← All vessels
JANE
JANE is a 1971 towing vessel. The Coast Guard has recorded 22 inspections since 1996, most recently in January 2006, along with 129 deficiencies — 59 with no resolution recorded — and 5 operational controls.
Records from 1996 to 2006. Most recent: inspection, 30 January 2006.
- Built
- 1971
- Last inspected
- 30 January 2006
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 129 recorded · 59 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
V2Y04
441215
Flag
VIRGIN ISLANDS, BRITISH
—
Maury page id
psix-441215
Inspections, by type
…with no type recorded14
…past their stated due date15
Years with a record
8 calendar years (1996–2006)
The 22 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it143 - Simplified, Gross Ton
56 - Simplified, Net Ton
56 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 22
30 January 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2575778
23 August 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2173931
22 November 2002
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1710435
20 September 2002
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1678400
11 September 2002
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1674704
9 September 2002
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1673405
4 September 2002
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1671044
12 February 2002
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1485761
13 December 2001
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1476618
16 November 2001
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 295605
3 November 2001
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 295252
3 July 2001
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 638005
29 June 2001
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 291475
29 June 2001
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 291598
31 December 2000
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 638004
20 March 2000
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 276196
1 April 1999
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 755291
31 March 1999
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 207884
19 September 1997
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 408022
28 May 1997
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 404225
24 June 1996
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 392631
28 May 1996
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 391700
Deficiency record · 129
Fire Fighting
Issued 21 September 2002
Resolved
Make permanent repairs to the fixed fire fighting system. Until permanently repaired, the engine room is to be manned continuously with personnel equipped to extinguish a fire and a means to communicate.
Pollution Prevention/Response
Issued 11 September 2002
No resolution recorded
Prove proper operation of the ships MSD.
Documentation
Issued 11 September 2002
No resolution recorded
Provide a copy of the ship's plans iaw ccssc 1.8.
Engineering
Issued 9 September 2002
No resolution recorded
Renew forepeak vent.
Electrical
Issued 9 September 2002
No resolution recorded
Properly dead end electrical cables vicinity of the forepeak.
Construction/Loadline
Issued 9 September 2002
No resolution recorded
Make repairs to fractures in coaming in the vicinity of starboard engine room hatch.
Engineering
Issued 9 September 2002
No resolution recorded
Make starboard steering pin available for inspection.
Fire Fighting
Issued 9 September 2002
No resolution recorded
Demonstrate operation of the emergency fire pump.
Lifesaving
Issued 9 September 2002
No resolution recorded
Renew PFD lights and whistles iaw CCSSC supplement.
Navigation
Issued 9 September 2002
No resolution recorded
Provide tow gear quick release iaw CCSSC 2.10.1
Engineering
Issued 9 September 2002
No resolution recorded
Renew diesel tank sight glass.
Electrical
Issued 9 September 2002
Resolved
Make repairs to electrical cables behind switchboard front.
Pollution Prevention/Response
Issued 9 September 2002
No resolution recorded
Provide evidence of compliance with 33 CFR 155.420, (pumping, piping and discharge requirements)
Engineering
Issued 9 September 2002
No resolution recorded
Provide overspeed protection iaw CCSSC 2.24.3
Engineering
Issued 9 September 2002
No resolution recorded
Provide auto shut down as required by CCSSC 2.24.6
Engineering
Issued 9 September 2002
No resolution recorded
Provide controls required by CCSSC 2.25
Engineering
Issued 9 September 2002
No resolution recorded
Provide indication of rotation direction on bridge. (CCSSC 2.37.1.8.1)
Engineering
Issued 9 September 2002
No resolution recorded
Provide starting air low pressure alarm.
Fire Fighting
Issued 9 September 2002
No resolution recorded
Provide fixed fire detection and alarm iaw CCSSC 3.16.7.
Fire Fighting
Issued 5 September 2002
No resolution recorded
Make proper repairs to fire main.
Navigation
Issued 5 September 2002
No resolution recorded
Provide signaling lamp.
Personnel
Issued 5 September 2002
No resolution recorded
Crew vessel iaw safe manning document.
Construction/Loadline
Issued 5 September 2002
No resolution recorded
Provide evidence of drydock completion.
Navigation
Issued 5 September 2002
No resolution recorded
Update deviation table for magnetic compass.
Lifesaving
Issued 5 September 2002
No resolution recorded
Renew distress signals.
Accommodation/Occupational Safety
Issued 5 September 2002
No resolution recorded
Remove electical wiring from Master's shower.
Accommodation/Occupational Safety
Issued 5 September 2002
No resolution recorded
Renew crew's shower bulkhead.
Stability
Issued 5 September 2002
No resolution recorded
Provde flag approved stability letter.
Fire Fighting
Issued 5 September 2002
No resolution recorded
Make repairs and prove operations of the engine room fire detectors.
Deck/Cargo
Issued 5 September 2002
No resolution recorded
Provide anchors for vessel.
Fire Fighting
Issued 5 September 2002
No resolution recorded
Provide fire control plan.
Pollution Prevention/Response
Issued 5 September 2002
No resolution recorded
Provide oil transfer procedures iaw 33 C.F.R. 155.
Engineering
Issued 5 September 2002
No resolution recorded
Make repairs to the generator voltage control.
Fire Fighting
Issued 5 September 2002
No resolution recorded
Renew starboard engine room vent.
Personnel
Issued 5 September 2002
No resolution recorded
Provide crew documents and medical certificates.
Personnel
Issued 5 September 2002
No resolution recorded
Provide a second engineer, with license, iaw safe manning cert.
Lifesaving
Issued 5 September 2002
No resolution recorded
Replace battery in ship's EPIRB.
Lifesaving
Issued 5 September 2002
No resolution recorded
Replace hydrostatic release in ship's EPIRB.
Navigation
Issued 5 September 2002
No resolution recorded
Provide MF radio iaw CCSSC Certificate.
Navigation
Issued 5 September 2002
No resolution recorded
Replace bulbs in navigation and deck lights with approved marine type bulbs.
Lifesaving
Issued 5 September 2002
No resolution recorded
Service both ship's liferafts iaw CCSSC certificate.
Lifesaving
Issued 5 September 2002
No resolution recorded
Provide proper arrangement for liferaft hydrostatic release.
Navigation
Issued 5 September 2002
No resolution recorded
Update ship's charts.
Fire Fighting
Issued 4 September 2002
Resolved
Make repairs and prove operation of the fire pump.
Engineering
Issued 4 September 2002
No resolution recorded
Make repairs and prove operation of the #1 SSGEN overspeed device.
Engineering
Issued 4 September 2002
No resolution recorded
Make repairs and prove operation of the #2 SSGEN overspeed device.
Accommodation/Occupational Safety
Issued 4 September 2002
No resolution recorded
Properly secure #2 SSGEN starting battery.
Accommodation/Occupational Safety
Issued 4 September 2002
No resolution recorded
Prior to use, make repairs to STBD aft bollard.
Electrical
Issued 4 September 2002
No resolution recorded
Renew light covers as needed thorughout the vessel.
Fire Fighting
Issued 4 September 2002
No resolution recorded
Make repairs to the fixed fire fighting system.
Lifesaving
Issued 4 September 2002
No resolution recorded
Renew STBD side aft life ring retro-reflective tape.
Navigation
Issued 4 September 2002
No resolution recorded
Clean aft navigation light.
Accommodation/Occupational Safety
Issued 4 September 2002
No resolution recorded
Remove propane, oxy-acetelene tanks from vessel or properly stow and secure.
Construction/Loadline
Issued 4 September 2002
No resolution recorded
Renew engine room rails, upper level.
Engineering
Issued 4 September 2002
Resolved
Renew remote fuel shut-offs for engine room.
Accommodation/Occupational Safety
Issued 4 September 2002
Resolved
Renew light covers as needed throughout the vessel.
Electrical
Issued 4 September 2002
No resolution recorded
Replace electrical outlets as necessary throughout vessel.
Construction/Loadline
Issued 4 September 2002
No resolution recorded
Renew knife edge on port and starboard wheelhouse watertight doors.
Navigation
Issued 4 September 2002
No resolution recorded
Provide deviation table for magnetic compass.
Navigation
Issued 4 September 2002
No resolution recorded
Properly wire SSB radio.
Electrical
Issued 4 September 2002
No resolution recorded
Properly label ship's engine telegraph with the direction of screw.
Navigation
Issued 4 September 2002
No resolution recorded
Provide ship's radio station license..
Stability
Issued 4 September 2002
No resolution recorded
Provide stability book.
Accommodation/Occupational Safety
Issued 4 September 2002
No resolution recorded
Clean grease trap under galley hood.
Construction/Loadline
Issued 3 November 2001
Resolved
Prior to departing St Thomas, make installed secondary bilge pump operational.
Fire Fighting
Issued 3 November 2001
Resolved
Prior to departing St Thomas, provide operational emergency fire pump.
Fire Fighting
Issued 3 November 2001
Resolved
Prior to departing St Thomas, conduct fire and abandon ship drills to the satisfaction of the attending marine inspector.
Fire Fighting
Issued 3 November 2001
Resolved
prior to departing St Thomas, provide operational fixed fire detection system.
Documentation
Issued 3 November 2001
Resolved
Prior to departing St Thomas, provide a valid loadline certificate.
Deck/Cargo
Issued 3 November 2001
Resolved
Prior to departing St Thomas, provide a suitable anchoring system IAW CCSSC2.9.
Documentation
Issued 3 November 2001
Resolved
Prior to departing St Thomas, provide a valid safety radio certificate.
Navigation
Issued 3 November 2001
Resolved
Prior to departing St Thomas, make operational SBB high frequency radio IAWCCSSC 5.9.
Electrical
Issued 3 November 2001
Resolved
Prior to departing St Thomas, provide a suitable starting arrangement for the ships electrical generators IAW CCSSC 2.33
Navigation
Issued 3 November 2001
Resolved
Prior to returning to U.S. waters, provide current navigation publications.
Documentation
Issued 3 November 2001
Resolved
Prior to returing to U.S. waters, provide original chief engineers license.
Navigation
Issued 3 November 2001
Resolved
Prior to returning to U.S. waters, provide current magnetic compass deviation table.
Fire Fighting
Issued 3 November 2001
Resolved
Repair soft patch on overboard discharge in E/R starboard side.
Lifesaving
Issued 3 November 2001
Resolved
Prior to returning to U.S. waters, provide 6 liferings IAW CCSSC 4.12.
Navigation
Issued 3 November 2001
Resolved
Prior to returning to U.S. waters, provide operational navigation lights.
Electrical
Issued 3 November 2001
Resolved
Prior to returing to U.S. waters, make port ship service generator operable.
Fire Fighting
Issued 3 November 2001
Resolved
Properly attach CO2 discharge piping in engine room.
Navigation
Issued 3 November 2001
Resolved
Properly mount hydraulic lines to steering gear system to the satisfaction of the designated flag state surveyor.
Navigation
Issued 3 November 2001
Resolved
Prior to returing to U.S. waters, conduct repairs to port rudder assembly for excessive movement to the satisfaction of a class society surveyor designated by flag state administration.
Lifesaving
Issued 3 November 2001
Resolved
Prior to returing to U.S. waters, install weak-link on six man liferaft.
Navigation
Issued 3 November 2001
Resolved
Prior to returning to U.S. waters, repair leaks to steering gear hydraulic actuators seals to the satisfaction of a class society surveyor designated by the flag state administration.
Construction/Loadline
Issued 3 November 2001
Resolved
Replace missing dog on WTD main deck, port side galley entrance.
Electrical
Issued 3 November 2001
Resolved
Provide cover plate for electrical junction box in E/R port side forward.
Electrical
Issued 3 November 2001
Resolved
Properly mount emergency batteries in battery box.
Lifesaving
Issued 3 November 2001
Resolved
Properly mount oxy-propane cutting rig on fantail with metal strapping.
Lifesaving
Issued 3 November 2001
Resolved
Register EPRIB with appropriate agency.
Fire Fighting
Issued 29 June 2001
Resolved
MAKE PROPER REPAIRS TO FIXED FIRE FIGHTING TO MACHINERY SPACE TO THE SATISFACTION OF FLAG_x001C_ CONDUCT ANNUAL SERVICING OF SHIPS PORTABLE FIRE EXTINGUISHERS
Navigation
Issued 29 June 2001
Resolved
CHARTS WERE NOT UPDATED TO REFLECT CURRENT CORRECTIONS _x001C_ _x001C_
Navigation
Issued 20 March 2000
Resolved
CONDUCT REPAIRS TO PORT RUDDER ASSEMBLY FOR EXCESSIVE MOVEMENT TO THE SATISFACTION OF A CLASS SOCIETY SURVEYOR DESIGNATED BY THE FLAG ADMINISTRATION.
Fire Fighting
Issued 20 March 2000
Resolved
PROPERLY MOUNT ALL FIRE EXTINGUISHERS ON BOARD ( NO TIE DOWNS ).
Navigation
Issued 20 March 2000
Resolved
REPAIR LEAKS TO STEERING GEAR HYDRAULIC ACTUATORS SEALS TO THE SATISFACTIONOF A CLASS SOCIETY SURVEYOR DESIGNATED BY THE FLAG ADMINISTRATION.
Electrical
Issued 20 March 2000
Resolved
PROVIDE INSULATED RUBBER MAT TO ENGINE ROOM POWER DISTRIBUTION PANEL.
Fire Fighting
Issued 20 March 2000
Resolved
PROVIDE PROPER FIRE HOSE NOZZLES TO ALL FIRE STATIONS._x001C_ PRIOR RO DEPARTURE.
Lifesaving
Issued 20 March 2000
Resolved
PROVIDE SIX LIFEJACKETS W/LTS AND WHISTLES.
Fire Fighting
Issued 20 March 2000
Resolved
REPAIR AND CONDUCT FUNCTION TEST OF MAIN FIRE PUMP._x001C_ PRIOR TO DEPARTURE.
Construction/Loadline
Issued 20 March 2000
Resolved
REMOVE OILY WATER MIXTURE FROM BILGES TO A PROPER FACILITY AND PROVIDE RECERPT OF SERVICE._x001C_ PRIOR TO DEPARTURE.
Lifesaving
Issued 20 March 2000
Resolved
PROVIDE A CURRENT CERTIFIED LIFERAFT PRIOR TO DEPARTURE.
Navigation
Issued 20 March 2000
Resolved
PROPERLY MOUNT HYDRAULIC LINES TO STEERING GEAR SYSTEM AFT TO THE SATISFACTION OF CLASS SOCIETY SURVEYOR DESIGNATED BY THE FLAG ADMINISTRATION.
Fire Fighting
Issued 20 March 2000
Resolved
PROVIDE PROPER FIRE HOSE'S FOR FIRE MAIN SYSTEMS ON DECK._x001C_ PRIOR TO DEPARTURE.
Fire Fighting
Issued 20 March 2000
Resolved
REPAIR VALE HANDLE TO STARBOARD FIRE MAIN ON DECK._x001C_ PRIOR TO DEPARTURE.
Documentation
Issued 20 March 2000
Resolved
PROVIDE CARIBBEAN CARGO SHIP SAFETY CODE CERTIFICATE PRIOR TO OPERATING IN U.S. PORTS TO ENSURE COMPLIANCE.
Lifesaving
Issued 20 March 2000
Resolved
PROVIDE THREE NEW FLARES PRIOR TO ENTRY OF NEXT U.S. PORT.
Lifesaving
Issued 20 March 2000
Resolved
PROVIDE ONE RING BUOY LIGHT PRIOR TO NEXT U.S. PORT.
Navigation
Issued 20 March 2000
Resolved
CONDUCT REPAIRS TO STEERING GEAR SYSTEM ATTACHMENT POINTS AFT TO TILLER ARM, HYDRAULIC ACTUATIORS MOUNTING POINTS TO THE SATISFACTION OF A CLASS SOCIETY SURVEYOR DESIGNATED BY THE FLAG STATE ADMINISTRATION.
Navigation
Issued 20 March 2000
Resolved
PROVIDE THE FOLLOWING PUBLIATION PRIOR TO DEPARTURE, CHARTS FOR U.S. WATERSFOR TRANSIT ROUTE, TIDE TABLE, NAVIGATION RULES.
Navigation
Issued 20 March 2000
Resolved
PROVIDE A SHIPS HORN PRIOR TO ENTRY INTO U.S. PORT.
Lifesaving
Issued 28 May 1997
Resolved
ENSURE LIFEBOUYS ARE FITTED WITH RETRO-REFLECTIVE TAPE.
Lifesaving
Issued 28 May 1997
Resolved
ENSURE VESSEL HAS EPIRB ONBOARD MEETING REQUIREMENTS OF 46 C.F.R. 25.26.
Unknown
Issued 28 May 1997
Resolved
ENSURE PLASTICS ARE PROPERLY DISPOSED OF. (INCLUDING ASH/MELTED PLASTICS)
Documentation
Issued 28 May 1997
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Accommodation/Occupational Safety
Issued 28 May 1996
Resolved
VESSEL HAS NO MARINE SANITATION DIVICE
Electrical
Issued 28 May 1996
Resolved
STBD GENERATOR INOPERABLE
Fire Fighting
Issued 28 May 1996
Resolved
VESSEL HAS NO SERVICEABLE FIRE EXTINGUISHERS
Accommodation/Occupational Safety
Issued 28 May 1996
Resolved
VESSEL HAS NO OIL POLLUTION PLACARD
Navigation
Issued 28 May 1996
Resolved
VESSEL WHISTLE INOPERABLE
Fire Fighting
Issued 28 May 1996
Resolved
DIESEL DRIVEN FIRE PUMP INOPERABLE
Electrical
Issued 28 May 1996
Resolved
ELECTRICAL WIRES EXPOSED IN ENGINE ROOM
Fire Fighting
Issued 28 May 1996
Resolved
FIRE HOSES NOT EQUIPED WITH PROPER COUPLINGS
Construction/Loadline
Issued 28 May 1996
Resolved
EXCESSIVE OIL IN BILGES _x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 28 May 1996
Resolved
VESSEL MISSING TWO DAY NIGHT FLARES
Navigation
Issued 28 May 1996
Resolved
NO DEVIATION TABLE FOR MAGNETIC COMPASS
Navigation
Issued 28 May 1996
Resolved
NO NAVIGATION PUBLICATIONS ONBOARD
Navigation
Issued 28 May 1996
Resolved
RUDDER ANGLE IDICATOR INOPERABLE
Lifesaving
Issued 28 May 1996
Resolved
HAZARDOUS MATERIAL IMPROPERLY STOWED IN FORPEAK
Navigation
Issued 28 May 1996
Resolved
NO CHART OF LOCAL AREA_x001C_
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.