Records from 1981 to 2001. Most recent: inspection, 23 April 2001.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 26
23 April 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1389377
14 September 2000
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1433730
16 May 1997
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1390530
3 June 1994
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1171842
10 May 1993
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1148118
5 November 1992
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1136207
20 May 1992
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 943863
5 September 1991
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1246084
19 June 1991
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1221152
9 May 1991
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1223617
26 September 1990
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 927029
15 June 1990
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1217430
30 May 1990
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1216813
15 June 1989
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1352611
16 May 1989
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 889907
5 May 1988
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1044131
7 January 1988
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1008952
18 July 1987
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1336788
24 July 1986
COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1296953
13 February 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 992266
13 February 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 996399
20 August 1985
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1296911
14 August 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1283569
17 August 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966670
8 August 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272741
26 February 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275248
Construction/Loadline › Hull › Hull Plating
Issued 23 April 2001
Resolved
C/R stbd stern tube.
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Construction/Loadline › Hull › Hull Plating
Issued 23 April 2001
Resolved
Gauge bottom plating IWO keel & P/S chines.
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Construction/Loadline › Hull › Hull Plating
Issued 23 April 2001
Resolved
Clad weld Side shell fwd of MSD vent (stbd hull).
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Construction/Loadline › Hull › Side Shell
Issued 23 April 2001
Resolved
C/R SS below lower rub rail approximately 18' from bow (stbd hull).
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Construction/Loadline › Hull › Hull Plating
Issued 23 April 2001
Resolved
Clad weld SS approximately 10' aft of bow (port hull).
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Construction/Loadline › Hull › Hull Plating
Issued 23 April 2001
Resolved
C/R SS approximately 12' aft of bow (port hull).
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Construction/Loadline › Hull › Hull Plating
Issued 23 April 2001
Resolved
C/R SS approximately 15' aft of bow (port hull).
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Construction/Loadline › Hull › Hull Plating
Issued 23 April 2001
Resolved
C/R SS approximately 18' aft of bow (port hull).
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Construction/Loadline › Hull › Hull Plating
Issued 23 April 2001
Resolved
C/R SS IWO through hull fitting & lower rub rail (port hull).
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 23 April 2001
Resolved
Renew throughhull fitting for MSD vent (cabin).
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Construction/Loadline › Hull › Hull Plating
Issued 23 April 2001
Resolved
C/R aft bulkhead to good metal (min 6" above the main deck)(cabin).
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Construction/Loadline › Hull › Hull Plating
Issued 23 April 2001
Resolved
C/R stbd SS approximately 1 1/2 frames fwd of aft bulkhead (cabin).
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Construction/Loadline › Hull › Hull Plating
Issued 23 April 2001
Resolved
V/V #3 stanchion from fwd IWO TDWF (stbd)(cabin).
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 23 April 2001
Resolved
V/W flat stock transverse framing @ chine as marked (recommend trip brackets)(cabin).
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Construction/Loadline › Structures › Manhole
Issued 23 April 2001
Resolved
Make e/r hatches watertight (engine room).
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 23 April 2001
Resolved
Install lagging P/S exhaust manifold from source to point of water injection (engine room).
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 23 April 2001
Resolved
C/R all 3 longitudinal stiffeners P & S side, aft bay (engine room).
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Construction/Loadline › Structures › Superstructure
Issued 23 April 2001
Resolved
C/R deck beams outlining hatches as marked (engine room).
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 23 April 2001
Resolved
C/R aft bulkhead IWO stbd exhaust & IWO battery installations to good metal(engine room).
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Construction/Loadline › Structures › End Bulkhead
Issued 23 April 2001
Resolved
C/R vertical stiffener IWO copper hydraulic lines to good metal (lazarette).
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Engineering › Sea-water System (primary cooling) › Valve
Issued 23 April 2001
Resolved
Make all through hull valves & sea strainers open for inspection.
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Construction/Loadline › Hull › Hull Plating
Issued 23 April 2001
Resolved
Clad weld 2 locations of SS approximately 10' fwd of transom (stbd hull).
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Construction/Loadline › Hull › Hull Plating
Issued 23 April 2001
Resolved
C/R Side shell IWO through hull fitting & lower rub rail (stbd hull).
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Construction/Loadline › Penetrations › Valve Flange
Issued 23 April 2001
Resolved
Move 2 vents (1/2") approximately 6" above the waterline to deck area (stbdhull).
Condition: Unknown
Due 23 April 2001
Resolved 26 October 2004
Resolution: CLEARED REQUIREMENT, OWNER DID NOT RECEIVE CREDIT FOR THIS INSPECTION.
Engineering
Issued 19 June 1991
Resolved
REMOVE COPPER RETURN LINES AND REPLACE IN CONTINUOUS LENGTH TO TANK._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 June 1991
Resolved 19 June 1991
Electrical
Issued 9 May 1991
Resolved
REMOUNT ELE. CONN. BOX FORWARD BULKHEAD IN ENGINE ROOM.
Condition: Unknown
Due 9 May 1991
Resolved 9 May 1991
Construction/Loadline
Issued 9 May 1991
Resolved
REMOVE HOSE PORT SIDE AFT OF ENGINE ROOM THROUGH HULL AND CAP
Condition: Unknown
Due 9 May 1991
Resolved 9 May 1991
Engineering
Issued 9 May 1991
Resolved
REMOVE COPPER RETURN LINES AND REPLACE IN CONTINOUS LENGTH TO TANK.
Condition: Unknown
Due 9 May 1991
Resolved 9 May 1991
Engineering
Issued 9 May 1991
Resolved
REMOVE NON-APPROVED FUEL HOSE ON MAIN FUEL LINE AT TANK AND INSTALL APPROVED FUEL HOSE
Condition: Unknown
Due 9 May 1991
Resolved 9 May 1991
Engineering
Issued 9 May 1991
Resolved
REMOVE PETCOCKS ON ALL FUEL STRAINERS
Condition: Unknown
Due 9 May 1991
Resolved 9 May 1991
Electrical
Issued 9 May 1991
Resolved
PROVE PROPER OPERATION OF A/C GENERATOR AND PROVIDE DATA ON GENERATOR OUT PUT
Condition: Unknown
Due 9 May 1991
Resolved 9 May 1991
Electrical
Issued 9 May 1991
Resolved
REMOVE WIRE NUTS ON MSD SYSTEM AND HARD WIRE
Condition: Unknown
Due 9 May 1991
Resolved 9 May 1991
Lifesaving
Issued 9 May 1991
Resolved
PROVIDE 10 ADULT AND 2 CHILDREN LIFE PRESERVERS UNTIL PROVIDED AND CLEARED TOTAL PERSON IS REDUCED TO 29 AND NO MORE THAN 2 CHILDREN MAY BE CARRIED.
Condition: Unknown
Due 9 May 1991
Resolved 9 May 1991
Navigation
Issued 9 May 1991
Resolved
PROVE PROPER OPERATION OF RUNNING LIGHTS AND REDO IN ACCORDANCE WITH 72 COLREGS (DAY TIME OPS ONLY)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 May 1991
Resolved 9 May 1991
Electrical
Issued 9 May 1991
Resolved
REMOVE WIRE NOT ON A/C GENERATOR AND HARD WIRE
Condition: Unknown
Due 9 May 1991
Resolved 9 May 1991
Engineering
Issued 9 May 1991
Resolved
REMOVE ALL NON-APPROVED FUEL HOSE ON PORT ENGINE FROM PRIMARY FUEL STRAINERTO ENGINE SUPPLY, RETURN AND INSTALL APPROVED FUEL HOSE.
Condition: Unknown
Due 9 May 1991
Resolved 9 May 1991
Documentation
Issued 30 May 1990
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 30 May 1990
Resolved 30 May 1990
Electrical
Issued 30 May 1990
Resolved
WHEN THE REBUILT GENERATOR IS INSTALLED, PROVE PROPER OPERATION OF SAME ANDALL 110V APPLIANCES, RADAR, ETC.
Condition: Unknown
Due 30 May 1990
Resolved 30 May 1990
Documentation
Issued 30 May 1990
Resolved
PROVIDE AND POST A VALID FCC SAFETY RADIOTELEPHONE CERTIFICATE.
Condition: Unknown
Due 30 May 1990
Resolved 30 May 1990
Lifesaving
Issued 16 May 1989
Resolved
REPAIR WATERLIGHT TO (10MAN) LIFEFLOAT.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Lifesaving
Issued 16 May 1989
Resolved
REPLACE PERSONNEL TIE OFFS TO (10MAN) LIFEFLOAT.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Lifesaving
Issued 16 May 1989
Resolved
REPAIR (SPLICE) LIFELINE TO (10MAN) LIFEFLOAT.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Lifesaving
Issued 16 May 1989
Resolved
REPLACE RING BOUY.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Construction/Loadline
Issued 16 May 1989
Resolved
REPLACE CRACKED WINDOW PORT SIDE FORWARD.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Engineering
Issued 16 May 1989
Resolved
CLEAN ENGINEROOM BILGES.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Engineering
Issued 16 May 1989
Resolved
DEMONSTRATE BILGE HIGH LEVEL ALARM.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Electrical
Issued 16 May 1989
Resolved
REMOVE EXTRANEOUS WIRING THROUGHOUT VESSEL.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Electrical
Issued 16 May 1989
Resolved
DEMONSTRATE OPERATION OF GENERATOR INCLUDING PROPER OVERCURRENT PROTECTION (FUSES ETC.)
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Accommodation/Occupational Safety
Issued 16 May 1989
Resolved
PROVIDE MSD HOLDING TANK AND SHOW PROPER OPERATION.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Electrical
Issued 16 May 1989
Resolved
PROVIDE NEW BATTERY TERMINALS WHERE NECESSARY.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989