CARLYN

CARLYN is a 1996 passenger vessel (inspected). The Coast Guard has recorded 58 inspections since 1996, most recently in June 2026, along with 59 deficiencies, 1 operational control and 4 casualty investigations between 2008 and 2013.

Records from 1996 to 2026. Most recent: inspection, 8 June 2026.

Built
1996
Last inspected
8 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD6467
441229
Flag
UNITED STATES
367150000
Maury page id
psix-441229

Inspections, by type

…with no type recorded6
Years with a record 29 calendar years (1996–2026)
The 58 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)61.0 ft × 14.0 ft × 6.8 ft
Registered tonnagegross 28 / net 25
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSCARANO BOAT BUILDING INC · ALBANY, NY, UNITED STATES · built 1996
Hull materialWood
PropulsionAuxiliary Sail
Hull shapeSail (Distinct Keel)
Hull configurationMonohull
Hailing portDEER HARBOR, WA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 8 June 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it28 - Simplified, Gross Ton
25 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ4595MMSI 367150000 · active · compulsorily equipped · granted 25 March 2017, expires 25 March 2027
WDD6467MMSI 367150000 · terminated · compulsorily equipped · granted 15 March 2007, cancelled 16 March 2017
WCW8224MMSI not assigned · expired · voluntarily equipped · granted 21 August 1996, cancelled 21 October 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 58

8 June 2026 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8345973
19 October 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8255165
15 September 2025 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8253666
14 February 2024 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7948251
18 September 2023 Annual Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7795938
6 September 2022 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7553069
13 July 2022 Excursion Permit
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7505987
13 April 2022 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7430615
18 March 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7414407
19 October 2021 COI Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7335576
28 October 2020 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7086368
12 March 2020 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6925345
15 November 2019 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6862526
1 October 2019 Annual Inspection · In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6824542
11 September 2019 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6809492
7 September 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6534924
10 August 2018 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6507533
6 April 2018 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6392453
25 October 2017 Special · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6292270
18 October 2017 Annual Inspection · DAPI Audit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6289752
31 October 2016 COI Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6032768
3 September 2015 Annual Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5721027
30 October 2014 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5013002
6 December 2011 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4203091
6 December 2011 Internal Structural Exam · Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4203191
9 February 2011 DAPI Audit
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3942889
4 March 2010 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3689726
5 January 2010 Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3653708
2 July 2009 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3521643
2 July 2009 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3526202
6 May 2009 Type not recorded
No type recorded · USCGC SWORDFISH (WPB 87358) · USCG Northwest District (CGD-NW) · Activity 3478037
20 March 2009 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3436262
20 March 2009 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3438725
20 September 2008 Type not recorded
No type recorded · Station Seattle · USCG Northwest District (CGD-NW) · Activity 3328528
19 September 2008 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3328512
19 September 2008 Damage Survey · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3330747
20 March 2008 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3168851
16 January 2008 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3131721
14 December 2007 Hull Examination · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3115762
15 March 2007 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2888841
26 July 2006 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2725550
13 March 2006 Annual Inspection · Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2636275
23 March 2005 Examination of Repairs · Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2318020
1 April 2004 Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2035390
7 October 2003 Internal Structural Exam · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2003066
28 March 2003 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1764681
15 April 2002 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1605098
16 November 2001 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1415723
21 August 2001 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1399710
31 May 2000 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1386810
1 March 2000 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1415315
1 June 1999 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1402884
3 July 1998 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1454581
20 March 1998 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 775729
10 March 1998 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1455563
27 July 1997 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 781401
3 July 1996 Initial Certification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1404222
19 April 1996 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1095448

Deficiency record · 59

01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 15 September 2025 Resolved
The vessel's COI was invalidated on January 26, 2025 after not completing the vessel's Annual COI inspection within 90 days of the COI anniversary date. The vessel continued to operate with an invalid COI. Violation Cite 46 CFR 176.100(a)
Action required: 10 - Deficiency Rectified
Due 15 September 2025
Resolved 15 September 2025
Resolution: Issued LOW.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 October 2021 Resolved
Vessel unable to get underway to conduct man overboard and abandon ship drills. CITE: 46CFR176.808(g)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 April 2022
Resolution: Completed drills.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 28 October 2020 Resolved
Vessel operator and crew are currently not enrolled in DAPI program. Vessel's employer needs to establish program for chemical testing.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 June 2021
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 28 October 2020 Resolved
Certificate of Documentation expired June 30, 2020. Vessel must have a valid COD onboard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 June 2021
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 28 October 2020 Resolved
Vessel's floating waterlight is failing to illuminate. Floating waterlight is required to illuminate. 46CFR180.70(d)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 November 2020
Resolution: Master changed out batteries, waterlight is now operable.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 28 October 2020 Resolved
Vessel's reset switch for pre-engineered system is failing to remain activated. Vessel needs a means to reset devices used to shutdown ventilation system and engine. 46CFR181.420(b)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 June 2021
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 28 October 2020 Resolved
Vessel operator did not have FCC Marine Radio Operating Permit present on inspection. Certificates issued by the FCC must be onboard vessel.46CFR176.402(c)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 November 2020
Resolution: Operator presented Marine Radio Operating Permit
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 28 October 2020 Resolved
Bilge high level visual alarm at operating station is not visible. A visual alarm must be provided at operating station.46CFR182.530(a).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 November 2020
Resolution: vessel operator fixed discrepancy, visual alarm is now visible.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 October 2020 Resolved
Vessel was unable to get underway to conduct manoverboard drill and abandonship drill. 46CFR176.808
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 June 2021
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 28 October 2020 Resolved
Vessel was unable to get underway and needs to do so to determine whether the rigging and sails are in satisfactory condition. 46CFR176.404(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 June 2021
Resolved 18 June 2021
04 - Emergency Systems › N/A - No Subsystem › Safe areas
Issued 1 October 2019 Resolved
Current arrangement does not have a ladder for FWD main cabin emergency escape. All passengers must prove ability to egress out of emergency escape until a ladder is installed at next drydock. 46CFR177.15-1
Action required: 705 - Other - as specified
Resolved 15 November 2019
Resolution: Installed ladder for egress to satisfaction of MI.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 1 October 2019 Resolved
All vessels with overnight accomodations shall have a general alarm system. A public address system may be used. No overnight passengers allowed to stay in the forecastle until public address system is repaired 46CFR183.550
Action required: 705 - Other - as specified
Resolved 15 November 2019
Resolution: Vessel installed general alarm, tested and can be heard in both overnight accomodation spaces.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 October 2019 Resolved
Life preservers shall be distributed through the upper deck of the vessel IAW regulation. 46CFR180.25-10
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2019
Resolution: Owner provided photo showing life preserver storage on the upper deck.
04 - Emergency Systems › N/A - No Subsystem › Safe areas
Issued 1 October 2019 Resolved
All emergency exits must be labeled "EMERGENCY EXIT, KEEP CLEAR". Label forward hatch in main cabin and both hatched in forecastle during next drydock. 46CFR185.606
Action required: 705 - Other - as specified
Resolved 15 November 2019
Resolution: All emergency escapes properly labeled to satisfaction of MI.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 October 2018 Resolved
Provide documentation of renewal of expired FCC safety radiotelephone certificate. 47 CFR 80.903.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2018
Resolved 25 February 2019
Resolution: vessel provided updated FCC safety certificate.
Documentation › Certificates/Documents › FCC SSL
Issued 18 October 2017 Resolved
Vessels station license was expired.
Action required: 705 - Other - as specified
Due 18 November 2017
Resolved 15 November 2017
Resolution: New station license recieved effective 03-25-2017.
Documentation › Certificates/Documents › FCC SSL
Issued 18 October 2017 Resolved
Both Masters did not have Marine Radio Operator Permits.
Action required: 705 - Other - as specified
Due 18 November 2017
Resolved 15 November 2017
Resolution: Recieved confirmation for both masters now have valid MROPs.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 2 November 2016 Resolved
Vessel's Certificate of Documentation was expired. Title 46 CFR 67.313 requires the original Certificate of Documentation currently in effect for the vessel on board. You must contact National Vessel Documentation Center and obtain a current copy to be kept on board.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 November 2016
Resolved 2 November 2016
Resolution: Copy of NVDC receipt provided by email same day as inspection. Paperwork filed for expired CoD while MI was on board vessel.
Navigation › Piloting/Steering › Marine Charts
Issued 2 November 2016 Resolved
Vessel did not have current or corrected charts on board. Title 46 CFR 184.420(a) requires vessels to carry adequate and up-to-date charts. You must correct your existing charts or procure new ones to ensure up-to-date versions are available on board.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 December 2016
Resolved 6 March 2017
Resolution: Vessel rep purchased new/updated charts and provided photo of chart to [name withheld] via email.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 2 November 2016 Resolved
Life buoy floating waterlight battery was expired. Title 46 CFR 180.70(d) requires waterlights to be in accordance with their Subchapter Q type approval. You must renew the waterlight battery.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 December 2016
Resolved 12 November 2016
Resolution: Vessel representative replaced battery in ring life buoy floating waterlight. Photo of new battery and its expiration date sent to OCMI via email. Email saved in vessel electronic folder.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 2 November 2016 Resolved
Engine room pre-engineered fixed fire suppression system inspection tag was expired. Title 46 CFR 181.420(a) requires such units to be installed and maintained in accordance with manufacturer's instructions, to include annual inspection. You must perform the required maintenance for the Sea-Fire system and provide a copy of the maintenance report to the OCMI for review upon completion.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 December 2016
Resolved 7 November 2016
Resolution: Vessel representative hire Tarboo Ridge Extinguishers to service engine room Fireboy pre-engineered fixed fire suppression system. Photo of new service tag and expiration date (November 2017) sent to OCMI via email. Email saved in vessel e-folder.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 2 November 2016 Resolved
Sewage system overboard discharge valve was not secured aboard vessel. Title 33 CFR 159.7(b) requires device to be secured using an acceptable, listed method. You must lock or secure the device to the satisfaction of the Marine Inspector.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 2 December 2016
Resolved 22 February 2017
Resolution: Vessel representative removed valve handle from overboard discharge valve and left unit in closed position. Photo of valve and handle sent to OCMI via email. Email saved in vessel electronic folder.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 9 February 2011 Resolved
Organization did not have an employee assistance program meeting the requirements of 46 CFR 16.401
Action required: 705 - Other - as specified
Due 9 March 2011
Resolved 1 March 2011
Resolution: Satisfactory program provided to uscg.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 5 January 2010 Resolved
Make vapor tight bulkhead penetration in forward bulkhead, port side, main engine space.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 February 2010
Resolved 16 February 2010
Stability › Watertight Integrity › General
Issued 5 January 2010 Resolved
Make proper repairs to two aft port side deck railing support stanchions allowing water to slowly leak water into lazarette.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 February 2010
Resolved 16 February 2010
Lifesaving › Lifebuoys › Not on Board
Issued 20 March 2009 Resolved
Master to provide 1 additional approved lifering.
Due 20 March 2009
Resolved 20 March 2009
Resolution: Lifering provided.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 20 March 2009 Resolved
Provide up to date navagation publications.
Condition: Improper/Lack of Maintenance
Due 20 March 2009
Resolved 20 March 2009
Resolution: Up to date publications onboard.
Lifesaving › Lifebuoys › Serviceable
Issued 19 September 2008 Resolved
Service or provide two new lifering buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2008
Resolved 2 October 2008
Resolution: Vsl provided two new lifering buoy properly marked with vsl''s name & with proper retroreflective tape.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 19 September 2008 Resolved
Provide missing toggle switch for the engine start by pass switch.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 October 2008
Resolved 2 October 2008
Resolution: Installed missing toggle switch.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 19 September 2008 Resolved
Prove proper operation of installed fathometer.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 October 2008
Resolved 2 October 2008
Resolution: Resolved problem with vsl''s installed depth sounder. Subsequent operational test with vsl''s lead line sat.
Documentation › Markings/Placards › Official Number (US)
Issued 20 March 2008 Resolved
The name of the vessel was not marked on the exterior part of the port or starboard bow. As per 46CFR67.123(a).
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 April 2008
Resolved 2 October 2008
Resolution: Sighted name of vsl marked iwo port & stbd bow @ 6" in height.
Stability › Watertight Integrity › General
Issued 17 December 2007 Resolved
Renew deck hatches with cracks near their hinges.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 January 2008
Resolved 20 March 2008
Resolution: All deck hatches with cracks were replaced with new hatches. Effective repairs made to the satisfaction of the attending Marine Inspector.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 15 March 2007 Resolved
Properly mount and place waterlight with proper battery on lifefloat.
Condition: Unknown
Due 19 April 2007
Resolved 20 March 2008
Resolution: Waterlight was properly mounted on lifeboat to the satisfaction of the attending Marine Inspector.
Documentation › Certificates/Documents › FCC SSL
Issued 15 March 2007 Resolved
Fax updated safety radiotelephony certificate.
Due 19 April 2007
Resolved 16 January 2008
Electrical › Electric Supply System (service) › Cable
Issued 23 March 2005 Resolved
wiring is being held up in the overhead with plastic tie wraps
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 April 2005
Resolved 12 April 2005
Resolution: plastic tie wraps have been replaced with metal supports.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 23 March 2005 Resolved
Life line was attached to the grab line.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 April 2005
Resolved 12 April 2005
Resolution: life line has been properly attached to the lifebuoy.
Lifesaving › Lifeboat Equipment › Oar
Issued 23 March 2005 Resolved
Paddles were not lashed to life float
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 April 2005
Resolved 12 April 2005
Resolution: Paddles have been properly lashed.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 23 March 2005 Resolved
Emergency escape exit was not labeled to prevent blockage on main deck.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 April 2005
Resolved 12 April 2005
Resolution: escape has been properly labeled.
Lifesaving › Hand Flares
Issued 1 April 2003 Resolved
Vessel did not have required 3 orange day smokes. LEGACY COMPONENT DESC: Quantity
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2003
Communications › Audible Communications
Issued 1 April 2003 Resolved
Vessel did not have a bell as required per the navigation rules. LEGACY COMPONENT DESC: Bell
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2003
Lifesaving › Lifejacket/PFD (General)
Issued 1 April 2003 Resolved
Vessel did not have a lifejacket donning placard posted.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2003
Lifesaving › Rigid Liferafts
Issued 1 April 2003 Resolved
Vessel did not have paddles secured to the lifefloat.
Action required: 705 - Other - as specified
Due 1 May 2003
Resolved 21 April 2003
Lifesaving › Rigid Liferafts
Issued 1 April 2003 Resolved
Cracks on surface of lifefloat need to be repaired. LEGACY COMPONENT DESC: Buoyant Material
Action required: 705 - Other - as specified
Due 1 May 2003
Resolved 25 April 2003
Lifesaving › Lifejacket/PFD (General)
Issued 1 April 2003 Resolved
Storage of lifejackets needs to be properly labled. LEGACY COMPONENT DESC: Storage
Action required: 705 - Other - as specified
Due 1 May 2003
Resolved 21 April 2003
Lifesaving › Lifejacket/PFD (General)
Issued 1 April 2003 Resolved
Childrens lifejackets need to be separated from adults. LEGACY COMPONENT DESC: Storage
Action required: 705 - Other - as specified
Due 1 April 2003
Resolved 21 April 2003
Documentation › Manuals/Policy Documentation
Issued 1 April 2003 Resolved
Vessel needs to provide proof of drug and alcohol program.
Action required: 705 - Other - as specified
Due 1 May 2003
Resolved 2 April 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 15 April 2002 Resolved
Replace all expired first aid kit items. LEGACY COMPONENT DESC: Medicine Chest
Due 23 April 2002
Resolved 16 September 2002
Resolution: Corrected
Fire Fighting › Miscellaneous Items
Issued 15 April 2002 Resolved
Ensure smoke detectors in Forecastle and main cabin operates properly.
Due 23 April 2002
Resolved 16 September 2002
Resolution: Corrected
Lifesaving
Issued 15 April 2002 Resolved
Replace expired EPIRB battery.
Due 23 April 2002
Resolved 16 September 2002
Resolution: Removed EPIRB, it not a required item.
Documentation
Issued 15 April 2002 Resolved
Show proof of current drug and alcohol program enrollment.
Due 23 April 2002
Resolved 7 October 2003
Documentation
Issued 31 May 2000 Resolved
PROVIDE COPY OF APPLICABLE REGULATIONS (46 CFR 166-199).
Condition: Unknown
Due 31 May 2000
Resolved 31 May 2000
Lifesaving
Issued 31 May 2000 Resolved
PROVIDE 2 HAND HELD RED SIGNAL FLARES TO INCREASE TOTAL FLARE COUNT TO 6.
Condition: Unknown
Due 1 June 2000
Resolved 1 June 2000
Lifesaving
Issued 31 May 2000 Resolved
REPAIR LIFEFLOAT TO INCLUDE: NEW RETRO-REFLECTIVE TAPE, RESTENCIL WITH VESSEL NAME AND CAPACITY, AND PROPERLY REPAIR HOLES.
Condition: Unknown
Due 1 June 2000
Resolved 1 June 2000
Lifesaving
Issued 31 May 2000 Resolved
PROVIDE 2 PADDLES, STENCILED WITH VESSEL NAME, ATTACHED TO LIFEFLOAT.
Condition: Unknown
Due 1 June 2000
Resolved 1 June 2000
Lifesaving
Issued 31 May 2000 Resolved
PROVIDE A 100FT LANYARD, WITH FLOAT FREE LINK, FOR LIFEFLOAT.
Condition: Unknown
Due 1 June 2000
Resolved 1 June 2000
Lifesaving
Issued 31 May 2000 Resolved
PROVIDE WORKING WATERLIGHT FOR RING BUOY AND LIFE FLOAT.
Condition: Unknown
Due 1 June 2000
Resolved 1 June 2000
Construction/Loadline
Issued 31 May 2000 Resolved
INSTALL BILGE ALARM SYSTEM IAW 46 CFR 182.530(A) TO MONITOR EACH SPACE AND INDICATE WITH AUDIO AND VISUAL ALARM SEPERATELY AT THE OPERATING STATION.
Condition: Unknown
Due 31 May 2000
Resolved 31 May 2000
Documentation
Issued 31 May 2000 Resolved
POST COI UNDER GLASS IAW 46 CFR 176.302.
Condition: Unknown
Due 1 June 2000
Resolved 1 June 2000
Documentation
Issued 10 March 1998 Resolved
PROVIDE UPDATED STABILITY LETTER REFLECTING THE RELOCATION AND ADDITION OF WATER TANKS TO THE VESSEL. NO PASSENGERS ARE PERMITTED TO BE CARRIED ONBOARD UNTIL AN UPDATED STABILITY LETTER IS PROVIDED.
Condition: Unknown
Due 10 March 1998
Resolved 10 March 1998

Casualty record · 4

19 September 2008Routine · role: Involved in a Marine Casualty · activity 3328512
2 July 2009Routine · role: Involved in a Marine Casualty · activity 3526202
22 March 2011Routine · role: Involved in a Marine Casualty · activity 3969792
27 May 2013Routine · role: Involved in a Marine Casualty · activity 4604531
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.