KATARA is a 1996 passenger vessel (inspected). The Coast Guard has recorded 45 inspections since 1996, most recently in April 2026, along with 70 deficiencies.

Records from 1996 to 2026. Most recent: inspection, 23 April 2026.

Built
1996
Last inspected
23 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDM5690
441231
Flag
UNITED STATES
367742720, 368218270
Maury page id
psix-441231

Inspections, by type

…with no type recorded2
Years with a record 29 calendar years (1996–2026)
The 45 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)31.3 ft × 11.2 ft × 5.3 ft
Registered tonnagegross 12 / net 9
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEACOAST BOATBUILDERS INC · MILTON, NH, UNITED STATES · built 1996
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portBOCA GRANDE, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 25 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it12 - Simplified, Gross Ton
9 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDM5690MMSI 368218270 · active · compulsorily equipped · granted 9 September 2021, expires 9 September 2031
WDK4349MMSI 367742720 · active · compulsorily equipped · granted 11 August 2018, expires 11 August 2028
WDI8845MMSI 367742720 · cancelled · voluntarily equipped · granted 23 June 2016, cancelled 12 June 2017
WCW7871MMSI 367112540 · expired · compulsorily equipped · granted 9 May 2006, cancelled 8 October 2016
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 45

23 April 2026 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8354533
16 July 2025 Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8186262
13 August 2024 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7975453
29 May 2024 Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7921679
7 August 2023 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7758539
13 October 2022 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7576961
8 June 2022 Deficiency Check · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7467407
1 June 2022 Internal Structural Exam · Deficiency Check · Drydock Exam · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7464448
7 September 2021 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7305995
9 September 2020 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7054124
10 June 2020 Deficiency Check · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6971157
10 September 2019 Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6804849
30 August 2018 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6526081
31 May 2018 Internal Structural Exam · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6429876
15 May 2017 Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6146614
25 August 2016 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5974989
12 May 2016 Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5857632
26 August 2015 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5214534
20 June 2014 Construction Oversight
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4894241
8 May 2014 Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4846400
19 June 2012 Administrative Inspection · COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4347893
10 May 2012 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4301548
9 September 2011 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4140243
1 September 2010 Deficiency Check · DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3832395
14 July 2008 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3267375
15 May 2008 Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3205438
9 July 2007 Administrative Inspection · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2982970
12 July 2006 Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2704438
9 June 2006 Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2674625
25 August 2005 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2473990
19 May 2005 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2362441
23 September 2004 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2202742
22 June 2004 Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2106144
25 June 2003 Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1826267
11 July 2002 COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1643848
17 June 2002 Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1632678
25 June 2001 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1391637
19 June 2000 Hull Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1455904
15 July 1999 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1438892
16 June 1998 Hull Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1129234
24 July 1997 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1402551
18 November 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1459357
31 July 1996 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1270409
22 July 1996 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1088522
18 July 1996 Initial Certification · Hull Examination · MARPOL Annex V Examination · Inclining Experiment · Plan Review "T" Boat
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1086362

Deficiency record · 70

01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 13 August 2024 Resolved
Each ship transporting more than six passengers for hire equipped with a radiotelephone station in accordance with Part III of Title III of the Communications Act must carry a radio operator who meets the following requirements: the radio operator must hold a marine radio operator permit or higher class license. Vessel does not have a radio operator. Provide evidence of Marine Radio Operator Permit to the USCG. 47CFR80.159(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 October 2024
Resolution: Vessel now has a radio operator. Provided evidence of Marine Radio Operator Permit to the USCG.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 13 August 2024 Resolved
A certification that the ship has passed an inspection must be entered into the ship's log by the inspecting technician. The technician conducting the inspection and providing the certification must not be the vessel's owner, operator, master, or employee or their affiliates. Additionally, the vessel owner, operator, or ship's master must certify in the station log that the inspection was satisfactory. Vessel's FCC Radiotelephony Inspection Certificate is expired. Provide valid certificate to the USCG. 47CFR80.59(a)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 August 2024
Resolution: Vessel's FCC Radiotelephony Inspection Certificate now valid. Vessel completed FCC Radiotelephony Safety Inspection on 19AUG2024, new certificate expires on 19AUG2029.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 August 2024 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces:(1) A space with a through-hull fitting below the deepest load waterline, such as a lazarette;(2) A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space; and(3) A space with a non-watertight closure, such as a space with a non-watertight hatch on the main deck. A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Bilge 1: High water level visual and audible alarm is non-functional. Does not have a visual indicator provided at the operating station to indicate when automatic bilge pump is operating. Bilge 2: Does not have a visual indicator provided at the operating station to indicate when automatic bilge pump is operating. Make permanent repairs to the satisfaction of the attending CG Marine Inspector. 46CFR182.530
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 August 2024
Resolution: Bilge 1: High water level visual and audible alarm are now functional and now has a visual indicator provided at the operating station to indicate when automatic bilge pump is operating. Bilge 2: Now has a visual indicator provided at the operating stati
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 29 May 2024 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Identified improperly secured swim platform attached to the exterior stern of the vessel. Properly secure swim platform. 46CFR176.830(a)
Action required: 705 - Other - as specified
Due 29 May 2024
Resolved 6 June 2024
Resolution: Properly secured swim platform.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 May 2024 Resolved
A suitable metal marine type strainer, meeting the requirements of the engine manufacturer, must be fitted in the fuel supply line in the engine compartment. Strainers must be leak free. Strainers must be the type of opening on top for cleaning screens. A drip pan fitted with flame screen must be installed under gasoline strainers. Fuel filter and strainer bowls must be highly resistant to shattering due to mechanical impact and resistant to failure due to thermal shock. Fuel filters fitted with bowls of other than steel construction must be approved by the Commandant and be protected from mechanical damage. Approval of bowls of other than steel construction will specify if a flame shield is required. Identified fuel system marine type strainer is not properly installed IAW MFR specifications. Install the fuel system marine type strainer assembly heat shield component to MFR requirements to meet ASTM F1201 specifications. 46CFR182.455(b)(6)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 June 2024
Resolution: Installed the fuel system marine type strainer assembly heat shield component to MFR requirements to meet ASTM F1201 specifications.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 8 June 2022 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in a machinery space. Vessel has 2 bilge pumps, neither one has a working audible or visual alarm at the operating station. Operator shall provide plan for alternative means of checking bilge water levels. 46 CFR 182.530(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2022
Resolved 19 June 2022
Resolution: Received video of bilge pump working with audible and visual alarm.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 1 June 2022 Resolved
The water inlet valve for the toilet is frozen in the open position and the valve handle is missing. Temporarily fixed by blocking the inlet pipe at valve assembly. Make permanent repairs prior to using toilet.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2022
Resolved 2 June 2022
Resolution: Received pictures of new valve in both the open and closed position.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 September 2021 Resolved
Could not test engine shutdown of Fireboy system. Prove proper operation to the satisfaction of a Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2021
Resolved 14 September 2021
Resolution: Received video showing satisfactory test of engine shutdown. Also received fire extinguisher service report.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 September 2021 Resolved
Port and starboard navigation lights do not display 112.5 arc of visibility.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2021
Resolved 14 September 2021
Resolution: Navigation lights put in proper orientation.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Medical Equipment, medical chest, medical guide
Issued 7 September 2021 Resolved
Provide first aid kit that meets 46CFR160.041
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2021
Resolved 14 September 2021
Resolution: Proper first aid kit onboard.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 7 September 2021 Resolved
Provide emergency broadcast placard for VHF radio.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2021
Resolved 14 September 2021
Resolution: Emergency broadcast placard placed IWO VHF radio.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 7 September 2021 Resolved
Provide radio operator permits for masters.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2021
Resolved 10 September 2021
Resolution: Received copy of certificates.
01 - Certificates & Documentation › 013 - Documents › Certificate or documentary evidence of financial security relating to shipowners liability
Issued 7 September 2021 Resolved
Provide updated DAPI consortium for calendar year.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2021
Resolved 10 September 2021
Resolution: Received updated MIS submission for 2021.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 7 September 2021 Resolved
Provide current Coast Pilot [name withheld] and Tide Tables for navigation area.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2021
Resolved 10 September 2021
Resolution: Received picture of updated publications.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 September 2020 Resolved
Fireboy for engine compartment discharged during inspection. Provide proof of fully operational fire fighting system.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2020
Resolved 23 September 2020
Resolution: Received report via e-mail and photos of newly installed Fireboy.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 10 June 2020 Resolved
Both watertight hatches do not close. Prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 25 June 2020
Resolution: Received pictures and written statement via e-mail that hatches are working properly.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 10 June 2020 Resolved
Overboard valve for the Marine Sanitation Device is inoperable. Prover proper operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 25 June 2020
Resolution: Received pictures and affirmation via e-mail of properly working through hull fitting.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 June 2020 Resolved
Support bracket IWO battery installation for grounding connections is wasted. Replace with new support.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 25 June 2020
Resolution: Received photos via e-mail of new support for electrical connections.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 10 September 2019 Resolved
Provide updated charts
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2019
Resolved 13 September 2019
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 10 September 2019 Resolved
Post emergency instructions
Action required: 10 - Deficiency Rectified
Due 24 September 2019
Resolved 10 September 2019
Resolution: Emergency instructions found and posted.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 10 September 2019 Resolved
Connect highwater audible/visual alarms to alarm panel
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 September 2019
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 10 September 2019 Resolved
Provide evidence Master has FCC marine operator's permit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2019
Resolved 13 September 2019
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 30 August 2018 Resolved
FCC safety certificate is expired. Do not go more than 1000' from shore until new certificate is provided. (47CFR155.303)
Action required: 705 - Other - as specified
Resolved 31 August 2018
Resolution: New inspection completed.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 15 May 2017 Resolved
Replace retro-reflective tape on lifejackets and life ring. (46CFR185.604)
Action required: 705 - Other - as specified
Due 29 June 2017
Resolved 22 June 2017
Resolution: Replaced retro on lifejackets and life ring.
Lifesaving › Hand Flares › Expired
Issued 25 August 2016 Resolved
Provide on board a total of six flares IAW 46 CFR 180.64.
Action required: 705 - Other - as specified
Due 26 August 2016
Resolved 25 August 2016
Resolution: Vessel operator provided six total flares on board vessel IAW 46 CFR 180.64.
Navigation › Piloting/Steering › Marine Charts
Issued 25 August 2016 Resolved
Provide on board current chart(s) and tide tables for area transited. 46 CFR 184.420
Action required: 705 - Other - as specified
Due 1 September 2016
Resolved 25 August 2016
Resolution: Operator provided proof of purchase of current NOAA charts and current tide tables.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 25 August 2016 Resolved
Provide current log of man overboard / fire / abandon ship drills. 46 CFR 185.520/524
Action required: 705 - Other - as specified
Due 1 September 2016
Resolved 25 August 2016
Resolution: Operator provided log entries for recent drills.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 25 August 2016 Resolved
Provide current MIS report and list of compliant employees from the consortium. 46 CFR 16.260
Action required: 705 - Other - as specified
Due 1 September 2016
Resolved 25 August 2016
Resolution: Operator provided latest MIS report and list of employees from consortium.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 26 August 2015 Resolved
Provide proof of 2014 MIS Submission Form, IAW 46 CFR 16.260.
Action required: 705 - Other - as specified
Due 4 September 2015
Resolved 26 August 2015
Resolution: Rcvd copy of 2014 MIS Form.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 26 August 2015 Resolved
Provide onboard one BI fire extinguisher at the helm station, IAW 46 CFR 181.500.
Action required: 705 - Other - as specified
Due 28 August 2015
Resolved 27 August 2015
Resolution: Owner installed BI at operating station.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 26 August 2015 Resolved
Provide copy of Valid Certificate of Documentation, IAW 46 CFR 67.7.
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 September 2015
Resolved 27 September 2015
Resolution: Owner rcvd new Valid COD.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 26 August 2015 Resolved
Provide a way to receive/provide passenger count to the Coast Guard, IAW 46 CFR 185.504
Action required: 705 - Other - as specified
Due 4 September 2015
Resolved 27 August 2015
Resolution: Owner installed PVC tube at home dock for daily run and passenger counts.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 19 June 2012 Resolved
Provide EAP supervisor training IAW 46 CFR 16.
Due 26 June 2012
Resolved 26 June 2012
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 June 2012 Resolved
Provide on board aspirin and burn gel that is not expired and IAW 46 CFR 184.710.
Action required: 705 - Other - as specified
Due 26 June 2012
Resolved 20 June 2012
Communications › Alarms/Indicators › Bilge Alarm
Issued 1 September 2010 Resolved
Repair/Replace bilge high level alarm in the fwd compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 September 2010
Fire Fighting › Ventilation Systems › Ducts
Issued 1 September 2010 Resolved
Repair.Replace closure device for the engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 September 2010
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 1 September 2010 Resolved
Provide proof of active EAP.
Due 7 September 2010
Resolved 18 September 2010
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 1 September 2010 Resolved
Provide new alcohol test kits onboard.
Due 14 September 2010
Resolved 18 September 2010
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 9 July 2007 Resolved
Provide service report for one fire extinguisher.
Due 16 July 2007
Resolved 13 July 2007
Lifesaving › Hand Flares › Quantity
Issued 9 July 2007 Resolved
Provide one orange flare.
Due 16 July 2007
Resolved 13 July 2007
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 9 July 2007 Resolved
Mark one lifejacket with vessel name and install retro reflective tape on (7) adult and (2) child lifejackets.
Due 16 July 2007
Resolved 13 July 2007
Documentation › Markings/Placards › Lifejacket Placard
Issued 12 July 2006 Resolved
Post lifejacket donning placard.
Due 19 July 2006
Resolved 14 July 2006
Resolution: O/O call and stated placard posted
Lifesaving › Lifebuoys › Serviceable
Issued 25 August 2005 Resolved
Make permanent repairs to cracks begging to form on Life buoy.
Due 15 September 2005
Resolved 2 September 2005
Documentation › Logs/Records › Drug Test Records
Issued 25 August 2005 Resolved
Provide MIS report for 2004 (DAPI).
Due 15 September 2005
Resolved 2 September 2005
Documentation › Logs/Records › Drug Test Records
Issued 25 August 2005 Resolved
Provide procedures for chemical testing Post Serious Marine Incident
Due 15 September 2005
Resolved 2 September 2005
Lifesaving › Buoyant Apparatus › Marking
Issued 23 September 2004 Resolved
REPAINT BOUYANT APPARATUS ORANGE AS ORIGINAL.
Condition: Unknown
Due 3 October 2004
Resolved 20 October 2004
Navigation › Piloting/Steering › Coast Guard Light List
Issued 25 June 2003 Resolved
Provide Coast Pilot [name withheld] for area of operation or provide Reeds.
Action required: 705 - Other - as specified
Due 14 July 2003
Resolved 15 July 2003
Communications › Alarms/Indicators › Bilge Alarm
Issued 25 June 2003 Resolved
Provide audible hight water bilge alarm in engine room.
Action required: 705 - Other - as specified
Due 14 July 2003
Resolved 15 July 2003
Stability › Watertight Integrity
Issued 25 June 2003 Resolved
Provide Captive chains on all hatches.
Action required: 705 - Other - as specified
Due 14 July 2003
Resolved 16 July 2003
Stability › Watertight Integrity
Issued 25 June 2003 Resolved
Repair hatch in well deck.
Action required: 705 - Other - as specified
Due 14 July 2003
Resolved 15 July 2003
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 June 2003 Resolved
Provide content list for first aid kit and replace expired items in kit.
Action required: 705 - Other - as specified
Due 14 July 2003
Resolved 16 July 2003
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 25 June 2003 Resolved
Provide new manual cable for fixed systen activation. Cable sheathing has been removed in a small section.
Action required: 705 - Other - as specified
Due 14 July 2003
Resolved 15 July 2003
Resolution: Fire system service rep. stated on letter that cable is fully functional. New cable on order and will be installed at a later date.
Stability › Freeing Ports
Issued 25 June 2003 Resolved
Remove flappers from freeing ports.
Action required: 705 - Other - as specified
Due 14 July 2003
Resolved 15 July 2003
Lifesaving › Lifebuoys
Issued 11 July 2002 Resolved
Apply retro-reflective tape to ring bouy. LEGACY COMPONENT DESC: Markings (ship name/port)
Action required: 705 - Other - as specified
Due 11 August 2002
Resolved 15 August 2002
Resolution: VISITED VESSEL, EXAMINED ITEMS, CLEARED.
Lifesaving › Buoyant Apparatus
Issued 11 July 2002 Resolved
Repair bouyant appartus with manufacturer's repair sealant.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 August 2002
Resolved 15 August 2002
Resolution: VISITED VESSEL, EXAMINED ITEMS, CLEARED.
Lifesaving › Buoyant Apparatus
Issued 11 July 2002 Resolved
Apply new retro-reflective tape to bouyant apparatus.
Action required: 705 - Other - as specified
Due 11 August 2002
Resolved 15 August 2002
Resolution: VISITED VESSEL, EXAMINED ITEMS, CLEARED.
Lifesaving
Issued 19 June 2000 Resolved
PROVIDE AN APPROVED FIRST AID KIT, IAW 46CFR160.041.
Condition: Unknown
Due 19 June 2000
Resolved 19 June 2000
Documentation
Issued 18 July 1996 Resolved
PROVIDE WASTE MANAGEMENT PLAN
Condition: Unknown
Due 18 July 1996
Resolved 18 July 1996
Navigation
Issued 18 July 1996 Resolved
RAISE ALL AROUND WHITE LIGHT TO ALLOW FOR FORWARD VISIBILITY_x001C_ _x001C_ TO BE CORRECTED PRIOR TO OPERATING AFTER SUNSET OR DURING PERIODS OF REDUCED VISIBILITY.
Condition: Unknown
Due 18 July 1996
Resolved 18 July 1996
Accommodation/Occupational Safety
Issued 18 July 1996 Resolved
PROVIDE EMERGENCY LIGHTING IN ACCORDANCE WITH 46 CFR 183.432 FOR LOWER CABIN_x001C_ _x001C_ TO BE CORRECTED PRIOR TO OPERATING AT NIGHT
Condition: Unknown
Due 18 July 1996
Resolved 18 July 1996
Lifesaving
Issued 18 July 1996 Resolved
POST EMERGENCY CHECKOFF LIST AND PFD DONNING PLACARDS_x001C_ _x001C_ TO BE CORRECTED PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 18 July 1996
Resolved 18 July 1996
Documentation
Issued 18 July 1996 Resolved
PROVIDE FCC SAFETY EQUIPMENT CERTIFICATE_x001C_ _x001C_ VESSEL RESTRICTED TO NOT MORE THAN 1000 FEET FROM SHORE UNTIL CORRECTED
Condition: Unknown
Due 18 July 1996
Resolved 18 July 1996
Lifesaving
Issued 18 July 1996 Resolved
PROVIDE PFD STOWAGE IN ACCORDANCE WITH 46 CFR 180.78_x001C_ _x001C_ TO BE CORRECTED PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 18 July 1996
Resolved 18 July 1996
Engineering
Issued 18 July 1996 Resolved
REPAIR ENGINE LUBE OIL PRESSURE GAGE
Condition: Unknown
Due 18 July 1996
Resolved 18 July 1996
Engineering
Issued 18 July 1996 Resolved
PROVIDE TOOL TO OPEN FUEL OIL EMERGENCY SHUTOFF VALVE ACCESS COVERS._x001C_ _x001C_ TO BE CORRECTED PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 18 July 1996
Resolved 18 July 1996
Lifesaving
Issued 18 July 1996 Resolved
PROVIDE DISTRESS FLARES IN ACCORDANCE WITH 46 CFR 180.68_x001C_ _x001C_ TO BE CORRECTED PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 18 July 1996
Resolved 18 July 1996
Lifesaving
Issued 18 July 1996 Resolved
PROVIDE LIFEFLOAT FOR 50% OF PERSONS ALLOWED IN ACCORDANCE WITH 46 CFR 180.205_x001C_ _x001C_ VESSEL RESTRICTED TO NOT MORE THAN 01 MILE FROM LAND UNTIL CORRECTED
Condition: Unknown
Due 18 July 1996
Resolved 18 July 1996
Documentation
Issued 18 July 1996 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 18 July 1996
Resolved 18 July 1996
Navigation
Issued 18 July 1996 Resolved
PROVIDE COMPASS DEVIATION CARD
Condition: Unknown
Due 18 July 1996
Resolved 18 July 1996
Engineering
Issued 18 July 1996 Resolved
REPAIR ENGINE WATER TEMPERTURE GAGE
Condition: Unknown
Due 18 July 1996
Resolved 18 July 1996

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.