MAURY USCG vessel records Sign in
← All vessels

MSC SAMANTHA VI

MSC SAMANTHA VI is a 1996 freight ship. The Coast Guard has recorded 30 inspections since 1996, most recently in July 2024, along with 19 deficiencies — 1 with no resolution recorded — and 1 operational control.

Records from 1996 to 2024. Most recent: operational control imposed, 27 July 2024.

Built
1996
Last inspected
27 July 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9110377 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
441509
Flag
PANAMA
—
Maury page id
psix-441509

Inspections, by type

…with no type recorded17
Years with a record 11 calendar years (1996–2024)
The 30 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it68539 - Dead Weight, Ton
64054 - Convention (Subpart B), Gross Ton
37655 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

APL SINGAPORE Freight Ship · MISLE 433131 · 16 January 2006 · activity 3159554

Inspection history · 30

27 July 2024 Deficiency Check · Appeal · PSC A
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7968002
13 March 2024 PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7878200
4 March 2024 PSC A
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7873074
12 February 2012 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4242908
9 February 2012 Ballast Water Examination · NPV Safety Exam · ISPS III Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4240960
1 December 2008 ISPS III Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3372214
3 August 2008 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3288243
7 July 2008 PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3258787
24 July 2007 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3006495
17 June 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2966137
16 June 2007 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2963401
10 May 2007 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2927283
10 April 2007 Type not recorded
No type recorded · Maritime Safety & Security Team San Francisco (91105) · Activity 2905106
6 March 2007 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2882780
31 January 2007 Random ISPS/MTSA-No PSC
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2864704
3 August 2006 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2735448
31 May 2006 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2666131
27 May 2006 PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2660732
16 January 2006 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3159554
16 February 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 287271
2 October 2000 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 282713
3 March 2000 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 275475
16 September 1999 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 432680
22 March 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 426779
25 September 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 420809
9 May 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 415758
22 December 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 411189
23 May 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 404073
6 January 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 399186
29 June 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 392808

Deficiency record · 19

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 27 July 2024 Resolved
The company and the ship shall comply w/ the requirement of the ISM Code. The company should establish procedures to ensure that the ship is maintained in conformity w/ the provisions of the relevant rules and regulations. The technical and operational nature of deficiencies 02,03,04,05,06, and 07 provide objective evidence of a serious failure of the implementation of the ISM Code. 74SOLAS(20) IX/3 ISM 10.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 30 July 2024
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 27 July 2024 Resolved
Hydraulic power-operated steering gear shall be provided w/ the following: A fixed storage tank having sufficient capacity to recharge at least one power actuating system including the reservoir. PSCO observed tank leaking, with only 1/4 of the required oil inside. 74SOLAS(01) II-1/29.12.3
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 30 July 2024
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 27 July 2024 No resolution recorded
Hydraulic power operated steering gear shall be provided w/ the following: Arrangement to maintain the cleanliness of the hydraulic fluid. PSCO observed hydraulic leaks on both #1 & #2 steering gear systems. Including #3 and #4 gear rams. 74SOLAS(01) II-1/29-12.2
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 27 July 2024 Resolved
The company and the ship shall comply w/ the requirements of the ISM Code. The Company should establish procedures, plans and instructions, including checklists as appropriate, for key shipboard operations concerning the safety of personnel. PSCO observed lock-out/tag-out procedures not being followed as per Company SMS procedures. #1 diesel generator was not tagged out in accordance with SMS as breaker was not tagged out in the open position and not tagged out in the open position and start air valve was not tagged out in closed position. Also #2 boiler water circ. pump was not tagged out properly as the breaker was not secured in the open position. 74SOLAS(20) IX/3 ISM 7
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 July 2024
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 27 July 2024 Resolved
Indicators shall be provided for all sliding doors and for hinged doors in watertight bulkheads. PSCO observed indicators for the port watertight door from E/R to cargo tunnel not operational. Observed indicators for both port and starboard water tight doors from E/R to cargo tunnel found not operational on the bridge. 74SOLAS(01) II-1/23-1.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 July 2024
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 27 July 2024 Resolved
Watertight trunks shall be of the same strength as watertight bulkheads at corresponding levels. The means used for making them watertight, and the arrangements adopted for closing openings in them, shall be to the satisfaction of the Administration. PSCO Observed watertight rolling door to aft engine room inoperable as designed, open, capable of only being closed with hand pump. No flag/classification society documentation could be provided allowing this type of operation. 74SOLAS(04) II-1/19.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 July 2024
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 27 July 2024 Resolved
In a ship in which oil fuel is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons onboard. PSCO Observed significant Fuel oil leaks on transfer pump following F/O bunkering, Non-approved oil catch pans in purifier space, and oil leaks with oil soaked lagging on A/E #3. 74SOLAS(97) II-2/15.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 July 2024
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 27 July 2024 Resolved
No person may cause a vessel to enter into or get underway on the navigable waters of the United States unless no more than 12 hours before entering or getting underway, the following equipment has been tested:Primary and secondary steering gear. The test procedure includes a visual inspection of the steering gear and its connecting linkage. PSCO observed significant hydraulic oil leaks on both steering gear systems as well as insignificant oil in reserve tank during inspection after vessel was moored. Condition was not identified on vessel checklist prior to port entry. 33 CFR 164.25 (a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 27 July 2024
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 4 March 2024 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Crew was unable to raise lifeboat on port side from embarkation back to cradle via hydraulic or manual means. 74SOLAS(97)III/19.2 60ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 March 2024
Resolution: Received class report attesting to repairs. Class report attached.
Engineering › Fuel Oil Service System › Piping
Issued 9 February 2012 Resolved
1420 The condition of the ship and its equipment shall be maintained to confrom with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Excessive fuel oil leaks were observed thrughout the engine room. The standing pools of oil caused by these leaks pose a potential fire hazard. (17A/C)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2012
Resolution: Received a class report attesting to the repair of the fuel oil leaks in the ships engine room
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 9 February 2012 Resolved
1420 In a ship in which oil is used, the arrangements for the storage, distribution, and utilization of the fuel oil shall be such as to ensure the safety of the ship and persons on board. The vessel's heavy fuel oil purifier system, heavy fuel oil pump, and shaft seal lubricating system were found to be leaking oil. (17 A/C) 74 SOLAS (97 CONS. ED.) II-2/15.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2012
Resolution: Received a class report attesting to the repair of the leaking fuel oil purifier system, heavy fuel oil pump and shaft seal lubricating system.
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 February 2012 Resolved
0950 All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. Multiple lighting appliances on the vessel were found with exposed wiring and missing covers. (17 A/C) 74 SOLAS (97 CONS. ED.) II-1/45.1.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2012
Resolution: Received a class report attesting to the repair and proper installation of missing lighting appliances removing all electrical hazards.
Fire Fighting › Fire Hoses › Condition
Issued 9 February 2012 Resolved
0730- Fire Fighting systems and appliances shall be kept in good working order and readily available for immediate use. Multiple hoses were found with several leaks. The vessels SMS plan mandates that all damaged and suspect hoses are to be immediately replaced. 17(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2012
Resolution: Received a class report attesting to the fact that all leaking hoses were renewed as necessary.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 9 February 2012 Resolved
0999- The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The shipboard incinerator failed to start during examination, even after several attempts. Vessel rectified deficiency on the spot. 10(c)
Due 9 February 2012
Resolved 9 February 2012
Resolution: Vessel rectified deficiency on the spot by fixing the incinerator starting device an it operating correctly.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Loading Arms
Issued 9 February 2012 Resolved
0999- The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The vessels port side bunker hose crane has a continuous hydraulic oil leak. 40(a)(c)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 February 2012
Resolution: Received a class report attesting that the oil level glass had been repaired and the pneumatic crane was tested and found to be operating satisfactory.
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 7 July 2008 Resolved
Steering Gear Hydraulic storage tank has cracks around the weld of the vent. SOLAS 74/78 as ammended CHAPT I-11. Prior to next US port after sailing foreign to the satisfaction of class/RO/RSO.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 August 2008
Resolution: RECEIVED CLASS REPORT FOR REPAIRS MADE TO STEERING GEAR HYDRAULIC TANK. CLASS ATTENDED VESSEL. DEFICIENCY RECTIFIED.
Engineering › Diesel Engine (propulsion-direct drive) › Distributor (air start)
Issued 10 May 2007 Resolved
It has been reported that the vessel has experienced a temporary loss of propulsion. Provide class report concerning repairs and attesting to satisfactory operation of propulsion prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 May 2007
Resolution: Received Class Report. All Sat.
Engineering › Diesel Engine (propulsion-direct drive) › Governor
Issued 3 August 2006 Resolved
Vessel lost control/propulsion of MDE. Provide class report to the attestation safe operation of the main diesel engine.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 6 August 2006
Lifesaving
Issued 16 February 2001 Resolved
PORT LIFEBOAT REMOTE LOWERING WIRE IS NOT RIGGED PROPERLY._x001C_ _x001C_ REPAIR (ADJUST) REMOTE BRAKE RELEASE CABLE TO PERMIT BOAT FULLY LOWRING TO_x001C_THE WATER TO THE SATISFACTION OF CLASS PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 26 March 2001
Resolved 26 March 2001

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.