May 2016
Resolution: Replaced expired first aid items
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 26 April 2016
Resolved
Secure lifeline around the body of the STBD ring buoy
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 May 2016
Resolved 17 May 2016
Resolution: Secured lifeline around the body of the ring buoy
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 26 April 2016
Resolved
Waterlight inoperative on ring buoy
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 May 2016
Resolved 28 April 2016
Resolution: Waterlight is operable; replaced battery
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 26 April 2016
Resolved
Stencil vessel name on ring life buoys
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 May 2016
Resolved 28 April 2016
Resolution: Stenciled vessel name on ring life buoys
Deck/Cargo › Mooring/Anchoring › Anchor Rope
Issued 26 April 2016
Resolved
Attach adequate length of appropriate anchor line to anchor; properly secure anchor line to vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 May 2016
Resolved 17 May 2016
Resolution: Attached anchor line to anchor
Stability › Unintentional Flooding › General
Issued 26 April 2016
Resolved
Label high water bilge alarms at operating station
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 May 2016
Resolved 17 May 2016
Resolution: Labeled high water alarms at operating station
Construction/Loadline › Structures › Deck Plating
Issued 26 April 2016
Resolved
Clean/ dry/ apply preservative coating to deck areas IVO STBD sliding door
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2016
Resolved 17 May 2016
Resolution: Cleaned and applied preservative coating to deck areas IVO the STBD sliding door
Engineering › Freshwater System (jacketwater cooling) › Valve
Issued 26 April 2016
Resolved
Prove proper operation of keel cooler valves
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2016
Resolved 28 April 2016
Resolution: maintained the keel cool valves
Engineering › Fuel Oil Service System › Hose
Issued 26 April 2016
Resolved
Repair fuel leak on generator return hose; replace hose and clamps
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 May 2016
Resolved 28 April 2016
Resolution: return line on the generator has been replaced and is no longer leaking
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 26 April 2016
Resolved
STBD aft generator mount loose
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2016
Resolved 28 April 2016
Resolution: repaired the generator engine mount
Electrical › Electric Supply System (service) › Battery Installation
Issued 26 April 2016
Resolved
Clean out oil in generator batter box, clean battery terminals
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2016
Resolved 28 April 2016
Resolution: battery box and terminals have been cleaned
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (electric)
Issued 26 April 2016
Resolved
Loose starter connections, MDE
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2016
Resolved 28 April 2016
Resolution: wiring on the solenoid tightened
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 26 April 2016
Resolved
Clean debris and oil from bilges; prior to carrying pax
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 May 2016
Resolved 28 April 2016
Resolution: Cleaned debris and oil from bilges
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 26 April 2016
Resolved
Properly secure compressor wire nuts
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 May 2016
Resolved 28 April 2016
Resolution: Properly secured wire nuts