MAURY USCG vessel records Sign in
← All vessels

FREEDOM

FREEDOM is a 1961 passenger vessel (inspected). The Coast Guard has recorded 114 inspections since 1985, most recently in June 2025, along with 161 deficiencies, 6 operational controls and 5 casualty investigations between 2005 and 2022.

Records from 1985 to 2025. Most recent: inspection, 10 June 2025.

Built
1961
Last inspected
10 June 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDQ3286
Flag
UNITED STATES
367621160
Maury page id
psix-44124

Inspections, by type

…with no type recorded21
Years with a record 38 calendar years (1985–2025)
The 114 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)79.0 ft × 23.2 ft × 5.8 ft
Registered tonnagegross 92 / net 62
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDITTMAR & DONALDSON DBA · COSTA MESA, CA, UNITED STATES · built 1961
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portLOS ANGELES, CA
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 30 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it92 - Regulatory (Subpart C or D), Gross Ton
62 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ3286MMSI 367621160 · active · compulsorily equipped · granted 23 April 2025, expires 23 April 2035
WDH4766MMSI 367621160 · expired · compulsorily equipped · granted 14 May 2014, cancelled 20 July 2024
WDC2225MMSI 366989750 · expired · compulsorily equipped · granted 10 November 2004, cancelled 10 January 2015
WCN9253MMSI 366685640 · expired · compulsorily equipped · granted 28 June 1995, cancelled 25 December 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 114

10 June 2025 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8116392
27 July 2024 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7959128
12 March 2024 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7816685
1 March 2024 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7872540
29 January 2024 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7816681
12 October 2023 Administrative Inspection · Deficiency Check · Appeal
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7826944
19 July 2023 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7744924
31 May 2023 Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7702120
31 March 2023 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7655815
3 February 2023 Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7631541
26 January 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7577664
21 October 2022 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7576923
20 August 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7538661
20 August 2022 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7542991
15 June 2022 In-Service Inspection · Administrative Inspection · Plan Review "T" Boat
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7485393
19 April 2022 DAPI Audit · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7401478
13 January 2022 Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7379242
5 December 2021 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7362818
18 May 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7200141
23 July 2020 Annual Inspection · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7013972
17 January 2020 Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6891193
1 October 2019 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6816947
20 August 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6789912
18 August 2019 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6790879
4 June 2019 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6649492
26 April 2019 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6670940
26 November 2018 Plan Review "T" Boat · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6597277
20 August 2018 Examination of Repairs · Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6520195
23 April 2018 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6380443
21 March 2018 Hull Examination · Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6373335
20 February 2018 Drydock Extension
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6358688
1 December 2017 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6316626
1 December 2017 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6318045
28 November 2017 Administrative Inspection
Administrative · Navigation Center · Activity 6313803
24 February 2017 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6131638
7 March 2016 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5818400
27 January 2016 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5800228
23 May 2014 Annual Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4846834
23 February 2012 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4239926
26 January 2012 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4218257
30 December 2010 Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3930155
2 March 2010 Annual Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3684643
10 February 2010 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3715081
30 March 2009 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3443213
2 March 2009 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3402673
7 March 2008 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3158899
28 February 2008 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3146309
28 November 2007 Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3092021
7 March 2007 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2871427
6 April 2006 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2618667
6 March 2006 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2593918
4 December 2005 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2545594
1 July 2005 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2424345
10 March 2005 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2302813
13 January 2005 Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2274349
3 March 2004 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2017150
5 February 2004 Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2001377
17 December 2003 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1965252
18 March 2003 Deficiency Check · Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1756875
1 March 2002 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1490482
1 March 2002 Plan Review "T" Boat · Construction Oversight
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1495771
13 December 2001 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1600114
11 April 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 33069
6 March 2001 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1382442
25 October 2000 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 78813
4 August 2000 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1366674
3 August 2000 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 135823
3 August 2000 Damage Survey
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1421907
18 February 2000 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1408464
8 September 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 138445
9 June 1999 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 807672
24 March 1999 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1365132
25 January 1999 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1386409
6 September 1998 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 113254
18 March 1998 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1364639
29 October 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1375171
20 September 1997 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 72253
6 March 1997 Hull Examination · Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1437219
28 March 1996 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1400326
7 March 1996 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 885380
15 February 1996 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1452101
11 January 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1192837
30 August 1995 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1367501
15 March 1995 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1134791
4 October 1994 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 871076
31 August 1994 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1462403
8 November 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 846926
15 October 1993 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 833570
3 September 1993 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 841119
30 August 1993 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 825775
21 April 1993 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 841434
5 February 1993 Damage Survey
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1138310
18 November 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 664110
15 October 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1270127
17 September 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1263838
2 September 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 960058
21 April 1992 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1261214
11 December 1991 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 945326
10 September 1991 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1253609
31 May 1991 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1220950
23 April 1991 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1241086
26 June 1990 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1213830
4 May 1990 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1244726
7 December 1989 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1241470
9 May 1989 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1196912
26 May 1988 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1195549
12 May 1988 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1351185
17 November 1987 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1332001
13 May 1987 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1024370
6 June 1986 Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 995595
15 May 1986 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 988163
12 June 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1288423
17 May 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1287367
30 January 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 982427

Deficiency record · 161

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 July 2024 Resolved
Each distribution panel and switchboard must be in as dry a location as practicable, adequately ventilated, and protected from falling debris and dripping or splashing water. Door on distribution panel in engine room swung open freely. Install method for door to remain closed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 August 2024
Resolved 23 September 2024
Resolution: Pictures provided showing magnetic closure to keep door from swining.
09 - Working and Living Conditions › 091 - Living Conditions › Berth dimensions, etc.
Issued 29 May 2024 Resolved
Bunks, where installed, arrangement shall be not more than three high, with a minimum distance of 24 inches vertically between bunks; ladders or steps shall be provided for each top bunk. Construction and arrangement shall allow free and unobstructed access to the bunks. Vessels current arrangement is four high bunks in both port and starboard overnight accommodation spaces with the top racks measuring 79-inches from the deck to bottom of rack. This arrangement is considered a safety hazard due to the height of the bunks and the lack of adequate ladders or means of disembarking without the use of bunks below. Passenger use/occupancy of the uppermost bunks (4th tier) shall be discontinued. OLD T: 46 CFR 177.30-7(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 July 2024
Resolution: Verified top (4th) bunks had mattresses removed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 March 2024 Resolved
Clean & treat identified areas in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 March 2024
Resolution: Vsl rectified deficiency.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 March 2024 Resolved
The owner or managing operator shall make a vessel available for drydock examinations. A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel is overdue for required drydock inspection. Vessel must complete credit drydock inspection prior to the carriage of passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 March 2024
Resolution: Vessel successfully rectified open deficiencies and completed sea trial, dry credit given this day.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 29 January 2024 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. EPIRB onboard was not serviceable. Vessel Route restricted to operating only within 3NM from nearest point of land.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 7 February 2024
Resolution: EPIRB Replaced
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 January 2024 Resolved
A vessel must carry one floating waterlight. Each floating waterlight installed after March 11, 1997, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion-resistant clip. Light not serviceable due to water intrusion into lens; clip is seized in open position.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2024
Resolved 14 March 2024
Resolution: Replaced light and clip.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 January 2024 Resolved
Each ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Life buoy missing 2 letters.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2024
Resolved 14 March 2024
Resolution: Name on vessel is properly marked.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 January 2024 Resolved
Each lifejacket must have a whistle of the ball type or multi-tone type and of corrosion-resistant construction. 01 lifejacket missing whistle.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2024
Resolved 14 March 2024
Resolution: Whistle has been replaced.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 29 January 2024 Resolved
Alcohol-testing devices must be used according to the procedures specified by the manufacturer of the testing device and by this part. Test strips expired. 46 CFR 4.06-3(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2024
Resolved 14 March 2024
Resolution: New alcohol test strips were obtained.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 29 January 2024 Resolved
A vessel must carry a first-aid kit. Aspirin expired. 46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2024
Resolved 14 March 2024
Resolution: Updated aspirin has been obtained.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 29 January 2024 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date. Publications out of date (tide tables, coast pilot and light list). 46 CFR 184.420 (a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2024
Resolved 7 February 2024
Resolution: Obtained new pubs
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 29 January 2024 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions. No emergency instructions onboard. 46 CFR 185.510
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2024
Resolved 7 February 2024
Resolution: Emergency instructions posted
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 29 January 2024 Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. 01 penetration in watertight bulkhead in crew berthing bilge space was not sealed. 46 CFR 179.320(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2024
Resolved 7 February 2024
Resolution: Penetration sealed
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 29 January 2024 Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew accommodation spaces located below the main deck. 02 Emergency lighting in passenger accommodation space flickers constantly. 46 CFR 183.432 (a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2024
Resolved 7 February 2024
Resolution: Lighting fixed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 January 2024 Resolved
When the flexible section is a nonconductor of electricity, the metallic sections of the fill pipe separated thereby must be joined by a conductor for protection against generation of a static charge when filling with fuel. 04 fuel tank fill stations missing ground wire, repair at next dry dock to the satisfaction of an attending USCG Marine Inspector. 46 CFR 182.445 (g)
Action required: 705 - Other - as specified
Due 1 March 2024
Resolved 26 March 2024
Resolution: 04 fuel tank fill stations ground wires have been attached
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 31 May 2023 Resolved
Fire and smoke detection interconnected. During fixed interconnected fire detection installation verification, noted upper port and stbd modular detectors in head not installed. Attending inspector made slight modification to approved plan, and one modular detector in upper galley near P/S head is adequate (but not presently installed, all other fixed detection upgrades were satisfactory per installation plan).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 June 2023
Resolution: Operator provided photo and attestation to operability of additional smoke detector installed and networked into system to attain ideal coverage of vessel.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 3 February 2023 Resolved
Vessels described by 46 CFR 175.110(d) must submit plans to the cognizant OCMI, in accordance with 46 CFR 176.700, for the installation and use of monitoring device to ensure the wakefulness of the watchmen required in paragraph (a) of this section. Vessel is restricted from the carriage of overnight passengers until manufacturer plans for the monitoring device described above have been submitted.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 February 2023
Resolved 16 February 2023
Resolution: Plans Submitted. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 January 2023 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel experienced STBD MDE raw water pump was casualty during inspection. 46 CFR 182.200 (a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 March 2023
Resolution: Raw water pump on port and stbd main engines was replaced. Propulsion was tested, all appears to be sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 August 2022 Resolved
The following spaces must be equipped with a fixed gas fire extinguishing system, in compliance with § 181.410, or other fixed fire extinguishing system specifically approved by the Commandant, except as otherwise allowed by paragraph (b) of this section:(1) A space containing propulsion machinery. Vessel's fixed fire-fighting system was accidentally discharged leaving no means of combating a fire in the engine room with a fixed system.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 September 2022
Resolved 22 August 2022
Resolution: Vessel Conducted Fixed fire servicing via marine fire protection. Verified proper installation and servicing of the CO2 system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 August 2022 Resolved
Each vessel that relies on electricity to power the following loads must be arranged so that the loads can be energized from two sources of electricity...Master is unable to start the generator and provide ships service power after an accidental discharge of the machinery space fixed fire-fighting system.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 September 2022
Resolved 22 August 2022
Resolution: Verified that the vessels generator properly runs under load and that the crew is familiar with CO2 discharge procedures and how to restart machinery after CO2 discharge.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 19 April 2022 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date navigation charts. Inspector found that the vessel did not have updated navigational charts.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2022
Resolved 22 August 2022
Resolution: Verified that the vessel has updated charts within the last year and is familiar with procedures for updating charts and navigation hazards.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 19 April 2022 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1 inch high indicating purpose of the valve and direction of operation. Inspector found that the fuel shutoff valves were not marked.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2022
Resolved 22 August 2022
Resolution: Verified proper labeling of the fuel shutoff stations. Fuel shutoffs are labeled in red 1 inch block lettering
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 May 2021 Resolved
Individual power bilge pumps must have a light at operator station, indicationg operation. All 4 submersible bilge pump indicators not operational.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2021
Resolved 16 June 2021
Resolution: Verified proper operation of bilge pump indicators. All SAT.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 18 May 2021 Resolved
Emergency lighting must be provided along the line of escape to the main deck from all passenger & crew accomodations below deck. FWD egress lighting extinguished in passenger accom space.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2021
Resolved 16 June 2021
Resolution: Verified proper operation of emergency lighting in accommodation space.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 January 2020 Resolved
All griddles, broilers, and deep fat fryers must be fitted with a grease extraction hood in compliance with 46CFR181.425 Vessel's installed hood does not meet UL 710 Standard and is not equipped with a dry or wet chemical fire extinguisher system meeting NFPA 17 or NFPA 17A. Vessel is restricted from using griddle until proper installation of hood and extinguisher system is verified by the attending Marine Inspector.
Action required: 705 - Other - as specified
Due 29 January 2020
Resolved 16 June 2021
Resolution: Verified installation and servicing report for the new installation of galley hood fire suppression system.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 17 January 2020 Resolved
Vertical or horizontal surfaces within 3 feet of cooking appliances must have an ASTM E-84 flame spread rating of not more than 75. Vessel's installed griddle is within 3 feet of surfaces that do not meet required flame spread rating.
Action required: 705 - Other - as specified
Due 29 January 2020
Resolved 19 October 2020
Resolution: Stainless steel flashing was applied to surface areas within 3ft of the installed griddle.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 August 2019 Resolved
Propulsion machinery must be suitable in type and design for the propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its design requirements. Vessel lost propulsion. Prove proper operation of the propulsion machinery prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 August 2019
Resolved 20 August 2019
Resolution: Proved proper operation of propulsion and generator machinery. At sea trail, all sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 4 June 2019 Resolved
Provide current FCC Safety certificate; cert is expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2019
Resolved 25 June 2019
Resolution: Vessel provided renewed FCC safety cert.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 4 June 2019 Resolved
Vessel shall have name and hailing port along transom of vessel. Provide hailing port on transom.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2019
Resolved 17 June 2019
Resolution: Provided hailing port onto transom.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 4 June 2019 Resolved
Repair holes in aft engine room bulkhead.
Action required: 10 - Deficiency Rectified
Due 18 June 2019
Resolved 4 June 2019
Resolution: Corrected during inspection.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 5 May 2017 Resolved
Make thru-bkhd penetrations in crew bunk space watertight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 June 2017
Resolved 11 May 2017
Resolution: covered gap with wood and filled addition thru holes with foam to maintain water tight integrity
Fire Fighting › Remote Fuel Shutoff › General
Issued 5 May 2017 Resolved
Install shutoff valves on 500-gallon fuel tanks for fuel transfer lines.
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 11 May 2017
Resolution: replaced piping from the fuel tanks, relocating the fuel shut offs to the base of both the port and starboard 500 gal tanks. Found system to be functional and effective.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 5 May 2017 Resolved
Install 30x30 corrosion resistant wire mesh on 03 fuel tank vents.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 June 2017
Resolved 11 May 2017
Resolution: covered vent pipes with 30x30 meshing
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 5 May 2017 Resolved
Pay balance owed for overdue user fee.
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 5 May 2017
Resolution: Outstanding balance paid.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 5 May 2017 Resolved
Post COI so all pages are visible.
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 5 May 2017
Resolution: COI posted properly.
Documentation › Certificates/Documents › FCC SSL
Issued 5 May 2017 Resolved
Provide FCC Marine Radio Operato's Permit for inspection.
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 5 May 2017
Resolution: Permit produced prior to inspection completion.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 5 May 2017 Resolved
Provide master's license.
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 5 May 2017
Resolution: Master's license provided prior to inspection completion.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 5 May 2017 Resolved
Obtain & post EAP information onboard.
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 5 May 2017
Resolution: EAP information posted.
Communications › Alarms/Indicators › Bilge Alarm
Issued 5 May 2017 Resolved
Provide labeling for bilge alarm notification in pilot house.
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 5 May 2017
Resolution: Spaces properly labeled for high level alarm notification.
Documentation › Certificates/Documents › Stability Letter
Issued 5 May 2017 Resolved
Post stability letter under glass.
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 5 May 2017
Resolution: Stability letter posted.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 5 May 2017 Resolved
Install 02 smoke detectors in crew and passenger sleeping accommodations.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 5 May 2017
Resolution: Smoke detectors installed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 5 May 2017 Resolved
Shorten floating waterlight tether to appropriate length.
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 5 May 2017
Resolution: floating water light tether shortened to proper length.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 May 2017 Resolved
remove plastic zipties and use metallic means of securing wire runs in engine room.
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 5 May 2017
Resolution: Metallic means utilized to anchor wiring.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 May 2017 Resolved
Replace burnt out masthead and stern lights with functional bulbs.
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 5 May 2017
Resolution: Fresh bulbs installed.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 24 February 2017 Resolved
Vessel is overdue for inspection. No-sail imposed. Vessel must complete inspections and receive new COI prior to operating as a commercial vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2017
Resolved 5 May 2017
Resolution: Vessel successfully completed inspection for COI.
Lifesaving › Lifebuoys › Immediately Available
Issued 7 March 2016 Resolved
Provide readily accessible location for third ring buoy IAW 46 CFR 180.70
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 13 April 2016
Resolution: Vessel crew moved one of the three ring buoys to the main deck, all satisfactory.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 7 March 2016 Resolved
Provide emergency escape markings for galley hatch "EMERGENCY EXIT, KEEP CLEAR", both sides IAW 46 CFR 185.606.
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 13 April 2016
Resolution: Vessel crew provided proper markings for emergency escape hatch, all satisfactory.
Engineering › Bilge Water Management System › Piping
Issued 27 January 2016 Resolved
Replace bilge line to bunkroom as original.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 January 2016
Resolved 18 February 2016
Resolution: O/O installed new bilge line to bunkroom.
Construction/Loadline › Hull › Hull Plating
Issued 27 January 2016 Resolved
Crop and renew backing block for PTO bilge pump OVBD through hull.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 January 2016
Resolved 18 February 2016
Resolution: O/O repaired backing block.
Construction/Loadline › Hull › Stiffener
Issued 27 January 2016 Resolved
Replace wasted bolt in transom stiffener.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 January 2016
Resolved 18 February 2016
Resolution: O/O installed new bolt adjacent to existing.
Construction/Loadline › Hull › Longitudinal Frame
Issued 27 January 2016 Resolved
Crop and renew wood around bolt on port side clamp in Laz.
Action required: 705 - Other - as specified
Due 29 January 2016
Resolved 18 February 2016
Resolution: O/O treated wood and repaired area with epoxy.
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 23 February 2012 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 23 March 2012
Resolved 23 March 2012
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 23 February 2012 Resolved
Rejected (4) adult PFDs due to deteriorated condition.
Action required: 705 - Other - as specified
Due 23 March 2012
Resolved 23 February 2012
Resolution: This was corrected on the spot when vessel provided new spare lifejackets from their storage.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 2 March 2009 Resolved
Renew wasted raw water discharge piping for stbd main engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 April 2009
Resolved 30 March 2009
Resolution: New pipe installed.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 2 March 2009 Resolved
Repair exhuast leaks on stbbd main engine & port generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 April 2009
Resolved 30 March 2009
Resolution: Replaced exhaust hose on Starboard main generator, and tightened hose clamps on Port generator exhaust.
Engineering › Steering Gear System › Fastener
Issued 2 March 2009 Resolved
Provide new bolts to steering gear foundation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 April 2009
Resolved 30 March 2009
Resolution: Installed 03 new through bolts on either side of both Port and Starboard steering gear mounts.
Communications › Alarms/Indicators › Bilge Alarm
Issued 28 February 2008 Resolved
Provide a bilge alarm for the passenger bunkroom and demonstrate proper operation IAW 46 CFR 182.530
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 March 2008
Resolved 7 March 2008
Resolution: Bilge alarm installed and verified operational.
Electrical › Lighting (service) › Lighting Fixture
Issued 28 February 2008 Resolved
Mount light fixture in crew bunkroom IAW 46 CFR 183.410
Action required: 705 - Other - as specified
Due 28 March 2008
Resolved 7 March 2008
Resolution: Light fixture installed.
Electrical › Lighting (service) › Lighting Fixture
Issued 28 February 2008 Resolved
Provide light diffuser / protective covers for all of the engine room lights IAW 46 CFR 183.410
Action required: 705 - Other - as specified
Due 11 April 2008
Resolved 8 April 2008
Resolution: Light diffuser/protective covers provided for all of the engine room lights.
Electrical › Electrical Distribution System (service) › Cable
Issued 28 February 2008 Resolved
Make electrical cable connection secure to junction box in forward crew bunkroom IAW 46 CFR 183.200
Action required: 705 - Other - as specified
Due 28 March 2008
Resolved 7 March 2008
Resolution: Electrical cable secured to junction box.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 28 February 2008 Resolved
Provide 02 type I PFD's. Passenger count reduced to a maximum of 104 persons.
Action required: 705 - Other - as specified
Due 28 March 2008
Resolved 7 March 2008
Engineering › Bilge Water Management System › Pump
Issued 28 February 2008 Resolved
Provide 02 fixed power bilge pumps and demonstrate proper operation IAW 46 CFR 182.520
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 March 2008
Resolved 7 March 2008
Engineering › Bilge Water Management System › Valve
Issued 28 November 2007 Resolved
Replace bilge shut off valve at collision Bulkhead.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 February 2008
Resolved 11 February 2008
Resolution: Bilge shut off valve at collision bulkhead was replaced.
Fire Fighting › Fire Main › Material
Issued 7 March 2007 Resolved
Fire Main utilized PVC pipe in lieu of required metallic piping.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2007
Resolved 28 November 2007
Resolution: Fire main replaced with metallic piping.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 7 March 2007 Resolved
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2007
Resolved 28 November 2007
Resolution: Sewage System Valve replaced.
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 March 2006 Resolved
Repair inoperable bilge alarms for the Lazarette and main accommodation spaces.
Action required: 705 - Other - as specified
Due 6 March 2006
Resolved 7 March 2006
Resolution: Tested all bilge alarms.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 6 March 2006 Resolved
Re-label all lifejacket storage areas in the main cabin. Ensure that child size lifejackets are stored in a separate location.
Action required: 705 - Other - as specified
Due 6 April 2006
Resolved 6 April 2006
Resolution: All lifejacket storage containers were properly labeled.
Electrical › Lighting (service) › Lighting Fixture
Issued 6 March 2006 Resolved
Install covers for lights located in the engine room, galley and accommodation spaces.
Action required: 705 - Other - as specified
Due 6 April 2006
Resolved 6 April 2006
Resolution: Light covers were installed.
Engineering › Steering Gear System › Hydraulic Hose
Issued 10 March 2005 Resolved
Hydraulic hoses need to be replaced in steering gear room due to blistering
Condition: Unknown
Due 30 April 2005
Resolved 20 April 2005
Resolution: Replaced port and starboard hydraulic hoses.
Lifesaving › Buoyant Apparatus
Issued 3 March 2004 Resolved
Replace both painter on life floats.
Condition: Improper/Lack of Maintenance
Due 3 March 2004
Resolved 3 March 2004
Fire Fighting › Ventilation Systems › Ducts
Issued 18 March 2003 Resolved
No engine room ventilation covers for enginge room ventilation.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 18 March 2003
Resolution: Provided satisfactory ventilation covers for engine room ventilation.
Documentation › Markings/Placards
Issued 18 March 2003 Resolved
No oil discharge placard per 33 CFR 155.450. LEGACY COMPONENT DESC: Oil Discharge Placard
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 March 2003
Resolved 18 March 2003
Resolution: Installed oil discharge placard.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 6 March 2002 Resolved
Unlabeled PFD cabinet; corrected on the spot.
Due 6 March 2002
Resolved 6 March 2002
Engineering › Bilge Water Management System
Issued 6 March 2002 Resolved
Missing valve labels; corrected on the spot. LEGACY COMPONENT DESC: Manifold
Due 6 March 2002
Resolved 6 March 2002
Engineering › Bilge Water Management System
Issued 6 March 2002 Resolved
Unlabeled visual alarms for automatic Rule pumps; corrected on the spot. LEGACY COMPONENT DESC: Interface Detector
Due 6 March 2002
Resolved 6 March 2002
Construction/Loadline › Hull › Stringer
Issued 12 December 2001 Resolved
Renew as original #5 port & starboard deck stringer in lazzarette, due to rot.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 December 2001
Resolved 26 December 2001
Resolution: Stringers renewed as original.
Construction/Loadline › Hull › Keel
Issued 12 December 2001 Resolved
Tighten Keel bolts in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 December 2001
Resolved 26 December 2001
Resolution: Keel bolts tightenned.
Construction/Loadline › Hull › Longitudinal Frame
Issued 12 December 2001 Resolved
Recaulk keel to hull seam in way of stbd bunk room.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 December 2001
Resolved 26 December 2001
Resolution: Keel to hull seam recaulked.
Construction/Loadline
Issued 6 March 2001 Resolved
Ensure bilge high level alarm in lazarette is operable prior to carriage ofpassengers.
Condition: Unknown
Due 27 November 2001
Resolved 27 November 2001
Unknown
Issued 4 August 2000 Resolved
Replace flex hose on port side generator's exhaust line located in the lazarette.
Condition: Unknown
Due 26 November 2001
Resolved 26 November 2001
Engineering
Issued 4 August 2000 Resolved
Ensure starboard shaft is properly mounted or packing gland is properly installed so that no smoke is created due to normal use of starboard engine. There is excessive smoke coming out of starboard shaft packing gland when shaft is turning.
Condition: Unknown
Due 26 November 2001
Resolved 26 November 2001
Construction/Loadline
Issued 3 August 2000 Resolved
PRIOR TO CARRYING PASSENGERS MAKE REPAIRS TO HULL TO THE SATISFACTION OF THE COGNIZANT USCG MARINE INSPECTOR.
Condition: Unknown
Due 3 August 2000
Resolved 3 August 2000
Construction/Loadline
Issued 24 March 1999 Resolved
Provide audible alarm at the operating station for bilge high level alarms in water tight spaces.
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Navigation
Issued 25 January 1999 Resolved
Repair port side rudder post.
Condition: Unknown
Due 5 February 1999
Resolved 25 February 1999
Construction/Loadline
Issued 25 January 1999 Resolved
Scrape and treat rot on port side corner stern.
Condition: Unknown
Due 5 February 1999
Resolved 25 February 1999
Construction/Loadline
Issued 25 January 1999 Resolved
Scrape and treat rot on stem above waterline.
Condition: Unknown
Due 5 February 1999
Resolved 25 February 1999
Construction/Loadline
Issued 25 January 1999 Resolved
Scrape and treat rot on stbd. side engine room longitudinal.
Condition: Unknown
Due 5 February 1999
Resolved 25 February 1999
Construction/Loadline
Issued 25 January 1999 Resolved
Scrape and treat rot on engine room coaming.
Condition: Unknown
Due 5 February 1999
Resolved 25 February 1999
Construction/Loadline
Issued 25 January 1999 Resolved
Scrape and treat port side longitudinal in steering space.
Condition: Unknown
Due 5 February 1999
Resolved 25 February 1999
Construction/Loadline
Issued 25 January 1999 Resolved
Wrote requirement not to carry passengers for hire until a check ride was conducted.
Condition: Unknown
Due 5 March 1999
Resolved 25 February 1999
Construction/Loadline
Issued 18 March 1998 Resolved
Remove flex hose from collision bulkhead. Replace with metallic fitting.
Condition: Unknown
Due 26 March 1998
Resolved 26 March 1998
Construction/Loadline
Issued 18 March 1998 Resolved
Repair gap between number one and two plank. Make water tight. Starboard side. Achor locker.
Condition: Unknown
Due 26 March 1998
Resolved 26 March 1998
Construction/Loadline
Issued 18 March 1998 Resolved
Make collision bulkhead water tight.
Condition: Unknown
Due 26 March 1998
Resolved 26 March 1998
Electrical
Issued 18 March 1998 Resolved
Provide light covers though out vessel.
Condition: Unknown
Due 26 March 1998
Resolved 26 March 1998
Construction/Loadline
Issued 29 October 1997 Resolved
EXCESSIVE OIL IN BILGE.
Condition: Unknown
Due 30 October 1997
Resolved 3 November 1997
Accommodation/Occupational Safety
Issued 28 March 1996 Resolved
Provide a relief valve for the hot water heater tank in the engine room.
Condition: Unknown
Due 4 April 1996
Resolved 4 April 1996
Fire Fighting
Issued 28 March 1996 Resolved
Prior to carrying passengers for hire, service the fixed CO2 system in the engine room.
Condition: Unknown
Due 28 March 1996
Resolved 28 March 1996
Navigation
Issued 28 March 1996 Resolved
Make corrections to the vessel's navigational charts and publications through the latest Notice to Mariners.
Condition: Unknown
Due 4 April 1996
Resolved 4 April 1996
Accommodation/Occupational Safety
Issued 28 March 1996 Resolved
Prove proper operation of the emergency lighting below deck. Until the lighting is repaired the roving patrol shall carry at least two sources of lighting.
Condition: Unknown
Due 28 March 1996
Resolved 28 March 1996
Construction/Loadline
Issued 15 February 1996 Resolved
VESSEL'S WATERTIGHT INTEGRITY NEEDED TO BE EXAMINED WHILE UNDERWAY FOLLOWING THE HULL EXAM.
Condition: Unknown
Due 15 February 1996
Resolved 15 February 1996
Navigation
Issued 30 August 1995 Resolved
PROVIDE FCC REGULATIONS
Condition: Unknown
Due 30 August 1995
Resolved 30 August 1995
Documentation
Issued 30 August 1995 Resolved
PROVIDE STABILITY LETTER.
Condition: Unknown
Due 30 August 1995
Resolved 30 August 1995
Navigation
Issued 30 August 1995 Resolved
PROVIDE CORRECTED CHARTS AND PUBS.
Condition: Unknown
Due 30 August 1995
Resolved 30 August 1995
Construction/Loadline
Issued 31 August 1994 Resolved
AT NEXT DRYDOCK, INSTALL PERMANENT DRAFT MARKS OR LOADING MARKS.
Condition: Unknown
Due 31 August 1994
Resolved 31 August 1994
Accommodation/Occupational Safety
Issued 31 August 1994 Resolved
PROVE PROPER OPERATION OF MSD OVERBOARD VALVES AND PROPERLY SECURE VALVES.
Condition: Unknown
Due 31 August 1994
Resolved 31 August 1994
Accommodation/Occupational Safety
Issued 31 August 1994 Resolved
PROVE MSD HOLDING TANK IS OF SUFFICIENT SIZE.
Condition: Unknown
Due 31 August 1994
Resolved 31 August 1994
Fire Fighting
Issued 31 August 1994 Resolved
INSTALL GAUGE ON FIRE PUMP.
Condition: Unknown
Due 31 August 1994
Resolved 31 August 1994
Construction/Loadline
Issued 31 August 1994 Resolved
REMOVE OIL FROM BILGE.
Condition: Unknown
Due 7 September 1994
Resolved 7 September 1994
Navigation
Issued 31 August 1994 Resolved
PROVIDE UPDATED CHARTS.
Condition: Unknown
Due 31 August 1994
Resolved 31 August 1994
Electrical
Issued 31 August 1994 Resolved
PROVE PROPER OPERATION OF PORT AND STARBOARD GENERATOR GUAGES.
Condition: Unknown
Due 7 September 1994
Resolved 7 September 1994
Electrical
Issued 31 August 1994 Resolved
PROVIDE AMP METER FOR PORT GENERATOR.
Condition: Unknown
Due 7 September 1994
Resolved 7 September 1994
Engineering
Issued 31 August 1994 Resolved
PROVIDE PROPER FUEL STRAINER IN ACCORDANCE WITH 46 CFR 182.20-40(B)(5).
Condition: Unknown
Due 7 September 1994
Resolved 7 September 1994
Electrical
Issued 31 August 1994 Resolved
RENEW AS ORIGINAL 110V WIRE FOR FLOOD LIGHTS RUNNING BETWEEN CIRCUIT BREAKER PANEL AND JUNCTION BOX. VESSEL IS NOT TO OPERATE UNTIL WIRE RUN ISRENEWED.
Condition: Unknown
Due 7 September 1994
Resolved 7 September 1994
Electrical
Issued 8 November 1993 Resolved
PROPERLY INSTALL ONE (1) 15 AMPS CIRCUIT BREAKER FOR THE PROTECTION OF THE EMERGENCY LIGHTING SYSTEM.
Condition: Unknown
Due 8 November 1993
Resolved 8 November 1993
Documentation
Issued 3 September 1993 Resolved
PROVIDE APPROVED PLANS FOR THE NEW ELECTRICAL SYSTEM._x001C_ _x001C_
Condition: Unknown
Due 3 September 1993
Resolved 3 September 1993
Construction/Loadline
Issued 3 September 1993 Resolved
MAKE 2ND TRANSVERSE WATERTIGHT BULKHEAD FROM BOW WATERTIGHT.
Condition: Unknown
Due 1 October 1993
Resolved 1 October 1993
Construction/Loadline
Issued 3 September 1993 Resolved
TREAT DRY ROT IN ENGINE ROOM.
Condition: Unknown
Due 1 October 1993
Resolved 1 October 1993
Electrical
Issued 5 February 1993 Resolved
PROVIDE PLANS AND PROVE PROPER ELECTRICAL OPERATION OF THE VESSEL PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 5 February 1993
Resolved 5 February 1993
Accommodation/Occupational Safety
Issued 15 October 1992 Resolved
PROVIDE POSTED INSTRUCTIONS FOR THE USE OF THE MSD SYSTEM, LIMITING THE FLUSHING TIME. INSTRUCTIONS ARE TO BE POSTED IN BOTH HEADS.
Condition: Unknown
Due 15 October 1992
Resolved 15 October 1992
Electrical
Issued 17 September 1992 Resolved
INSTALL A GUARD OVER THE DRIVE BELT ON THE INBOARD END OF THE STARBOARD GENERATOR.
Condition: Unknown
Due 17 September 1992
Resolved 17 September 1992
Accommodation/Occupational Safety
Issued 17 September 1992 Resolved
PROVE PROPER OPERATION OF THE SEWAGE SYSTEM, INCLUDING THE ABILITY TO RETAIN SEWAGE IN THE HOLDING TANK DURING NORMAL OPERATIONS.
Condition: Unknown
Due 17 September 1992
Resolved 17 September 1992
Fire Fighting
Issued 21 April 1992 Resolved
PROVIDE PRESSURE GAUGE ON THE OUTPUT SIDE OF FIRE PUMP.
Condition: Unknown
Due 21 April 1992
Resolved 21 April 1992
Navigation
Issued 21 April 1992 Resolved
PROVIDE REQUIRED NAUTICAL PUBS AS PER 46 CFR 185.20-35.
Condition: Unknown
Due 21 April 1992
Resolved 21 April 1992
Electrical
Issued 21 April 1992 Resolved
PROVIDE ELECTRICAL SCHEMATIC (DIAGRAM) OF ALL NEW ELECTRICAL INSTALLATIONS TO THE LOCAL OCMI FOR REVIEW AND APPROVAL.
Condition: Unknown
Due 21 April 1992
Resolved 21 April 1992
Accommodation/Occupational Safety
Issued 21 April 1992 Resolved
REPLACE BROKEN WINDOWS IN THE PILOT HOUSE.
Condition: Unknown
Due 21 April 1992
Resolved 21 April 1992
Lifesaving
Issued 21 April 1992 Resolved
PROPERLY STENCIL LIFE FLOAT CAPACITY.
Condition: Unknown
Due 21 April 1992
Resolved 21 April 1992
Engineering
Issued 21 April 1992 Resolved
PROVIDE GROUNDING WIRE FOR FUEL TANK FILL PIPE (PORT SIDE WING TANK).
Condition: Unknown
Due 21 April 1992
Resolved 21 April 1992
Construction/Loadline
Issued 21 April 1992 Resolved
CLEAN AND TREAT DRY ROT IN ENGINE ROOM AS NEEDED.
Condition: Unknown
Due 21 April 1992
Resolved 21 April 1992
Electrical
Issued 21 April 1992 Resolved
REMOVE ELECTRICAL WIRE FOR STERN LIGHT FROM BATTERY TERMINALS.
Condition: Unknown
Due 21 April 1992
Resolved 21 April 1992
Unknown
Issued 21 April 1992 Resolved
PROVE PROPER OPERATION OF HOT WATER HEATER SAFETY RELIEF.
Condition: Unknown
Due 21 April 1992
Resolved 21 April 1992
Electrical
Issued 21 April 1992 Resolved
LABEL CIRCUIT BREAKER PANELS AS NEEDED.
Condition: Unknown
Due 21 April 1992
Resolved 21 April 1992
Construction/Loadline
Issued 21 April 1992 Resolved
SEAL HOLES IN COLLISION BULKHEAD AS NEEDED (HOLES IN UPPER PART OF BULKHEAD).
Condition: Unknown
Due 21 April 1992
Resolved 21 April 1992
Lifesaving
Issued 21 April 1992 Resolved
APPLY SUFFICIENT RETRO REFLECTIVE TAPE TO ALL LIFE FLOATS.
Condition: Unknown
Due 21 April 1992
Resolved 21 April 1992
Navigation
Issued 21 April 1992 Resolved
PROVIDE LATEST CHANGES TO CHARTS FOR THE AREA OF OPERATION.
Condition: Unknown
Due 21 April 1992
Resolved 21 April 1992
Engineering
Issued 21 April 1992 Resolved
PROVE INTEGRITY OF BOTH AFT FUEL TANKS
Condition: Unknown
Due 21 April 1992
Resolved 21 April 1992
Electrical
Issued 21 April 1992 Resolved
REMOVE WIRE FOR STARBOARD RUNNING LIGHT AND REPLACE WITH MARINE GRADE WIRE.
Condition: Unknown
Due 21 April 1992
Resolved 21 April 1992
Engineering
Issued 21 April 1992 Resolved
REPAIR FUEL DRIVE OIL GAUGE (PORT ENGINE) IN PILOT HOUSE.
Condition: Unknown
Due 21 April 1992
Resolved 21 April 1992
Electrical
Issued 21 April 1992 Resolved
PROPERLY TERMINATE WIRE FOR KING VHF RADIO.
Condition: Unknown
Due 21 April 1992
Resolved 21 April 1992
Construction/Loadline
Issued 23 April 1991 Resolved
REPLACE BROKEN WINDOWS THROUGHOUT THE VESSEL.
Condition: Unknown
Due 23 April 1991
Resolved 23 April 1991
Documentation
Issued 26 June 1990 Resolved
PROVIDE PROOF OF CURRENT RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 26 June 1990
Resolved 26 June 1990
Documentation
Issued 4 May 1990 Resolved
PROVIDE PROOF OF CURRENT RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 4 May 1990
Resolved 4 May 1990
Engineering
Issued 4 May 1990 Resolved
PROVE PROPER OPERATION OF STBD MAIN DIESEL ENGINE TACHOMETER.
Condition: Unknown
Due 4 May 1990
Resolved 4 May 1990
Engineering
Issued 4 May 1990 Resolved
LABEL BILGE MANIFOLD.
Condition: Unknown
Due 4 May 1990
Resolved 4 May 1990
Electrical
Issued 4 May 1990 Resolved
PROVIDE COVERS FOR EXPOSED LIGHTS BULBS IN GALLEY, PASSENGER BERTHING, AND SUN DECK.
Condition: Unknown
Due 4 May 1990
Resolved 4 May 1990
Electrical
Issued 7 December 1989 Resolved
PROVIDE CLOSURES FOR OPEN AREAS IN CIRCUIT BREAKER BOX IN HOT WATER TANK COMPARTMENT.
Condition: Unknown
Due 7 December 1989
Resolved 7 December 1989
Construction/Loadline
Issued 7 December 1989 Resolved
MAKE WATERTIGHT PENETRATION MADE BY REMOVED STEERING COLUMN, CENTERLINE, AFT BULKHEAD IN ENGINE ROOM.
Condition: Unknown
Due 7 December 1989
Resolved 7 December 1989
Construction/Loadline
Issued 7 December 1989 Resolved
CLEAN AND TREAT ROT IN ENGINE ROOM: (1) UNDERDECK AREA ABOVE OIL TANK AND (2)UNDERDECK BEAM FORWARD OF HATCH, BEAM IS TO BE SISTERED. CLEAN AND TREAT ROT IN LAZARETTE ON FUEL TANK BLOCKS AND STRUT BLOCKS.
Condition: Unknown
Due 7 December 1989
Resolved 7 December 1989
Lifesaving
Issued 9 May 1989 Resolved
PROVIDE VESSEL WITH 12 4-FOOT PADDLES FOR LIFEFLOATS IN ACCORDANCE WITH 46 CFR 180.15-5(B).
Condition: Unknown
Due 9 May 1989
Resolved 9 May 1989
Lifesaving
Issued 9 May 1989 Resolved
RENEW NET ON 6-PERSON LIFEFLOAT.
Condition: Unknown
Due 9 May 1989
Resolved 9 May 1989
Fire Fighting
Issued 9 May 1989 Resolved
PROVIDE VESSEL WITH ONE ADDITIONAL B-II AND INSTALL.
Condition: Unknown
Due 9 May 1989
Resolved 9 May 1989
Construction/Loadline
Issued 9 May 1989 Resolved
PROVIDE CAPTURE DEVICES FOR VESSELS ON-DECK HATCH/SCUTTLES.
Condition: Unknown
Due 9 May 1989
Resolved 9 May 1989
Accommodation/Occupational Safety
Issued 9 May 1989 Resolved
PROVIDE HANDLE FOR VALVE FOR BILGE SUCTION LINE FOR FOREPEAK.
Condition: Unknown
Due 9 May 1989
Resolved 9 May 1989
Fire Fighting
Issued 9 May 1989 Resolved
PROVIDE VESSEL WITH FIRE HOSE NOZZLES IN ACCORDANCE WITH 46 CFR 181.15-10(D)(2).
Condition: Unknown
Due 9 May 1989
Resolved 9 May 1989
Electrical
Issued 9 May 1989 Resolved
PROPERLY WIRE FREEZER TO VESSEL'S ELECTRICAL SYSTEM.
Condition: Unknown
Due 9 May 1989
Resolved 9 May 1989
Navigation
Issued 12 May 1988 Resolved
REPLACE SOCKET BALL JOINTS FOR BOTH TILLER ARMS.
Condition: Unknown
Due 12 May 1988
Resolved 12 May 1988
Engineering
Issued 12 May 1988 Resolved
REPLACE FUEL TANKS EQUALIZING HOSE.
Condition: Unknown
Due 12 May 1988
Resolved 12 May 1988
Lifesaving
Issued 12 May 1988 Resolved
REPLACE BOTH FLOAT-FREE LINKS.
Condition: Unknown
Due 12 May 1988
Resolved 12 May 1988
Unknown
Issued 12 May 1988 Resolved
COMPLETE 5 ITEM WORKLIST.
Condition: Unknown
Due 12 May 1988
Resolved 12 May 1988
Lifesaving
Issued 17 May 1985 Resolved
PROVIDE LABELING FOR ALL LIFE JACKET STOWAGE AREAS WITH SIZE AND NUMBER.
Condition: Unknown
Due 17 May 1985
Resolved 17 May 1985
Construction/Loadline
Issued 17 May 1985 Resolved
RENEW STARBOARD WHEELHOUSE WINDOW.
Condition: Unknown
Due 17 May 1985
Resolved 17 May 1985
Electrical
Issued 17 May 1985 Resolved
PROVIDE WIRE CLAMOS AND MOUNT WHEELHOUSE BATTERY CHARGER IN SAFE AREA AWAY FROM BUNKS
Condition: Unknown
Due 17 May 1985
Resolved 17 May 1985

Casualty record · 5

1 July 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 2424345
18 June 2011Routine · role: Involved in a Marine Casualty · activity 4072029
1 December 2017Routine · role: Involved in a Marine Casualty · activity 6318045
18 August 2019Routine · role: Involved in a Marine Casualty · activity 6790879
20 August 2022Routine · role: Involved in a Marine Casualty · activity 7542991
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.