EXPEDITION

EXPEDITION is a 1961 passenger vessel (inspected). The Coast Guard has recorded 26 inspections since 1981, most recently in April 2001, along with 50 deficiencies.

Records from 1981 to 2001. Most recent: inspection, 23 April 2001.

Built
1961
Last inspected
23 April 2001
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WTA6525
Flag
UNITED STATES
—
Maury page id
psix-44154

Inspections, by type

…with no type recorded8
Years with a record 16 calendar years (1981–2001)
The 26 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 25 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)50.8 ft × 13.0 ft × 6.1 ft
Registered tonnagegross 20 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY CRAFT · LOREAUVILLE, LA, UNITED STATES · built 1961
Hull materialAluminum
PropulsionNot recorded
Hull shapeSail (Distinct Keel)
Hull configurationMonohull
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20 - Simplified, Gross Ton
18 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 26

23 April 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1389377
14 September 2000 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1433730
16 May 1997 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1390530
3 June 1994 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1171842
10 May 1993 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1148118
5 November 1992 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1136207
20 May 1992 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 943863
5 September 1991 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1246084
19 June 1991 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1221152
9 May 1991 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1223617
26 September 1990 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 927029
15 June 1990 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1217430
30 May 1990 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1216813
15 June 1989 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1352611
16 May 1989 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 889907
5 May 1988 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1044131
7 January 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1008952
18 July 1987 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1336788
24 July 1986 COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1296953
13 February 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 992266
13 February 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 996399
20 August 1985 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1296911
14 August 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1283569
17 August 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966670
8 August 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272741
26 February 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275248

Deficiency record · 50

Construction/Loadline › Hull › Hull Plating
Issued 23 April 2001 Resolved
C/R stbd stern tube.
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Construction/Loadline › Hull › Hull Plating
Issued 23 April 2001 Resolved
Gauge bottom plating IWO keel & P/S chines.
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Construction/Loadline › Hull › Hull Plating
Issued 23 April 2001 Resolved
Clad weld Side shell fwd of MSD vent (stbd hull).
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Construction/Loadline › Hull › Side Shell
Issued 23 April 2001 Resolved
C/R SS below lower rub rail approximately 18' from bow (stbd hull).
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Construction/Loadline › Hull › Hull Plating
Issued 23 April 2001 Resolved
Clad weld SS approximately 10' aft of bow (port hull).
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Construction/Loadline › Hull › Hull Plating
Issued 23 April 2001 Resolved
C/R SS approximately 12' aft of bow (port hull).
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Construction/Loadline › Hull › Hull Plating
Issued 23 April 2001 Resolved
C/R SS approximately 15' aft of bow (port hull).
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Construction/Loadline › Hull › Hull Plating
Issued 23 April 2001 Resolved
C/R SS approximately 18' aft of bow (port hull).
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Construction/Loadline › Hull › Hull Plating
Issued 23 April 2001 Resolved
C/R SS IWO through hull fitting & lower rub rail (port hull).
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 23 April 2001 Resolved
Renew throughhull fitting for MSD vent (cabin).
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Construction/Loadline › Hull › Hull Plating
Issued 23 April 2001 Resolved
C/R aft bulkhead to good metal (min 6" above the main deck)(cabin).
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Construction/Loadline › Hull › Hull Plating
Issued 23 April 2001 Resolved
C/R stbd SS approximately 1 1/2 frames fwd of aft bulkhead (cabin).
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Construction/Loadline › Hull › Hull Plating
Issued 23 April 2001 Resolved
V/V #3 stanchion from fwd IWO TDWF (stbd)(cabin).
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 23 April 2001 Resolved
V/W flat stock transverse framing @ chine as marked (recommend trip brackets)(cabin).
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Construction/Loadline › Structures › Manhole
Issued 23 April 2001 Resolved
Make e/r hatches watertight (engine room).
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 23 April 2001 Resolved
Install lagging P/S exhaust manifold from source to point of water injection (engine room).
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 23 April 2001 Resolved
C/R all 3 longitudinal stiffeners P & S side, aft bay (engine room).
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Construction/Loadline › Structures › Superstructure
Issued 23 April 2001 Resolved
C/R deck beams outlining hatches as marked (engine room).
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 23 April 2001 Resolved
C/R aft bulkhead IWO stbd exhaust & IWO battery installations to good metal(engine room).
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Construction/Loadline › Structures › End Bulkhead
Issued 23 April 2001 Resolved
C/R vertical stiffener IWO copper hydraulic lines to good metal (lazarette).
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Engineering › Sea-water System (primary cooling) › Valve
Issued 23 April 2001 Resolved
Make all through hull valves & sea strainers open for inspection.
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Construction/Loadline › Hull › Hull Plating
Issued 23 April 2001 Resolved
Clad weld 2 locations of SS approximately 10' fwd of transom (stbd hull).
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Construction/Loadline › Hull › Hull Plating
Issued 23 April 2001 Resolved
C/R Side shell IWO through hull fitting & lower rub rail (stbd hull).
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Construction/Loadline › Penetrations › Valve Flange
Issued 23 April 2001 Resolved
Move 2 vents (1/2") approximately 6" above the waterline to deck area (stbdhull).
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Engineering
Issued 19 June 1991 Resolved
REMOVE COPPER RETURN LINES AND REPLACE IN CONTINUOUS LENGTH TO TANK._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 June 1991
Resolved 19 June 1991
Electrical
Issued 9 May 1991 Resolved
REMOUNT ELE. CONN. BOX FORWARD BULKHEAD IN ENGINE ROOM.
Condition: Unknown
Due 9 May 1991
Resolved 9 May 1991
Construction/Loadline
Issued 9 May 1991 Resolved
REMOVE HOSE PORT SIDE AFT OF ENGINE ROOM THROUGH HULL AND CAP
Condition: Unknown
Due 9 May 1991
Resolved 9 May 1991
Engineering
Issued 9 May 1991 Resolved
REMOVE COPPER RETURN LINES AND REPLACE IN CONTINOUS LENGTH TO TANK.
Condition: Unknown
Due 9 May 1991
Resolved 9 May 1991
Engineering
Issued 9 May 1991 Resolved
REMOVE NON-APPROVED FUEL HOSE ON MAIN FUEL LINE AT TANK AND INSTALL APPROVED FUEL HOSE
Condition: Unknown
Due 9 May 1991
Resolved 9 May 1991
Engineering
Issued 9 May 1991 Resolved
REMOVE PETCOCKS ON ALL FUEL STRAINERS
Condition: Unknown
Due 9 May 1991
Resolved 9 May 1991
Electrical
Issued 9 May 1991 Resolved
PROVE PROPER OPERATION OF A/C GENERATOR AND PROVIDE DATA ON GENERATOR OUT PUT
Condition: Unknown
Due 9 May 1991
Resolved 9 May 1991
Electrical
Issued 9 May 1991 Resolved
REMOVE WIRE NUTS ON MSD SYSTEM AND HARD WIRE
Condition: Unknown
Due 9 May 1991
Resolved 9 May 1991
Lifesaving
Issued 9 May 1991 Resolved
PROVIDE 10 ADULT AND 2 CHILDREN LIFE PRESERVERS UNTIL PROVIDED AND CLEARED TOTAL PERSON IS REDUCED TO 29 AND NO MORE THAN 2 CHILDREN MAY BE CARRIED.
Condition: Unknown
Due 9 May 1991
Resolved 9 May 1991
Navigation
Issued 9 May 1991 Resolved
PROVE PROPER OPERATION OF RUNNING LIGHTS AND REDO IN ACCORDANCE WITH 72 COLREGS (DAY TIME OPS ONLY)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 May 1991
Resolved 9 May 1991
Electrical
Issued 9 May 1991 Resolved
REMOVE WIRE NOT ON A/C GENERATOR AND HARD WIRE
Condition: Unknown
Due 9 May 1991
Resolved 9 May 1991
Engineering
Issued 9 May 1991 Resolved
REMOVE ALL NON-APPROVED FUEL HOSE ON PORT ENGINE FROM PRIMARY FUEL STRAINERTO ENGINE SUPPLY, RETURN AND INSTALL APPROVED FUEL HOSE.
Condition: Unknown
Due 9 May 1991
Resolved 9 May 1991
Documentation
Issued 30 May 1990 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 30 May 1990
Resolved 30 May 1990
Electrical
Issued 30 May 1990 Resolved
WHEN THE REBUILT GENERATOR IS INSTALLED, PROVE PROPER OPERATION OF SAME ANDALL 110V APPLIANCES, RADAR, ETC.
Condition: Unknown
Due 30 May 1990
Resolved 30 May 1990
Documentation
Issued 30 May 1990 Resolved
PROVIDE AND POST A VALID FCC SAFETY RADIOTELEPHONE CERTIFICATE.
Condition: Unknown
Due 30 May 1990
Resolved 30 May 1990
Lifesaving
Issued 16 May 1989 Resolved
REPAIR WATERLIGHT TO (10MAN) LIFEFLOAT.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Lifesaving
Issued 16 May 1989 Resolved
REPLACE PERSONNEL TIE OFFS TO (10MAN) LIFEFLOAT.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Lifesaving
Issued 16 May 1989 Resolved
REPAIR (SPLICE) LIFELINE TO (10MAN) LIFEFLOAT.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Lifesaving
Issued 16 May 1989 Resolved
REPLACE RING BOUY.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Construction/Loadline
Issued 16 May 1989 Resolved
REPLACE CRACKED WINDOW PORT SIDE FORWARD.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Engineering
Issued 16 May 1989 Resolved
CLEAN ENGINEROOM BILGES.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Engineering
Issued 16 May 1989 Resolved
DEMONSTRATE BILGE HIGH LEVEL ALARM.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Electrical
Issued 16 May 1989 Resolved
REMOVE EXTRANEOUS WIRING THROUGHOUT VESSEL.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Electrical
Issued 16 May 1989 Resolved
DEMONSTRATE OPERATION OF GENERATOR INCLUDING PROPER OVERCURRENT PROTECTION (FUSES ETC.)
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Accommodation/Occupational Safety
Issued 16 May 1989 Resolved
PROVIDE MSD HOLDING TANK AND SHOW PROPER OPERATION.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Electrical
Issued 16 May 1989 Resolved
PROVIDE NEW BATTERY TERMINALS WHERE NECESSARY.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.