MAURY USCG vessel records Sign in
← All vessels

BANNER

BANNER is a 1961 freight ship. The Coast Guard has recorded 32 inspections since 1985, most recently in January 2008, along with 95 deficiencies — 1 with no resolution recorded —.

Records from 1985 to 2008. Most recent: inspection, 16 January 2008.

Built
1961
Last inspected
16 January 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

5111000 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
UNITED STATES
—
Maury page id
psix-44112

Inspections, by type

…with no type recorded7
…past their stated due date1
Years with a record 15 calendar years (1985–2008)
The 32 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it10659 - Regulatory (Subpart C or D), Gross Ton
7939 - Dual (D), Gross Ton
6465 - Regulatory (Subpart C or D), Net Ton
4466 - Dual (D), Net Ton
12629 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WFGTMMSI not assigned · expired · compulsorily equipped · granted 30 November 1995, cancelled 4 February 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 32

16 January 2008 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3139301
26 April 2000 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1049336
6 August 1999 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 775144
30 June 1999 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1082916
27 August 1998 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1392964
15 June 1998 COI Inspection · Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1472800
13 May 1998 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1125989
10 March 1998 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 786229
5 March 1998 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1118689
18 November 1997 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1450113
14 September 1997 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1381000
14 August 1997 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1388343
14 May 1996 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1417930
10 September 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1188288
22 September 1993 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1151920
8 July 1993 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1154616
21 August 1992 COI Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1259209
27 September 1991 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 936433
19 September 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 938912
26 June 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1249433
16 May 1991 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1234944
24 April 1991 Examination of Repairs
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1228233
21 January 1991 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1303384
10 October 1990 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 931977
21 September 1990 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 931355
9 October 1988 Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 888416
19 July 1988 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1035963
4 February 1987 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1015994
22 July 1986 Examination of Repairs
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1009644
22 April 1986 Permit to Proceed
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 999942
21 May 1985 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1289725
7 February 1985 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1288477

Deficiency record · 95

Electrical
Issued 15 June 1998 Resolved
PROVIDE SHUTDOWN INSTRUCTIONS FOR EDG.
Condition: Unknown
Due 29 June 1998
Resolved 29 June 1998
Electrical
Issued 15 June 1998 Resolved
PROVE OPERATION OF LOW LUBE OIL AUDIBLE ALARM ON EDG.
Condition: Unknown
Due 29 June 1998
Resolved 29 June 1998
Electrical
Issued 15 June 1998 Resolved
PROPERLY MARK F/O REMOTE SHUTDOWN VALVE ON EDG
Condition: Unknown
Due 29 June 1998
Resolved 29 June 1998
Construction/Loadline
Issued 15 June 1998 Resolved
PROVE PROPER OPERATION OF BILGE PUMP
Condition: Unknown
Due 29 June 1998
Resolved 29 June 1998
Electrical
Issued 15 June 1998 Resolved
PROVIDE ELECTRICAL PROTECTION MAT FOR SWITCHBOARD IN EDG ROOM & ALL PANELS IN MACHINERY SPACES.
Condition: Unknown
Due 29 June 1998
Resolved 29 June 1998
Electrical
Issued 15 June 1998 Resolved
PROVE PROPER OPERATION & PROVIDE MARKING FOR ALL EMERGENCY LIGHTING.
Condition: Unknown
Due 29 June 1998
Resolved 29 June 1998
Unknown
Issued 15 June 1998 No resolution recorded
PRIOR TO ACTIVATION/COI, CONDUCT OPERATIONAL TEST OF BOILERS, MAIN PROPULSION, TURBINE GENERATORS, ALL AUXILLARY ENG EQUIPMENT, SET BOILER SAFETIES & CONDUCT FIRE/BOAT DRILLS WITH CREW. ALL REQUIREMENTS SHALL BE MET TO THE SATISFACTION OF THE ATTENDING [name withheld] ACTIVATION.
Condition: Unknown
Due 15 June 2000 — due date passed with no resolution recorded
Electrical
Issued 15 June 1998 Resolved
PROVE OPERATION OF J/W HIGH TEMP ALARM ON EDG.
Condition: Unknown
Due 29 June 1998
Resolved 29 June 1998
Electrical
Issued 14 September 1997 Resolved
RENEW ALL DETERIORATED/MISSING ELECTRICAL CABLE SUPPORTS LOCATED ON THE WEATHER DECKS IN ACCORDANCE WITH THE REQUIREMENTS OF IEEE STANDARD 45 SECTION 20._x001C_ 46 CFR 111.60-5
Condition: Unknown
Due 14 September 1997
Resolved 14 September 1997
Construction/Loadline
Issued 14 September 1997 Resolved
RENEW DETERIORATED AND MISSING PACKING TO ALL ELECTRICAL CABLE PENETRATIONSTHROUGH THE WEATHER DECK TO ENSURE A WEATHERTIGHT SEAL._x001C_ _x001C_ 46 CFR 171.122_x001C_
Condition: Unknown
Due 14 September 1997
Resolved 14 September 1997
Lifesaving
Issued 14 September 1997 Resolved
RENEW AS ORIGINAL IN ACCORDANCE WITH NVIC 2-63, DETERIORATED AND IMPROPERLYREPAIRED GRAB RAILS ON THE PORT AND STARBOARD LIFEBOATS. (REMOVE POP RIVETSAND INSTALL PROPER FASTENERS) _x001C_ _x001C_
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Construction/Loadline
Issued 14 September 1997 Resolved
RENEW MISSING DOGGING DEVICES TO THE TWO WATERTIGHT DOORS LOCATED IMMEDIATELY AFT OF THE #6 CARGO HOLD MAIN HATCH._x001C_ _x001C_ 46 CFR 42.15-10
Condition: Unknown
Due 14 September 1997
Resolved 14 September 1997
Electrical
Issued 14 August 1997 Resolved
PROVIDE PROTECTIVE GLOBE FOR LIGHT IN FORWARD DECK LOCKER
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Electrical
Issued 14 August 1997 Resolved
REMOVE DEAD END ELECTRICAL CABLES FROM THE FOLLOWING LOCATIONS: BRIDGE-PORTSIDE OVERHEAD FORWARD, #19 TOP CARGO GEAR HOIST, AND ABOVE #3 HOIST
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Lifesaving
Issued 14 August 1997 Resolved
PROVIDE PROPER SAFETY GUARD TO GRINDING WHEEL IN MACHINE SHOP IN ER
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Electrical
Issued 14 August 1997 Resolved
REPAIR/REPLACE AND PROVE PROPER OPERATION OF EMERGENCY DIESEL OVERSPEED TRIP AUDIBLE ALARM.
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Construction/Loadline
Issued 14 August 1997 Resolved
REPLACE AS NEEDED ALL WASTED BOLTS ON ALL CARGO HATCH COVER HINGES
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Electrical
Issued 14 August 1997 Resolved
ENSURE ELECTRICAL OUTLET COVERS ARE PROPERLY INSTALLED THROUGHOUT VSL
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Electrical
Issued 14 August 1997 Resolved
PROVIDE NON CONDUCTIVE BLANK FOR PANEL 1-155-L, IN GALLEY
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Accommodation/Occupational Safety
Issued 14 August 1997 Resolved
PROPERLY INSTALL SIGHTGLASS TO DISTILLING TANK, STBD SIDE LOWER ER
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Construction/Loadline
Issued 14 August 1997 Resolved
REPLACE (CROP AND RENEW) WASTED ANGLE SUPPORTS FOR ENGINE MOTOR HEAT STRIP D/S UNIT ON WEATHER DECK
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Electrical
Issued 14 August 1997 Resolved
PROVIDE NON CONDUCTIVE BLANK FOR PANEL 1-105-L #5 MG HOUSING
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Navigation
Issued 14 August 1997 Resolved
PROVE PROPER OPERATION OF MASTHEAD LIGHT ALARM AND LIGHT INDICATORS.
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Navigation
Issued 14 August 1997 Resolved
PROVE PROPER OPERATION OF RUDDER ANGLE INDICATOR AND ENGINE ORDER TELEGRAPHPOWER FAILURE ALARMS
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Fire Fighting
Issued 14 August 1997 Resolved
PROPERLY MARK FIRE DAMPERS AT LOCATIONS 26, 33,AND 37 AT #6 MG HOUSING, ENSURE ALL FIRE DAMPERS ARE PROPERLY STENCILED.
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Construction/Loadline
Issued 14 August 1997 Resolved
REPLACE WASTED BOLTS, PORT LIFEBOAT INBOARD AFT SHEAVE FOUNDATION, INBOARD FORWARD SHEAVE FOUNDATION, STARBOARD LIFEBOAT LIMIT SWITCH(FORWARD) AND OTHER WASTED BOLTS AS NEEDED.
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Lifesaving
Issued 14 August 1997 Resolved
PROVE PROPER OPERATION OF AND PROPERLY MARK GENERAL ALARM BELL LOCATED PORTSIDE FORWARD BULKHEAD OF AFTER HOUSE
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Deck/Cargo
Issued 14 August 1997 Resolved
RENEW WASTED SPOOL PIECE TO VENT TRUNK FOR CARGO AIR SUPPLY SYSTEM #2 HOLD,EXAMINE ALL VENT DUCTING IN ALL MG HOUSING COMPARTMENTS FOR LEAKS AND PROPERLY REPAIR AS NEEDED
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Accommodation/Occupational Safety
Issued 14 August 1997 Resolved
PROPERLY IDENTIFY AND STENCIL ALL VENTILATION DUCTS.
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Deck/Cargo
Issued 14 August 1997 Resolved
IDENTIFY AND REPLACE AS NEEDED WASTED CABLE RUN STRAPS ABOVE HOISTS
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Accommodation/Occupational Safety
Issued 14 August 1997 Resolved
PROPERLY INSTALL SIGHTGLASS TO SANITARY TANK, LOWER LEVEL ER AND INSTALL BETTER PROTECTIVE GUARDS AROUND GLASS
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Electrical
Issued 14 August 1997 Resolved
PROVIDE BLANKS AND PROPERLY SECURE COVER TO DISTRIBUTION PANEL P-40 IN ENGINE ROOM
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Engineering
Issued 14 August 1997 Resolved
INSTALL HAND RAIL OUTBOARD PORT BOILER IN WAY OF FORCED DRAFT BLOWERS.
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Electrical
Issued 14 August 1997 Resolved
REPAIR AND PROVE PROPER OPERATION OF AUDIBLE ALARM SYSTEM FOR EMERGENCY DIESEL GENERATOR. ONLY CORRECT ALARM SHOULD SOUND WITH EACH TEST NOT ALL.
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Electrical
Issued 14 August 1997 Resolved
PROPERLY ADJUST OVERSPEED ON EDG TO TRIP BETWEEN 110 AND 115% OF OPERATING RPM
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Lifesaving
Issued 22 September 1993 Resolved
PROVIDE BATTERIES FOR ALL RING BOUY LIGHTS UPON ACTIVATION.
Condition: Unknown
Due 22 September 1993
Resolved 22 September 1993
Lifesaving
Issued 22 September 1993 Resolved
PROVIDE ALL PERISHABLE PROVISIONS FOR BOTH PORT & STBD LIFEBOATS UPON ACTIVATION.
Condition: Unknown
Due 22 September 1993
Resolved 22 September 1993
Fire Fighting
Issued 22 September 1993 Resolved
CONDUCT A FIRE AND BOAT DRILL TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR UPON ACTIVATION.
Condition: Unknown
Due 22 September 1993
Resolved 22 September 1993
Lifesaving
Issued 22 September 1993 Resolved
PROVIDE ALL REQUIRED PYROTECHNICS UPON ACTIVATION.
Condition: Unknown
Due 22 September 1993
Resolved 22 September 1993
Lifesaving
Issued 22 September 1993 Resolved
PROVIDE AN APPROVED LINE THROWING DEVICE UPON ACTIVATION.
Condition: Unknown
Due 22 September 1993
Resolved 22 September 1993
Lifesaving
Issued 22 September 1993 Resolved
PROVIDE 1 IMMERSION SUIT PER CREWMEMBER UPON ACTIVATION.
Condition: Unknown
Due 22 September 1993
Resolved 22 September 1993
Lifesaving
Issued 21 August 1992 Resolved
PROVIDE ALL PERISHABLE PROVISIONS FOR BOTH PORT AND STBD LIFEBOATS UPON ACTIVATION._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 August 1992
Resolved 21 August 1992
Lifesaving
Issued 21 August 1992 Resolved
PROVIDE AN APPROVED LINE THROWING APPARATUS UPON ACTIVATION BUT IN NO CASE NO LATER THAN 21AUG93.
Condition: Unknown
Due 21 August 1992
Resolved 21 August 1992
Fire Fighting
Issued 21 August 1992 Resolved
CONDUCT A FIRE + BOAT DRILL TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR UPON ACTIVATION. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 August 1992
Resolved 21 August 1992
Lifesaving
Issued 21 August 1992 Resolved
PROVIDE ALL REQUIRED PYROTECHNICS UPON ACTIVATION BUT NO LATER THAN 21AUG93.
Condition: Unknown
Due 21 August 1992
Resolved 21 August 1992
Lifesaving
Issued 21 August 1992 Resolved
PROVIDE 1 IMMERSION SUIT PER CREW MEMBER UPON ACTIVATION BUT NO LATER THAN 21AUG93.
Condition: Unknown
Due 21 August 1992
Resolved 21 August 1992
Fire Fighting
Issued 21 August 1992 Resolved
REPLACE/REPAIR THE FIRE DETECTION SYSTEM UPON ACTIVATION BUT NO LATER THAN 21AUG93.
Condition: Unknown
Due 21 August 1992
Resolved 21 August 1992
Lifesaving
Issued 21 August 1992 Resolved
PROVIDE BATTERIES FOR ALL RING BUOY LIGHTS UPON ACTIVATION OR NO LATER THAN21AUG93.
Condition: Unknown
Due 21 August 1992
Resolved 21 August 1992
Electrical
Issued 21 January 1991 Resolved
REPLACE/REPAIR VOLTAGE REGULATOR/FOR AND EXCITERS/ON 1 AND 2 SHIPSERVICE_x001C_ GENERATOR. SHIP SERVICE GENERATORS NOT TO BE OPERATED IN PARALLE.
Condition: Unknown
Due 21 January 1991
Resolved 21 January 1991
Electrical
Issued 21 January 1991 Resolved
PROVE PROPER OPERATION OF REVERSE-CURRENT RELAYS AFTER COMPLETION OF E . _x001C_OPERATION OF 1 AND 2 S/S GENERATORS TO BE IN PARALLE TO BE INCLUDED IN _x001C_PROOF._x001C_
Condition: Unknown
Due 21 January 1991
Resolved 21 January 1991
Engineering
Issued 9 October 1988 Resolved
OPERATE FUEL OIL SERVICE AND TRANSFER PUMPS AND TEST REMOTE SHUTDOWNS FOR SAME.
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Engineering
Issued 9 October 1988 Resolved
OPERATE UNDER A LOAD AND TEST SAFETY DEVICES OF EACH FEEDWATER PUMP.
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Navigation
Issued 9 October 1988 Resolved
TEST ALL NAVIGATION LIGHTS AND ELECTRONIC NAVIGAITON EQUIPMENT.
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Navigation
Issued 9 October 1988 Resolved
PROVIDE ALL REQUIRED NAVIGATIONAL CHARTS, PUBLICATIONS, REQUIRED FORMS AND NOTICES.
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Deck/Cargo
Issued 9 October 1988 Resolved
DEMONSTRATE SATISFACTORY OPERATION OF GROUND TACKLE AND WARPING CAPSTANS.
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Construction/Loadline
Issued 9 October 1988 Resolved
REPAIR/RENEW NUMEROUS WEATHERDECK VENTS AND CLOSURES.
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Accommodation/Occupational Safety
Issued 9 October 1988 Resolved
PROVIDE APPROVED PILOT LADDER.
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Lifesaving
Issued 9 October 1988 Resolved
REPROVISION, SERVICE AND PROPERLY STATION APPROVED LIFERAFTS.
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Construction/Loadline
Issued 9 October 1988 Resolved
PROVIDE FOR INSPECTION AND TESTING OF HULL AND DECK FITTINGS AS FOLLOWS: VALVES AND CONTROLS FOR BILGE WELLS, COFFERDAMS AND SUCTIONS; DECK OPENING/CLOSURES; CARGO GEAR, WATERTIGHT DOORS AND SIDEPORTS.
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Accommodation/Occupational Safety
Issued 9 October 1988 Resolved
PROVIDE HOSPITAL AND FIRST AID EQUIPMENT.
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Lifesaving
Issued 9 October 1988 Resolved
CONDUCT FIRE AND BOAT DRILLS IN PRESENCE OF USCG MARINE INSPECTOR.
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Lifesaving
Issued 9 October 1988 Resolved
CONDUCT WEIGHT TESTS OF LIFEBOATS AND LIFEBOAT DAVITS.
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Fire Fighting
Issued 9 October 1988 Resolved
PROVIDE ADITIONAL FIRE CONTROL PLAN TO BE STORED PERMANETLY AND PROMINENTLYMARKED IN A WEATHER TIGHT ENCLOSURE OUTSIDE THE DECKHOUSE.
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Fire Fighting
Issued 9 October 1988 Resolved
PRESSURE TEST ALL REQUIRED AND SPARE FIRE HOSES AND OUTFIT FIRE STATIONS.
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Engineering
Issued 9 October 1988 Resolved
TEST OPERATION OF MAIN PROPULSION SAFETY DEVICES.
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Engineering
Issued 9 October 1988 Resolved
MAKE PORT AND STARBOARD BOILERS AVAILABLE FOR EXAMINATION OF FIRESIDES AND WATERSIDES.
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Engineering
Issued 9 October 1988 Resolved
CONDUCT HYDROSTATIC TEST OF EACH BOILER FOR CREDIT AND REQUIRED MAIN AND AUXILIARY STEAM PIPING.
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Engineering
Issued 9 October 1988 Resolved
SET AND SEAL STEAM DRUM AND SUPERHEATER SAFETY VALVES.
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Engineering
Issued 9 October 1988 Resolved
PROVE SETTING OF RELIEF VALVES ON ALL PRESSURE VESSELS.
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Engineering
Issued 9 October 1988 Resolved
PROVE OPERATION OF BILGE PUMPS, ANY REMOTE START OR STOP SWITCHES AND TEST OILY WATER SEPARATOR.
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Accommodation/Occupational Safety
Issued 9 October 1988 Resolved
PROVE OPERATION OF AIR COMPRESSORS, AIR CONDITIONING AND REFRIGERATION SYSTEMS.
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Engineering
Issued 9 October 1988 Resolved
PROVE OPERATION OF DISTILLING PLANT AND POTABLE WATER PUMPS.
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Engineering
Issued 9 October 1988 Resolved
PROVE OPERATION OF LUBE OIL SERVICE PUMPS.
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Electrical
Issued 9 October 1988 Resolved
TEST OPERATION OF SERVICE GENERATORS-INCLUDING OVERSPEED TRIPS, LOW LUBE OIL PRESSURE TRIPS, LOW LUBE OIL PRESSURE ALARMS REVERSE POWER TRIPS, PARALLEL OPERATION AND VOLTAGE REGULATION.
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Electrical
Issued 9 October 1988 Resolved
TEST GROUND FAULT DETECTORS ON MAIN AND EMERGENCY SWITCHBOARDS.
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Electrical
Issued 9 October 1988 Resolved
PROVE PROPER OPERATION OF EMERGENCY BATTERIES AND THEIR CHARGING SYSTEMS.
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Accommodation/Occupational Safety
Issued 9 October 1988 Resolved
PROVE OPERATION OF REQUIRED MARINE SANITATION DEVICE.
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Navigation
Issued 9 October 1988 Resolved
PROVE OPERATION OF ENGINE ORDER TELEGRAPH, EOT FAILURE ALARM AND 1JV PHONE CIRCUIT.
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Lifesaving
Issued 9 October 1988 Resolved
PROVE LIFEBOAT WINCHES INCLUDING LIMIT SWITCHES, MASTER SWITCH AND EMERGENCY DISCONNECT.
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Fire Fighting
Issued 9 October 1988 Resolved
TEST REMOTE SHUTDOWNS FOR ENGINEROOM VENTILATION, FORCED DRAFT FANS, FUEL OIL PUMPS AND CARGO SPACE FANS.
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Electrical
Issued 9 October 1988 Resolved
REPLACE ALL MISSING LIGHTS, GUARD AND GLOBES.
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Documentation
Issued 9 October 1988 Resolved
PROVIDE OIL TRANSFER PROCEDURES AND OIL RECORD BOOK.
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Engineering
Issued 9 October 1988 Resolved
REBRICK THE FRONT WALL ON THE PORT AND STARBOARD BOILERS.
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Fire Fighting
Issued 9 October 1988 Resolved
PROVE OPERATION OF ALL FIRE PUMPS AND RELIEF VALVES.
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Construction/Loadline
Issued 9 October 1988 Resolved
REPLACE OR REPAIR THE HOLED PIPING AT THE PORT SIDE AFT CORNER OF THE NUMBER 3 CARGO HOLD UPPER & T'WEEN DECK
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Construction/Loadline
Issued 9 October 1988 Resolved
REPAIR OR REPLACE THE HOLED PIPING IN THE PORT AFT CORNER OF NR. 6 CARGO HOLD, UPPER & T'WEEN DECK
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Fire Fighting
Issued 9 October 1988 Resolved
RENEW THE ENGINEROOM CO2 SIREN PIPING WHICH HAS BEEN TERMINATED AT THE STARBOARD AFT BULKHEAD OF THE MIDSHIPS HOUSE AND TEST TO THE SATISFACTION OF A COAST GUARD INSPECTOR.
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Construction/Loadline
Issued 9 October 1988 Resolved
OPEN DOUBLE BOTTOM FUEL OIL TANKS FOR INSPECTION IN ACCORDANCE WITH 46 CFR 91.43 WITHIN 60 DAYS AFTER ACTIVATION OF THE VESEL AND PRIOR TO RETURN TO LAY-UP STATUS.
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Construction/Loadline
Issued 9 October 1988 Resolved
RENEWED KEEL PLATES FK13 AND FK14. ORIGINAL THICKNESS WAS .831 OR 33.9#. NEW PLATE IS 7/8 OR 35.7#.
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Construction/Loadline
Issued 9 October 1988 Resolved
RENEWED APPROXIMATELY 70 PERCENT OF AFT PEAK COMPARTMENT INTERNALS INCLUD-ING ALL UNDER DECK BEAMS, UPPER LONGITUDINAL DEEP WEBS, PORT SIDE PUMP ROOMBULKHEAD AND PORTIONS OF SIDE FRAMES.
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Construction/Loadline
Issued 9 October 1988 Resolved
RENEWED 2ND DECK PLATES C15 PORT AND STBD, B5 PORT AND STBD, A33 PORT & STBD AND A34 PORT & STBD. ORIGINAL 14.7# OR .363 WAS REPLACED WITH 3/8 INCHOR 15.3# PLATE.
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Lifesaving
Issued 9 October 1988 Resolved
PROVIDE APPROVED LIFESAVING EQUIPMENT, AS REQUIRED, INCLUDING: LIFEBOAT PROVISIONS, LIFE PRESERVERS, RINGBUOYS, LINE THROWING APPARATUS, LIFEBOAT RADIO, EPIRB AND EXPOSURE SUITS.
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Fire Fighting
Issued 9 October 1988 Resolved
PROVIDE ALL REQUIRED FIRE PROTECTION EQUIPMENT AND SERVICING FOR FIXED, SEMI-PORTABLE AND PORTABLE EXTINGUISHING SYSTEMS AND SMOKE DETECTION SYSTEMS.
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Unknown
Issued 9 October 1988 Resolved
PROVIDE FOR INSPECTION OF ALL EMERGENCY EQUIPMENT.
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988
Accommodation/Occupational Safety
Issued 9 October 1988 Resolved
INSPECT AND TEST REMOTE CONTROLS TO POWER VENTILATION AND MECHANICAL VENT CLOSURES.
Condition: Unknown
Due 9 October 1988
Resolved 9 October 1988

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.