MAURY USCG vessel records
← All vessels

MSC JEANNE

MSC JEANNE is a 1996 freight ship. The Coast Guard has recorded 51 inspections since 2016, most recently in March 2022, along with 10 deficiencies and 27 operational controls, 1 with no removal date recorded.

Records from 2016 to 2022. Most recent: inspection, 4 March 2022.

Built
1996
Last inspected
4 March 2022
Documentation
Not in the documentation file of 10 August 2026
Controls
1 with no removal date recorded

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 4 March 2022
…with no type recorded32
Operational controls 1 with no removal date recorded
Years with a record 6 calendar years (2016–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9135638
441460
Flag
LIBERIA
Maury page id
psix-441460

Documentation record

Tonnage as PSIX records it35020 - Dead Weight, Ton
45877 - Displacement, Ton
29022 - Convention (Subpart B), Gross Ton
16570 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 51

4 March 2022 PSC A · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7405733
27 February 2022 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7402638
12 January 2022 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7379307
10 January 2022 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7377871
4 January 2022 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7375405
16 December 2021 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7368939
2 December 2021 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7361718
11 November 2021 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7360078
4 November 2021 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7345663
31 October 2021 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7342638
31 October 2021 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7342640
27 August 2021 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7298175
26 August 2021 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7297260
26 August 2021 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7297561
22 August 2021 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7293374
28 June 2021 PSC A
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7238212
28 June 2021 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7238521
25 June 2021 Ballast Water Examination · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7235936
23 June 2021 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7233696
23 June 2021 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7233922
21 June 2021 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7232382
20 June 2021 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7230213
24 April 2021 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7181833
21 April 2021 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7180123
20 April 2021 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7179193
19 April 2021 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7178376
14 April 2021 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7175219
17 February 2021 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7141585
10 February 2021 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7138509
5 December 2020 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7106690
2 December 2020 PSC A · Ballast Water Examination · MARPOL Annex VI Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7104781
2 December 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7104868
1 December 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7104158
28 November 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7102716
12 April 2018 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6393856
8 April 2018 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6388022
30 March 2018 ISPS II Exam · Ballast Water Examination · PII Safety Exam · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6381714
30 March 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6382008
11 October 2017 Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6285271
19 June 2017 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6180646
21 April 2017 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6129902
1 March 2017 Deficiency Check · Damage Survey
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6097277
1 March 2017 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6097615
25 February 2017 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6094806
22 February 2017 ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6092157
13 July 2016 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5939085
19 May 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5880846
19 May 2016 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 5881082
16 May 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5878850
4 January 2016 NPV Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5790855
4 January 2016 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5800236

Deficiency record · 10

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 25 June 2021 Resolved
In a ship in which oil fuel is used, the arrangements for the safety, storage, distribution, and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. Multiple oil leaks and oil accumulation found throughout the engine room and steering gear room. 74 SOLAS (97) II-2/15.2, 74 SOLAS (97) II-2/15.4
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2021
Resolution: Vessel sent proof of rectification
07 - Fire Safety › N/A - No Subsystem › Jacketed high pressure lines and oil leakage alarm
Issued 25 June 2021 Resolved
In a ship in which oil fuel is used, the arrangements for the safety, storage, distribution, and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. No. 2 high pressure fuel line is leaking excessively. 74 SOLAS (97) II-2/15.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2021
Resolution: Vessel sent proof of rectification.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 25 June 2021 Resolved
The company and the ship shall comply with the requirements of the ISM code. The company should establish procedures, plans, and instructions, including checklists, for key shipboard operations concerning the safety of the personnel, ship, and the environment. "ENGINE ROOM DAILY TESTS AND CHECKS" chcklist does not inclue check and/or emptying bottles and buckets collecting leaking oil in engine room and steering gear room, nor has the cause of leaking oil and accumulation thereof been permanently addressed. 74 SOLAS (14) IX/3.1 ISM A/7
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 November 2021
Resolution: Vessel sent proof of rectification. Crew is ensuring that Tech 20 report is being used to track discrepancies as according their SMS.
Electrical › Electric Generation Source (service) › Number of Sources
Issued 7 April 2018 Resolved
A main source of electrical power of sufficient capacity to supply all services shall be provided. This main source of power shall consist of at least two generator sets. Vessel only has made temporary arrangement to allow for use of powerpack system as second generator set. Vessel must make permanent repairs to #1 and #3 generators. 74SOLAS('04) II-1 Reg. 41.1.1 Action: 17.c
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 December 2020
Resolution: During PSCA exam conducted 02DEC2020 all 3 generators were found in operable condition.
Engineering › Generator (propulsion/auxiliary-electric) › Wiring
Issued 30 March 2018 Resolved
A main source of electrical power of sufficient capacity to supply all services shall be provided. This main source of power shall consist of at least two generator sets. Vessel only has one operable generator set. 74SOLAS('04) II-1 Reg. 41.1.1 Action: 17.c
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 30 March 2018
Resolved 7 April 2018
Resolution: See narrative.
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 19 June 2017 Resolved
9900- If your voyage time is less than 96 hours the NOA must be submitted at least 24 hours before entering the port or place of destination. The vessel entered the COTP zone without providing a NOA within the appropriate timeframe. 33CFR160.212(a)(3)(ii)
Action required: 705 - Other - as specified
Resolved 8 August 2017
Engineering › Electric Propulsion System › Remote Control Circutry
Issued 1 March 2017 Resolved
Ship's Remote Control System, from bridge and ECR, is inoperable and unable to communicate commands to the main engine. SOLAS, CH.1, Reg. 11(a)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 April 2017
Resolution: Recieved class report attesting to proper repairs.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 22 February 2017 Resolved
0750: THE FIRE RESISTANCE OF DOORS SHALL BE EQUIVALENT TO THAT OF THE DIVISION IN WHICH THEY ARE FITTED. CLASS "A" SELF-CLOSING FIRE DOOR LEADING FROM GALLEY TO CREW MESS ROOM WAS FITTED WITH A HOLD BACK HOOK WHICH CAUSED CRACKING AND DAMAGE TO DOOR, LEADING TO THE COMPROMISE OF THE BOUNDARY'S FIRE RESISTANCE. 74 SOLAS (97) II-2/47.1 CODE 16A
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 March 2017
Resolved 21 April 2017
Resolution: Recieved Class Report attesting to replacement of Class A Door.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 22 February 2017 Resolved
0750: DOORS REQUIRED TO BE SELF CLOSING SHALL NOT BE FITED WITH HOLD BACK HOOKS. CLASS "A" SELF-CLOSING DOOR LEADING FROM THE GALLEY TO THE PROVISIONS ROOMS WAS FITTED WITH A PERMANENT HOLD BACK HOOK. 74 SOLAS (97) II-2/47.2 CODE 10C.
Condition: Improper Installation
Due 22 February 2017
Resolved 22 February 2017
Resolution: CREW GRINDED OF THE WELDED ON HOLD BACK HOOK SET UP TO PREVENT REATTACHMENT AFTER EXAMINATION.
Engineering › Compressed Air System (start air) › Valve
Issued 4 January 2016 Resolved
Vessel encountered a loss of main propulsion while getting underway and could not restart the main diesel engine due to a start air distributor valve not functioning.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 January 2016
Resolution: Vessel submitted class report attesting to the repairs of the start air distibutor valve.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.