MAURY USCG vessel records Sign in
← All vessels

SNOWGOOSE III

SNOWGOOSE III is a 1996 passenger vessel (inspected). The Coast Guard has recorded 41 inspections since 1997, most recently in July 2025, along with 27 deficiencies, 1 operational control, 1 with no removal date recorded and 1 casualty investigation in 2004.

Records from 1997 to 2025. Most recent: inspection, 18 July 2025.

Built
1996
Last inspected
18 July 2025
Documentation
Case Pending · documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

WCY9853
441176
Flag
UNITED STATES
367393430
Maury page id
psix-441176

Inspections, by type

…with no type recorded12
Years with a record 25 calendar years (1997–2025)
The 41 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)42.1 ft × 15.5 ft × 8.0 ft
Registered tonnagegross 34 / net 27
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderH&H MARINE INC · MILBRIDGE, ME, UNITED STATES · built 1996
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portBREMEN, ME
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationCase Pending · issued 27 January 2025 · expires 31 January 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it34 - Simplified, Gross Ton
27 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCY9853MMSI 367393430 · active · compulsorily equipped · granted 6 April 2019, expires 9 April 2029 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 41

18 July 2025 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8191184
29 April 2025 Drydock Exam · Internal Structural Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8123867
28 May 2024 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7931716
15 June 2023 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7718372
11 April 2023 Drydock Exam · Internal Structural Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7667280
10 May 2022 COI Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7442288
5 May 2021 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7191119
15 September 2020 Internal Structural Exam · Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7058292
10 May 2019 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6692984
4 October 2018 Drydock Exam · Internal Structural Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6566413
8 May 2018 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6449421
11 May 2017 Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6121577
12 October 2016 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5999800
11 January 2016 Administrative Inspection · Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5863581
5 January 2016 Plan Review "T" Boat · Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5803655
22 December 2015 Plan Review "T" Boat · Construction Oversight · Administrative Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5786130
30 October 2014 Administrative Inspection · Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5014812
6 May 2014 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 4858248
11 May 2012 COI Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 4308560
19 October 2010 Hull Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3873062
31 October 2008 Hull Examination · Internal Structural Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3414809
16 June 2008 Re-Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3239089
9 May 2007 COI Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2925816
25 October 2006 Hull Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2807773
12 May 2006 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2647650
28 April 2005 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2344694
1 September 2004 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2183339
30 August 2004 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2181817
30 August 2004 Type not recorded
No type recorded · Station Boothbay Harbor · USCG Northeast District (CGD-NE) · Activity 2181853
17 August 2004 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2168956
23 May 2003 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1799652
9 May 2003 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1789821
29 May 2002 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1622497
22 May 2001 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1061864
22 May 2001 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1068424
17 May 2000 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1365765
28 August 1999 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 28124
17 May 1999 Plan Review "T" Boat · Initial Construction-Excluding Oversight · Initial Certification · Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1426215
30 March 1999 Type not recorded
No type recorded · Station Portsmouth Harbor · USCG Northeast District (CGD-NE) · Activity 1506393
2 August 1997 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 122433
4 March 1997 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 89406

Deficiency record · 27

11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 28 May 2024 Resolved
Secure paddles in life floats.
Due 11 June 2024
Resolved 5 June 2024
Resolution: Paddles secured.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 28 May 2024 Resolved
Lengthen painters on life floats so they can be manually deployed.
Due 11 June 2024
Resolved 6 June 2024
Resolution: Painters properly lengthened.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 28 May 2024 Resolved
Provide DAPI enrollment form.
Due 11 June 2024
Resolved 25 June 2024
Resolution: DAPI enrollment provided.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (air intake)
Issued 6 May 2014 Resolved
Troubleshoot and repair main propulsion engine as determined by servicing report.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2014
Resolved 13 May 2014
Resolution: Received service report detailing repair.
Engineering › Diesel Engine (propulsion-reduction gear) › Air Silencer
Issued 19 October 2010 Resolved
Install chaffing gear on the Air Sep discharge line.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 May 2011
Resolution: Chaffing gear installed.
Engineering › Diesel Engine (propulsion-reduction gear) › Waste Heat Recovery
Issued 19 October 2010 Resolved
Replace the chaffed wasted hose on the heat exchanger.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 May 2011
Resolution: Hose replaced.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (electric)
Issued 19 October 2010 Resolved
Adjust or replace the Alternator belt.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 May 2011
Resolution: Alternator belt tightened.
Engineering › Lubricating Oil Storage/Transfer System › Hose
Issued 19 October 2010 Resolved
Install chaffing gear on hydraulic hose on front of the main diesel engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 May 2011
Resolution: Chaffing gear installed.
Engineering › Sea-water System (primary cooling) › Piping
Issued 19 October 2010 Resolved
Install double hose clamps to the raw water lines.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 May 2011
Resolution: Corrected.
Construction/Loadline › Hull › Side Shell
Issued 19 October 2010 Resolved
Repair fracture on the entry way deck on the stern.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 11 May 2011
Resolution: Repaired satisfactory.
Construction/Loadline › Penetrations › Bottom Plug
Issued 19 October 2010 Resolved
Install resin/paint to the water relief stringer holes to avoid encapsulated stringer wood rot.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 11 May 2011
Resolution: Repaired satisfactory.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 23 May 2003 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 May 2003
Resolved 18 August 2004
Resolution: OWNER HIRES A NEAR COASTAL OPERATOR WHEN VESSEL OPERATES BEYOND BOUNDRY LINE
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 23 May 2003 Resolved
RENEW FUEL TANK FOR HEATER IAW T-BOAT REGS, PRIOR TO USING HEATER. LEGACY COMPONENT DESC: Tank
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 23 May 2003
Resolved 18 August 2004
Resolution: OWNER OPERATOR REMOVED FUEL TANK FROM VESSEL AND DECIDED TO HEATER SYSTEM WAS NOT NEEDED AT THIS TIME.
Documentation
Issued 22 May 2001 Resolved
PROVIDE COPY OF RADIO OPERATORS PERMIT.
Condition: Unknown
Due 15 June 2001
Resolved 12 June 2001
Lifesaving
Issued 22 May 2001 Resolved
INSPECT EPIRB IAW OWNERS MANUAL AND PROVIDE DOCUMENTATION OF COMPLETION.
Condition: Unknown
Due 22 May 2001
Resolved 17 July 2001
Documentation
Issued 22 May 2001 Resolved
PROVIDE COPY OF FCC SAFETY CERTIFICATE.
Condition: Unknown
Due 15 June 2001
Resolved 12 June 2001
Documentation
Issued 22 May 2001 Resolved
PROVIDE COPY OF CHEMICAL TESTING PROGRAM CONSORTIUM AUDIT.
Condition: Unknown
Due 15 June 2001
Resolved 12 June 2001
Fire Fighting
Issued 22 May 2001 Resolved
INSPECT FIXED FIRE FIGHTING SYSTEM IAW OWNERS MANUAL AND PROVIDE DOCUMENTATION THAT INSPECTION IS COMPLETE.
Condition: Unknown
Due 22 May 2001
Resolved 12 June 2001
Lifesaving
Issued 17 May 2000 Resolved
RENEW WATER LIGHT BATTERIES & ENSURE PROPER OPERATION OF LIGHTS.
Condition: Unknown
Due 24 May 2000
Resolved 19 July 2000
Lifesaving
Issued 17 May 2000 Resolved
ADD (1) DAY ORANGE SMOKE FLARE TO MAKE THE TOTAL NUMBER REQUIRED = 6.
Condition: Unknown
Due 17 May 2000
Resolved 19 July 2000
Construction/Loadline
Issued 17 May 2000 Resolved
REMOVE GELCOAT & 1ST LAYER OF CHOPPED FIBERGLASS THAT IS BROKEN/CRACKED AROUND THE RUDDER POST; FAIR BACK INCLUDING THE BEDDING COMPOUND TO MAKE AVAILABLE FOR FURTHER INSPECTION.
Condition: Unknown
Due 17 May 2000
Resolved 19 July 2000
Lifesaving
Issued 17 May 1999 Resolved
Vessel is restricted to 39 people on board until a total of 51 life jacketsare placed on board.
Condition: Unknown
Due 24 May 1999
Resolved 24 May 1999
Accommodation/Occupational Safety
Issued 17 May 1999 Resolved
Fix accomodation light.
Condition: Unknown
Due 24 May 1999
Resolved 24 May 1999
Navigation
Issued 17 May 1999 Resolved
Correct charts up to NTM 18/99.
Condition: Unknown
Due 19 June 1999
Resolved 19 June 1999
Navigation
Issued 17 May 1999 Resolved
Place a bell on board.
Condition: Unknown
Due 19 June 1999
Resolved 19 June 1999
Engineering
Issued 17 May 1999 Resolved
Make repairs to RPM gauge at pilot station.
Condition: Unknown
Due 7 July 1999
Resolved 1 September 1999
Lifesaving
Issued 17 May 1999 Resolved
Vessel is required primary lifesaving life floats. There are currently 3 BA's on board for a total of 52 people. Replace with Life floats by 17 JUN1999.
Condition: Unknown
Due 19 June 1999
Resolved 19 June 1999

Casualty record · 1

30 August 2004Routine · role: Involved in a Marine Casualty · 2 injured · activity 2181817
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.